987 resultados para Irrigation by sprinkler
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dogs' teeth with apical periodontitis were treated endodontically, Dakin's solution being used in an experimental group as the irrigation solution, and camphorated paramonochlorophenol as an intracanal dressing. For a second group of teeth, the irrigation solution used was physiologic saline, dry cotton only being placed into the pulpal chamber to take the place of an intracanal dressing. In a second visit, overinstrumentation and a new application of the same kind of dressing were performed, the root canals being then filled with gutta-percha cones and zinc oxide-eugenol cement. Other specimens were treated, in one visit, where physiologic saline or Dakin's solution were the irrigation solutions. The animals were sacrificed 6 months after the obturation of the root canals. Histologic exams showed better results for the experimental group where Dakin's solution and camphorated paramonochlorophenol had been used, with signs of repair characterized by newly formed cementum and bone tissue, as well as a marked reduction in size of the periapical lesions. No differences were seen in the results with physiologic saline or Dakin's solution as irrigants.
Resumo:
Background The aim of this study was to compare antimicrobial photodynamic therapy (aPDT) as an adjunctive treatment to scaling and root planing (SRP) for induced periodontitis in nicotine-modified rats. Material & Methods A total of 240 rats were evenly divided into two groups: C – saline solution treatment; N – nicotine treatment. Periodontal disease was induced in both groups at the first mandibular molar. After 7 days, the ligature was removed. All animals were submitted to SRP and were divided according to the following treatments: SRP – irrigation with saline solution; Toluidine Blue-O (TBO) – irrigation with phenothiazinium dye (100 μg/ml); LLLT – laser irradiation (660 nm; 0.03 W; 4 J); and aPDT – TBO and laser irradiation. Ten animals in each group/treatment were euthanized at 7, 15 and 30 days. The histometric and immunohistochemical values were statistically analysed. Results Intragroup analysis demonstrated that in both groups the aPDT treatment resulted in lower bone loss (BL) when compared to SRP in all experimental periods. Intergroup analysis demonstrated that aPDT treatment resulted in lower BL in Group N than in Group C treated with SRP in all experimental periods. Conclusion Antimicrobial photodynamic therapy was an effective adjunctive treatment to SRP for induced periodontitis in nicotine-modified rats.
Resumo:
This work aimed to assess the bacteriological quality of water used in the irrigation of vegetable gardens in the municipalities of Araraquara, Boa Esperança do Sul and Ibitinga, São Paulo, Brazil. A total of 80 samples of water used in the irrigation of 40 vegetable gardens were analyzed, two samples coming from each vegetable garden. They were collected at the same site in different months, which resulted in two sample collection groups. The most probable number (MPN/100mL) of total coliforms, thermotolerant coliforms and enterococci was identifi ed by means of the multiple tube technique. The analysis of the fi rst group samples showed quantities of thermotolerant coliforms above the amount allowed by current law for irrigation water (CONAMA Resolution n. 357) in nine cases. The owners of those vegetable gardens were then instructed in water disinfection procedures. After the analysis of the second group samples, it was noticed that only one sample did not meet the quality standards, and it was collected at a site where no disinfection procedure had been carried out. According to the results, 77.5% of the vegetable gardens were using water whose samples meet the quality standards. After the owners were instructed with regard to disinfection procedures, that number changed to 97.5%, which confi rms the importance of controlling and supervising irrigation water quality
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Eucalyptus plantations occupy almost 20 million ha worldwide and exceed 3.7 million ha in Brazil alone. Improved genetics and silviculture have led to as much as a three-fold increase in productivity in Eucalyptus plantations in Brazil and the large land area occupied by these highly productive ecosystems raises concern over their effect on local water supplies. As part of the Brazil Potential Productivity Project, we measured water use of Eucalyptus grandis x urophylla clones in rainfed and irrigated stands in two plantations differing in productivity. The Aracruz (lower productivity) site is located in the state of Espirito Santo and the Veracel (higher productivity) site in Bahia state. At each plantation, we measured stand water use using homemade sap flow sensors and a calibration curve using the clones and probes we utilized in the study. We also quantified changes in growth, leaf area and water use efficiency (the amount of wood produced per unit of water transpired). Measurements were conducted for 1 year during 2005 at Aracruz and from August through December 2005 at Veracel. Transpiration at both sites was high compared to other studies but annual estimates at Aracruz for the rainfed treatment compared well with a process model calibrated for the Aracruz site (within 10%). Annual water use at Aracruz was 1394 mm in rainfed treatments versus 1779 mm in irrigated treatments and accounted for approximately 67% and 58% of annual precipitation and irrigation inputs respectively. Increased water use in the irrigated stands at Aracruz was associated with higher sapwood area, leaf area index and transpiration per unit leaf area but there was no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency at the Aracruz site was also not influenced by irrigation and was similar to the rainfed treatment. During the period of overlapping measurements, the response to irrigation treatments at the more productive Veracel site was similar to Aracruz. Stand water use at the Veracel site totaled 975 mm and 1102 mm in rainfed and irrigated treatments during the 5-month measurement period respectively. Irrigated stands at Veracel also had higher leaf area with no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency was also unaffected by irrigation at Veracel. Results from this and other studies suggest that improved resource availability does not negatively impact water use efficiency but increased productivity of these plantations is associated with higher water use and should be given consideration during plantation management decision making processes aimed at increasing productivity. Published by Elsevier B.V.
Resumo:
Subsurface drip irrigation that uses an emitter protection system to avoid its clogging by roots and soil particles may be viable compared to a conventional system. The objective of this work was to evaluate the performance of a system with emitter protection, and to compare the results with a system that uses a conventional emitter for subsurface drip irrigation. In the system with protection an inexpensive materials polyethylene hose, microtube, connector, and a dripper to control the flow rate were used; and, in the conventional system a commercial emitter was used. After 12 months of evaluation, the system with protector showed good performance, with relative average flow rate of 0.97 and 0.98 in pots with and without crop, respectively, showing no clogging problems and lower cost. In conventional system relative flow rate of 0.51 and 0.98 were observed in pots with and without crop, respectively, also clogging degree by roots of 49.22%, and emitters with soil inside was observed. Thus, the use of emitter with protection presented feasibility for subsurface drip irrigation, under conditions used in this research.