989 resultados para Image diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Researchers examined the sun-protective intentions and behavior of young, Caucasian, Australian sportswomen aged between 17 and 35 years (N = 100). The study adopted a 2 x 2 experimental design, comparing group norms (supportive vs. non-supportive) and image norms (tanned vs. pale) related to sun protection and taking into account group identification with friends and peers in the sport. While no significant findings emerged involving image norms, regression analyses revealed a significant two-way interaction for group norm x identification on recreational sportswomen's intentions to engage in sun protection in the next fortnight. Participants identifying strongly with their group had stronger intentions to engage in sun protection when exposed to a norm reflecting fellow recreational sportswomen engaging in sun-protective actions in comparison to those exposed to a non-supportive group. In addition, while prior intentions to engage in sun protection were not significantly related to sun-protection behavior, post-manipulation intentions after exposure to the sun-protective information that was provided were significantly related to follow-up behavior. Overall, the findings supported the importance of group-based social influences, rather than tanned media images, on sun-protective decisions among young recreational sportswomen and provided a targeted source for intervention strategies encouraging sun safety among this at-risk group for repeated sun exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acetylcholine receptor (AchR) antibody assay has a key role in the diagnosis of myasthenia gravis. In this article, the role of AchR antibody assay in the diagnosis of ocular and generalized myasthenia gravis is reviewed, and compared to standard means of diagnosing the disease by clinical and electrophysiological methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship of acetylcholine receptor (AchR) antibodies to disease activity in myasthenia gravis (MG) is controversial. Some authors claim a direct correlation with disease activity and treatment, in particular plasmapheresis therapy, whereas others have commented on the poor overall correlation of antibody levels with clinical state. Antibody levels were examined in a population of MG patients and correlated with disease activity and response to treatment. Antibodies to skeletal muscle AchR were found in most patients with generalised MG (24/25) and in about half of the patients with purely ocular MG (6/10) and in neither of 2 patients with congenital MG. There was scant correlation with disease activity or response to treatment. It is concluded that the assay is more useful for diagnosis than for management of MG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed Wireless Smart Camera (DWSC) network is a special type of Wireless Sensor Network (WSN) that processes captured images in a distributed manner. While image processing on DWSCs sees a great potential for growth, with its applications possessing a vast practical application domain such as security surveillance and health care, it suffers from tremendous constraints. In addition to the limitations of conventional WSNs, image processing on DWSCs requires more computational power, bandwidth and energy that presents significant challenges for large scale deployments. This dissertation has developed a number of algorithms that are highly scalable, portable, energy efficient and performance efficient, with considerations of practical constraints imposed by the hardware and the nature of WSN. More specifically, these algorithms tackle the problems of multi-object tracking and localisation in distributed wireless smart camera net- works and optimal camera configuration determination. Addressing the first problem of multi-object tracking and localisation requires solving a large array of sub-problems. The sub-problems that are discussed in this dissertation are calibration of internal parameters, multi-camera calibration for localisation and object handover for tracking. These topics have been covered extensively in computer vision literatures, however new algorithms must be invented to accommodate the various constraints introduced and required by the DWSC platform. A technique has been developed for the automatic calibration of low-cost cameras which are assumed to be restricted in their freedom of movement to either pan or tilt movements. Camera internal parameters, including focal length, principal point, lens distortion parameter and the angle and axis of rotation, can be recovered from a minimum set of two images of the camera, provided that the axis of rotation between the two images goes through the camera's optical centre and is parallel to either the vertical (panning) or horizontal (tilting) axis of the image. For object localisation, a novel approach has been developed for the calibration of a network of non-overlapping DWSCs in terms of their ground plane homographies, which can then be used for localising objects. In the proposed approach, a robot travels through the camera network while updating its position in a global coordinate frame, which it broadcasts to the cameras. The cameras use this, along with the image plane location of the robot, to compute a mapping from their image planes to the global coordinate frame. This is combined with an occupancy map generated by the robot during the mapping process to localised objects moving within the network. In addition, to deal with the problem of object handover between DWSCs of non-overlapping fields of view, a highly-scalable, distributed protocol has been designed. Cameras that follow the proposed protocol transmit object descriptions to a selected set of neighbours that are determined using a predictive forwarding strategy. The received descriptions are then matched at the subsequent camera on the object's path using a probability maximisation process with locally generated descriptions. The second problem of camera placement emerges naturally when these pervasive devices are put into real use. The locations, orientations, lens types etc. of the cameras must be chosen in a way that the utility of the network is maximised (e.g. maximum coverage) while user requirements are met. To deal with this, a statistical formulation of the problem of determining optimal camera configurations has been introduced and a Trans-Dimensional Simulated Annealing (TDSA) algorithm has been proposed to effectively solve the problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly sensitive infrared cameras can produce high-resolution diagnostic images of the temperature and vascular changes of breasts. Wavelet transform based features are suitable in extracting the texture difference information of these images due to their scale-space decomposition. The objective of this study is to investigate the potential of extracted features in differentiating between breast lesions by comparing the two corresponding pectoral regions of two breast thermograms. The pectoral regions of breastsare important because near 50% of all breast cancer is located in this region. In this study, the pectoral region of the left breast is selected. Then the corresponding pectoral region of the right breast is identified. Texture features based on the first and the second sets of statistics are extracted from wavelet decomposed images of the pectoral regions of two breast thermograms. Principal component analysis is used to reduce dimension and an Adaboost classifier to evaluate classification performance. A number of different wavelet features are compared and it is shown that complex non-separable 2D discrete wavelet transform features perform better than their real separable counterparts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis threat is a psychosocial factor that has been proposed to contribute to poor outcomes following mild traumatic brain injury (mTBI). This threat is thought to impair the cognitive test performance of individuals with mTBI because of negative injury stereotypes. University students (N= 45, 62.2% female) with a history of mTBI were randomly allocated to a diagnosis threat (DT, n=15), reduced threat (DT-reduced, n=15) or neutral (n=15) group. The reduced threat condition invoked a positive stereotype (i.e., that people with mTBI can perform well on cognitive tests). All participants were given neutral instructions before they completed baseline tests of: a) objective cognitive function across a number of domains; b) psychological symptoms; and, c) PCS symptoms, including self-reported cognitive and emotional difficulties. Participants then received either neutral, DT or DT-reduced instructions, before repeating the tests. Results were analyzed using separate mixed model ANOVAs; one for each dependent measure. The only significant result was for the 2 X 3 ANOVA on an objective test of attention/working memory, Digit Span, p<.05, such that the DT-reduced group performed better than the other groups, which were not different from each other. Although not consistent with predictions or earlier DT studies, the absence of group differences on most tests fits with several recent DT findings. The results of this study suggest that it is timely to reconsider the role of DT as a unique contributor to poor mTBI outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background A reliable standardized diagnosis of pneumonia in children has long been difficult to achieve. Clinical and radiological criteria have been developed by the World Health Organization (WHO), however, their generalizability to different populations is uncertain. We evaluated WHO defined chest radiograph (CXRs) confirmed alveolar pneumonia in the clinical context in Central Australian Aboriginal children, a high risk population, hospitalized with acute lower respiratory illness (ALRI). Methods CXRs in children (aged 1-60 months) hospitalized and treated with intravenous antibiotics for ALRI and enrolled in a randomized controlled trial (RCT) of Vitamin A/Zinc supplementation were matched with data collected during a population-based study of WHO-defined primary endpoint pneumonia (WHO-EPC). These CXRs were reread by a pediatric pulmonologist (PP) and classified as pneumonia-PP when alveolar changes were present. Sensitivities, specificities, positive and negative predictive values (PPV, NPV) for clinical presentations were compared between WHO-EPC and pneumonia-PP. Results Of the 147 episodes of hospitalized ALRI, WHO-EPC was significantly less commonly diagnosed in 40 (27.2%) compared to pneumonia-PP (difference 20.4%, 95% CI 9.6-31.2, P < 0.001). Clinical signs on admission were poor predictors for both pneumonia-PP and WHO-EPC; the sensitivities of clinical signs ranged from a high of 45% for tachypnea to 5% for fever + tachypnea + chest-indrawing. The PPV range was 40-20%, respectively. Higher PPVs were observed against the pediatric pulmonologist's diagnosis compared to WHO-EPC. Conclusions WHO-EPC underestimates alveolar consolidation in a clinical context. Its use in clinical practice or in research designed to inform clinical management in this population should be avoided. Pediatr Pulmonol. 2012; 47:386-392. (C) 2011 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Oropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. Methods We plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of ‘CFE + CA’ versus ‘CFE’ only compared to MBS-identified OPA. Discussion Early detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the diagnostic accuracy of the interRAI Acute Care (AC) Cognitive Performance Scale (CPS2) and the Mini-Mental State Examination (MMSE), against independent clinical diagnosis for detecting dementia in older hospitalized patients. Design, Setting, and Participants The study was part of a prospective observational cohort study of patients aged ≥70 years admitted to four acute hospitals in Queensland, Australia, between 2008 and 2010. Recruitment was consecutive and patients expected to remain in hospital for ≥48 hours were eligible to participate. Data for 462 patients were available for this study. Measurements Trained research nurses completed comprehensive geriatric assessments and administered the interRAI AC and MMSE to patients. Two physicians independently reviewed patients’ medical records and assessments to establish the diagnosis of dementia. Indicators of diagnostic accuracy included sensitivity, specificity, predictive values, likelihood ratios and areas under receiver (AUC) operating characteristic curves. Results 85 patients (18.4%) were considered to have dementia according to independent clinical diagnosis. The sensitivity of the CPS2 [0.68 (95%CI: 0.58–0.77)] was not statistically different to the MMSE [0.75 (0.64–0.83)] in predicting physician diagnosed dementia. The AUCs for the 2 instruments were also not statistically different: CPS2 AUC = 0.83 (95%CI: 0.78–0.89) and MMSE AUC = 0.87 (95%CI: 0.83–0.91), while the CPS2 demonstrated higher specificity [0.92 95%CI: 0.89–0.95)] than the MMSE [0.82 (0.77–0.85)]. Agreement between the CPS2 and clinical diagnosis was substantial (87.4%; κ=0.61). Conclusion The CPS2 appears to be a reliable screening tool for assessing cognitive impairment in acutely unwell older hospitalized patients. These findings add to the growing body of evidence supporting the utility of the interRAI AC, within which the CPS2 is embedded. The interRAI AC offers the advantage of being able to accurately screen for both dementia and delirium without the need to use additional assessments, thus increasing assessment efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been significant debate about the value of screening for dementia, and the need for early diagnosis. Options include Gene testing, early risk assessment, screening, case finding and review when a patient or carer identify that they have symptoms. This paper is not focused on these early approaches to identifying people with dementia. It is focused on the period when a patient or a carer has recognised that there are some memory problems and they are seeking assistance with a diagnosis or explanation in relation to memory loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microvessel density (MVD) is a widely used surrogate measure of angiogenesis in pathological specimens and tumour models. Measurement of MVD can be achieved by several methods. Automation of counting methods aims to increase the speed, reliability and reproducibility of these techniques. The image analysis system described here enables MVD measurement to be carried out with minimal expense in any reasonably equipped pathology department or laboratory. It is demonstrated that the system translates easily between tumour types which are suitably stained with minimal calibration. The aim of this paper is to offer this technique to a wider field of researchers in angiogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Superficial bladder cancer (SBC) presents a difficult clinical dilemma at diagnosis as only a small subgroup of patients will subsequently develop invasive disease. Study of cancer biology has found that angiogenesis is central to growth and spread. This study examines the relationship between the angiogenic inhibitory factor Thrombospondin-1 (TSP-1) at initial presentation and subsequent progression of SBC. Methods: Using immunohistochemistry, 220 cases of SBC were examined for pattern and extent of expression of TSP-1 at initial presentation. Results: TSP-1 was detected in perivascular tissue, at the epithelial-stromal junction, in the stroma and in tumour cells and reduced perivascular TSP-1 staining at presentation was an independent predictive factor for the subsequent development of muscle invasive or metastatic disease. Conclusion: This adds further weight to the theory that TSP-1 plays a major part in the biology of bladder cancer possibly through the control of angiogenesis. © 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent advances in the understanding of the pathogenesis of ovarian cancer have been helpful in addressing issues in diagnosis, prognosis and management. The study of ovarian tumours by novel techniques such as immunohistochemistry, fluorescent in situ hybridisation, comparative genomic hybridisation, polymerase chain reaction and new tumour markers have aided the evaluation and application of new concepts into clinical practice. The correlation of novel surrogate tumour specific features with response to treatment and outcome in patients has defined prognostic factors which may allow the future design of tailored therapy based on a molecular profile of the tumour. These have also been used to design new approaches to therapy such as antibody targeting and gene therapy. The delineation of roles of c-erbB2, c-fms and other novel receptor kinases in the pathogenesis of ovarian cancer has led initially to the development of anti-c-erbB2 monoclonal antibody therapy. The discovery of BRCA1 and BRCA2 genes will have an impact in the diagnosis and the prevention of familial ovarian cancer. The important role played by recessive genes such as p53 in cancer has raised the possibility of restoration of gene function by gene therapy. Although the pathological diagnosis of ovarian cancer is still confirmed principally on morphological features, addition of newer investigations will increasingly be useful in addressing difficult diagnostic problems. The increasingly rapid pace of discovery of genes important in disease, makes it imperative that the evaluation of their contribution in the pathogenesis of ovarian cancer is undertaken swiftly, thus improving the overall management of patients and their outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To provide an overview of 1) traditional methods of skin cancer early detection, 2) current technologies for skin cancer detection, and 3) evolving practice models of early detection. DATA SOURCES: Peer-reviewed databased articles and reviews, scholarly texts, and Web-based resources. CONCLUSION: Early detection of skin cancer through established methods or newer technologies is critical for reducing both skin cancer mortality and the overall skin cancer burden. IMPLICATIONS FOR NURSING PRACTICE: A basic knowledge of recommended skin examination guidelines and risk factors for skin cancer, traditional methods to further examine lesions that are suspicious for skin cancer and evolving detection technologies can guide patient education and skin inspection decisions.