927 resultados para Liquid nitrogen temperature


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Clinical evidence of hematopoietic restoration with placental/umbilical cord blood (PCB) grafts indicates that PCB can be a useful source of hematopoietic stem cells for routine bone marrow reconstitution. In the unrelated setting, human leukocyte antigen (HLA)-matched donors must be obtained for candidate patients and, hence, large panels of frozen HLA-typed PCB units must be established. The large volume of unprocessed units, consisting mostly of red blood cells, plasma, and cryopreservation medium, poses a serious difficulty in this effort because storage space in liquid nitrogen is limited and costly. We report here that almost all the hematopoietic colony-forming cells present in PCB units can be recovered in a uniform volume of 20 ml by using rouleaux formation induced by hydroxyethyl starch and centrifugation to reduce the bulk of erythrocytes and plasma and, thus, concentrate leukocytes. This method multiples the number of units that can be stored in the same freezer space as much as 10-fold depending on the format of the storage system. We have also investigated the proportion of functional stem/progenitor cells initially present that are actually available to the recipient when thawed cryopreserved PCB units are infused. Progenitor cell viability is measurably decreased when thawed cells, still suspended in hypertonic cryopreservative solutions, are rapidly mixed with large volumes of isotonic solutions or plasma. The osmotic damage inflicted by the severe solute concentration gradient, however, can be averted by a simple 2-fold dilution after thawing, providing almost total recovery of viable hematopoietic progenitor cells.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The sediments of Hydrate Ridge/Cascadia margin contain extensive amounts of gas hydrate. A total of 57 sediment samples including gas hydrate were preserved in liquid nitrogen and have been imaged using computerized tomography to visualize hydrate distribution and shape. The analysis gives evidence that gas hydrate in vein and veinlet structures is the predominant shape in the deeper gas hydrate stability zone with dipping angles from 30° to 90°(vertical).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effectiveness of rapid and controlled heating of intact tissue to inactivate native enzymatic activity and prevent proteome degradation has been evaluated. Mouse brains were bisected immediately following excision, with one hemisphere being heat treated followed by snap freezing in liquid nitrogen while the other hemisphere was snap frozen immediately. Sections were cut by cryostatic microtome and analyzed by MALDI-MS imaging and minimal label 2-D DIGE, to monitor time-dependent relative changes in intensities of protein and peptide signals. Analysis by MALDI-MS imaging demonstrated that the relative intensities of markers varied across a time course (0-5 min) when the tissues were not stabilized by heat treatment. However, the same markers were seen to be stabilized when the tissues were heat treated before snap freezing. Intensity profiles for proteins indicative of both degradation and stabilization were generated when samples of treated and nontreated tissues were analyzed by 2-D DIGE, with protein extracted before and after a 10-min warming of samples. Thus, heat treatment of tissues at the time of excision is shown to prevent subsequent uncontrolled degradation of tissues at the proteomic level before any quantitative analysis, and to be compatible with downstream proteomic analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the most important components in electrochemical storage devices (batteries and supercapacitors) is undoubtedly the electrolyte. The basic function of any electrolyte in these systems is the transport of ions between the positive and negative electrodes. In addition, electrochemical reactions occurring at each electrode/electrolyte interface are the origin of the current generated by storage devices. In other words, performances (capacity, power, efficiency and energy) of electrochemical storage devices are strongly related to the electrolyte properties, as well as, to the affinity for the electrolyte to selected electrode materials. Indeed, the formulation of electrolyte presenting good properties, such as high ionic conductivity and low viscosity, is then required to enhance the charge transfer reaction at electrode/electrolyte interface (e.g. charge accumulation in the case of Electrochemical Double Layer Capacitor, EDLC). For practical and safety considerations, the formulation of novel electrolytes presenting a low vapor pressure, a large liquid range temperature, a good thermal and chemical stabilities is also required.

This lecture will be focused on the effect of the electrolyte formulation on the performances of electrochemical storage devices (Li-ion batteries and supercapacitors). During which, a summary of the physical, thermal and electrochemical data obtained by our group, recently, on the formulation of novel electrolyte-based on the mixture of an ionic liquid (such as EmimNTf2 and Pyr14NTf2) and carbonate or dinitrile solvents will be presented and commented. The impact of the electrolyte formulation on the storage performances of EDLC and Li-ion batteries will be also discussed to further understand the relationship between electrolyte formulation and electrochemical performances. This talk will also be an opportunity to further discuss around the effects of additives (SEI builder: fluoroethylene carbonate and vinylene carbonate), ionic liquids, structure and nature of lithium salt (LiTFSI vs LiPF6) on the cyclability of negative electrode to then enhance the electrolyte formulation. For that, our recent results on TiSnSb and graphite negative electrodes will be presented and discussed, for example 1,2.

1-C. Marino, A. Darwiche1, N. Dupré, H.A. Wilhelm, B. Lestriez, H. Martinez, R. Dedryvère, W. Zhang, F. Ghamouss, D. Lemordant, L. Monconduit “ Study of the Electrode/Electrolyte Interface on Cycling of a Conversion Type Electrode Material in Li Batteries” J. Phys.chem. C, 2013, 117, 19302-19313

2- Mouad Dahbi, Fouad Ghamouss, Mérièm Anouti, Daniel Lemordant, François Tran-Van “Electrochemical lithiation and compatibility of graphite anode using glutaronitrile/dimethyl carbonate mixtures containing LiTFSI as electrolyte” 2013, 43, 4, 375-385.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During this work, a novel series of hydrophobic room temperature ionic liquids (ILs) based on five ether functionalized sulfonium cations bearing the bis(trifluoromethyl)sulfonylimide, [NTf2]- anion were synthesized and characterized. Their physicochemical properties, such as density, viscosity and ionic conductivity, electrochemical window along with thermal properties including phase transition behavior and decomposition temperature, have been measured. All of these ILs showed large liquid range temperature, low viscosity and good conductivity. Additionally, by combining DFT calculations along with electrochemical characterization it appears that these novel ILs show good electrochemical stability windows, suitable for the potential application as electrolyte materials in electrochemical energy storage devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The off-cycle refrigerant mass migration has a direct influence on the on-cycle performance since compressor energy is necessary to redistribute the refrigerant mass. No studies, as of today, are available in the open literature which experimentally measured the lubricant migration within a refrigeration system during cycling or stop/start transients. Therefore, experimental procedures measuring the refrigerant and lubricant migration through the major components of a refrigeration system during stop/start transients were developed and implemented. Results identifying the underlying physics are presented. The refrigerant and lubricant migration of an R134a automotive A/C system-utilizing a fixed orifice tube, minichannel condenser, plate and fin evaporator, U-tube type accumulator and fixed displacement compressor-was measured across five sections divided by ball valves. Using the Quick-Closing Valve Technique (QCVT) combined with the Remove and Weigh Technique (RWT) using liquid nitrogen as the condensing agent resulted in a measurement uncertainty of 0.4 percent regarding the total refrigerant mass in the system. The determination of the lubricant mass distribution was achieved by employing three different techniques-Remove and Weigh, Mix and Sample, and Flushing. To employ the Mix and Sample Technique a device-called the Mix and Sample Device-was built. A method to separate the refrigerant and lubricant was developed with an accuracy-after separation-of 0.04 grams of refrigerant left in the lubricant. When applying the three techniques, the total amount of lubricant mass in the system was determined to within two percent. The combination of measurement results-infrared photography and high speed and real time videography-provide unprecedented insight into the mechanisms of refrigerant and lubricant migration during stop-start operation. During the compressor stop period, the primary refrigerant mass migration is caused by, and follows, the diminishing pressure difference across the expansion device. The secondary refrigerant migration is caused by a pressure gradient as a result of thermal nonequilibrium within the system and causes only vapor phase refrigerant migration. Lubricant migration is proportional to the refrigerant mass during the primary refrigerant mass migration. During the secondary refrigerant mass migration lubricant is not migrating. The start-up refrigerant mass migration is caused by an imbalance of the refrigerant mass flow rates across the compressor and expansion device. The higher compressor refrigerant mass flow rate was a result of the entrainment of foam into the U-tube of the accumulator. The lubricant mass migration during the start-up was not proportional to the refrigerant mass migration. The presence of water condensate on the evaporator affected the refrigerant mass migration during the compressor stop period. Caused by an evaporative cooling effect the evaporator held 56 percent of the total refrigerant mass in the system after three minutes of compressor stop time-compared to 25 percent when no water condensate was present on the evaporator coil. Foam entrainment led to a faster lubricant and refrigerant mass migration out of the accumulator than liquid entrainment through the hole at the bottom of the U-tube. The latter was observed for when water condensate was present on the evaporator coil because-as a result of the higher amount of refrigerant mass in the evaporator before start-up-the entrainment of foam into the U-tube of the accumulator ceased before the steady state refrigerant mass distribution was reached.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Presently avocado germplasm is conserved ex situ in the form of field repositories across the globe including Australia. The maintenance of germplasm in the field is costly, labour and land intensive, exposed to natural disasters and always at the risk of abiotic and biotic stresses. The aim of this study was to overcome these problems using cryopreservation to store avocado (Persea americana Mill.) somatic embryos (SE). Two vitrification-based methods of cryopreservation were optimised (cryovial and droplet-vitrification) using four avocado cultivars (‘A10′, ‘Reed’, ‘Velvick’ and ‘Duke-7′). SE of the four cultivars were stored for short-term (one hour) in liquid nitrogen using the cryovial-vitrification method and showed a viability of 91%, 73%, 86% and 80% respectively. While when using the droplet vitrification method viabilities of 100%, 85% and 93% were recorded for ‘A10′, ‘Reed’ and ‘Velvick’. For long-term storage, SE of cultivars ‘A10′, ‘Reed’ and ‘Velvick’ were successfully recovered with viability of 65–100% after 3 months of LN storage. For cultivar ‘Reed’ and ‘Velvick’ SE were recovered after 12 months of LN storage with viability of 67% and 59%, respectively. The outcome of this work contributes towards the establishment of a cryopreservation protocol that is applicable across multiple avocado cultivars.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo de esta investigación fue evaluar las características cuali-cuantitativas de espermatozoides de cuyes extraídos de la cola del epidídimo según su fenotipo y edad reproductiva. Se realizó en la granja Irquis de la U. de Cuenca en 20 reproductores identificados por sus características fenotípicas y dispuestos en cuatro grupos: 5 criollos jóvenes (CJ), 5 criollos adultos (CA), 5 mejorados jóvenes (MJ), y 5 mejorados adultos (MA). Los cuyes fueron hemicastrados y de los epidídimos fueron disectados la cola sobre una caja petri. Se recuperó los espermatozoides por Swim up, diluidos en 1ml de medio (18% rafinosa y 3% leche descremada), procesados con Triladyl®, refrigerados a 5oC/1 hora, y equilibrados por 0, 2, 24, 48, 96, 192, y 360 horass para su análisis de viabilidad espermática. Se congelaron únicamente los espermatozoides de 2 hs de equilibrio en vapores de nitrógeno. Se usó un DCA de 2x2: fenotipo y edad, y se usó un ANOVA para comprobar significancia. Se obtuvo interacción (P<0,05) entre factores con eficiencia atribuida a MJ a las 0 hs: en Concentración (C) y Anormalidades de cola (AC), a las 24 hs: en motilidad individual (MIP) y 48 hs: en Vitalidad (VE). En MIP no se encontró diferencias (P>0,05) en ningún tiempo de medición. En VE sólo encontró diferencias (P<0,05) a las 96 hs (CJ:18,0;MJ:10,2;MA:8,6;CA:6,0%). En anormalidades totales (AT) sólo se encontró diferencias (P<0,05) a las 0 hs (MJ:26,3;CJ:32,6;MA:36,2;CA:38,5%); y en AC se encontró diferencias (P<0,05) a las 0 hs (MJ:4,6; CJ:9,5; CA:11,5; MA:16,4%), y a las 48 hs (CA:5,7;CJ:7,3;MJ:16,0;MA:18,1%). En Integridad de la membrana (HOS-Test) se obtuvo (P<0,05) diferencias a las 2 hs (MJ:20,0; MA:13,1;CA:10,7;CJ:9,0%) y a las 96 hs (CA:25,4;CJ:15,3;MJ:9,7; MA:8,8%). A la congelabilidad no se obtuvo sobrevivencia de espermatozoides en ninguno de los tratamientos. En conclusión, la cantidad y calidad de espermatozoides epididimarios de cuyes identificados fenotípicamente varía según su edad; sin embargo, no se pudo comprobar su variación en la congelabilidad mostrándose absolutamente inviables a la crío conservación

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the quality of frozen-thawed semen of Garut rams that cryopreserved with Tris extender containing the various β-carotene concentrations. Semen was collected from four mature Garut rams using artificial vagina once a week. Immediately after initial evaluation, semen was divided into four parts and diluted with Tris extender containing 5% glycerol + 0% (control), 0.001% (Kt0.001), 0.002% (Kt0.002), and 0.003% (Kt0.003) β-carotene, respectively. Semen was loaded in 0.25 ml mini straw with the concentration of 200 million motile sperm. Semen was equilibrated at 5ºC for three hours, then frozen and stored in liquid nitrogen container for 7 days. Quality of processed-semen including motility, live sperm, intact acrosomal cap (IAC), and intact plasma membrane (IPM) were evaluated after diluted, equilibrated, and thawed, respectively. Concentration of malondialdehide (MDA) semen after thawing were evaluated. Data were analyzed as completely randomized design with four treatments and nine replicates. Means values were compared by least significant difference test at 0.05 significant level. Results indicated that mean value of post thawing motility and live sperm for Kt0.002 (50.55% and 56.78%) were significantly higher (P<0.05) than Kt0.001 (46.11% and 52.89%), Kt0.003 (46.67% and 53.33%) and control (46.67% and 52.33%). Mean value of post thawing IAC and IPM for Kt0.002 (51.00% and 53.78%) were significantly higher (P<0.05) than control ( 47.11% and 48.44%), but not significantly different with Kt0.001 (49.00% and 50.00%), and Kt0.003 (48.89% and 49.67%). MDA concentration of frozen-thawed semen for Kt0.001 (3.37 mg/kg), Kt0.002 (3.80 mg/kg), and Kt0.003 (4.61 mg/kg) were significantly lower (P<0.05) than control (5.24 mg/kg). in conclusion, concentration of 0.002% β-carotene in Tris extender is the optimal dose in improving frozen semen quality of garut rams. (Animal Production 7(1): 6-13 (2005) Key Words : β-carotene, frozen-thawed semen, intact plasma membrane, MDA, Garut Rams

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The electrochemical oxidation of potassium nitrite has been studied in the room temperature ionic liquid (RTIL) [C(2)mim][NTf2] by cyclic voltammetry at platinum electrodes. A chemically irreversible oxidation peak was observed, and a solubility of 7.5(+/- 0.5) mM and diffusion coefficient of 2.0(+/- 0.2) x 10(-11) m(2) s(-1) were calculated from potential step chronoamperometry on the microdisk electrode. A second, and sometimes third, oxidation peak was also observed when the anodic limit was extended, and these were provisionally assigned to the oxidation of nitrogen dioxide (NO2) and nitrate (NO3-), respectively. The electrochemical oxidation of nitrogen dioxide gas (NO2) was also studied by cyclic voltammetry in [C(2)mim][NTf2] on Pt electrodes of various size, giving a solubility of ca. 51(+/- 0.2) mM and diffusion coefficient of 1.6(+/- 0.05) x 10(-10) m(2) s(-1) (at 25 degrees C). It is likely that NO2 exists predominantly as its dimer, N2O4, at room temperature. The oxidation mechanism follows a CE process, which involves the initial dissociation of the dimer to the monomer, followed by a one-electron oxidation. A second, larger oxidation peak was observed at more positive potentials and is thought to be the direct oxidation of N2O4. In addition to understanding the mechanisms of NO2- and NO2 oxidations, this work has implications in the electrochemical detection of nitrite ions and of NO2 gas in RTIL media, the latter which may be of particular use in gas sensing.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This work explores the effects of argon and nitrogen, two electrochemically and chemically inert gases frequently used in sample preparation of room temperature ionic liquid (RTIL) solutions, on the eelectrochemical characterization of ferrocene (Fc) dissolved in the RTIL 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C(2)mim][NTf2]). Remarkably, chronoamperometrically determined diffusion coefficients of Fc in [C(2)mim][NTf2] are found to increase from 4.8 (+/- 0.2) x 10(-11) m(2) s(-1) under vacuum conditions to 6.6 (+/- 0.5) x 10(-11) m(2) s(-1) in an atmosphere of 1 atm Ar. In contrast, exposing a vacuum-purified sample to an atmosphere of 1 atm N-2 resulted in no significant change in the measured diffusion coefficient of Fc. The effect of dissolved argon on diffusion transport is unexpected and has implications in electrochemistry and elsewhere. Fc was found to volatilize under vacuum conditions. We propose, however, that evacuation of the cell by vacuum prior to electrochemical measurements being carried out is the only way to ensure that no contamination of the sample occurs, and use of an in situ method of determining the diffusion coefficient and concentration of Fc dispells,any ambiguity associated with Fc depletion by vacuum.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The conversion of biomass waste in the form of date seed into pyrolysis oil by fixed bed pyrolysis reactor has been taken into consideration in this study. A fixed bed pyrolysis has been designed and fabricated for obtaining liquid fuel from these date seeds. The major component of the system are fixed bed pyrolysis reactor, liquid condenser and liquid collector. The date seed in particle form is pyrolysed in an externally heated 7.6 cm diameter and 46 cm high fixed bed reactor with nitrogen as the carrier gas. The reactor is heated by means of a biomass source cylindrical heater from 4000C to 6000C. The products are oil, char and gas. The reactor bed temperature, running time and feed particle size are considered as process parameters. The parameters are found to influence the product yield significantly. A maximum liquid yield of 50 wt.% is obtained at a reactor bed temperature of 5000 C for a feed size volume of 0.11- 0.20 cm3 with a running time of 120 minutes. The pyrolysis oil obtained at this optimum process conditions are analyzed for some fuel properties and compared with some other biomass derived pyrolysis oils and also with conventional fuels. The oil is found to possess favorable flash point and reasonable density and viscosity. The higher calorific value is found to be 28.636 MJ/kg which is significantly higher than other biomass derived pyrolysis oils.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Among various thermo-chemical conversion processes, pyrolysis is considered as an emerging technology for liquid oil production. The conversion of biomass waste in the form of plum seed into pyrolysis oil by fixed bed pyrolysis reactor has been taken into consideration in this study. A fixed bed pyrolysis has been designed and fabricated for obtaining liquid fuel from this plum seeds. The major component of the system are fixed bed pyrolysis reactor, liquid condenser and liquid collectors. The plum seed in particle form is pyrolysed in an externally heated 7.6 cm diameter and 46 cm high fixed bed reactor with nitrogen as the carrier gas. The reactor is heated by means of a biomass source cylindrical heater from 4000C to 6000C. The products are oil, char and gas. The reactor bed temperature, running time and feed particle size are considered as process parameters. The parameters are found to influence the product yield significantly. A maximum liquid yield of 39 wt% of biomass feed is obtained with particle size of 2.36-4.75 mm at a reactor bed temperature of 520oC with a running time of 120 minutes. The pyrolysis oil obtained at this optimum process conditions are analyzed for some fuel properties and compared with some other biomass derived pyrolysis oils and conventional fuels. The oil is found to possess favorable flash point and reasonable density and viscosity. The higher calorific value is found to be 22.39 MJ/kg which is higher than other biomass derived pyrolysis oils.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The renovation of biomass waste in the form of Mahogany seed waste into bio-fuel as well as activated carbon by fixed bed pyrolysis reactor has been taken into consideration in this study. The mahogany seed in particle form is pyrolyzed in an enormously heated fixed bed reactor with nitrogen as the carrier gas. The reactor is heated from 4000C to 6000C using a external heater in which rice husk and charcoal are used as the heater biomass fuel. Reactor bed temperature, running time and feed particle size have been varied to get the optimum operating conditions of the system. The parameters are found to influence the product yields to a large extent. A maximum liquid and char yield are 49 wt. % and 35 wt. % respectively obtained at a reactor bed temperature 5000C when the running time is 90 minutes. Acquired pyrolyzed oil at these optimal process conditions were analyzed for some of their properties as an alternative fuel. The oil possesses comparable flame temperature, favorable flash point and reasonable viscosity along with somewhat higher density. The kinematic viscosity of the derived fuel is 3.8 cSt and density is 1525 kg/m3. The higher calorific value is found 32.4 MJ/kg which is significantly higher than other biomass derived fuel. Moderate adsorption capacity of the prepared activated carbon in case of methyl blue & tea water was also revealed.