973 resultados para Implantable Infusion pumps
Resumo:
Patients with an implantable cardioverter defibrillator (ICD) show clinically relevant depression and anxiety, but little is known about their levels of posttraumatic stress. We assessed chronic posttraumatic stress attributable to a traumatic cardiac event and its predictors in patients at two time points after ICD placement.
Resumo:
To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.
Resumo:
A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.
Resumo:
Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document, (Table see text). Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.
Resumo:
The objective of this study was to assess a pharmacokinetic algorithm to predict ketamine plasma concentration and drive a target-controlled infusion (TCI) in ponies. Firstly, the algorithm was used to simulate the course of ketamine enantiomers plasma concentrations after the administration of an intravenous bolus in six ponies based on individual pharmacokinetic parameters obtained from a previous experiment. Using the same pharmacokinetic parameters, a TCI of S-ketamine was then performed over 120 min to maintain a concentration of 1 microg/mL in plasma. The actual plasma concentrations of S-ketamine were measured from arterial samples using capillary electrophoresis. The performance of the simulation for the administration of a single bolus was very good. During the TCI, the S-ketamine plasma concentrations were maintained within the limit of acceptance (wobble and divergence <20%) at a median of 79% (IQR, 71-90) of the peak concentration reached after the initial bolus. However, in three ponies the steady concentrations were significantly higher than targeted. It is hypothesized that an inaccurate estimation of the volume of the central compartment is partly responsible for that difference. The algorithm allowed good predictions for the single bolus administration and an appropriate maintenance of constant plasma concentrations.
Resumo:
Patients with left ventricular noncompaction (LVNC) have an increased risk for life-threatening ventricular arrhythmias. The benefit from implantable cardioverter-defibrillators (ICD) in these patients has been investigated only in small series. Therefore, the aim of the present study was to analyze the clinical outcome of a larger population of patients with LVNC who were treated with an ICD.
Resumo:
(11)C-ABP-688 is a selective tracer for the mGluR5 receptor. Its kinetics is fast and thus favourable for an equilibrium approach to determine receptor-related parameters. The purpose of this study was to test the hypothesis that the pattern of the (11)C-ABP688 uptake using a bolus-plus-infusion (B/I) protocol at early time points corresponds to the perfusion and at a later time point to the total distribution volume. METHODS: A bolus and a B/I study (1 h each) was performed in five healthy male volunteers. With the B/I protocol, early and late scans were normalized to gray matter, cerebellum and white matter. The same normalization was done on the maps of the total distribution volume (Vt) and K(1) which were calculated in the study with bolus only injection and the Logan method (Vt) and a two-tissue compartment model (K(1)). RESULTS: There was an excellent correlation close to the identity line between the pattern of the late uptake in the B/I study and Vt of the bolus-only study for all three normalizations. The pattern of the early uptake in the B/I study correlated well with the K(1) maps, but only when normalized to gray matter and cerebellum, not to white matter. CONCLUSION: It is demonstrated that with a B/I protocol the (11)C-ABP688 distribution in late scans reflects the pattern of the total distribution volume and is therefore a measure for the density pattern of mGluR5. The early scans following injection are related to blood flow, although not in a fully quantitative manner. The advantage of the B/I protocol is that no arterial blood sampling is required, which is advantageous in clinical studies.
Resumo:
Different therapeutic approaches have been used in fetal-neonatal alloimmune thrombocytopenia, but many centers administer immunoglobulin G infusions to the pregnant woman. We studied the effect of maternal antenatal immunoglobulin infusions on fetal platelet counts in pregnancies with fetal alloimmune thrombocytopenia.
Resumo:
In this study, the effect of time derivatives of flow rate and rotational speed was investigated on the mathematical modeling of a rotary blood pump (RBP). The basic model estimates the pressure head of the pump as a dependent variable using measured flow and speed as predictive variables. Performance of the model was evaluated by adding time derivative terms for flow and speed. First, to create a realistic working condition, the Levitronix CentriMag RBP was implanted in a sheep. All parameters from the model were physically measured and digitally acquired over a wide range of conditions, including pulsatile speed. Second, a statistical analysis of the different variables (flow, speed, and their time derivatives) based on multiple regression analysis was performed to determine the significant variables for pressure head estimation. Finally, different mathematical models were used to show the effect of time derivative terms on the performance of the models. In order to evaluate how well the estimated pressure head using different models fits the measured pressure head, root mean square error and correlation coefficient were used. The results indicate that inclusion of time derivatives of flow and speed can improve model accuracy, but only minimally.
Resumo:
The effect of the swirl component of air injection on the performance of an airlift pump was examined experimentally. An airlift pump is a device that pumps a liquid or slurry using only gas injection. In this study, the liquid used was water and the injected gas was air. The effect of the air swirl was determined by measuring the water discharge from an airlift pump with an air injection nozzle in which the air flow had both axial and tangential components and then repeating the tests with a nozzle with only axial injection. The induced water flow was measured using an orifice meter in the supply pipeline. Tests were run for air pressures ranging from 10 to 30 pounds per square inch, gauge (psig), at flow rates from 5 standard cubic feet per minute (scfm) up the maximum values attainable at the given pressure (usually in the range from 20 to 35 scfm). The nozzle with only axial injection produced a water flow rate that wasequivalent to or better than that induced by the nozzle with swirl. The swirl component of air injection was found to be detrimental to pump performance for all but the smallest air injection flow rate. Optimum efficiency was found for air injection pressures of 10 psig to 15 psig. In addition, the effect of using auxiliary tangential injection of water to create a swirl component in the riser before air injection on the overall capacity (i.e., flow rate) and efficiencyof the pump was examined. Auxiliary tangential water injection was found to have no beneficial effect on the pump capacity or performance in the present system.
Resumo:
The implantable cardioverter defibrillator (ICD) is the gold standard therapy to prevent life-threatening arrhythmias. Phobic anxiety predicts ventricular arrhythmia in coronary heart disease patients, but little is known about phobic anxiety in ICD patients. This study aimed to identify determinants and the course of phobic anxiety in ICD patients.