973 resultados para Low level laser therapy
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Low-intensity laser has been used as a physical agent in various fields of medical sciences such as bone and tissue repair. Meanwhile little is known about its effects in adverse conditions such as abolition of load and osteopenic. With the assumption that the laser Ga-Al-As accelerates the process of bone consolidation, goal of this study was to evaluate bone mineral density (BMD) in incomplete transverse osteotomies of tibia in adult rats, treated with low power laser therapy in three different groups: G1 (n = 10), reference 15 days; G2 (n=10), suspended by the tail and, accordingly, treated with laser for 12 days; G3 (n = 10), suspended by the tail by 36 days and that after 21 days, there was laser treatment for 12 days. The right tibia treated with laser and left served as control. The laser was used to Ga-Al-As, DMC - Flash Lase® III, with wavelength 830nm, 100 mW, 4J, 140 J / cm ², 40s of application in 12 sessions. It was used densitometer-Lunar DPX®, with computer program for "small animals", and the analysis of BMD was made in the bone throughout the region and the osteotomy. The results showed no efficacy of laser therapy in the process of bone repair, both in animals of group 1, as in group 2 and 3. It follows that either the low-power laser was not an effective performance or the effects of laser therapy is not only manifested at the site of irradiation as well as the systemic level.
Resumo:
The aim of this study was to compare retrospectively the effect of three different treatments on the healing outcome of bisphosphonate-related osteonecrosis of the jaws (BRONJ) in cancer patients. Twenty-two cancer patients were treated for BRONJ with one of the following protocols: clinical (pharmacological therapy), surgical (pharmacological plus surgical therapy), or PRP plus LPT (pharmacological plus surgical plus platelet rich plasma (PRP) plus laser phototherapy (LPT). The laser treatment was applied with a continuous diode laser (InGaAlP, 660 nm) using punctual and contact mode, 40 mW, spot size 0.042 cm(2), 6 J/cm(2) (6 s) and total energy of 0.24 J per point. The irradiations were performed on the exposed bone and surrounding soft tissue. The analysis of demographic data and risk factors was performed by gathering the following information: age, gender, primary tumor, bisphosphonate (BP) used, duration of BP intake, history of chemotherapy, use of steroids, and medical history of diabetes. The association between the current state of BRONJ (with or without bone exposure) and other qualitative variables was determined using the chi-square or Fisher's exact test. In all tests, the significance level adopted was 5%. Most BRONJ lesions occurred in the mandible (77%) after tooth extraction (55%) and in women (72%). A significantly higher percentage of patients reached the current state of BRONJ without bone exposure (86%) in the PPR plus LPT group than in the pharmacological (0%) and surgical (40%) groups after 1-month follow-up assessment. These results suggest that the association of pharmacological therapy and surgical therapy with PRP plus LPT significantly improves BRONJ healing in oncologic patients. Although prospective studies with larger sample sizes are still needed, this preliminary study may be used to inform a better-designed future study. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVO: Avaliar a ação precoce do laser terapêutico e do ultrassom no processo de regeneração de uma lesão experimental em ratos. MÉTODO: Utilizou-se 24 ratos. Dezoito foram submetidos ao procedimento cirúrgico de lesão do nervo ciático por compressão, através de uma pinça hemostática acima da fossa poplítea. Os animais foram divididos em três grupos com seis animais em cada. Grupo controle normal. GI: controle lesado sem intervenção terapêutica. GII: intervenção terapêutica do laser ArGaAl. GIII: intervenção terapêutica do ultrassom Pulsado. Iniciamos as intervenções terapêuticas 24 horas após a lesão, com aplicações diárias, por um período de quatorze dias consecutivos. RESULTADOS: Ao avaliar a perimetria dos músculos da coxa direita obteve-se os seguintes valores médios de diminuição (mm), para cada grupo GI: 0,45; GII: 0,42; GIII: 0,40. Quanto ao tempo de deslocamento tanto o GII e GIII apresentaram diferença significativa, quando comparados ao GI. Na avaliação final do IFC o GII sobressaiu ao GIII. Quanto a cicatrização observou-se grande melhora no GII e GIII. CONCLUSÃO: Os resultados evidenciaram que a recuperação nervosa foi maior com a aplicação do laser. Nível de evidência II, Estudos terapêuticos - Investigação dos resultados do tratamento
Resumo:
The toxicity of long-term immunosuppressive therapy has become a major concern in long-term follow-up of heart transplant recipients. In this respect the quality of renal function is undoubtedly linked to cyclosporin A (CsA) drug levels. In cardiac transplantation, specific CsA trough levels have historically been maintained between 250 and 350 micrograms/L in many centers without direct evidence for the necessity of such high levels while using triple-drug immunosuppression. This retrospective analysis compares the incidence of acute and chronic graft rejection as well as overall mortality between groups of patients with high (250 to 350 micrograms/L) and low (150 to 250 micrograms/L) specific CsA trough levels. A total of 332 patients who underwent heart transplantation between October 1985 and October 1992 with a minimum follow-up of 30 days were included in this study (46 women and 276 men; aged, 44 +/- 12 years; mean follow-up, 1,122 +/- 777 days). Standard triple-drug immunosuppression included first-year specific CsA target trough levels of 250 to 300 micrograms/L. Patients were grouped according to their average creatinine level in the first postoperative year (group I, < 130 mumol/L, n = 234; group II, > or = 130 mumol/L, n = 98). The overall 5-year survival excluding the early 30-day mortality was 92% (group I, 216/232) and 91% (group II, 89/98) with 75% of the mortality due to chronic rejection. The rate of rejection for the entire follow-up period was similar in both groups (first year: group I, 3.2 +/- 2.6 rejection/patient/year; group II, 3.6 +/- 2.7 rejection/patient/year; p = not significant).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
BACKGROUND Management of persistent low-level viraemia (pLLV) in patients on combined antiretroviral therapy (cART) with previously undetectable HIV viral loads (VLs) is challenging. We examined virological outcome and management among patients enrolled in the Swiss HIV Cohort Study (SHCS). METHODS In this retrospective study (2000-2011), pLLV was defined as a VL of 21-400 copies/mL on ≥3 consecutive plasma samples with ≥8 weeks between first and last analyses, in patients undetectable for ≥24 weeks on cART. Control patients had ≥3 consecutive undetectable VLs over ≥32 weeks. Virological failure (VF), analysed in the pLLV patient group, was defined as a VL>400 copies/mL. RESULTS Among 9972 patients, 179 had pLLV and 5389 were controls. Compared to controls, pLLV patients were more often on unboosted PI-based (adjusted odds ratio, aOR, [95%CI] 3.2 [1.8-5.9]) and NRTI-only combinations (aOR 2.1 [1.1-4.2]) than on NNRTI and boosted PI-based regimens. At 48 weeks, 102/155 pLLV patients (66%) still had pLLV, 19/155 (12%) developed VF, and 34/155 (22%) had undetectable VLs. Predictors of VF were previous VF (aOR 35 [3.8-315]), unboosted PI-based (aOR 12.8 [1.7-96]) or NRTI-only combinations (aOR 115 [6.8-1952]), and VLs>200 during pLLV (aOR 3.7 [1.1-12]). No VF occurred in patients with persistent very LLV (pVLLV, 21-49 copies/mL; N=26). At 48 weeks, 29/39 patients (74%) who changed cART had undetectable VLs, compared to 19/74 (26%) without change (P<0.001). CONCLUSIONS Among patients with pLLV, VF was predicted by previous VF, cART regimen and VL ≥200. Most patients who changed cART had undetectable VLs 48 weeks later. These findings support cART modification for pLLV >200 copies/ml.
Resumo:
The majority of pemphigus vulgaris (PV) patients suffer from a live-threatening loss of intercellular adhesion between keratinocytes (acantholysis). The disease is caused by auto-antibodies that bind to desmosomal cadherins desmoglein (Dsg) 3 or Dsg3 and Dsg1 in mucous membranes and skin. A currently unresolved controversy in PV is whether apoptosis is involved in the pathogenic process. The objective of this study was to perform preclinical studies to investigate apoptotic pathway activation in PV pathogenesis with the goal to assess its potential for clinical therapy. For this purpose, we investigated mouse and human skin keratinocyte cultures treated with PV antibodies (the experimental Dsg3 monospecific antibody AK23 or PV patients IgG), PV mouse models (passive transfer of AK23 or PVIgG into adult and neonatal mice) as well as PV patients' biopsies (n=6). A combination of TUNEL assay, analyses of membrane integrity, early apoptotic markers such as cleaved poly-ADP-ribose polymerase (PARP) and the collapse of actin cytoskeleton failed to provide evidence for apoptosis in PV pathogenesis. However, the in vitro and in vivo PV models, allowing to monitor progression of lesion formation, revealed an early, transient and low-level caspase-3 activation. Pharmacological inhibition confirmed the functional implication of caspase-3 in major events in PV such as shedding of Dsg3, keratin retraction, proliferation including c-Myc induction, p38MAPK activation and acantholysis. Together, these data identify low-level caspase-3 activation downstream of disrupted Dsg3 trans- or cis-adhesion as a major event in PV pathogenesis that is non-synonymous with apoptosis and represents, unlike apoptotic components, a promising target for clinical therapy. At a broader level, these results posit that an impairment of adhesive functions in concert with low-level, non-lethal caspase-3 activation can evoke profound cellular changes which may be of relevance for other diseases including cancer.
Resumo:
Este estudo investigou os efeitos do laser de baixa intensidade na velocidade da movimentação ortodôntica de caninos submetidos à retração inicial. A amostra constou de 26 caninos superiores e inferiores, submetidos à retração inicial realizada com mola Niti, com força de 150g. Um dos caninos foi irradiado com laser de diodo, seguindo o protocolo de aplicação: 780nm/20mW/5Jcm2/0,2J por ponto/Et=2J, nos dias 0, 3 e 7 pós-ativação, sendo que o contralateral foi considerado placebo. A retração durou em média 4 meses, num total de 9 aplicações de laser. Os modelos de cada mês foram escaneados com scanner 3D (3Shape) e as imagens tridimensionais foram analisadas por meio do Software Geomagic Studio 5, para a mensuração da quantidade de movimentação dos caninos retraídos. Foi empregada a Análise de Variância a três critérios, seguida pelo teste de Tukey (p<0,05). Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos e dos molares, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cemento-esmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen, sendo este último avaliado somente nos caninos retraídos. Para isto, foi empregado o teste não paramétrico de Wilcoxon (p<0,05). Os resultados indicaram que houve um aumento estatisticamente significante na velocidade da movimentação dos caninos irradiados comparados ao seu contralateral, em todos os tempos avaliados, como também a preservação da integridade tecidual. Com isso, concluiu-se que o laser de diodo pode acelerar a movimentação ortodôntica, podendo contribuir para a diminuição do tempo de tratamento.(AU)
Resumo:
Este estudo investigou os efeitos do laser de baixa intensidade na velocidade da movimentação ortodôntica de caninos submetidos à retração inicial. A amostra constou de 26 caninos superiores e inferiores, submetidos à retração inicial realizada com mola Niti, com força de 150g. Um dos caninos foi irradiado com laser de diodo, seguindo o protocolo de aplicação: 780nm/20mW/5Jcm2/0,2J por ponto/Et=2J, nos dias 0, 3 e 7 pós-ativação, sendo que o contralateral foi considerado placebo. A retração durou em média 4 meses, num total de 9 aplicações de laser. Os modelos de cada mês foram escaneados com scanner 3D (3Shape) e as imagens tridimensionais foram analisadas por meio do Software Geomagic Studio 5, para a mensuração da quantidade de movimentação dos caninos retraídos. Foi empregada a Análise de Variância a três critérios, seguida pelo teste de Tukey (p<0,05). Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos e dos molares, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cemento-esmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen, sendo este último avaliado somente nos caninos retraídos. Para isto, foi empregado o teste não paramétrico de Wilcoxon (p<0,05). Os resultados indicaram que houve um aumento estatisticamente significante na velocidade da movimentação dos caninos irradiados comparados ao seu contralateral, em todos os tempos avaliados, como também a preservação da integridade tecidual. Com isso, concluiu-se que o laser de diodo pode acelerar a movimentação ortodôntica, podendo contribuir para a diminuição do tempo de tratamento.(AU)
Resumo:
Este estudo investigou os efeitos do laser de baixa intensidade na velocidade da movimentação ortodôntica de caninos submetidos à retração inicial. A amostra constou de 26 caninos superiores e inferiores, submetidos à retração inicial realizada com mola Niti, com força de 150g. Um dos caninos foi irradiado com laser de diodo, seguindo o protocolo de aplicação: 780nm/20mW/5Jcm2/0,2J por ponto/Et=2J, nos dias 0, 3 e 7 pós-ativação, sendo que o contralateral foi considerado placebo. A retração durou em média 4 meses, num total de 9 aplicações de laser. Os modelos de cada mês foram escaneados com scanner 3D (3Shape) e as imagens tridimensionais foram analisadas por meio do Software Geomagic Studio 5, para a mensuração da quantidade de movimentação dos caninos retraídos. Foi empregada a Análise de Variância a três critérios, seguida pelo teste de Tukey (p<0,05). Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos e dos molares, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cemento-esmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen, sendo este último avaliado somente nos caninos retraídos. Para isto, foi empregado o teste não paramétrico de Wilcoxon (p<0,05). Os resultados indicaram que houve um aumento estatisticamente significante na velocidade da movimentação dos caninos irradiados comparados ao seu contralateral, em todos os tempos avaliados, como também a preservação da integridade tecidual. Com isso, concluiu-se que o laser de diodo pode acelerar a movimentação ortodôntica, podendo contribuir para a diminuição do tempo de tratamento.(AU)
Resumo:
This is an Open Access article distributed under the terms of the Creative Commons Attribution 3.0 Unported (CC BY 3.0) License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Resumo:
This in vitro study aimed to analyze the effect of different parameters of phototherapy with low intensity laser on the viability of human dental pulp fibroblasts under the effect of substances released by bleaching gel. Cells were seeded into 96 wells plates (1 x 10³ cells/well) and placed in contact with culture medium conditioned by a 35 % hydrogen peroxide bleaching gel for 40 minutes, simulating the clinical condition of the in-office bleaching treatment. Cells cultured in ideal growth conditions served as positive control group (PC), and the cells grown in conditioned medium and non-irradiated served as negative control group (NC). Cells grown in conditioned medium were submitted to a single irradiation with a diode laser (40 mW, 0.04 cm²) emitting at visible red (660 nm; RL) or near infrared (780 nm; NIR) using punctual technique, in contact mode and energy densities of 4, 6 or 10 J/cm². The cell viability was analyzed through the MTT reduction assay immediately and 24 hours after the irradiation. The data was compared by ANOVA followed by the Tukey's test (p < 0.05). The cell viability increased significantly in 24 hours within each group. The PC presented cell viability significantly higher than NC in both experimental times. Only the NIR/10 J/cm² group presented cell viability similar to that of PC in 24 hours. The phototherapy with low intensity laser in defined parameters is able to compensate the cytotoxic effects of substances released by 35 % hydrogen peroxide bleaching gel.
Resumo:
Lead-induced neurotoxicity acquired by low-level long-term exposure has special relevance for children. A plethora of recent reports has demonstrated a direct link between low-level lead exposure and deficits in the neurobehavioral-cognitive performance manifested from childhood through adolescence. In many studies, aggressiveness and delinquency have also been suggested as symptoms of lead poisoning. Several environmental, occupational and domestic sources of contaminant lead and consequent health risks are largely identified and understood, but the occurrences of lead poisoning remain numerous. There is an urgent need for public health policies to prevent lead poisoning so as to reduce individual and societal damages and losses. In this paper we describe unsuspected sources of contaminant lead, discuss the economic losses and urban violence possibly associated with lead contamination and review the molecular basis of lead-induced neurotoxicity, emphasizing its effects on the social behavior, delinquency and IQ of children and adolescents