908 resultados para Method of quantification


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper undertakes a content analysis of the discourse on the Open Method of Coordination on Health Care (OMC/HC) in order to show how equity and solidarity are increasingly linked to optimisation and, as such, how neoliberalism increasingly frames health care. Some of the side-effects of this reframing for politics are highlighted: legitimating and extending EU governance, reducing the space for oppositional formations and limited citizenship. The analysis begins by interrogating the broader context of the Lisbon Strategy II, after which the techniques of the OMC/HC and its substantive outputs are analysed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Index properties such as the liquid limit and plastic limit are widely used to evaluate certain geotechnical parameters of fine-grained soils. Measurement of the liquid limit is a mechanical process, and the possibility of errors occurring during measurement is not significant. However, this is not the case for plastic limit testing, despite the fact that the current method of measurement is embraced by many standards around the world. The method in question relies on a fairly crude procedure known widely as the ‘thread rolling' test, though it has been the subject of much criticism in recent years. It is essential that a new, more reliable method of measuring the plastic limit is developed using a mechanical process that is both consistent and easily reproducible. The work reported in this paper concerns the development of a new device to measure the plastic limit, based on the existing falling cone apparatus. The force required for the test is equivalent to the application of a 54 N fast-static load acting on the existing cone used in liquid limit measurements. The test is complete when the relevant water content of the soil specimen allows the cone to achieve a penetration of 20 mm. The new technique was used to measure the plastic limit of 16 different clays from around the world. The plastic limit measured using the new method identified reasonably well the water content at which the soil phase changes from the plastic to the semi-solid state. Further evaluation was undertaken by conducting plastic limit tests using the new method on selected samples and comparing the results with values reported by local site investigation laboratories. Again, reasonable agreement was found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Invention relates to a method of manufacture of a composite concrete article, and in particular to a method of manufacture of a concrete article having textile structures integrated into the surface of the concrete to provide a novel aesthetic and/or functional surface finish

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complexity of sustainable development means that it is often difficult to evaluate and communicate the concept effectively. One standard method to reduce complexity and improve Communication, while maintaining scientific objectivity, is to use selected indicators. The aim of this paper is to describe and evaluate a process Of public participation in the selection of sustainable development indicators that utilised the Q-method for discourse analysis. The Q-method was Utilised to combine public opinion with technical expertise to create a list of technically robust indicators that would be relevant to the public, The method comprises statement collection, statement analysis, Q-sorts and Q-sort analysis. The results of the Q-method generated a list of statements for which a preliminary list of indicators was then developed by a team of experts from the fields of environmental science, sustainable development and Psychology. Subsequently members of the public evaluated the preliminary list of indicators, to select a final list of indicators that were both technically sound and incorporated the views of the public. The Utilisation of the Q-method in this process was evaluated using previously published criteria. The application of the Q-method in this context needs to be considered not only by the quality of the indicators developed, but also from the perspective of the benefit of the process to the participants. it was concluded that the Q-method provided an effective framework for public participation in the selection of indicators as it allowed the public to discuss Sustainable development in familiar language and in the context of their daily lives. By combining this information with expert input, a list of technically robust indicators that resonate with the public was developed. The results demonstrated that many citizens are not aware Of Sustainable development, and if it is to be successfully communicated to them, then indicators and policy need to be couched in terms familiar and relevant to citizen and communities. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Orthogonal frequency division multiplexing (OFDM) requires an expensive linear amplifier at the transmitter due to its high peak-to-average power ratio (PAPR). Single carrier with cyclic prefix (SC-CP) is a closely related transmission scheme that possesses most of the benefits of OFDM but does not have the PAPR problem. Although in a multipath environment, SC-CP is very robust to frequency-selective fading, it is sensitive to the time-selective fading characteristics of the wireless channel that disturbs the orthogonality of the channel matrix (CM) and increases the computational complexity of the receiver. In this paper, we propose a time-domain low-complexity iterative algorithm to compensate for the effects of time selectivity of the channel that exploits the sparsity present in the channel convolution matrix. Simulation results show the superior performance of the proposed algorithm over the standard linear minimum mean-square error (L-MMSE) equalizer for SC-CP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of diffraction of an optical wave by a 2D periodic metal aperture array with square, circular, and ring apertures is solved with allowance for the finite permittivity of a metal in the optical band. The correctness of the obtained results is verified through comparison with experimental data. It is shown that the transmission coefficient can be substantially greater than the corresponding value reached in the case of diffraction by a grating in a perfectly conducting screen.