906 resultados para L33 - Comparison of Public and Private Enterprises
Resumo:
Introduction: Although the pig is a standard model for the evaluation of various diseases in humans, including coagulopathy, it is not clear whether results in animals can be extrapolated to man.Materials and methods: In 75 anesthetized pigs, we assessed reagent-supported thrombelastometry (ExTEM (R)), platelet-blocked thrombelastometry (FibTEM (R)), and aprotinin thrombelastometry (ApTEM (R)). Results were compared to values from 13 anesthetized humans.Results (median, 95% CI): ExTEM (R) : While clot strength was comparable in pigs (66 mm, 65-67 mm) and in humans (64 mm, 60-68 mm; NS), clotting time in animals was longer (pigs 64 s, 62-66 s; humans 55 s, 49-71 s; P<0.05) and clot formation time shorter (pigs 52 s, 49-54 s; humans 83 s, 67-98 s, P<0.001). The clot lysis index at 30 minutes was lower in animals (96.9%, 95.1-97.3%) than in humans (99.5%, 98.6-99.9%; P<0.001). ApTEM (R) showed no hyperfibrinolysis in animals. Modification of the anesthesia protocol in animals resulted in significant ExTEM (R) changes. FibTEM (R) : Complete platelet inhibition yielded significantly higher platelet contribution to clot strength in pigs (79%, 76-81%) than in humans (73%, 71-77%; P<0.05), whereas fibrinogen contribution to clot strength was higher in humans (27%, 24-29%) than in animals (21%, 19-24%; P<0.05).Conclusions: Maximum clot firmness is comparable in human and porcine blood. However, clot lysis, platelet and fibrinogen contribution to clot strength, as well as initiation and propagation of clotting, are considerably different between pigs and humans. In addition, anesthesic drugs seem to influence thrombelastometry in animals. Accordingly, coagulation abnormalities in pigs subjected to diseases may not necessarily represent the coagulation profile in sick patients. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
We would like to comment this study recently published in JFS. It is a short technical note proposing an artificial aging technique for the dating of ballpoint pen inks. This is a very difficult and controversial topic, and we are worried about the nature of this paper. The authors propose several ideas to differentiate fast aging and slow aging inks, but their experimental data is not validly represented and/or discussed. The data is insufficient to draw any conclusions about any potential of the method for ink dating purposes. This lack of information on the subject must be filled before proposing such methods for practical caseworks. These are preliminary and unconvincing results from development research performed in a laboratory on controlled samples without due warnings about potential shortcomings. They cannot be used or even compared to results obtained in real situations on uncontrolled specimens of limited size, unknown composition and undefined storage conditions. This can leave an undeserved feeling that these methods are ready for implementation when the task of ensuring their scientific validity is still far away.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Resumo:
PURPOSE: Hypoxia is known to reduce maximal oxygen uptake (VO(2max)) more in trained than in untrained subjects in several lowland sports. Ski mountaineering is practiced mainly at altitude, so elite ski mountaineers spend significantly longer training duration at altitude than their lower-level counterparts. Since acclimatization in hypobaric hypoxia is effective, the authors hypothesized that elite ski mountaineers would exhibit a VO2max decrement in hypoxia similar to that of recreational ski mountaineers. METHODS: Eleven elite (E, Swiss national team) and 12 recreational (R) ski mountaineers completed an incremental treadmill test to exhaustion in normobaric hypoxia (H, 3000 m, F(1)O(2) 14.6% ± 0.1%) and in normoxia (N, 485 m, F(1)O(2) 20.9% ± 0.0%). Pulse oxygen saturation in blood (SpO(2)), VO(2max), minute ventilation, and heart rate were recorded. RESULTS: At rest, hypoxic ventilatory response was higher (P < .05) in E than in R (1.4 ± 1.9 vs 0.3 ± 0.6 L · min⁻¹ · kg⁻¹). At maximal intensity, SpO(2) was significantly lower (P < .01) in E than in R, both in N (91.1% ± 3.3% vs 94.3% ± 2.3%) and in H (76.4% ± 5.4% vs 82.3% ± 3.5%). In both groups, SpO(2) was lower (P < .01) in H. Between N and H, VO(2max) decreased to a greater extent (P < .05) in E than in R (-18% and -12%, P < .01). In E only, the VO(2max) decrement was significantly correlated with the SpO(2) decrement (r = .74, P < .01) but also with VO(2max) measured in N (r = .64, P < .05). CONCLUSION: Despite a probable better acclimatization to altitude, VO(2max) was more reduced in E than in R ski mountaineers, confirming previous results observed in lowlander E athletes.
Resumo:
An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.
Resumo:
The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for these parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.
Resumo:
This letter presents a comparison between threeFourier-based motion compensation (MoCo) algorithms forairborne synthetic aperture radar (SAR) systems. These algorithmscircumvent the limitations of conventional MoCo, namelythe assumption of a reference height and the beam-center approximation.All these approaches rely on the inherent time–frequencyrelation in SAR systems but exploit it differently, with the consequentdifferences in accuracy and computational burden. Aftera brief overview of the three approaches, the performance ofeach algorithm is analyzed with respect to azimuthal topographyaccommodation, angle accommodation, and maximum frequencyof track deviations with which the algorithm can cope. Also, ananalysis on the computational complexity is presented. Quantitativeresults are shown using real data acquired by the ExperimentalSAR system of the German Aerospace Center (DLR).
Resumo:
This study aimed to evaluate the use of conventional polymerase chain reaction (cPCR) and real-time quantitative PCR (qPCR) in the diagnosis of human strongyloidiasis from stool samples in tropical areas. Stool samples were collected from individuals and were determined to be positive for Strongyloides stercoralis (group I), negative for S. stercoralis (group II) and positive for other enteroparasite species (group III). DNA specific to S. stercoralis was found in 76.7% of group I samples by cPCR and in 90% of group I samples by qPCR. The results show that molecular methods can be used as alternative tools for detecting S. stercoralis in human stool samples in tropical areas.
Resumo:
High-resolution tomographic imaging of the shallow subsurface is becoming increasingly important for a wide range of environmental, hydrological and engineering applications. Because of their superior resolution power, their sensitivity to pertinent petrophysical parameters, and their far reaching complementarities, both seismic and georadar crosshole imaging are of particular importance. To date, corresponding approaches have largely relied on asymptotic, ray-based approaches, which only account for a very small part of the observed wavefields, inherently suffer from a limited resolution, and in complex environments may prove to be inadequate. These problems can potentially be alleviated through waveform inversion. We have developed an acoustic waveform inversion approach for crosshole seismic data whose kernel is based on a finite-difference time-domain (FDTD) solution of the 2-D acoustic wave equations. This algorithm is tested on and applied to synthetic data from seismic velocity models of increasing complexity and realism and the results are compared to those obtained using state-of-the-art ray-based traveltime tomography. Regardless of the heterogeneity of the underlying models, the waveform inversion approach has the potential of reliably resolving both the geometry and the acoustic properties of features of the size of less than half a dominant wavelength. Our results do, however, also indicate that, within their inherent resolution limits, ray-based approaches provide an effective and efficient means to obtain satisfactory tomographic reconstructions of the seismic velocity structure in the presence of mild to moderate heterogeneity and in absence of strong scattering. Conversely, the excess effort of waveform inversion provides the greatest benefits for the most heterogeneous, and arguably most realistic, environments where multiple scattering effects tend to be prevalent and ray-based methods lose most of their effectiveness.
Resumo:
This contribution compares existing and newly developed techniques for geometrically representing mean-variances-kewness portfolio frontiers based on the rather widely adapted methodology of polynomial goal programming (PGP) on the one hand and the more recent approach based on the shortage function on the other hand. Moreover, we explain the working of these different methodologies in detail and provide graphical illustrations. Inspired by these illustrations, we prove a generalization of the well-known two fund separation theorem from traditionalmean-variance portfolio theory.