942 resultados para LOW ASPECT RATIO


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The majority of the basalts drilled on Leg 65 in the Gulf of California are aphyric to sparsely phyric massive flows ranging in average thickness between 5 meters in the upper part of the sections in Holes 483 and 483B, where they are interlayered with sediment, and 14 meters in Hole 485A, where interlayered sediments constitute more than half of the section. Massive flows interlayered with pillows are generally less than 4 meters thick. The pillow lavas recovered are more phyric (up to 15 modal%) and contain two to three generations of plagioclase and olivine ± clinopyroxene. Plagioclase generally exceeds 60% of any given phenocryst assemblage. Resorbed olivine, clinopyroxene, and plagioclase megacrysts may reflect a high-pressure stage, the phenocrysts crystallizing in the main magma chamber and the skeletal microphenocrysts in dikes. Precise measurements of length/width ratios of different phenocryst types and compositions show low aspect ratios and large crystal volumes for early crystals and high ratios and low volumes for late crystals grown under strong undercooling conditions. The minerals examined show wide ranges in composition: in particular, plagioclase ranges from An92 to An36; clinopyroxene ranges from Ca41Mg51Fe8 in the cores of phenocrysts to Ca40**36 Mg45**49Fe15**20 in the groundmass; and olivine ranges from Fo86 to Fo81. The wide range in mineral compositions, together with evidence of disequilibrium based on textures and comparisons of glass and mineral compositions, indicate complex crystallization histories involving both polybaric crystal fractionation and magma mixing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Here we report 420 kyr long records of sediment geochemical and color variations from the southwestern Iberian Margin. We synchronized the Iberian Margin sediment record to Antarctic ice cores and speleothem records on millennial time scales and investigated the phase responses relative to orbital forcing of multiple proxy records available from these cores. Iberian Margin sediments contain strong precession power. Sediment "redness" (a* and 570-560 nm) and the ratio of long-chain alcohols to n-alkanes (C26OH/(C26OH + C29)) are highly coherent and in-phase with precession. Redder layers and more oxidizing conditions (low alcohol ratio) occur near precession minima (summer insolation maxima). We suggest these proxies respond rapidly to low-latitude insolation forcing by wind-driven processes (e.g., dust transport, upwelling, precipitation). Most Iberian Margin sediment parameters lag obliquity maxima by 7-8 ka, indicating a consistent linear response to insolation forcing at obliquity frequencies driven mainly by high-latitude processes. Although the lengths of the time series are short (420 ka) for detecting 100 kyr eccentricity cycles, the phase relationships support those obtained by Shackleton []. Antarctic temperature and the Iberian Margin alcohol ratios (C26OH/(C26OH + C29)) lead eccentricity maxima by 6 kyr, with lower ratios (increased oxygenation) occurring at eccentricity maxima. CO2, CH4, and Iberian SST are nearly in phase with eccentricity, and minimum ice volume (as inferred from Pacific d18Oseawater) lags eccentricity maxima by 10 kyr. The phase relationships derived in this study continue to support a potential role of the Earth's carbon cycle in contributing to the 100 kyr cycle.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Flow transverse bedforms (ripples and dunes) are ubiquitous in rivers and coastal seas. Local hydrodynamics and transport conditions depend on the size and geometry of these bedforms, as they constitute roughness elements at the bed. Bedform influence on flow energy must be considered for the understanding of flow dynamics, and in the development and application of numerical models. Common estimations or predictors of form roughness (friction factors) are based mostly on data of steep bedforms (with angle-of-repose lee slopes), and described by highly simplified bedform dimensions (heights and lengths). However, natural bedforms often are not steep, and differ in form and hydraulic effect relative to idealised bedforms. Based on systematic numerical model experiments, this study shows how the hydraulic effect of bedforms depends on the flow structure behind bedforms, which is determined by the bedform lee side angle, aspect ratio and relative height. Simulations reveal that flow separation behind bedform crests and, thus, a hydraulic effect is induced at lee side angles steeper than 11 to 18° depending on relative height, and that a fully developed flow separation zone exists only over bedforms with a lee side angle steeper than 24°. Furthermore, the hydraulic effect of bedforms with varying lee side angle is evaluated and a reduction function to common friction factors is proposed. A function is also developed for the Nikuradse roughness (k s), and a new equation is proposed which directly relates k s to bedform relative height, aspect ratio and lee side angle.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Large asymmetric bed forms commonly develop in rivers. The turbulence associated with flow separation that develops over their steep lee side is responsible for the form shear stress which can represent a substantial part of total shear stress in rivers. This paper uses the Delft3D modeling system to investigate the effects of bed form geometry and forcing conditions on flow separation length and associated turbulence, and bed form shear stress over angle-of-repose (30 lee side angle) bed forms. The model was validated with lab measurements that showed sufficient agreement to be used for a systematic analysis. The influence of flow velocity, bed roughness, relative height (bed form height/water depth), and aspect ratio (bed form height/length) on the variations of the normalized length of the flow separation zone, the extent of the wake region (where the turbulent kinetic energy (TKE) was more than 70% of the maximum TKE), the average TKE within the wake region and the form shear stress were investigated. Form shear stress was found not to scale with the size of the flow separation zone but to be related to the product of the normalized extent of the wake region (extent of the wake region/extent of water body above the bed form) and the average TKE within the wake region. The results add to understanding of the hydrodynamics of bed forms and may be used for the development of better parameterizations of smallscale processes for application in large-scale studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El apartado <4.2 Altavoz> de la Norma Internacional UNE-EN ISO 140-5 [1] especifica que la directividad del altavoz usado en el ensayo debe asegurar en todas las bandas de frecuencias de interés, unas diferencias de nivel locales inferiores a 5dB (o a 10 dB para fachadas de dimensiones mayores a 5m), medidas en campo libre, sobre una superficie del mismo tamaño y orientación que la pared o elemento a ensayar. Este requisito debe verificarse en unas bandas de frecuencia de interés que sean como mínimo los tercios de octava desde 100Hz hasta 3150Hz, y preferiblemente desde 50Hz hasta 5kHz. Desde hace unos años, en el Laboratorio de sonido de la EUIT de Telecomunicación de la Universidad Politécnica de Madrid, los autores han implementado un método en el que, a partir de las medidas de directividad en cámara anecoica de la fuente sonora a ensayar, se calcula el campo sonoro directo sobre una superficie ficticia que representa un elemento de fachada en la misma disposición que se indica en la norma ICO 140-5 y con unas dimensiones según se requieran en el procedimiento. También se estima la dimensión horizontal máxima ΔXmax de una fachada rectangular en relación de aspecto fija que permite verificar la norma con los criterios de 5dB y 10dB de diferencias máximas de niveles directos en dicha fachada. En esta ponencia se detalla el procedimiento anterior. ABSTRACT. The Section "4.2 loudspeaker" of the UNE-EN ISO 140-5 International Standard: "Field measurements of airborne sound insulation of façade elements and façades", specifies that the directivity of the loudspeaker used in the test must ensure in all frequency bands of interest, local level differences less than 5dB (or 10dB for façade dimensions greater than 5m), measured in free field over an area of the same size and orientation as the wall or element to be tested. This requirement must be verified in the frequency bands of interest which are, at least, the third octave bands from 100Hz to 3150Hz, preferably from 50Hz to 5kHz. In recent years, in the Laboratory of Sound of the EUIT Telecomunicación (Universidad Politécnica de Madrid), the authors have implemented a method that, from directivity measurements of loudspeakers performed in the anechoic room, the direct sound field on a surface in the same layout as indicated in the ISO standard is calculated. It is also estimated the maximum horizontal dimension Δxmax of a rectangular façade for each aspect ratio which verify the standard criteria of either 5dB or 10dB for the maximum differences of direct levels in the façade. This paper details the procedure above introduced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present direct-drive target design studies for the laser mégajoule using two distinct initial aspect ratios (A = 34 and A = 5). Laser pulse shapes are optimized by a random walk method and drive power variations are used to cover a wide variety of implosion velocities between 260 km/s and 365 km/s. For selected implosion velocities and for each initial aspect ratio, scaled-target families are built in order to find self-ignition threshold. High-gain shock ignition is also investigated in the context of Laser MégaJoule for marginally igniting targets below their own self-ignition threshold.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A theoretical study of linear global instability of incompressible flow over a rectangular spanwise-periodic open cavity in an unconfined domain is presented. Comparisons with the limited number of results available in the literature are shown. Subsequently, the parameter space is scanned in a systematic manner, varying Reynolds number, incoming boundary-layer thickness and length-to-depth aspect ratio. This permits documenting the neutral curves and leading eigenmode characteristics of this flow. Correlations constructed using the results obtained collapse all available theoretical data on the three-dimensional instabilities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El problema del flujo sobre una cavidad abierta ha sido estudiado en profundidad en la literatura, tanto por el interés académico del problema como por sus aplicaciones prácticas en gran variedad de problemas ingenieriles, como puede ser el alojamiento del tren de aterrizaje de aeronaves, o el depósito de agua de aviones contraincendios. Desde hace muchos a˜nos se estudian los distintos tipos de inestabilidades asociadas a este problema: los modos bidimensionales en la capa de cortadura, y los modos tridimensionales en el torbellino de recirculación principal dentro de la cavidad. En esta tesis se presenta un estudio paramétrico completo del límite incompresible del problema, empleando la herramienta de estabilidad lineal conocida como BiGlobal. Esta aproximación permite contemplar la estabilidad global del flujo, y obtener tanto la forma como las características de los modos propios del problema físico, sean estables o inestables. El estudio realizado permite caracterizar con gran detalle todos los modos relevantes, así como la envolvente de estabilidad en el espacio paramétrico del problema incompresible (Mach nulo, variación de Reynolds, espesor de capa límite incidente, relación altura/profundidad de la cavidad, y longitud característica de la perturbación en la dirección transversal). A la luz de los resultados obtenidos se proponen una serie de relaciones entre los parámetros y características de los modos principales, como por ejemplo entre el Reynolds crítico de un modo, y la longitud característica del mismo. Los resultados numéricos se contrastan con una campaña experimental, siendo la principal conclusión de dicha comparación que los modos lineales están presentes en el flujo real saturado, pero que existen diferencias notables en frecuencia entre las predicciones teóricas y los experimentos. Para intentar determinar la naturaleza de dichas diferencias se realiza una simulación numérica directa tridimensional, y se utiliza un algoritmo de DMD (descomposición dinámica de modos) para describir el proceso de saturación. ABSTRACT The problem of the flow over an open cavity has been studied in depth in the literature, both for being an interesting academical problem and due to the multitude of industrial applications, like the landing gear of aircraft, or the water deposit of firefighter airplanes. The different types of instabilities appearing in this flow studied in the literature are two: the two-dimensional shear layer modes, and the three-dimensional modes that appear in the main recirculating vortex inside the cavity. In this thesis a parametric study in the incompressible limit of the problem is presented, using the linear stability analysis known as BiGlobal. This approximation allows to obtain the global stability behaviour of the flow, and to capture both the morphological features and the characteristics of the eigenmodes of the physical problem, whether they are stable or unstable. The study presented here characterizes with great detail all the relevant eigenmodes, as well as the hypersurface of instability on the parameter space of the incompressible problem (Mach equal to zero, and variation of the Reynolds number, the incoming boundary layer thickness, the length to depth aspect ratio of the cavity and the spanwise length of the perturbation). The results allow to construct parametric relations between the characteristics of the leading eigenmodes and the parameters of the problem, like for example the one existing between the critical Reynolds number and its characteristic length. The numerical results presented here are compared with those of an experimental campaign, with the main conclusion of said comparison being that the linear eigenmode are present in the real saturated flow, albeit with some significant differences in the frequencies of the experiments and those predicted by the theory. To try to determine the nature of those differences a three-dimensional direct numerical simulation, analyzed with Dynamic Mode Decomposition algorithm, was used to describe the process of saturation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Spotlighting is one illumination field where the application of light emitting diodes (LED) creates many advantages. Commonly, the system for spot lights consists of a LED light engine and collimating secondary optics. Through angular or spatial separated emitted light from the source and imaging optical elements, a non uniform far field appears with colored rings, dots or patterns. Many feasible combinations result in very different spatial color distributions. Several combinations of three multi-chip light sources and secondary optical elements like reflectors and TIR lenses with additional facets or scattering elements were analyzed mainly regarding the color uniformity. They are assessed by the merit function Usl which was derived from human factor experiments and describes the color uniformity based on the visual perception of humans. Furthermore, the optical systems are compared concerning efficiency, peak candela and aspect ratio. Both types of optics differ in the relation between the color uniformity level and other properties. A plain reflector with a slightly color mixing light source performs adequate. The results for the TIR lenses indicate that they need additional elements for good color mixing or blended light source. The most convenient system depends on the requirements of the application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Control of linear flow instabilities has been demonstrated to be an effective theoretical flow control methodology, capable of modifying transitional flows on canonical geometries such as the plane channel and the flat-plate boundary layer. Extending the well-developed theoretical flow control techniques to flows over or through complex geometries requires addressing the issue of efficient capturing of the leading members of the global eigenspectrum pertinent to such flows. The present contribution describes state-of-the-art modal global instability analysis methodologies recently developed in our group, based on matrix formation and time-stepping, respectively. The relative performance of these algorithms is assessed on the recovery of BiGlobal and TriGlobal eigenspectra in the spanwise periodic and the cubic lid-driven cavity, respectively; the adjoint eigenspectrum in the latter flow is recovered for the first time. For three-dimensional flows without any homogeneous spatial direction, the time-stepping methodology was found to outperform the matrix-forming approach and permit recovering the leading TriGlobal eigenmodes in an three-dimensional open cavity of aspect ratio L : D : W = 5 : 1 : 1; theoretical flow control of this configuration is underway.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, we demonstrate how it is possible to sharply image multiple object points. The Simultaneous Multiple Surface (SMS) design method has usually been presented as a method to couple N wave-front pairs with N surfaces, but recent findings show that when using N surfaces, we can obtain M image points when Naspect ratio, we compare the results obtained optimizing the rotational lens and using a combination of SMS method and optimization, showing that the second approach is giving significantly smaller value of overall RMS spot diameter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El programa Europeo HORIZON2020 en Futuras Ciudades Inteligentes establece como objetivo que el 20% de la energía eléctrica sea generada a partir de fuentes renovables. Este objetivo implica la necesidad de potenciar la generación de energía eólica en todos los ámbitos. La energía eólica reduce drásticamente las emisiones de gases de efecto invernadero y evita los riesgos geo-políticos asociados al suministro e infraestructuras energéticas, así como la dependencia energética de otras regiones. Además, la generación de energía distribuida (generación en el punto de consumo) presenta significativas ventajas en términos de elevada eficiencia energética y estimulación de la economía. El sector de la edificación representa el 40% del consumo energético total de la Unión Europea. La reducción del consumo energético en este área es, por tanto, una prioridad de acuerdo con los objetivos "20-20-20" en eficiencia energética. La Directiva 2010/31/EU del Parlamento Europeo y del Consejo de 19 de mayo de 2010 sobre el comportamiento energético de edificaciones contempla la instalación de sistemas de suministro energético a partir de fuentes renovables en las edificaciones de nuevo diseño. Actualmente existe una escasez de conocimiento científico y tecnológico acerca de la geometría óptima de las edificaciones para la explotación de la energía eólica en entornos urbanos. El campo tecnológico de estudio de la presente Tesis Doctoral es la generación de energía eólica en entornos urbanos. Específicamente, la optimization de la geometría de las cubiertas de edificaciones desde el punto de vista de la explotación del recurso energético eólico. Debido a que el flujo del viento alrededor de las edificaciones es exhaustivamente investigado en esta Tesis empleando herramientas de simulación numérica, la mecánica de fluidos computacional (CFD en inglés) y la aerodinámica de edificaciones son los campos científicos de estudio. El objetivo central de esta Tesis Doctoral es obtener una geometría de altas prestaciones (u óptima) para la explotación de la energía eólica en cubiertas de edificaciones de gran altura. Este objetivo es alcanzado mediante un análisis exhaustivo de la influencia de la forma de la cubierta del edificio en el flujo del viento desde el punto de vista de la explotación energética del recurso eólico empleando herramientas de simulación numérica (CFD). Adicionalmente, la geometría de la edificación convencional (edificio prismático) es estudiada, y el posicionamiento adecuado para los diferentes tipos de aerogeneradores es propuesto. La compatibilidad entre el aprovechamiento de las energías solar fotovoltaica y eólica también es analizado en este tipo de edificaciones. La investigación prosigue con la optimización de la geometría de la cubierta. La metodología con la que se obtiene la geometría óptima consta de las siguientes etapas: - Verificación de los resultados de las geometrías previamente estudiadas en la literatura. Las geometrías básicas que se someten a examen son: cubierta plana, a dos aguas, inclinada, abovedada y esférica. - Análisis de la influencia de la forma de las aristas de la cubierta sobre el flujo del viento. Esta tarea se lleva a cabo mediante la comparación de los resultados obtenidos para la arista convencional (esquina sencilla) con un parapeto, un voladizo y una esquina curva. - Análisis del acoplamiento entre la cubierta y los cerramientos verticales (paredes) mediante la comparación entre diferentes variaciones de una cubierta esférica en una edificación de gran altura: cubierta esférica estudiada en la literatura, cubierta esférica integrada geométricamente con las paredes (planta cuadrada en el suelo) y una cubierta esférica acoplada a una pared cilindrica. El comportamiento del flujo sobre la cubierta es estudiado también considerando la posibilidad de la variación en la dirección del viento incidente. - Análisis del efecto de las proporciones geométricas del edificio sobre el flujo en la cubierta. - Análisis del efecto de la presencia de edificaciones circundantes sobre el flujo del viento en la cubierta del edificio objetivo. Las contribuciones de la presente Tesis Doctoral pueden resumirse en: - Se demuestra que los modelos de turbulencia RANS obtienen mejores resultados para la simulación del viento alrededor de edificaciones empleando los coeficientes propuestos por Crespo y los propuestos por Bechmann y Sórensen que empleando los coeficientes estándar. - Se demuestra que la estimación de la energía cinética turbulenta del flujo empleando modelos de turbulencia RANS puede ser validada manteniendo el enfoque en la cubierta de la edificación. - Se presenta una nueva modificación del modelo de turbulencia Durbin k — e que reproduce mejor la distancia de recirculación del flujo de acuerdo con los resultados experimentales. - Se demuestra una relación lineal entre la distancia de recirculación en una cubierta plana y el factor constante involucrado en el cálculo de la escala de tiempo de la velocidad turbulenta. Este resultado puede ser empleado por la comunidad científica para la mejora del modelado de la turbulencia en diversas herramientas computacionales (OpenFOAM, Fluent, CFX, etc.). - La compatibilidad entre las energías solar fotovoltaica y eólica en cubiertas de edificaciones es analizada. Se demuestra que la presencia de los módulos solares provoca un descenso en la intensidad de turbulencia. - Se demuestran conflictos en el cambio de escala entre simulaciones de edificaciones a escala real y simulaciones de modelos a escala reducida (túnel de viento). Se demuestra que para respetar las limitaciones de similitud (número de Reynolds) son necesarias mediciones en edificaciones a escala real o experimentos en túneles de viento empleando agua como fluido, especialmente cuando se trata con geometrías complejas, como es el caso de los módulos solares. - Se determina el posicionamiento más adecuado para los diferentes tipos de aerogeneradores tomando en consideración la velocidad e intensidad de turbulencia del flujo. El posicionamiento de aerogeneradores es investigado en las geometrías de cubierta más habituales (plana, a dos aguas, inclinada, abovedada y esférica). - Las formas de aristas más habituales (esquina, parapeto, voladizo y curva) son analizadas, así como su efecto sobre el flujo del viento en la cubierta de un edificio de gran altura desde el punto de vista del aprovechamiento eólico. - Se propone una geometría óptima (o de altas prestaciones) para el aprovechamiento de la energía eólica urbana. Esta optimización incluye: verificación de las geometrías estudiadas en el estado del arte, análisis de la influencia de las aristas de la cubierta en el flujo del viento, estudio del acoplamiento entre la cubierta y las paredes, análisis de sensibilidad del grosor de la cubierta, exploración de la influencia de las proporciones geométricas de la cubierta y el edificio, e investigación del efecto de las edificaciones circundantes (considerando diferentes alturas de los alrededores) sobre el flujo del viento en la cubierta del edificio objetivo. Las investigaciones comprenden el análisis de la velocidad, la energía cinética turbulenta y la intensidad de turbulencia en todos los casos. ABSTRACT The HORIZON2020 European program in Future Smart Cities aims to have 20% of electricity produced by renewable sources. This goal implies the necessity to enhance the wind energy generation, both with large and small wind turbines. Wind energy drastically reduces carbon emissions and avoids geo-political risks associated with supply and infrastructure constraints, as well as energy dependence from other regions. Additionally, distributed energy generation (generation at the consumption site) offers significant benefits in terms of high energy efficiency and stimulation of the economy. The buildings sector represents 40% of the European Union total energy consumption. Reducing energy consumption in this area is therefore a priority under the "20-20-20" objectives on energy efficiency. The Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings aims to consider the installation of renewable energy supply systems in new designed buildings. Nowadays, there is a lack of knowledge about the optimum building shape for urban wind energy exploitation. The technological field of study of the present Thesis is the wind energy generation in urban environments. Specifically, the improvement of the building-roof shape with a focus on the wind energy resource exploitation. Since the wind flow around buildings is exhaustively investigated in this Thesis using numerical simulation tools, both computational fluid dynamics (CFD) and building aerodynamics are the scientific fields of study. The main objective of this Thesis is to obtain an improved (or optimum) shape of a high-rise building for the wind energy exploitation on the roof. To achieve this objective, an analysis of the influence of the building shape on the behaviour of the wind flow on the roof from the point of view of the wind energy exploitation is carried out using numerical simulation tools (CFD). Additionally, the conventional building shape (prismatic) is analysed, and the adequate positions for different kinds of wind turbines are proposed. The compatibility of both photovoltaic-solar and wind energies is also analysed for this kind of buildings. The investigation continues with the buildingroof optimization. The methodology for obtaining the optimum high-rise building roof shape involves the following stages: - Verification of the results of previous building-roof shapes studied in the literature. The basic shapes that are compared are: flat, pitched, shed, vaulted and spheric. - Analysis of the influence of the roof-edge shape on the wind flow. This task is carried out by comparing the results obtained for the conventional edge shape (simple corner) with a railing, a cantilever and a curved edge. - Analysis of the roof-wall coupling by testing different variations of a spherical roof on a high-rise building: spherical roof studied in the litera ture, spherical roof geometrically integrated with the walls (squared-plant) and spherical roof with a cylindrical wall. The flow behaviour on the roof according to the variation of the incident wind direction is commented. - Analysis of the effect of the building aspect ratio on the flow. - Analysis of the surrounding buildings effect on the wind flow on the target building roof. The contributions of the present Thesis can be summarized as follows: - It is demonstrated that RANS turbulence models obtain better results for the wind flow around buildings using the coefficients proposed by Crespo and those proposed by Bechmann and S0rensen than by using the standard ones. - It is demonstrated that RANS turbulence models can be validated for turbulent kinetic energy focusing on building roofs. - A new modification of the Durbin k — e turbulence model is proposed in order to obtain a better agreement of the recirculation distance between CFD simulations and experimental results. - A linear relationship between the recirculation distance on a flat roof and the constant factor involved in the calculation of the turbulence velocity time scale is demonstrated. This discovery can be used by the research community in order to improve the turbulence modeling in different solvers (OpenFOAM, Fluent, CFX, etc.). - The compatibility of both photovoltaic-solar and wind energies on building roofs is demonstrated. A decrease of turbulence intensity due to the presence of the solar panels is demonstrated. - Scaling issues are demonstrated between full-scale buildings and windtunnel reduced-scale models. The necessity of respecting the similitude constraints is demonstrated. Either full-scale measurements or wind-tunnel experiments using water as a medium are needed in order to accurately reproduce the wind flow around buildings, specially when dealing with complex shapes (as solar panels, etc.). - The most adequate position (most adequate roof region) for the different kinds of wind turbines is highlighted attending to both velocity and turbulence intensity. The wind turbine positioning was investigated for the most habitual kind of building-roof shapes (flat, pitched, shed, vaulted and spherical). - The most habitual roof-edge shapes (simple edge, railing, cantilever and curved) were investigated, and their effect on the wind flow on a highrise building roof were analysed from the point of view of the wind energy exploitation. - An optimum building-roof shape is proposed for the urban wind energy exploitation. Such optimization includes: state-of-the-art roof shapes test, analysis of the influence of the roof-edge shape on the wind flow, study of the roof-wall coupling, sensitivity analysis of the roof width, exploration of the aspect ratio of the building-roof shape and investigation of the effect of the neighbouring buildings (considering different surrounding heights) on the wind now on the target building roof. The investigations comprise analysis of velocity, turbulent kinetic energy and turbulence intensity for all the cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El atrio incorporado en los edificios ha sido un recurso espacial que tempranamente se difundió a nivel global, siendo adoptado por las distintas arquitecturas locales en gran parte del mundo. Su masificación estuvo favorecida primero por la rápida evolución de la tecnología del acero y el vidrio, a partir del siglo XIX, y en segundo termino por el posterior desarrollo del hormigón armado. Otro aspecto que explica tal aceptación en la arquitectura contemporánea, es de orden social y radica en la llamativa cavidad del espacio describiendo grandes dimensiones y favoreciendo con ello, el desarrollo de una multiplicidad de usos en su interior que antes eran impensados. Al interior del atrio, la luz natural es clave en las múltiples vivencias que alberga y sea tal vez la condición ambiental más valorada, ya que entrega una sensación de bienestar al conectarnos visualmente con el ambiente natural. Por esta razón de acuerdo al método hipotético deductivo, se evaluaron los efectos de la configuración geométrica, la cubierta y la orientación en el desempeño de la iluminación natural en la planta baja, a partir un modelo extraído desde el inventario de los edificios atrio construidos en Santiago de Chile, en los últimos 30 años que fue desarrollado en el capitulo 2. El análisis cuantitativo de los edificios inventariados se elaboró en el capítulo 3, considerando las dimensiones de los atrios. Simultáneamente fueron clasificados los aspectos constructivos, los materiales y las características del ambiente interior de cada edificio. En esta etapa además, fueron identificadas las variables de estudio de las proporciones geométricas de la cavidad del atrio con los coeficientes de aspecto de las proporciones, en planta (PAR), en corte (SAR) y de la cavidad según (WI), (AR) y (RI). Del análisis de todos estos parámetros se extrajo el modelo de prueba. El enfoque del estudio del capítulo 4 fue la iluminación natural, se revisaron los conceptos y el comportamiento en el atrio, a partir de un modelo físico construido a escala para registro de la iluminancia bajo cielo soleado de la ciudad. Más adelante se construyó el modelo en ambiente virtual, relacionando las variables determinadas por la geometría de la cavidad y el cerramiento superior; examinándose de esta manera distintas transparencias, proporciones de apertura, en definitiva se evaluó un progresivo cerramiento de las aberturas, verificando el ingreso de la luz y disponibilidad a nivel de piso con la finalidad, de proveer lineamientos útiles en una primera etapa del diseño arquitectónico. Para el análisis de la iluminación natural se revisaron diferentes métodos de cálculo con el propósito de evaluar los niveles de iluminancia en un plano horizontal al interior del atrio. El primero de ellos fue el Factor de Luz Día (FLD) que corresponde, a la proporción de la iluminancia en un punto de evaluación interior respecto, la cantidad proveniente del exterior bajo cielo nublado, a partir de la cual se obtuvo resultados que revelaron la alta luminosidad del cielo nublado de la ciudad. Además fueron evaluadas las recientes métricas dinámicas que dan cuenta, de la cantidad de horas en las cuales de acuerdo a los extensos registros meteorológico de la ciudad, permitieron obtener el porcentajes de horas dentro de las cuales se cumplió el estándar de iluminancia requerido, llamado autonomía lumínica (DA) o mejor aún se permanece dentro de un rango de comodidad visual en el interior del atrio referido a la iluminancia diurna útil (UDI). En el Capítulo 5 se exponen los criterios aplicados al modelo de estudio y cada una de las variantes de análisis, además se profundizó en los antecedentes y procedencia de las fuentes de los registros climáticos utilizados en las simulaciones llevadas a cabo en el programa Daysim operado por Radiance. Que permitieron evaluar el desempeño lumínico y la precisión, de cada uno de los resultados para comprobar la disponibilidad de iluminación natural a través de una matriz. En una etapa posterior se discutieron los resultados, mediante la comparación de los datos logrados según cada una de las metodologías de simulación aplicada. Finalmente se expusieron las conclusiones y futuras lineas de trabajo, las primeras respecto el dominio del atrio de cuatro caras, la incidencia del control de cerramiento de la cubierta y la relación establecida con la altura; indicando en lo específico que las mediciones de iluminancia bajo el cielo soleado de verano, permitieron aclarar, el uso de la herramienta de simulación y método basado en el clima local, que debido a su reciente desarrollo, orienta a futuras líneas de trabajo profundizando en la evaluación dinámica de la iluminancia contrastado con monitorización de casos. ABSTRACT Atriums incorporated into buildings have been a spatial resource that quickly spread throughout the globe, being adopted by several local architecture methods in several places. Their widespread increase was highly favored, in the first place, with the rapid evolution of steel and glass technologies since the nineteen century, and, in second place, by the following development of reinforced concrete. Another issue that explains this success into contemporary architecture is associated with the social approach, and it resides in the impressive cavity that describes vast dimensions, allowing the development of multiple uses in its interior that had never been considered before. Inside the atrium, daylight it is a key element in the many experiences that involves and it is possibly the most relevant environmental factor, since it radiates a feeling of well-being by uniting us visually with the natural environment. It is because of this reason that, following the hypothetical deductive method, the effects in the performance of daylight on the floor plan were evaluated considering the geometric configuration, the deck and orientation factors. This study was based in a model withdrawn from the inventory of atrium buildings that were constructed in Santiago de Chile during the past thirty years, which will be explained later in chapter 2. The quantitative analysis of the inventory of those buildings was elaborated in chapter 3, considering the dimensions of the atriums. Simultaneously, several features such as construction aspects, materials and environmental qualities were identified inside of each building. At this stage, it were identified the variables of the geometric proportions of the atrium’s cavity with the plan aspect ratio of proportions in first plan (PAR), in section (SAR) and cavity according to well index (WI), aspect ratio (AR) and room index (RI). An experimental model was obtained from the analysis of all the mentioned parameters. The main focus of the study developed in chapter 4 is daylight. The atrium’s concept and behavior were analyzed from a physical model built under scale to register the illuminances under clear, sunny sky of the city. Later on, this physical model was built in a virtual environment, connecting the variables determined by the geometry of the cavity and the superior enclosure, allowing the examination of transparencies and opening proportions. To summarize, this stage consisted on evaluating a progressive enclosure of the openings, checking the access of natural light and its availability at the atrium floor, in an effort to provide useful guidelines during the first stage of the architectural design. For the analysis of natural lighting, several calculations methods were used in order to determine the levels of illuminances in a horizontal plane inside of the atrium. The first of these methods is the Daylight Factor (DF), which consists in the proportion of light in an evaluation interior place with the amount of light coming from the outside in a cloudy day. Results determined that the cloudy sky of the city has high levels of luminosity. In addition, the recent dynamic metrics were evaluated which reflects the hours quantity. According to the meteorological records of the city’s climate, the standard of illuminance- a standard measure called Daylight Autonomy (DA) – was met. This is even better when the results stay in the line of visual convenience within the atrium, which is referred to as Useful Daylight Illuminance (UDI). In chapter 5, it was presented the criteria applied to the study model and on each of the variants of the analysis. Moreover, the information of the climate records used for the simulations - carried out in the Daysim program managed by Radiance – are detailed. These simulations allowed the observation of the daylight performance and the accuracy of each of the results to confirm the availability of natural light through a matrix. In a later stage, the results were discussed comparing the collected data in each of the methods of simulation used. Finally, conclusions and further discussion are presented. Overall, the four side atrium’s domain and the effect of the control of the cover’s enclosure. Specifically, the measurements of the daylight under summer’s clear, sunny sky allowing clarifying the use of the simulation tool and the method based on the local climate. This method allows defining new and future lines of work deepening on the dynamic of the light in contrast with the monitoring of the cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En la última década la potencia instalada de energía solar fotovoltaica ha crecido una media de un 49% anual y se espera que alcance el 16%del consumo energético mundial en el año 2050. La mayor parte de estas instalaciones se corresponden con sistemas conectados a la red eléctrica y un amplio porcentaje de ellas son instalaciones domésticas o en edificios. En el mercado ya existen diferentes arquitecturas para este tipo de instalaciones, entre las que se encuentras los módulos AC. Un módulo AC consiste en un inversor, también conocido como micro-inversor, que se monta en la parte trasera de un panel o módulo fotovoltaico. Esta tecnología ofrece modularidad, redundancia y la extracción de la máxima potencia de cada panel solar de la instalación. Además, la expansión de esta tecnología posibilitará una reducción de costes asociados a las economías de escala y a la posibilidad de que el propio usuario pueda componer su propio sistema. Sin embargo, el micro-inversor debe ser capaz de proporcionar una ganancia de tensión adecuada para conectar el panel solar directamente a la red, mientras mantiene un rendimiento aceptable en un amplio rango de potencias. Asimismo, los estándares de conexión a red deber ser satisfechos y el tamaño y el tiempo de vida del micro-inversor son factores que han de tenerse siempre en cuenta. En esta tesis se propone un micro-inversor derivado de la topología “forward” controlado en el límite entre los modos de conducción continuo y discontinuo (BCM por sus siglas en inglés). El transformador de la topología propuesta mantiene la misma estructura que en el convertidor “forward” clásico y la utilización de interruptores bidireccionales en el secundario permite la conexión directa del inversor a la red. Asimismo el método de control elegido permite obtener factor de potencia cercano a la unidad con una implementación sencilla. En la tesis se presenta el principio de funcionamiento y los principales aspectos del diseño del micro-inversor propuesto. Con la idea de mantener una solución sencilla y de bajo coste, se ha seleccionado un controlador analógico que está originalmente pensado para controlar un corrector del factor de potencia en el mismo modo de conducción que el micro-inversor “forward”. La tesis presenta las principales modificaciones necesarias, con especial atención a la detección del cruce por cero de la corriente (ZCD por sus siglas en inglés) y la compatibilidad del controlador con la inclusión de un algoritmo de búsqueda del punto de máxima potencia (MPPT por sus siglas en inglés). Los resultados experimentales muestran las limitaciones de la implementación elegida e identifican al transformador como el principal contribuyente a las pérdidas del micro-inversor. El principal objetivo de esta tesis es contribuir a la aplicación de técnicas de control y diseño de sistemas multifase en micro-inversores fotovoltaicos. En esta tesis se van a considerar dos configuraciones multifase diferentes aplicadas al micro-inversor “forward” propuesto. La primera consiste en una variación con conexión paralelo-serie que permite la utilización de transformadores con una relación de vueltas baja, y por tanto bien acoplados, para conseguir una ganancia de tensión adecuada con un mejor rendimiento. Esta configuración emplea el mismo control BCM cuando la potencia extraída del panel solar es máxima. Este método de control implica que la frecuencia de conmutación se incrementa considerablemente cuando la potencia decrece, lo que compromete el rendimiento. Por lo tanto y con la intención de mantener unos bueno niveles de rendimiento ponderado, el micro-inversor funciona en modo de conducción discontinuo (DCM, por sus siglas en inglés) cuando la potencia extraía del panel solar es menor que la máxima. La segunda configuración multifase considerada en esta tesis es la aplicación de la técnica de paralelo con entrelazado. Además se han considerado dos técnicas diferentes para decidir el número de fases activas: dependiendo de la potencia continua extraída del panel solar y dependiendo de la potencia instantánea demandada por el micro-inversor. La aplicación de estas técnicas es interesante en los sistemas fotovoltaicos conectados a la red eléctrica por la posibilidad que brindan de obtener un rendimiento prácticamente plano en un amplio rango de potencia. Las configuraciones con entrelazado se controlan en DCM para evitar la necesidad de un control de corriente, lo que es importante cuando el número de fases es alto. Los núcleos adecuados para todas las configuraciones multifase consideradas se seleccionan usando el producto de áreas. Una vez seleccionados los núcleos se ha realizado un diseño detallado de cada uno de los transformadores. Con la información obtenida de los diseños y los resultados de simulación, se puede analizar el impacto que el número de transformadores utilizados tiene en el tamaño y el rendimiento de las distintas configuraciones. Los resultados de este análisis, presentado en esta tesis, se utilizan posteriormente para comparar las distintas configuraciones. Muchas otras topologías se han presentado en la literatura para abordar los diferentes aspectos a considerar en los micro-inversores, que han sido presentados anteriormente. La mayoría de estas topologías utilizan un transformador de alta frecuencia para solventar el salto de tensión y evitar problemas de seguridad y de puesta a tierra. En cualquier caso, es interesante evaluar si topologías sin aislamiento galvánico son aptas para su utilización como micro-inversores. En esta tesis se presenta una revisión de inversores con capacidad de elevar tensión, que se comparan bajo las mismas especificaciones. El objetivo es proporcionar la información necesaria para valorar si estas topologías son aplicables en los módulos AC. Las principales contribuciones de esta tesis son: • La aplicación del control BCM a un convertidor “forward” para obtener un micro-inversor de una etapa sencillo y de bajo coste. • La modificación de dicho micro-inversor con conexión paralelo-series de transformadores que permite reducir la corriente de los semiconductores y una ganancia de tensión adecuada con transformadores altamente acoplados. • La aplicación de técnicas de entrelazado y decisión de apagado de fases en la puesta en paralelo del micro-inversor “forward”. • El análisis y la comparación del efecto en el tamaño y el rendimiento del incremento del número de transformadores en las diferentes configuraciones multifase. • La eliminación de las medidas y los lazos de control de corriente en las topologías multifase con la utilización del modo de conducción discontinuo y un algoritmo MPPT sin necesidad de medida de corriente. • La recopilación y comparación bajo las mismas especificaciones de topologías inversoras con capacidad de elevar tensión, que pueden ser adecuadas para la utilización como micro-inversores. Esta tesis está estructurada en seis capítulos. El capítulo 1 presenta el marco en que se desarrolla la tesis así como el alcance de la misma. En el capítulo 2 se recopilan las topologías existentes de micro-invesores con aislamiento y aquellas sin aislamiento cuya implementación en un módulo AC es factible. Asimismo se presenta la comparación entre estas topologías bajo las mismas especificaciones. El capítulo 3 se centra en el micro-inversor “forward” que se propone originalmente en esta tesis. La aplicación de las técnicas multifase se aborda en los capítulos 4 y 5, en los que se presentan los análisis en función del número de transformadores. El capítulo está orientado a la propuesta paralelo-serie mientras que la configuración con entrelazado se analiza en el capítulo 5. Por último, en el capítulo 6 se presentan las contribuciones de esta tesis y los trabajos futuros. ABSTRACT In the last decade the photovoltaic (PV) installed power increased with an average growth of 49% per year and it is expected to cover the 16% of the global electricity consumption by 2050. Most of the installed PV power corresponds to grid-connected systems, with a significant percentage of residential installations. In these PV systems, the inverter is essential since it is the responsible of transferring into the grid the extracted power from the PV modules. Several architectures have been proposed for grid-connected residential PV systems, including the AC-module technology. An AC-module consists of an inverter, also known as micro-inverter, which is attached to a PV module. The AC-module technology offers modularity, redundancy and individual MPPT of each module. In addition, the expansion of this technology will enable the possibility of economies of scale of mass market and “plug and play” for the user, thus reducing the overall cost of the installation. However, the micro-inverter must be able to provide the required voltage boost to interface a low voltage PV module to the grid while keeping an acceptable efficiency in a wide power range. Furthermore, the quality standards must be satisfied and size and lifetime of the solutions must be always considered. In this thesis a single-stage forward micro-inverter with boundary mode operation is proposed to address the micro-inverter requirements. The transformer in the proposed topology remains as in the classic forward converter and bidirectional switches in the secondary side allows direct connection to the grid. In addition the selected control strategy allows high power factor current with a simple implementation. The operation of the topology is presented and the main design issues are introduced. With the intention to propose a simple and low-cost solution, an analog controller for a PFC operated in boundary mode is utilized. The main necessary modifications are discussed, with the focus on the zero current detection (ZCD) and the compatibility of the controller with a MPPT algorithm. The experimental results show the limitations of the selected analog controller implementation and the transformer is identified as a main losses contributor. The main objective of this thesis is to contribute in the application of control and design multiphase techniques to the PV micro-inverters. Two different multiphase configurations have been applied to the forward micro-inverter proposed in this thesis. The first one consists of a parallel-series connected variation which enables the use of low turns ratio, i.e. well coupled, transformers to achieve a proper voltage boost with an improved performance. This multiphase configuration implements BCM control at maximum load however. With this control method the switching frequency increases significantly for light load operation, thus jeopardizing the efficiency. Therefore, in order to keep acceptable weighted efficiency levels, DCM operation is selected for low power conditions. The second multiphase variation considered in this thesis is the interleaved configuration with two different phase shedding techniques: depending on the DC power extracted from the PV panel, and depending on the demanded instantaneous power. The application of interleaving techniques is interesting in PV grid-connected inverters for the possibility of flat efficiency behavior in a wide power range. The interleaved variations of the proposed forward micro-inverter are operated in DCM to avoid the current loop, which is important when the number of phases is large. The adequate transformer cores for all the multiphase configurations are selected according to the area product parameter and a detailed design of each required transformer is developed. With this information and simulation results, the impact in size and efficiency of the number of transformer used can be assessed. The considered multiphase topologies are compared in this thesis according to the results of the introduced analysis. Several other topological solutions have been proposed to solve the mentioned concerns in AC-module application. The most of these solutions use a high frequency transformer to boost the voltage and avoid grounding and safety issues. However, it is of interest to assess if the non-isolated topologies are suitable for AC-module application. In this thesis a review of transformerless step-up inverters is presented. The compiled topologies are compared using a set benchmark to provide the necessary information to assess whether non-isolated topologies are suitable for AC-module application. The main contributions of this thesis are: • The application of the boundary mode control with constant off-time to a forward converter, to obtain a simple and low-cost single-stage forward micro-inverter. • A modification of the forward micro-inverter with primary-parallel secondary-series connected transformers to reduce the current stress and improve the voltage gain with highly coupled transformers. •The application of the interleaved configuration with different phase shedding strategies to the proposed forward micro-inverter. • An analysis and comparison of the influence in size and efficiency of increasing the number of transformers in the parallel-series and interleaved multiphase configurations. • Elimination of the current loop and current measurements in the multiphase topologies by adopting DCM operation and a current sensorless MPPT. • A compilation and comparison with the same specifications of suitable non-isolated step-up inverters. This thesis is organized in six chapters. In Chapter 1 the background of single-phase PV-connected systems is discussed and the scope of the thesis is defined. Chapter 2 compiles the existing solutions for isolated micro-inverters and transformerless step-up inverters suitable for AC-module application. In addition, the most convenient non-isolated inverters are compared using a defined benchmark. Chapter 3 focuses on the originally proposed single-stage forward micro-inverter. The application of multiphase techniques is addressed in Chapter 4 and Chapter 5, and the impact in different parameters of increasing the number of phases is analyzed. In Chapter 4 an original primary-parallel secondary-series variation of the forward micro-inverter is presented, while Chapter 5 focuses on the application of the interleaved configuration. Finally, Chapter 6 discusses the contributions of the thesis and the future work.