375 resultados para Locomotive boilers
Resumo:
The PM-brännaren (pellets burner) have on commission by the company been measured and evaluated in the combustion laboratory of SERC. The objective was to measure the perform-ance and the emissions of CO and NO for three different combustion powers and for start and stop conditions. The burner have been mounted in the Bionett-boiler from Ariterm and been adjusted by the company. The boiler has been connected to a buffer store that admits firing during long period with constant inlet temperature to the boiler. The measurements have been performed by operating the boiler on constant power until stationary conditions are reached. Thereafter the following two hours of operation have been evaluated. The results show that the burner fulfils the limit values for Blauer Engel labelling and the proposed limit values for Nordic Eco labelling. The measured concentration of NO is far below all organisations limit values for NOx. Concerning the start and stop emissions there are no demands from organisa-tions to compare with, but comparing with other boilers measured at SERC, the CO emissions from PM-brännaren is in the same order of magnitude.
Resumo:
Chunkwood is a wood fuel with a fuel particle length between 50 and 150 mm, i.e. with a sizebetween wood chips and conventional firewood. Chunkwood can be produced and handled asrational as wood chips and can dry during storage like conventional firewood. This is known sincelong. In project Smallwood for small scale heating we have investigated if chunkwood can be usedin a small scale as a fuel for heating detached houses in conventional firewood boilers as well asautomatically fed to a boiler in a similar way as wood chips. We have also compared completesystems for small scale production, distribution and heating with chunkwood, wood chips andconventional firewood.Storage of chunkwood produced for testing small scale boilers confirmed that chunkwood can dryduring storage at least as good as conventional firewood. Tests in different boilers for detachedhomes showed that chunkwood can be used in conventional firewood boilers as well as in automaticallyfed wood chips boilers. Chunkwood can be delivered to the customer to the same or lowercost as wood chips and firewood, but need much less handling by the customer than conventionalfirewood. However, if chunkwood is used in a conventional firewood boiler, it needs some handlingby shovel and wheelbarrow. Technical development of handling from the storage to the boiler isneeded. In a somewhat larger scale, e.g. a boiler for apartment blocks or a small district heatingsystem, chunkwood should be very interesting as a replacement of fuel pellets or fuel briquettes. Itwould be interesting with some projects, which in this scale demonstrates the whole system fromthe forest to heat.
Resumo:
Test method for integrated solar- biomass systems - Long term prediction trough short term measurementsSP Technical Research Institute of Sweden and SERC, Dalarna University have in cooperation developed a test method for integrated solar and biomass systems. The test method is performed under six days including two summer days, two winter days and two spring/autumn days true to real weather conditions and loads for a single family house. The aim of the test method is to get information about a Combisystem’s annual performance and operation throughout a short term test. Seven different solar Combisystems have been tested within the project together with a pellet boiler without solar collectors. In addition to that a comparative testing has been performed at the two laboratories at SP and at SERC on the same Combisystem. The test method developed within the project has been proved to withstand the aim of the project, which is to be able to compare the performance between the systems. The test method is also suitable for identification of possible operation problems so they can be taken care of and consequently improves the system.The project and the system testing reveal that it is in general favorable to combine biomass pellets with solar heating. Pellet boilers has normally a low performance during the summer period but combined with a solar collector the boiler can be switch off during this period. There are however big differences in performance between the tested. The efficiency of the pellet boiler is highly dependent of the operating conditions and elements like heat losses from the system, system configuration and control strategy have great influence of the performance of the system and the emissions. On the other hand, the performance and the size of the solar collectors have a minor effect on the overall system performance. There is obviously a big potential for improvement of the system´s performance and the developed test method is an essential way to implement this perfection.
Resumo:
In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.
Resumo:
Objective: For the evaluation of the energetic performance of combined renewable heating systems that supply space heat and domestic hot water for single family houses, dynamic behaviour, component interactions, and control of the system play a crucial role and should be included in test methods. Methods: New dynamic whole system test methods were developed based on “hardware in the loop” concepts. Three similar approaches are described and their differences are discussed. The methods were applied for testing solar thermal systems in combination with fossil fuel boilers (heating oil and natural gas), biomass boilers, and/or heat pumps. Results: All three methods were able to show the performance of combined heating systems under transient operating conditions. The methods often detected unexpected behaviour of the tested system that cannot be detected based on steady state performance tests that are usually applied to single components. Conclusion: Further work will be needed to harmonize the different test methods in order to reach comparable results between the different laboratories. Practice implications: A harmonized approach for whole system tests may lead to new test standards and improve the accuracy of performance prediction as well as reduce the need for field tests.
Resumo:
Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load. The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS. Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions. The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.
Resumo:
PEREIRA, J. P. ; CASTRO, B. P. S. ; VALENTIM, R. A. M. . Kit Educacional para Controle e Supervisão Aplicado a Nível. Holos, Natal, v. 2, p. 68-72, 2009
Resumo:
In this present work, the conditions of displacements and the behaviors of the users are evaluated, face to the physical adequacies in accessibility in the inserted area in the central quadrilateral of the Quarter of Cidade Alta, in the City of Natal/RN, space clipping established by its great meaning historical and cultural. For this reason such area was a target of an integrated actions plan during the years of 1993 and 1998, with the implantation of part of the Project CIDADE SEM BARREIRAS (City without Barriers) and, later, the implementation of the Project CIDADE PARA TODOS's proposals (City for All), having as supports the constant Brazilian norms inserted into the NB9050/1994 and in the Municipal law number 4.090/92, effective ones in the period of the interventions. Considering that the carried through actions at the time were directed to the elimination of the architectural barriers to guarantee the right to go and to come, the research received a human universe formed by all the people in situation of displacement in the central area of the interventions in the quarter of the Cidade Alta, independently of their locomotive or sensorial conditions, emphasizing the aspects most excellent how much to the accessibility of the sidewalk, as promotional of mobility, integration and urban organization, as well as of the public squares of that one quadrilateral, conceived, originally, as spaces of aggregation and social inclusion. The work appealed to the direct comment and the gotten results had been collated with the ex port facto law and technique norms, of the year of 2004, and with the legal devices contained in the Federal Decree number 5.296/2004, as way to certify the levels of efficiency of these adaptations in that it says respect to the current conditions of demanded accessibility and urban mobility
Resumo:
O ferrageamento corretivo é um método comumente ma Dvideow. O nível de significância adotado foi de 5%. No utilizado para alterar o padrão do andamento dos animais, presente estudo, não houve diferença significativa entre os assim como na terapêutica de diversas afecções do siste-dias avaliados, a elevação em seis graus da pinça ou talões ma locomotor dos equinos. No entanto, não existem, até não gerou desconforto durante a passada, portanto, os ani o momento, estudos científicos que revelem o período de mais podem retornar às atividades regulares de exercício e adaptação do andamento dos animais a este tipo de in-treinamento imediatamente após o ferrageamento. tervenção.O objetivo deste estudo foi avaliar o período de adaptação à ferraduras com elevação em seis graus da pinça ou talões em equinos caminhando em esteira rolante. O período de adaptação à ferradura foi avaliado nos tempos 0, 48 e 96 horas após cada tipo de ferrageamento proposto. Os animais foram gravados caminhando em esteira rolante. O comprimento da passada e a análise qualitativa do andamento foram realizados com o auxílio do programa Dvideow. O nível de significância adotado foi de 5%. No presente estudo, não houve diferença significativa entre os dias avaliados, a elevação em seis graus da pinça ou talões não gerou desconforto durante a passada, portanto, os animais podem retornar às atividades regulares de exercício e treinamento imediatamente após o ferrageamento.
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
Sugarcane bagasse ash (SCBA) is a residue resulting from the burning of bagasse in boilers in the sugarcane/alcohol industry. SCBA has a very high silica concentration and contains aluminum, iron, alkalis and alkaline earth oxides in smaller amounts. In this work, the properties of sintered ceramic bodies were evaluated based on the concentration of SCBA, which replaced non-plastic material. The ash was mixed (up to 60 wt%) with a clayed raw material that is used to produce roof tiles. Prismatic probes were pressed and sintered at different temperatures (up to 1200 degrees C). Technological tests of ceramic probes showed that the addition of ash has little influence on the ceramic properties up to 1000 C. X-ray diffraction and thermal analysis data showed that, above this temperature the ash participates in the sintering process and in the formation of new important phases. The results reported show that the reuse of SCBA in the ceramic industry is feasible. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Uma técnica para restituir a anatomia acetabular com aprofundamento da cavidade acetabular e reconstrução do ligamento da cabeça do fêmur e da cápsula articular, foi testada em nove cães, de raças de grande porte, portadores de displasia coxofemoral grave com subluxação acentuada ou luxação. O procedimento cirúrgico foi constituído de duas fases. Inicialmente, foi realizada a pectineotomia bilateral em todos os cães. A segunda intervenção nos mesmos cães incluiu abordagem e aprofundamento do acetábulo, reconstrução do ligamento da cabeça do fêmur e da cápsula. em geral, 30 dias após a cirurgia, os cães apoiavam o membro operado para se locomover. Com exceção de dois cães, todos os outros recuperaram a função locomotora do membro pélvico dentro de 60-90 dias. É concluído que a técnica de acetabuloplastia é uma boa alternativa para o tratamento da displasia coxofemoral grave.
Resumo:
In this work, thermodynamic and economic analyses are applied to a Brazilian thermal power plant operating with natural gas. The analyses are performed in two cases: the current configuration and the future configuration. The current configuration is constituted by four gas turbines which operate in open cycle. The future configuration is obtained by a plant repowering by addition of four recovery boilers, two steam turbines and others equipment and accessories necessary to operate in combined cycle. In order to obtain the performance parameters, energetic and exergetic analyses for each case considered are carried out. on the other hand, thermoeconomic analysis provides means to evaluate the influences of the capital and fuel costs in the composition of the electricity costs. Techniques of investment analysis are also applied to the new configuration and from the results obtained it is possible to verify the advantages of the modifications.
Resumo:
In industrial processes using aqueous solutions, corrosion of metal surfaces may occur at various locations. Much of the damage to steam generators and boilers is caused by corrosion. Dissolved oxygen in water is one of the most potent corrosion-causing factors, and therefore oxygen should be eliminated from steam-generating systems' feedwater. Chemical reduction, by reagents such as hydrazine or organic compounds, generally is used for the deoxygenation of water. This article reviews the major oxygen scavengers currently available.
Resumo:
In this paper, a thermoeconomic analysis method based on the First and the Second Law of Thermodynamics and applied to analyse the replacement of an equipment of a cogeneration system is presented. The cogeneration system consists of a gas turbine linked to a waste boiler. The electrical demand of the campus is approximately 9 MW but the cogen system generates approximately one third of the university requirement as well as 1.764 kg/s of saturated steam (at 0.861 MPa), approximately, from a single fuel source. The energy-economic study showed that the best system, based on pay-back period and based on the maximum savings (in 10 years), was the system that used the gas turbine M1T-06 of Kawasaki Heavy Industries and the system that used the gas turbine CCS7 of Hitachi Zosen, respectively. The exergy-economic study showed that the best system, which has the lowest EMC, was the system that used the gas turbine ASE50 of Allied Signal. © 2002 Elsevier Science Ltd. All rights reserved.