945 resultados para MRI-guided cryoablation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic value of specific MR features for detection of suspected placental invasion according to observers' experience.Methods and Materials: Our study population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI. In twelve out of them placental invasion was histopathologically proven, the 13 other women (52%) without placental invasion served as control group. Multiplanar T1- and T2-weighted sequences had been performed mostly without IV contrast injection (1.5 T). MR examinations of the two groups were rendered anonymous, mixed, then independently and retrospectively reviewed by two senior and two junior radiologists in view of 8 MR features indicating placentar invasion including the degree. Results were compared with surgical diagnosis (placenta normal/increta/accreta/percreta). Interobserver agrement between senior and junior readers were calculated. Stepwise logistic regression and receiver operating (ROC) curvers were performed.Results: Demographics between the two groups were not statistically different. Overall sensitivity and specificity for detecting placentar invasion was 90.9% and 75.0% for senior readers, and 81.8% and 61.8% for junior readers respectively. The most significant MR features indicating placentar invasion were T2 hypointense placental bands, followed by placenta praevia, focally interrupted myometrial border, posterior placental insertion, and heterogeneous placental signal. For each of the evaluated MR features the interobserver agreement kappa between the two senior readers was superior than that between the junior readers, ranging from bad (<0.4) to good (0.4-0.75).Conclusions: MRI can be a reliable and reproducible tool for detection of suspected placentar invasion, however very variable according to the observers' experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Normal ageing is associated with characteristic changes in brain microstructure. Although in vivo neuroimaging captures spatial and temporal patterns of age-related changes of anatomy at the macroscopic scale, our knowledge of the underlying (patho)physiological processes at cellular and molecular levels is still limited. The aim of this study is to explore brain tissue properties in normal ageing using quantitative magnetic resonance imaging (MRI) alongside conventional morphological assessment. Using a whole-brain approach in a cohort of 26 adults, aged 18-85years, we performed voxel-based morphometric (VBM) analysis and voxel-based quantification (VBQ) of diffusion tensor, magnetization transfer (MT), R1, and R2* relaxation parameters. We found age-related reductions in cortical and subcortical grey matter volume paralleled by changes in fractional anisotropy (FA), mean diffusivity (MD), MT and R2*. The latter were regionally specific depending on their differential sensitivity to microscopic tissue properties. VBQ of white matter revealed distinct anatomical patterns of age-related change in microstructure. Widespread and profound reduction in MT contrasted with local FA decreases paralleled by MD increases. R1 reductions and R2* increases were observed to a smaller extent in overlapping occipito-parietal white matter regions. We interpret our findings, based on current biophysical models, as a fingerprint of age-dependent brain atrophy and underlying microstructural changes in myelin, iron deposits and water. The VBQ approach we present allows for systematic unbiased exploration of the interaction between imaging parameters and extends current methods for detection of neurodegenerative processes in the brain. The demonstrated parameter-specific distribution patterns offer insights into age-related brain structure changes in vivo and provide essential baseline data for studying disease against a background of healthy ageing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: MRI and PET with 18F-fluoro-ethyl-tyrosine (FET) have been increasingly used to evaluate patients with gliomas. Our purpose was to assess the additive value of MR spectroscopy (MRS), diffusion imaging and dynamic FET-PET for glioma grading. PATIENTS, METHODS: 38 patients (42 ± 15 aged, F/M: 0.46) with untreated histologically proven brain gliomas were included. All underwent conventional MRI, MRS, diffusion sequences, and FET-PET within 3±4 weeks. Performances of tumour FET time-activity-curve, early-to-middle SUVmax ratio, choline / creatine ratio and ADC histogram distribution pattern for gliomas grading were assessed, as compared to histology. Combination of these parameters and respective odds were also evaluated. RESULTS: Tumour time-activity-curve reached the best accuracy (67%) when taken alone to distinguish between low and high-grade gliomas, followed by ADC histogram analysis (65%). Combination of time-activity-curve and ADC histogram analysis improved the sensitivity from 67% to 86% and the specificity from 63-67% to 100% (p < 0.008). On multivariate logistic regression analysis, negative slope of the tumour FET time-activity-curve however remains the best predictor of high-grade glioma (odds 7.6, SE 6.8, p = 0.022). CONCLUSION: Combination of dynamic FET-PET and diffusion MRI reached good performance for gliomas grading. The use of FET-PET/MR may be highly relevant in the initial assessment of primary brain tumours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To use diffusion-tensor (DT) magnetic resonance (MR) imaging in patients with essential tremor who were treated with transcranial MR imaging-guided focused ultrasound lesion inducement to identify the structural connectivity of the ventralis intermedius nucleus of the thalamus and determine how DT imaging changes correlated with tremor changes after lesion inducement. MATERIALS AND METHODS: With institutional review board approval, and with prospective informed consent, 15 patients with medication-refractory essential tremor were enrolled in a HIPAA-compliant pilot study and were treated with transcranial MR imaging-guided focused ultrasound surgery targeting the ventralis intermedius nucleus of the thalamus contralateral to their dominant hand. Fourteen patients were ultimately included. DT MR imaging studies at 3.0 T were performed preoperatively and 24 hours, 1 week, 1 month, and 3 months after the procedure. Fractional anisotropy (FA) maps were calculated from the DT imaging data sets for all time points in all patients. Voxels where FA consistently decreased over time were identified, and FA change in these voxels was correlated with clinical changes in tremor over the same period by using Pearson correlation. RESULTS: Ipsilateral brain structures that showed prespecified negative correlation values of FA over time of -0.5 or less included the pre- and postcentral subcortical white matter in the hand knob area; the region of the corticospinal tract in the centrum semiovale, in the posterior limb of the internal capsule, and in the cerebral peduncle; the thalamus; the region of the red nucleus; the location of the central tegmental tract; and the region of the inferior olive. The contralateral middle cerebellar peduncle and bilateral portions of the superior vermis also showed persistent decrease in FA over time. There was strong correlation between decrease in FA and clinical improvement in hand tremor 3 months after lesion inducement (P < .001). CONCLUSION: DT MR imaging after MR imaging-guided focused ultrasound thalamotomy depicts changes in specific brain structures. The magnitude of the DT imaging changes after thalamic lesion inducement correlates with the degree of clinical improvement in essential tremor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Fluoroscopy-guided sacroiliac joint (SIJ) injections are technically difficult to perform because of the complex anatomy with helicoidal conformation of the joint. Our study describes the procedure of CT-guided SIJ injection, its feasibility and its rate of success. Methods and materials: Retrospective study included 46 consecutive patients. The procedure was performed by 3 MSK radiologists and consisted in a puncture with a posterior approach in the inferior articular part of SIJ, then in an injection of iodinated contrast agent (1ml) with CT control of SIJ space opacification and finally in an injection of slowacting corticosteroid. The SIJ approach was noticed as correct if there was an inferior articular puncture and if the needle was in the articular space, and as impossible if there was ankylosis or osteophytosis. The study was divided in two successive periods: period 1 (4 first months) and period 2 (12 last months). Results: SIJ opacification was successful in 57% (26/46). We observed a learning curve: opacification was succeeded in 66% (23/35) and there was incorrect approach in 9% (3/35) during period 2 versus respectively 27% (3/11) and 45% (5/11) during period 1. Causes of failure were incorrect approach in 40% (6/20 too low, 2/20 too high), impossible approach in 30% (6/20) and unexplained in 30% (6/20). Mean duration of procedure was about 28 minutes. No complication occurred. Conclusion: CT guided SIJ injection is safe and successful in 66% after a training period. The success depends on SIJ correct approach and also on anatomical lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calibrated BOLD fMRI is a promising alternative to the classic BOLD contrast due to its reduced venous sensitivity and greater physiological specificity. The delayed adoption of this technique for cognitive studies may stem partly from a lack of information on the reproducibility of these measures in the context of cognitive tasks. In this study we have explored the applicability and reproducibility of a state-of-the-art calibrated BOLD technique using a complex functional task at 7 tesla. Reproducibility measures of BOLD, CBF, CMRO2 flow-metabolism coupling n and the calibration parameter M were compared and interpreted for three ROIs. We found an averaged intra-subject variation of CMRO2 of 8% across runs and 33% across days. BOLD (46% across runs, 36% across days), CBF (33% across runs, 46% across days) and M (41% across days) showed significantly higher intra-subject variability. Inter-subject variability was found to be high for all quantities, though CMRO2 was the most consistent across brain regions. The results of this study provide evidence that calibrated BOLD may be a viable alternative for longitudinal and cognitive MRI studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion MRI is a well established imaging modality providing a powerful way to non-invasively probe the structure of the white matter. Despite the potential of the technique, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a wide variety of methods have been proposed to shorten acquisition times. [...] We here review a recent work where we propose to further exploit the versatility of compressed sensing and convex optimization with the aim to characterize the fiber orientation distribution sparsity more optimally. We re-formulate the spherical deconvolution problem as a constrained l0 minimization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The number of fluoroscopy-guided procedures in cardiology is increasing over time and it is appropriate to wonder whether technological progress or change of techniques is influencing patient exposure. The aim of this study is to examine whether patient dose has been decreasing over the years. Patient dose data of more than 7700 procedures were collected from two cardiology centres. A steady increase in the patient dose over the years was observed in both the centres for the two cardiological procedures included in this study. Significant increase in dose was also observed after the installation of a flat-panel detector. The increasing use of radial access may lead to an increase in the patient exposure. The monitoring of dose data over time showed a considerable increase in the patient exposure over time. Actions have to be taken towards dose reduction in both the centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Etudier et décrire étape par étape les aspects techniques de la thérapie par cryoablation percutanée ciblée (CPC). Matériels et méthodes: CPC est réalisée par un : adiologue interventionnel sous guidage échographique et/ou tomodensitométrique. Résultats: CPC est un traitement peu invasif qui utilise un froid extrême pour geler et détruire des tumeurs localisées dans le foie, les reins, la prostate, les poumons, les os, les seins et la peau. L'imagerie est utilisée pour guider le placement d'un ou plusieurs applicateurs à travers la peau jusqu'au site cible et surveiller le processus de congélation. De l'azote liquide ou du gaz d'argon circule au sein d'une aiguille-applicateur (CryoPhobe) créant froid intense au contact de la cible. Une sonde indépendante surveille la température du tissu environnant. Le froid est maintenu pendant au moins 20 minutes suivi d'un dégel actif de la "boule de glace". La procédure est ensuite répétée pour maximiser la destruction tumorale. La procédure dure environ 1 heure et se fait de manière ambulatoire. Conclusion: CPC est un traitement alternatif efficace du cancer chez des patients sélectionnés. Les propriétés destructrices des tissus tumoraux sont bien établies pour le cancer du rein, cependant des investigations supplémentaires sont nécessaires pour déterminer l'efficacité de CPC à long terme dans d'autres indications.