984 resultados para Lung volume measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME : Valganciclovir (Valcyte®) is an orally administered ester prodrug of the standard anticytomegalovirus (CMV) drug ganciclovir. This drug enabled an important reduction of the burden of CMV morbidity and mortality in solid organ transplant recipients. Prevention of CMV infection and treatment of CMV disease requires drug administration during many weeks. Oral drug administration is therefore convenient. Valganciclovir has been developed to overcome the poor oral availability of ganciclovir, which limits its concentration exposure after oral administration and thus its efficacy. This prodrug crosses efficiently the intestinal barrier, is then hydrolyzed into ganciclovir, providing exposure similar to intravenous ganciclovir. Valganciclovir is now preferred for the prophylaxis and treatment of CMV infection in solid organ transplant recipients. Nevertheless, adequate dosage adjustment is necessary to optimize its use, avoiding either insufficient or exaggerate exposure related to differences in its pharmacokinetic profile between patients. The main goal of this thesis was to better describe the pharmacokinetic and pharmacodynamic profile of valganciclovir in solid organ transplant recipients, to assess their reproducibility and their predictability, and thus to evaluate the current recommendations for valganciclovir dosage adjustment and the potential contribution of routine therapeutic drug monitoring (TDM) to patients' management. A total of 437 ganciclovir plasma concentration data from 65 transplant patients (41 kidney, 12 lung, 10 heart and 2 liver recipients, 58 under oral valganciclovir prophylaxis, 8 under oral valganciclovir treatment and 2 under intravenous ganciclovir) were measured using a validated chromatographic method (HPLC) developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by GFR, with further differences between graft types and sex (CL/GFR = 1.7 in kidney, 0.9 in heart and 1.2 in lung and liver recipients) with interpatient variability (CV%) of 26% and interoccasion variability of 12%. Body weight and sex influenced central volume of distribution (V1 = 0.34 l/kg in males and 0.27 l/kg in females) with an interpatient variability of 20%. Residual intrapatient variability was 21 %. No significant drug interaction influenced GCV disposition. VGC prophylactic efficacy and tolerability were good, without detectable dependence on GCV profile. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of GCV profile after oral VGC in solid organ transplant recipients, routine TDM does not appear to be clinically indicated. However, GCV plasma measurement may still be helpful in specific clinical situations such as documentation of appropriate exposure in patients with potentially compromised absorption, or lack of response to CMV disease treatment, or under renal replacement therapy. RESUME : Le valganciclovir (Valcyte®) est un promédicament oral du ganciclovir qui est un anti-infectieux de référence contre les infections à cytomegalovirus (CMV). Cet antiviral a permis de réduire les effets délétères de cette infection jusqu'ici responsable d'une importante morbidité et mortalité chez les transplantés d'organe. La prévention et le traitement de l'infection à CMV sont donc nécessaires mais requièrent l'administration d'un agent antiviral sur une longue période. Un médicament administré par voie orale représente donc un avantage évident. Le valganciclovir a été développé dans le but d'améliorer la faible absorption orale du ganciclovir, et donc son efficacité. Cet ester valylique du ganciclovir traverse plus facilement la barrière gastro-intestinale, puis est hydrolysé en ganciclovir dans la circulation sanguine, produisant une exposition comparable à celle d'une perfusion intraveineuse de ganciclovir. De ce fait, le valganciclovir est devenu largement utilisé pour la prophylaxie mais aussi le traitement de l'infection à CMV. Néanmoins une utilisation optimale de ce nouveau médicament nécessite de bonnes connaissances sur son profil pharmacocinétique afin d'établir un schéma de dose adapté pour éviter tant une surexposition qu'une sous-exposition résultant des différences d'élimination entre les patients. Le but de cette thèse a été d'étudier le profil pharmacocinétique et pharmacodynamique du valganciclovir chez les transplantés d'organe ainsi que sa reproductibilité et sa prédictibilité. Il s'agissait d'apprécier de manière critique le schéma actuellement recommandé pour l'adaptation des doses de valganciclovir, mais aussi la contribution éventuelle d'un suivi des concentrations sanguines en routine. Un total de 437 taux sanguins de ganciclovir ont été mesurés, provenant de 65 patients transplantés d'organe (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques, 58 sous une prophylaxie orale de valganciclovir, 8 sous un traitement de valganciclovir et 2 sous un traitement intraveineux). Une méthode de chromatographie liquide à haute performance a été développée et validée pour cette étude. Les résultats ont été ensuite analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle à deux compartiments avec absorption de premier ordre a permis de décrire les données. La clairance systémique était principalement influencée par le débit de filtration glomérulaire (GFR), avec une différence entre les types de greffe et les sexes (CL/GFR = 1.7 chez les greffés rénaux, 0.9 pour les greffés cardiaques et 1.2 pour le groupe des greffés pulmonaires et hépatiques) avec un variabilité inter-individuelle de 26% (CV%) et une variabilité inter-occasion de 12%. Le poids corporel ainsi que le sexe avaient une influence sur le volume central de distribution (V1 = 0.34 l/kg chez les hommes et 0.27 l/kg chez les femmes) avec une variabilité inter-individuelle de 20%. La variabilité intra-individuelle résiduelle était de 21 %. Aucune interaction médicamenteuse n'a montré d'influence sur le profil du ganciclovir. La prophylaxie avec le valganciclovir s'est révélée efficace et bien tolérée. En conclusion, cette analyse souligne l'importance d'une adaptation de la dose du valganciclovir à la fonction rénale et au poids du patient. Au vu de la bonne reproductibilité et prédictibilité du profil pharmacocinétique du ganciclovir chez les patients transplantés recevant du valganciclovir, un suivi des concentrations sanguines en routine ne semble pas cliniquement indiqué. Néanmoins, la mesure des taux plasmatiques de ganciclovir peut être utile dans certaines situations particulières, comme la vérification d'une exposition appropriée chez des patients susceptibles d'absorption insuffisante, ou ne répondant pas au traitement d'une infection à CMV ou encore sous épuration extra-rénale. RESUME LARGE PUBLIC : Le valganciclovir est un précurseur capable de libérer du ganciclovir, récemment développé pour améliorer la faible absorption orale de ce dernier. Une fois le valganciclovir absorbé, le ganciclovir libéré dans la circulation sanguine devient efficace contre les infections à cytomégalovirus. Ce virus largement répandu est responsable de maladies insidieuses et parfois graves chez les personnes présentant une baisse des défenses immunitaires, comme les greffés d'organe recevant un traitement anti-rejet. Le ganciclovir est administré pendant plusieurs mois consécutifs soit pour prévenir une infection après la transplantation, soit pour traiter une infection déclarée. La facilité d'administration du valganciclovir par voie orale représente un avantage sur une administration du ganciclovir par perfusion, qui nécessite une hospitalisation. Toutefois, la voie orale peut être une source supplémentaire de variabilité chez les patients, avec un impact potentiel sur l'efficacité ou la toxicité du médicament. Le but de cette étude a été - de décrire le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline de la pharmacocinétique) - de définir les facteurs cliniques pouvant expliquer les différences de concentration sanguine observées entre les patients sous une posologie donnée - d'explorer les relations entre les concentrations du médicament dans le sang et son efficacité ou la survenue d'effets indésirables (dont l'étude relève de la discipline de la pharmacodynamie). Cette étude a nécessité le développement et la validation, d'une méthode d'analyse pour mesurer la concentration sanguine du ganciclovir, puis son application à 437 échantillons provenant de 65 patients transplantés d'organe solide (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques) recevant du valganciclovir. Les résultats des mesures effectuées ont été analysés à l'aide d'un outil mathématique afin d'élaborer un modèle du devenir du médicament dans le sang chez chaque patient et à chaque occasion. Cette étude a permis d'évaluer chez des patients recevant le valganciclovir, la vitesse à laquelle l'organisme absorbe, distribue, puis élimine le médicament. La vitesse d'élimination dépendait étroitement de la fonction rénale, du type de greffe et du sexe alors que la distribution dépendait du poids et du sexe du patient. La variabilité non expliquée par ces facteurs cliniques était modérée et vraisemblablement sans conséquence clinique évidente soit sur l'efficacité ou la tolérance, qui se révèlent très satisfaisantes chez les patients de l'étude. Les observations n'ont pas révélé de relation entre les concentrations de médicament et l'efficacité thérapeutique ou la survenue d'effets indésirables, confirmant que les doses relativement faibles utilisées dans notre collectif de patients suffisaient à produire une exposition reproductible à des concentrations adéquates. En conclusion, le profil (et par conséquent l'absorption) du valganciclovir chez les patients transplantés semble bien prédictible après une adaptation de la dose à la fonction rénale et au poids du patient. Un contrôle systématique des concentrations sanguines n'est probablement pas indiqué en routine, mais cette mesure peut présenter un intérêt dans certaines conditions particulières.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The impact of abnormal spirometric findings on risk for incident heart failure among older adults without clinically apparent lung disease is not well elucidated.METHODS: We evaluated the association of baseline lung function with incident heart failure, defined as first hospitalization for heart failure, in 2125 participants of the community-based Health, Aging, and Body Composition (Health ABC) Study (age, 73.6 +/- 2.9 years; 50.5% men; 62.3% white; 37.7% black) without prevalent lung disease or heart failure. Abnormal lung function was defined either as forced vital capacity (FVC) or forced expiratory volume in 1(st) second (FEV1) to FVC ratio below lower limit of normal. Percent predicted FVC and FEV1 also were assessed as continuous variables.RESULTS: During follow-up (median, 9.4 years), heart failure developed in 68 of 350 (19.4%) participants with abnormal baseline lung function, as compared with 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR] 2.31; 95% confidence interval [CI], 1.74-3.07; P <.001). This increased risk persisted after adjusting for previously identified heart failure risk factors in the Health ABC Study, body mass index, incident coronary heart disease, and inflammatory markers (HR 1.83; 95% CI, 1.33-2.50; P <.001). Percent predicted (%) FVC and FEV 1 had a linear association with heart failure risk (HR 1.21; 95% CI, 1.11-1.32 and 1.18; 95% CI, 1.10-1.26, per 10% lower % FVC and % FEV1, respectively; both P <.001 in fully adjusted models). Findings were consistent in sex and race subgroups and for heart failure with preserved or reduced ejection fraction.CONCLUSIONS: Abnormal spirometric findings in older adults without clinical lung disease are associated with increased heart failure risk. (C) 2011 Elsevier Inc. All rights reserved. The American Journal of Medicine (2011) 124, 334-341

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Liver remnant volumes after major hepatic resection and graft volumes for liver transplantation correlate with surgical outcome. The relative contributions of the hepatic segments to total liver volume (TLV) are not well established. METHODS: TLV and hepatic segment volumes were measured with computed tomography (CT) in 102 patients without liver disease who underwent CT for conditions unrelated to the liver or biliary tree. RESULTS: TLV ranged from 911 to 2729 cm(3). On average, the right liver (segments V, VI, VII, and VIII) contributed approximately two thirds of TLV (997+/-279 cm(3)), and the left liver (segments II, III and IV) contributed approximately one third of TLV (493+/-127 cm(3)). Bisegment II+III (left lateral section) contributed about half the volume of the left liver (242+/-79 cm(3)), or 16% of TLV. Liver volumes varied significantly between patients--the right liver varied from 49% to 82% of TLV, the left liver, 17% to 49% of TLV, and bisegment II+III (left lateral section) 5% to 27% of TLV. Bisegment II+III contributed less than 20% of TLV in more than 75% of patients and the left liver contributed 25% or less of TLV in more than 10% of patients. DISCUSSION: There is clinically significant interpatient variation in hepatic volumes. Therefore, in the absence of appreciable hypertrophy, we recommend routine measurement of the future liver remnant before extended right hepatectomy (right trisectionectomy) and in selected patients before right hepatectomy if a small left liver is anticipated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine whether valganciclovir 450 mg every 48 h for cytomegalovirus (CMV) prophylaxis provides appropriate ganciclovir exposure in solid organ transplant recipients during continuous renal replacement therapy (CRRT). PATIENTS AND METHODS: Ganciclovir pharmacokinetics was intensively studied in two lung transplant recipients under valganciclovir 450 mg every 48 h over one dosing interval. In vitro experiments using blank whole blood spiked with ganciclovir further investigated exchanges between plasma and erythrocytes. RESULTS: Ganciclovir disposition was characterized by apparent total body clearance of 3.3 and 5.8 L/h, terminal half-life of 16.9 and 14.1 h, and apparent volume of distribution of 60.3 and 104.9 L in Patients 1 and 2, respectively. The observed sieving coefficient was 1.05 and 0.96, and the haemofiltration clearance was 3.3 and 3.1 L/h. In vitro experiments confirmed rapid efflux of ganciclovir from red blood cells into plasma, increasing the apparent efficacy of haemofiltration. CONCLUSIONS: A valganciclovir dosage of 450 mg every 48 h appears adequate for patients under CRRT requiring prophylaxis for CMV infection, providing concentration levels in the range reported for 900 mg once daily dosing outside renal failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aims of the study were to use cone beam computed tomography (CBCT) images of nasopalatine duct cysts (NPDC) and to calculate the diameter, surface area, and 3D-volume using a custom-made software program. Furthermore, any associations of dimensions of NPDC with age, gender, presence/absence of maxillary incisors/canines (MI/MC), endodontic treatment of MI/MC, presenting symptoms, and postoperative complications were evaluated. MATERIAL AND METHODS: The study comprised 40 patients with a histopathologically confirmed NPDC. On preoperative CBCT scans, curves delineating the cystic borders were drawn in all planes and the widest diameter (in millimeter), surface area (in square millimeter), and volume (in cubic millimeter) were calculated. RESULTS: The overall mean cyst diameter was 15 mm (range 7-47 mm), the mean cyst surface area 566 mm(2) (84-4,516 mm(2)), and the mean cyst volume 1,735 mm(3) (65-25,350 mm(3)). For 22 randomly allocated cases, a second measurement resulted in a mean absolute aberration of ±4.2 % for the volume, ±2.8 % for the surface, and ±4.9 % for the diameter. A statistically significant association was found for the CBCT determined cyst measurements and the need for preoperative endodontic treatment to MI/MC and for postoperative complications. CONCLUSION: In the hands of a single experienced operator, the novel software exhibited high repeatability for measurements of cyst dimensions. Further studies are needed to assess the application of this tool for dimensional analysis of different jaw cysts and lesions including treatment planning. CLINICAL RELEVANCE: Accurate radiographic information of the bone volume lost (osteolysis) due to expansion of a cystic lesion in three dimensions could help in personalized treatment planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001). As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volume-controlled ventilator.METHODS: Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V). Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW), total lung weight (TLW), left lung weight (LLW), ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation.RESULTS: BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p <0.05) and CDH (p <0.05), but no differences were found between the subgroups V and N-V (p> 0.05). The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05). The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl.CONCLUSION: Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the most characteristic feature of paraquat poisoning is lung damage, a prospective controlled study was performed on excised rat lungs in order to estimate the intensity of lesion after different doses. Twenty-five male, 2-3-month-old non-SPF Wistar rats, divided into 5 groups, received paraquat dichloride in a single intraperitoneal injection (0, 1, 5, 25, or 50 mg/kg body weight) 24 h before the experiment. Static pressure-volume (PV) curves were performed in air- and saline-filled lungs; an estimator of surface tension and tissue works was computed by integrating the area of both curves and reported as work/ml of volume displacement. Paraquat induced a dose-dependent increase of inspiratory surface tension work that reached a significant two-fold order of magnitude for 25 and 50 mg/kg body weight (P<0.05, ANOVA), sparing lung tissue. This kind of lesion was probably due to functional abnormalities of the surfactant system, as was shown by the increase in the hysteresis of the paraquat groups at the highest doses. Hence, paraquat poisoning provides a suitable model of acute lung injury with alveolar instability that can be easily used in experimental protocols of mechanical ventilation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study evaluates the effect of blood volume expansion on the gastrointestinal transit of a charchoal meal (2.5 ml of an aqueous suspension consisting of 5% charcoal and 5% gum arabic) in awake male Wistar rats (200-270 g). On the day before the experiments, the rats were anesthetized with ether, submitted to left jugular vein cannulation and fasted with water ad libitum until 2 h before the gastrointestinal transit measurement. Blood volume expansion by iv infusion of 1 ml/min Ringer bicarbonate in volumes of 3, 4 or 5% body weight delayed gastrointestinal transit at 10 min after test meal administration by 21.3-26.7% (P<0.05), but no effect was observed after 1 or 2% body weight expansion. The effect of blood volume expansion (up to 5% body weight) on gastrointestinal transit lasted for at least 60 min (P<0.05). Mean arterial pressure increased transiently and central venous pressure increased and hematocrit decreased (P<0.05). Subdiaphragmatic vagotomy and yohimbine (3 mg/kg) prevented the delay caused by expansion on gastrointestinal transit, while atropine (0.5 mg/kg), L-NAME (2 mg/kg), hexamethonium (10 mg/kg), prazosin (1 mg/kg) or propranolol (2 mg/kg) were ineffective. These data show that blood volume expansion delays the gastrointestinal transit of a charcoal meal and that vagal and yohimbine-sensitive pathways appear to be involved in this phenomenon. The delay in gastrointestinal transit observed here, taken together with the modifications of gastrointestinal permeability to salt and water reported by others, may be part of the mechanisms involved in liquid excess management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carbon monoxide diffusing capacity (DLCO) or transfer factor (TLCO) is a particularly useful test of the appropriateness of gas exchange across the lung alveolocapillary membrane. With the purpose of establishing predictive equations for DLCO using a non-smoking sample of the adult Brazilian population, we prospectively evaluated 100 subjects (50 males and 50 females aged 20 to 80 years), randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with single breath (SB) absolute and volume-corrected (VA) DLCO values as dependent variables. In the prediction equations, age (years) and height (cm) had opposite effects on DLCOSB (ml min-1 mmHg-1), independent of gender (-0.13 (age) + 0.32 (height) - 13.07 in males and -0.075 (age) + 0.18 (height) + 0.20 in females). On the other hand, height had a positive effect on DLCOSB but a negative one on DLCOSB/VA (P<0.01). We found that the predictive values from the most cited studies using predominantly Caucasian samples were significantly different from the actually measured values (P<0.05). Furthermore, oxygen uptake at maximal exercise (VO2max) correlated highly to DLCOSB (R = 0.71, P<0.001); this variable, however, did not maintain an independent role to explain the VO2max variability in the multiple regression analysis (P>0.05). Our results therefore provide an original frame of reference for either DLCOSB or DLCOSB/VA in Brazilian males and females aged 20 to 80 years, obtained from the standardized single-breath technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tumor necrosis factor-alpha (TNF-alpha) is one of the most important proinflammatory cytokines which plays a central role in host defense and in the acute inflammatory response related to tissue injury. The major source of TNF-alpha are immune cells such as neutrophils and macrophages. We tested the hypothesis that pentoxifylline, a methylxanthine derivative, down-regulates proinflammatory cytokine expression during acute lung injury in rats. Male Wistar rats weighing 250 to 450 g were anesthetized ip with 50 mg/kg sodium thiopental and randomly divided into three groups: group 1 (N = 7): tidal volume (V T) = 7 ml/kg, respiratory rate (RR) = 50 breaths/min and normal saline infusion; group 2 (N = 7): V T = 42 ml/kg, RR = 9 breaths/min and normal saline infusion; group 3 (N = 7): V T = 42 ml/kg, RR = 9 breaths/min and pentoxifylline infusion. The animals were ventilated with an inspired oxygen fraction of 1.0, a positive end-expiratory pressure of 3 cmH2O, and normal saline or pentoxifylline injected into the left femoral vein. The mRNA of TNF-alpha rapidly increased in the lung tissue within 180 min of ventilation with a higher V T with normal saline infusion. The concentrations of inflammatory mediators were decreased in plasma and bronchoalveolar lavage (BAL) in the presence of higher V T with pentoxifylline infusion (TNF-alpha: plasma, 102.2 ± 90.9 and BAL, 118.2 ± 82.1; IL-1ß: plasma, 45.2 ± 42.7 and BAL, 50.2 ± 34.9, P < 0.05). We conclude that TNF-alpha produced by neutrophil influx may function as an alert signal in host defense to induce production of other inflammatory mediators.