991 resultados para INDOOR AIR


Relevância:

60.00% 60.00%

Publicador:

Resumo:

"September 1995"--P. [1].

Relevância:

60.00% 60.00%

Publicador:

Resumo:

"July 2003."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Growing evidence suggest the importance of different environments in promoting the pathogenesis and/or exacerbation of asthma. Indoor air pollution is a major contributor to human exposure, since people spend up to 90% of their day indoors. Apart from active smoking, indoor pollution is considered one of the major preventable risk factors of chronic respiratory diseases. The professional activity can also be dangerous because it exposes the subject to environments that can promote the onset of asthma or worsening of the latter in those already affected. Even bad habits such as incorrect diet, lead to more difficulty in controlling their disease. However asthma is a multifactorial disease in nature so it is not easy to distinguish the role of occupational exposure, pollution and normal habits such as smoking, nutrition, sports, etc. This retrospective study was conducted on a sample of asthma patients residing in the metropolitan area of Parma. 116 patients were selected among those who are followed up at least two years at the Asthma outpatient Clinic of Parma University Hospital. The sample in question is therefore closely controlled and monitored; it comes to patients who are well educated on the control of their disease, are able to take appropriate measures to minimize the symptomatology. With this tight approach is proposed to minimize the effect of confounding and then traced with greater certainty the possible cause of the failure to control the disease. For this purpose, each patient was subjected to regular checkups; we took as a reference the period of time between April and October 2015. During each visit, in addition to general data for each patient, we were collected personal information about their habits and way of life through a validated questionnaire delivered and completed by the patient during the visit in the presence of the permanent staff. The questionnaire covers mainly the qualification of the patient, its possible occupational exposure, his home, with information about nearby traffic, time spent outside, physical activity (place and time), exposure to chemicals, exposure to various fumes (fireplace or stove) and cigarette smoke, comorbidities and any drugs taken during the visits considered. Regarding the respiratory conditions of patients during every examination we were considered: Asthma Control Test (a test performed by patients to assess the state of the disease during the month preceding the test), the measurement of exhaled nitric oxide (FeNO) as an index of airways inflammation, measuring the resistance level of small airways (R5-R20) and some spirometric values observed in experiment; in particular the forced vital capacity (FVC), forced expiratory volume in the first second (FEV 1), FEV1/FVC ratio, forced expiratory flow rate over the middle 50% of the FVC (FEF25–75) and FEF25-75/FVC were recorded. The sample has been studied considering both the changes of the respiratory parameters for every patient in their examinations, and the respiratory parameters of all the examinations took as a whole in relation with the variables considered. From the results obtained, the patients are clinically stable; their adopted lifestyle and the exposure to possible sources of outdoor pollution, seems not affect the overall control of their disease. Some findings of our study are of interest. First, the subjects who carry a steroid therapy show a clinical worst, as revealed by the decrease of most spirometric indices, particularly FEF25, FEF75, FEF25-75 and R5-R20; also, the presence of comorbidities and the subsequent intake of other drugs, in addition to normal therapy for asthma, seem to be conditions associated with poorer performance in the functional respiratory parameters in particular FEV1/FVC, FEF75 and FEF25-75. Spirometric indexes that are down are mainly those related to obstruction imposed on small airways; this suggests a neglect to the latter on the contrary should be further explored and treated accordingly. It is also observed that both patients are overweight than those living on the lower floors and/or who have the most windows exposed to traffic, showed a decrease of pulmonary function, especially those relate to an obstruction at the small airways level. In conclusion, our results provided the evidence that a most appropriate therapy, specific to reach the small airways, associated with a healthy lifestyle, can help improve the management of asthma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: In the Mediterranean areas of Europe, leishmanisasis is one of the most emerging vector-borne diseases. Members of genus Phlebotomus are the primary vectors of the genus Leishmania. To track the human health effect of climate change it is a very important interdisciplinary question to study whether the climatic requirements and geographical distribution of the vectors of human pathogen organisms correlate with each other. Our study intended to explore the potential effects of ongoing climate change, in particular through a potential upward altitudinal and latitudinal shift of the distribution of the parasite Leishmania infantum, its vectors Phlebotomus ariasi, P. neglectus, P. perfiliewi, P. perniciosus, and P. tobbi, and some other sandfly species: P. papatasi, P. sergenti, and P. similis. Methods: By using a climate envelope modelling (CEM) method we modelled the current and future (2011-2070) potential distribution of 8 European sandfly species and L. infantum based on the current distribution using the REMO regional climate model. Results: We found that by the end of the 2060’s most parts of Western Europe can be colonized by sandfly species, mostly by P. ariasi and P. pernicosus. P. ariasi showed the greatest potential northward expansion. For all the studied vectors of L. infantum the entire Mediterranean Basin and South-Eastern Europe seemed to be suitable. L. infantum can affect the Eastern Mediterranean, without notable northward expansion. Our model resulted 1 to 2 months prolongation of the potentially active period of P. neglectus P. papatasi and P. perniciosus for the 2060’s in Southern Hungary. Conclusion: Our findings confirm the concerns that leishmanisais can become a real hazard for the major part of the European population to the end of the 21th century and the Carpathian Basin is a particularly vulnerable area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As the population of urban poor living in slums increases, governments are trying to relocate people into government-provided free housing. Slum redevelopment affects every part of a household’s livelihood, but most importantly the health and wellbeing of younger generations. This paper investigates the effect of slum redevelopment schemes on child stunting levels. Data was collected in forty-one buildings under the slum-redevelopment program in Mumbai. The study demonstrates through a fixed effect regression analysis that an additional year of living in the building is associated with an increase in the height-for-age Z-score by 0.124 standard deviations. Possible explanations include an improvement in the overall hygienic environment, sanitation conditions, indoor air pollution, and access to health and water facilities. However, anecdotal evidence suggests that water contamination, loss of livelihood and increased expenses could worsen health outcomes for residents. This study prompts more research on the health effects of slum redevelopment projects, which are becoming increasingly common in the rapidly urbanizing developing world.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A consciencialização ambiental vem assumindo um papel preponderante na construção civil. Nesse sentido, o desenvolvimento de materiais sustentáveis e ecológicos é essencial para a satisfação de fabricantes e consumidores, respeitando diversos requisitos: níveis reduzidos de poluição e toxicidade, durabilidade dos materiais, possibilidade de reutilização e/ou reciclagem, a proveniência das matérias-primas e a possibilidade de contaminação do ar no interior dos edifícios. As declarações ambientais de produto (DAP) permitem informar o consumidor do desempenho ambiental dos materiais dos produtos. Assim, ao longo de todo o processo de fabrico são registados os consumos de recursos e emissões ambientais e, através da metodologia de avaliação de ciclo de vida, é quantificada a contribuição resultante para impactes ambientais. Esta dissertação visa analisar os possíveis impactes ambientais no decurso do processo de produção de um pavimento flutuante de cortiça, constituído por cortiça, High Density Fibreboard (HDF) e acabamento de superfície, denominado Artcomfort Floating NPC e elaborar de um relatório de suporte, que servirá de base para a DAP do pavimento Artcomfort Floating NPC do sistema do Institut Bauen und Umwelt (IBU). Esta dissertação inclui um relatório de fundo, para a avaliação do ciclo de vida do pavimento flutuante Artcomfort Floating NPC da empresa Amorim Revestimentos, que servirá de base para a elaboração da declaração ambiental de produto (DAP) do mesmo. Para tal, recorreu-se ao software SimaPro para análise dos impactes ambientais das várias fases do processo de fabrico do pavimento em estudo, sendo as fases consideradas, a produção da camada base de cortiça aglomerada, camada backing de cortiça aglomerada, montagem da sanduiche, placa pintada, placa acabada e corte e embalagem. A fase que tem maior contribuição para os impactes ambientais do processo de fabrico do produto, em todas as categorias de impacte analisadas, com exceção da depleção dos recursos abióticos sem combustíveis fósseis, foi a fase de montagem da sanduiche.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Em arquivos e bibliotecas a presença de fungos é considerada nefasta pelas suas implicações na conservação e leitura de documentos históricos e pela sua associação a problemas de saúde sentidos pelos funcionários e utentes que frequentam estes locais. De acordo com alguns autores, os problemas de saúde mais reportados por funcionários em Bibliotecas e Arquivos são dermatite, rinite, alergias e asma. Embora revestida de inegável importância, existem poucos estudos internacionais sobre a temática e, em Portugal, a contaminação fúngica em ambiente arquivístico e em bibliotecas é ainda muito pouco conhecida. O estudo realizado em quatro Arquivos Portugueses teve como objectivo conhecer a contaminação fúngica, contribuindo para a análise da qualidade do ar interior desses espaços e sua comparação com estudos internacionais. Para isso foram recolhidas amostras de ar e de superfícies e estas foram analisadas por métodos clássicos de cultura e, quando necessário, por métodos de biologia molecular. A avaliação foi feita quantitativa e qualitativamente, considerando os requisitos legais em vigor. No que respeita à análise do ar, o número de unidades formadoras de colónias (UFC)/m3 nunca excedeu as 500 (limite legislado), tendo sido verificada contaminação interior em todos os locais estudados. Comparativamente aos estudos realizados anteriormente em contextos semelhantes foram encontrados níveis elevados de contaminação por leveduras nas amostras de ar analisadas em Arquivos Portugueses. Não foi identificado nenhum fungo patogénico neste estudo, mas em quase todas as amostras estavam presentes fungos potencialmente toxinogénicos. Dentro do grupo dos Aspergillus, o A.versicolor mostrou predominância, tendo este fungo reconhecidas capacidades de emissão de micotoxinas em ambiente de interior. A inclusão de amostras de superfície revelou-se vital para conhecer todo o espectro fúngico existente em cada um dos locais estudados, incluindo a detecção de Stachybotrys chartarum e a do fungo potencialmente queratinofílico, Chrysosporium carmichaelli. Tanto para a saúde como para a conservação, o recente estudo realizado em quatro arquivos permitiu retirar importantes conclusões e reforçar a necessidade de vigilância, sendo também útil para a definição de padrões de qualidade no campo do património cultural.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Personal exposure and possible cancer risk to formaldehyde and acetaldehyde were appraised in 8 work places at a university in Brazil. Levels of formaldehyde measured ranged from 22.5 to 161.5 g·m 3 and from 18.3 to 91.2 g·m 3 for acetaldehyde. The personal exposure, expressed as the potential dose in indoor air, was calculated to range from 129.8 to 930.4 g·day 1 (low exposure) and 183.9 to 1318.1 g·day 1 (medium exposure) for formaldehyde and 105.5 to 525.3 g·day 1 (low exposure) and 149.5 to 744.2 g·day 1 (medium exposure) for acetaldehyde. The indoor/outdoor ratio showed the existence of indoor sources of the compounds which were mainly in practical classes and research laboratories. The highest formaldehyde and acetaldehyde levels were found where chemical reagents were manipulated. Relating the levels found to the permissible limit given by the US OSHA showed there was no particular risk although some formaldehyde levels did exceed the lower exposure limit of the US agency NIOSH. Any cancer risk would be highest for female technicians and teaching researchers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Kandidaatintyön tarkoituksena oli perehtyä Tekesin Terve talo -konseptiin ja tutustua sisäilmaongelmiin. Työn tavoitteina oli kartoittaa sisäilmaongelmien lähteitä ja tutustua Terve talo -rakentamiseen ja tunnistaa ongelmakohtia, jotka johtavat usein kosteus- ja homeongelmiin sekä sisäilmaongelmiin. Näitä haasteita ja ongelmakohtia vertailtiin Terve talo -kriteereihin ja pohdittiin, miten rakentamisen laatua ja ylläpitoa voidaan parantaa, että tulevaisuudessa vältyttäisiin sisäilmaongelmilta. Työ oli kirjallisuustyö, joka perustui kirjallisiin lähteisiin. Työssä käsiteltiin vain uudisrakentamista toimitilarakentamisen Terve talo -kriteereiden avulla. Terve talo -rakentaminen on laadukkaampaa kuin määräykset sanovat. Konseptin mukaan rakennettaessa rakennetaan kosteusteknisesti toimivaa ja terveellistä rakennusta, jossa on hyvä sisäilma. Terve talo -rakennus rakennetaan Terve talo -kriteerien avulla, joita seurataan koko rakennushankkeen ajan. Sisäilmaongelmia aiheuttavat monet eri asiat, kuten hiukkasmaiset ja kaasumaiset epäpuhtaudet. Suuria ongelmia aiheuttavat myös kosteus- ja homeongelmista johtuvat kosteusvauriomikrobit. Epäpuhtaudet aiheuttavat ihmisille terveydellisiä haittoja, kuten silmien ja hengitysteiden ärsyyntymistä. Kosteus- ja homeongelmat voivat johtua monesta syystä. Ongelmia voi aiheuttaa mm. riittämätön suunnittelu, riittämätön kosteudenhallinta työmaalla tai käytön aikaiset virheet. Työn tuloksena voidaan todeta, että kriteereiden avulla voidaan vähentää ja mahdollisesti kokonaan välttyä sisäilmaongelmilta. Rakentaminen vaatii kuitenkin monen asian huomiointia optimointia. Rakennuksen ylläpidon ja huollon tulee myös olla laadukasta ja ennakoivaa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A qualidade do ar interior (QAI) em edifícios é uma preocupação que acompanha o Homem desde há séculos. A qualidade do ar interior nas escolas, em particular, tem vindo a provocar um crescente interesse, dado que o grupo populacional pertence a um grupo etário mais suscetível de ser afetado. A utilização de ferramentas numéricas de modelação na avaliação da QAI é uma mais valia, pois permite estimar as concentrações dos poluentes no interior dos edifícios. O principal objetivo deste estudo consiste na avaliação da qualidade do ar interior através da aplicação de uma ferramenta a um caso de estudo. Neste caso de estudo estimou-se a concentração de material particulado (PM10) numa sala de aula da Escola Básica nº 1 da Glória, em Aveiro. Neste âmbito, foi aplicado o modelo INDEX, Indoor Exposure model, que possibilita o cálculo de concentrações interiores de poluentes atmosféricos. Os resultados da aplicação indicam que as concentrações do ar interior são influenciadas pelas concentrações exteriores e pela velocidade do vento. Note-se, contudo, que os valores simulados cumprem os valores legislados na Portaria nº 353-A/2013, de 4 de Dezembro. Embora os resultados simulados não revelem uma má qualidade do ar interior na sala de aula da Escola Básica nº 1 da Glória, a avaliação de outros poluentes seria um ponto de extrema importância, de forma a verificar se os requisitos da qualidade do ar interior estarão a ser garantidos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is increasing evidence of a causal link between airborne particles and ill health and this study monitored the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a nightclub. The present study followed a number of pilot studies in which the human exposure to airborne particles in a nightclub was assessed and the spatio-temporal distribution of gas phase pollutants was evaluated in restaurants and pubs. The work reported here re-examined the nightclub environment and utilized concurrent and continuous monitoring using optical scattering samplers to measure particulates (PM10) together with multi-gas analysers. The analysis illustrated the highly episodic nature of both gaseous and particulate concentrations in both the dance floor and in the bar area but levels were well below the maximum recommended exposure levels. Short-term exposure to high concentrations may however be relevant when considering the possible toxic effects on biological systems. The results give an indication of the problems associated with achieving acceptable indoor air quality (IAQ) in a complex space and identified some of the problems inherent in the design and operation of ventilation systems for such spaces.