706 resultados para Implantssupported Prostheses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. Methods: A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. Results: According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Conclusion: Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is recommended when reoperation is indicated, without waiting for clinical manifestations of structural valve disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Anatomical total shoulder arthroplasty (TSA) for glenohumeral osteoarthritis (OA) and severe posterior glenoid wear may entail early postoperative complications (recurrence of posterior subluxation, glenoid loosening). To avoid these mechanical problems, reverse shoulder arthroplasty (RSA) has recently been proposed, mainly for its intrinsic stability. Our purpose was to present the results of TSA and RSA in glenohumeral OA with posterior glenoid wear of at least 20°. HYPOTHESIS: By virtue of its constrained design, RSA could prevent recurrence of posterior subluxation and limit the occurrence of mechanical complications. MATERIALS AND METHODS: A consecutive series of 23 patients (27 shoulders) were treated for glenohumeral OA with total shoulder prostheses: 19 TSAs and 8 RSAs. Mean age was 70years (range, 47-85years), mean retroversion angle 28° (20°-50°) and mean subluxation index 74% (57-89%). Constant Score, Subjective Shoulder Value (SSV), QuickDASH and Simple Shoulder Test (SST) were measured, and radiological examinations were performed at a mean follow-up of 52months (24-95months). RESULTS: TSA and RSA patients respectively displayed Constant Scores of 65 and 65, SSV of 79% and 74%, QuickDASH of 16 and 27, and SST of 88 and 78. Two patients underwent surgical revision of TSA because of glenoid loosening; 52% of TSA patients presented complete radiolucent lines and 11% recurrence of posterior subluxation. CONCLUSION: Complications are frequently observed after shoulder arthroplasty for OA with severe glenoid retroversion. RSA could be an alternative to TSA for selected patients, independently of rotator cuff status. Studies on RSA in this specific indication with longer follow-up are now needed. LEVEL OF EVIDENCE: Level IV; retrospective case series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Medialization laryngoplasty was performed in 25 patients between 1993 and 1997. The underlying pathology resulting in glottal incompetence was vocal cord paralysis in 22 patients and vocal cord bowing in 3 patients. Two types of implants were used: self-carved Proplast in 19 patients and prefabricated hydroxyapatite prostheses in 6 patients. Preoperative and postoperative results were compared in terms of dysphagia, vocal quality as graded by three experienced voice specialists, and computer measurements of the glottal gap. All patients showed improvement both subjectively and on the objective measurements used. Swallowing returned to normal in all patients who had isolated recurrent laryngeal nerve paralysis. The voice improved in all patients but was rarely judged as entirely normal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: When we examined a previously published prospective multi-center clinical trial in which complete denture-wearers were followed over a period of 2 years, we found that about 30% of the variability in the clinical wear data of denture teeth was due to unknown characteristics of the subjects. In the second part of the study, we try to identify which patient- and therapy-related factors may explain some of this variability. METHODS: The clinical wear data of denture teeth at different recall times (6, 12, 18, 24 months) in 89 subjects (at baseline) were correlated with the following parameters, which may all have an influence on the wear of denture teeth: age, gender, bruxism as reported by the subjects, number of prostheses used so far, time since last extraction, smoking, fit of dentures as judged by the subject and the clinician, average denture wearing time and wearing of denture during the night. To evaluate the influence of the different patient- and therapy-related variables, both a univariate analysis (one extra factor to the model) and a multivariate analysis were carried out using linear mixed models with the variable Log mean as the outcome. RESULTS: None of the patient- and therapy-related parameters showed a statistically significant effect on the wear of denture teeth. There was, however, a trend for women to show less wear compared to men and a trend of decreasing wear with increasing age. SIGNIFICANCE: Further research is required to identify the factors which are responsible for the high variability observed between the subjects regarding clinical wear data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the frequency and the outcome of patients suffering from rheumatoid arthritis in which calcium pyrophosphate dihydrate (CPPD) crystal deposits were found to coexist in synovial fluid analysis. Such association was more frequent than previously believed with CPPD crystals found in 25.8% of 93 patients with rheumatoid arthritis. As a group, a trend toward a worse outcome was suggested by more frequent prostheses of the lower limb.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term success rate and complications of nonpenetrating deep sclerectomy with collagen implant in open-angle glaucoma. PATIENTS AND METHODS: Clinical, prospective, monocentric, nonrandomized, unmasked study on 105 patients with medically uncontrolled glaucoma. A standard procedure deep sclerectomy with collagen implant was performed. Complete examinations were performed before surgery and postoperatively at 1 and 7 days; 1, 2, 3, 6, 9, and 12 months and then every 6 months during the 10 following years. RESULTS: The mean follow-up was 101.5+/-43.1 (3 to 144) months [mean+/-SD, (range)]. The preoperative intraocular pressure (IOP) was 26.8+/-7.7 (14 to 52) mm Hg and the best-corrected visual acuity 0.71+/-0.33 (0.02 to 1.5). Ten years after surgery IOP was 12.2+/-4.7 (6 to 20) mm Hg and best-corrected visual acuity 0.63+/-0.34 (0.01 to 1.2) (number of remaining patients=52). The mean number of medications per patient went from 2.3+/-0.7 (1 to 4) down to 1.3+/-1.1 (0 to 3). An IOP <or=21 mm Hg without medication was achieved in 47.7% patients and in 89% with or without treatment. One major complication was reported. Goniopuncture was performed in 61 eyes (59.8%), 5-fluorouracil treatment given to 25 patients postoperatively and included needling (n=5). CONCLUSIONS: On the basis of a 10-year follow-up deep sclerectomy with collagen implant demonstrated its efficacy in controlling IOP with few postoperative complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: It has been hypothesized that bacterial biofilms on breast implants may cause chronic inflammation leading to capsular contracture. The association between bacterial biofilms of removed implants and capsular contracture was investigated. METHODS: Breast implants explanted between 2006 and 2010 at five participating centres for plastic and reconstructive surgery were investigated by sonication. Bacterial cultures derived from sonication were correlated with patient, surgical and implant characteristics, and the degree of capsular contracture. RESULTS: The study included 121 breast implants from 84 patients, of which 119 originated from women and two from men undergoing gender reassignment. Some 50 breast prostheses were implanted for reconstruction, 48 for aesthetic reasons and 23 implants were used as temporary expander devices. The median indwelling time was 4·0 (range 0·1-32) years for permanent implants and 3 (range 1-6) months for temporary devices. Excluding nine implants with clinical signs of infection, sonication cultures were positive in 40 (45 per cent) of 89 permanent implants and in 12 (52 per cent) of 23 temporary devices. Analysis of permanent implants showed that a positive bacterial culture after sonication correlated with the degree of capsular contracture: Baker I, two of 11 implants; Baker II, two of ten; Baker III, nine of 23; and Baker IV, 27 of 45 (P < 0·001). The most frequent organisms were Propionibacterium acnes (25 implants) and coagulase-negative staphylococci (21). CONCLUSION: Sonication cultures correlated with the degree of capsular contracture, indicating the potential causative role of bacterial biofilms in the pathogenesis of capsular contracture. Registration number: NCT01138891 (http://www.clinicaltrials.gov).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Cultures have limited sensitivity in the diagnosis of prosthetic joint infection (PJI), especially in low-grade infections. We assessed the value of multiplex PCR in differentiating PJI from aseptic failure (AF). METHODS: Included were patients in whom the joint prosthesis was removed and submitted for sonication. The resulting sonication fluid was cultured and investigated by multiplex PCR, and compared with periprosthetic tissue culture. RESULTS: Among 86 explanted prostheses (56 knee, 25 hip, 3 elbow and 2 shoulder prostheses), AF was diagnosed in 62 cases (72%) and PJI in 24 cases (28%). PJI was more common detected by multiplex PCR (n=23, 96%) than by periprosthetic tissue (n=17, 71%, p=0.031) or sonication fluid culture (n=16, 67%, p=0.016). Among 12 patients with PJI who previously received antibiotics, periprosthetic tissue cultures were positive in 8 cases (67%), sonication fluid cultures in 6 cases (50%) and multiplex PCR in 11 cases (92%). In AF cases, periprosthetic tissue grew organisms in 11% and sonication fluid in 10%, whereas multiplex PCR detected no organisms. CONCLUSIONS: Multiplex PCR of sonication fluid demonstrated high sensitivity (96%) and specificity (100%) for diagnosing PJI, providing good discriminative power towards AF, especially in patients previously receiving antibiotics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous drug delivery systems (DDSs) can be used as intraocular tools to provide a sustained and calibrated release for a specific drug. Great progress has been made on the design, biocompatibility, bioavailability, and efficacy of DDSs. Although several of them are undergoing clinical trials, a few are already on the market and could be of a routine use in clinical practice. Moreover, miniaturization of the implants makes them less and less traumatic for the eye tissues and some DDSs are now able to target certain cells or tissues specifically. An overview of ocular implants with therapeutic application potentials is provided.