945 resultados para Hospital Cardiac-arrest


Relevância:

80.00% 80.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: After years of advocating ABC (Airway-Breathing-Circulation), current guidelines of cardiopulmonary resuscitation (CPR) recommend CAB (Circulation-Airway-Breathing). This trial compared ABC with CAB as initial approach to CPR from the arrival of rescuers until the completion of the first resuscitation cycle. METHODS: 108 teams, consisting of two physicians each, were randomized to receive a graphical display of either the ABC algorithm or the CAB algorithm. Subsequently teams had to treat a simulated cardiac arrest. Data analysis was performed using video recordings obtained during simulations. The primary endpoint was the time to completion of the first resuscitation cycle of 30 compressions and two ventilations. RESULTS: The time to execution of the first resuscitation measure was 32 ± 12 seconds in ABC teams and 25 ± 10 seconds in CAB teams (P = 0.002). 18/53 ABC teams (34%) and none of the 55 CAB teams (P = 0.006) applied more than the recommended two initial rescue breaths which caused a longer duration of the first cycle of 30 compressions and two ventilations in ABC teams (31 ± 13 vs.23 ± 6 sec; P = 0.001). Overall, the time to completion of the first resuscitation cycle was longer in ABC teams (63 ± 17 vs. 48 ± 10 sec; P <0.0001).CONCLUSIONS: This randomized controlled trial found CAB superior to ABC with an earlier start of CPR and a shorter time to completion of the first 30:2 resuscitation cycle. These findings endorse the change from ABC to CAB in international resuscitation guidelines.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To determine whether standard or increased doses of atropine improve the return of spontaneous circulation (ROSC) rate in a canine model of pulseless electrical activity (PEA). METHODS A prospective, controlled, blinded laboratory investigation was performed using an asphyxial canine cardiac arrest model. After the production of asphyxial PEA, 75 dogs remained in untreated PEA for 10 minutes and then were randomized to receive placebo (group 1) or one of four doses of atropine (group 2, 0.04 mg/kg; group 3, 0.1 mg/kg; group 4, 0.2 mg/kg; group 5, 0.4 mg/kg). All the animals received mechanical external CPR and epinephrine (0.02 mg/kg every 3 minutes) throughout resuscitation. RESULTS The ROSC rates were not significantly different between the groups (group 1, 73%; group 2, 67%; group 3, 40%; group 4, 47%; group 5, 27%; p = 0.06). The heart rates and hemodynamics during resuscitation were not significantly different between the groups. CONCLUSION In this canine model of asphyxial PEA cardiac arrest, standard-dose atropine did not improve ROSC rates, compared with placebo. Increasing doses of atropine tended to decrease ROSC rates, compared with placebo and standard-dose atropine.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To study the hemodynamic effects of exogenously administered endothelin-1 (ET-1), a peptide produced by endothelial cells with potent non-adrenergically mediated vasoconstrictor properties. METHODS A prospective drug intervention study was carried out in a resuscitation research laboratory. Fifteen mixed-breed dogs were anesthetized and instrumented for hemodynamic monitoring. Asphyxia arrest was produced by clamping the endotracheal tube. Hemodynamic data were collected continuously. Following loss of aortic fluctuations monitored by thoracic aortic catheter, the animals remained in pulseless electrical activity (PEA) for 10 minutes. After 10 minutes of no-flow PEA, closed-chest CPR was begun and the animals were randomized to one of three treatment groups (EPI, 0.02 mg/kg epinephrine IV every 3 minutes; ENDO, 100 micrograms ET-1 IV at 0 minutes; and EPI/ENDO, a combination of the EPI and ENDO treatments). RESULTS ENDO and EPI alone produced similar coronary perfusion pressures (CPPs). The EPI/ENDO combination produced significantly improved CPP compared with that of either EPI or ENDO alone. In the EPI group, the best mean CPP was 16 +/- 14 mm Hg and occurred 7 minutes after drug administration. In the ENDO group, the best mean CPP was 28 +/- 7 mm Hg and occurred 13 minutes after drug administration. In the EPI/ENDO combination group, the best mean CPP was 61 +/- 37 mm Hg and occurred 7 minutes after drug administration (p < 0.05 compared with the EPI and ENDO groups alone). CONCLUSION ET-1 is a potent vasoconstrictor. The combination of EPI and ENDO significantly improved CPP compared with that for either agent alone. ET-1 should be investigated further as a vasoconstrictor in cardiac arrest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM To evaluate the prognostic value of electrophysiological stimulation (EPS) in the risk stratification for tachyarrhythmic events and sudden cardiac death (SCD). METHODS We conducted a prospective cohort study and analyzed the long-term follow-up of 265 consecutive patients who underwent programmed ventricular stimulation at the Luzerner Kantonsspital (Lucerne, Switzerland) between October 2003 and April 2012. Patients underwent EPS for SCD risk evaluation because of structural or functional heart disease and/or electrical conduction abnormality and/or after syncope/cardiac arrest. EPS was considered abnormal, if a sustained ventricular tachycardia (VT) was inducible. The primary endpoint of the study was SCD or, in implanted patients, adequate ICD-activation. RESULTS During EPS, sustained VT was induced in 125 patients (47.2%) and non-sustained VT in 60 patients (22.6%); in 80 patients (30.2%) no arrhythmia could be induced. In our cohort, 153 patients (57.7%) underwent ICD implantation after the EPS. During follow-up (mean duration 4.8 ± 2.3 years), a primary endpoint event occurred in 49 patients (18.5%). The area under the receiver operating characteristic curve (AUROC) was 0.593 (95%CI: 0.515-0.670) for a left ventricular ejection fraction (LVEF) < 35% and 0.636 (95%CI: 0.563-0.709) for inducible sustained VT during EPS. The AUROC of EPS was higher in the subgroup of patients with LVEF ≥ 35% (0.681, 95%CI: 0.578-0.785). Cox regression analysis showed that both, sustained VT during EPS (HR: 2.26, 95%CI: 1.22-4.19, P = 0.009) and LVEF < 35% (HR: 2.00, 95%CI: 1.13-3.54, P = 0.018) were independent predictors of primary endpoint events. CONCLUSION EPS provides a benefit in risk stratification for future tachyarrhythmic events and SCD and should especially be considered in patients with LVEF ≥ 35%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Current guidelines limit the use of high oxygen tension after return of spontaneous circulation after cardiac arrest, focusing on neurological outcome and mortality. Little is known about the impact of hyperoxia on the ischemic heart. Oxygen is frequently administered and is generally expected to be beneficial. This study seeks to assess the effects of hyperoxia on myocardia oxygenation in the presence of severe coronary artery stenosis in swine. METHODS AND RESULTS In 22 healthy pigs, we surgically attached a magnetic resonance compatible flow probe to the left anterior descending coronary artery (LAD). In 11 pigs, a hydraulic occluder was inflated distal to the flow probe. After increasing PaO2 to >300 mm Hg, LAD flow decreased in all animals. In 8 stenosed animals with a mean fractional flow reserve of 0.64±0.02, hyperoxia resulted in a significant decrease of myocardial signal intensity in oxygenation-sensitive cardiovascular magnetic resonance images of the midapical segments of the LAD territory. This was not seen in remote myocardium or in the other 8 healthy animals. The decreased signal intensity was accompanied by a decrease in circumferential strain in the same segments. Furthermore, ejection fraction, cardiac output, and oxygen extraction ratio declined in these animals. Changing PaCO2 levels did not have a significant effect on any of the parameters; however, hypercapnia seemed to nonsignificantly attenuate the hyperoxia-induced changes. CONCLUSIONS Ventilation-induced hyperoxia may decrease myocardial oxygenation and lead to ischemia in myocardium subject to severe coronary artery stenosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

beta-Oxidation of long-chain fatty acids provides the major source of energy in the heart. Defects in enzymes of the beta-oxidation pathway cause sudden, unexplained death in childhood, acute hepatic encephalopathy or liver failure, skeletal myopathy, and cardiomyopathy. Very-long-chain acyl-CoA dehydrogenase [VLCAD; very-long-chain-acyl-CoA:(acceptor) 2,3-oxidoreductase, EC 1.3.99.13] catalyzes the first step in beta-oxidation. We have isolated the human VLCAD cDNA and gene and determined the complete nucleotide sequences. Polymerase chain reaction amplification of VLCAD mRNA and genomic exons defined the molecular defects in two patients with VLCAD deficiency who presented with unexplained cardiac arrest and cardiomyopathy. In one, a homozygous mutation in the consensus dinucleotide of the donor splice site (g+1-->a) was associated with universal skipping of the prior exon (exon 11). The second patient was a compound heterozygote, with a missense mutation, C1837-->T, changing the arginine at residue 613 to tryptophan on one allele and a single base deletion at the intron-exon 6 boundary as the second mutation. This initial delineation of human mutations in VLCAD suggests that VLCAD deficiency reduces myocardial fatty acid beta-oxidation and energy production and is associated with cardiomyopathy and sudden death in childhood.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Resuscitation guidelines encourage the use of cardiopulmonary resuscitation (CPR) feedback devices implying better outcomes after sudden cardiac arrest. Whether effective continuous feedback could also be given verbally by a second rescuer ("human feedback") has not been investigated yet. We, therefore, compared the effect of human feedback to a CPR feedback device. METHODS In an open, prospective, randomised, controlled trial, we compared CPR performance of three groups of medical students in a two-rescuer scenario. Group "sCPR" was taught standard BLS without continuous feedback, serving as control. Group "mfCPR" was taught BLS with mechanical audio-visual feedback (HeartStart MRx with Q-CPR-Technology™). Group "hfCPR" was taught standard BLS with human feedback. Afterwards, 326 medical students performed two-rescuer BLS on a manikin for 8 min. CPR quality parameters, such as "effective compression ratio" (ECR: compressions with correct hand position, depth and complete decompression multiplied by flow-time fraction), and other compression, ventilation and time-related parameters were assessed for all groups. RESULTS ECR was comparable between the hfCPR and the mfCPR group (0.33 vs. 0.35, p = 0.435). The hfCPR group needed less time until starting chest compressions (2 vs. 8 s, p < 0.001) and showed fewer incorrect decompressions (26 vs. 33 %, p = 0.044). On the other hand, absolute hands-off time was higher in the hfCPR group (67 vs. 60 s, p = 0.021). CONCLUSIONS The quality of CPR with human feedback or by using a mechanical audio-visual feedback device was similar. Further studies should investigate whether extended human feedback training could further increase CPR quality at comparable costs for training.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rates of survival of victims of sudden cardiac arrest (SCA) using cardio pulmonary resuscitation (CPR) have shown little improvement over the past three decades. Since registered nurses (RNs) comprise the largest group of healthcare providers in U.S. hospitals, it is essential that they are competent in performing the four primary measures (compression, ventilation, medication administration, and defibrillation) of CPR in order to improve survival rates of SCA patients. The purpose of this experimental study was to test a color-coded SMOCK system on: 1) time to implement emergency patient care measures 2) technical skills performance 3) number of medical errors, and 4) team performance during simulated CPR exercises. The study sample was 260 RNs (M 40 years, SD=11.6) with work experience as an RN (M 7.25 years, SD=9.42).Nurses were allocated to a control or intervention arm consisting of 20 groups of 5-8 RNs per arm for a total of 130 RNs in each arm. Nurses in each study arm were given clinical scenarios requiring emergency CPR. Nurses in the intervention group wore different color labeled aprons (smocks) indicating their role assignment (medications, ventilation, compression, defibrillation, etc) on the code team during CPR. Findings indicated that the intervention using color-labeled smocks for pre-assigned roles had a significant effect on the time nurses started compressions (t=3.03, p=0.005), ventilations (t=2.86, p=0.004) and defibrillations (t=2.00, p=.05) when compared to the controls using the standard of care. In performing technical skills, nurses in the intervention groups performed compressions and ventilations significantly better than those in the control groups. The control groups made significantly (t=-2.61, p=0.013) more total errors (7.55 SD 1.54) than the intervention group (5.60, SD 1.90). There were no significant differences in team performance measures between the groups. Study findings indicate use of colored labeled smocks during CPR emergencies resulted in: shorter times to start emergency CPR; reduced errors; more technical skills completed successfully; and no differences in team performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Hemorrhagic complications in oral anticoagulant therapy are frequent. Spontaneous sublingual hematomas secondary to anticoagulants are an extremely unusual complication that is potentially lethal. The study reports a case of a patient on anticoagulation therapy with warfarine who develops a massive, spontaneous sublingual hematoma with obstruction of the high airway and cardiac arrest, where emergency transtracheal catheter ventilation was used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

W artykule przedstawiono problematykę śmierci osobniczej (mózgowej) jako przesłanki dopuszczalności przeszczepu ex mortuo. W pierwszej kolejności zostały opisane podstawowe zagadnienia dotyczące pojęcia transplantacji oraz jej rodzajów występujących w piśmiennictwie medycznym. Dalej poruszono tematykę śmierci i jej rodzajów w kontekście transplantacji, podkreślono również występującą w doktrynie różnicę utożsamiania śmierci klinicznej ze śmiercią pozorną, a także przedstawiono występujący w literaturze sztuczny podział śmierci ze względu na narządy, tj. mózg, płuca i serce. Głównym punktem pracy jest zagadnienie śmierci mózgowej (osobniczej). Wskazano wątpliwości natury prawnej, medycznej i społecznej odnośnie do tej przesłanki. Wskazano na metodykę pracy przy ustaleniu śmierci mózgowej. Zwrócono uwagę na fakt zmiany definicji na gruncie obowiązującej ustawy transplantacyjnej. W dalszej kolejności zostało poruszone zagadnienie śmierci wskutek nieodwracalnego zatrzymania krążenia. W podsumowaniu zebrano w sposób ścisły wątki omawiane przez całą pracę i wspominano o innych przesłankach dopuszczalności przeszczepu ex mortuo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rates of survival of victims of sudden cardiac arrest (SCA) using cardio pulmonary resuscitation (CPR) have shown little improvement over the past three decades. Since registered nurses (RNs) comprise the largest group of healthcare providers in U.S. hospitals, it is essential that they are competent in performing the four primary measures (compression, ventilation, medication administration, and defibrillation) of CPR in order to improve survival rates of SCA patients. The purpose of this experimental study was to test a color-coded SMOCK system on:1) time to implement emergency patient care measures 2) technical skills performance 3) number of medical errors, and 4) team performance during simulated CPR exercises. The study sample was 260 RNs (M 40 years, SD=11.6) with work experience as an RN (M 7.25 years, SD=9.42).Nurses were allocated to a control or intervention arm consisting of 20 groups of 5-8 RNs per arm for a total of 130 RNs in each arm. Nurses in each study arm were given clinical scenarios requiring emergency CPR. Nurses in the intervention group wore different color labeled aprons (smocks) indicating their role assignment (medications, ventilation, compression, defibrillation, etc) on the code team during CPR. Findings indicated that the intervention using color-labeled smocks for pre-assigned roles had a significant effect on the time nurses started compressions (t=3.03, p=0.005), ventilations (t=2.86, p=0.004) and defibrillations (t=2.00, p=.05) when compared to the controls using the standard of care. In performing technical skills, nurses in the intervention groups performed compressions and ventilations significantly better than those in the control groups. The control groups made significantly (t=-2.61, p=0.013) more total errors (7.55 SD 1.54) than the intervention group (5.60, SD 1.90). There were no significant differences in team performance measures between the groups. Study findings indicate use of colored labeled smocks during CPR emergencies resulted in: shorter times to start emergency CPR; reduced errors; more technical skills completed successfully; and no differences in team performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduktion: Årligen drabbas cirka 15 000 personer av hjärtstopp i Sverige. Sjuksköterskanhar ett stort i ansvar i omvårdnaden vid hjärtstopp. Sjuksköterskeutbildningen strävar efter attförbereda studenterna inför omvårdnad vid hjärtstopp. Syfte: Att belysasjuksköterskestudenters upplevelse av förberedelse inför att utöva omvårdnad av patienter samband med hjärtstopp. Metod: Kvalitativ design med semistrukturerade intervjuer. Undersökningsgruppen bestämdes av bekvämlighetsurval. 16 sjuksköterskestudenter i termin 6 intervjuades och data analyserades med hjälp av innehållsanalys. Resultat: Resultatet avstudien visade på att informanterna kände en otrygghet i sig själva, och var osäkra inför attutföra hjärt- och lungräddning för första gången på grund av bristande erfarenhet samt för litekunskap. Informanterna upplevde dock trygghet när de hade erfarna kollegor runt omkring sigsamt när de hade upplevt en riktig hjärtstoppssituation själva. Slutsats: Utifrån studiens resultatbedöms att sjuksköterskestudenter inte känner sig trygga i sig själva och i sin förmåga att utföraadekvat S-HLR, samt inte upplever sig vara förberedda inför att hantera en hjärtstoppssituation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the present investigation was to evaluate the influence of the physical fitness of a cardiopulmonary resuscitation (CPR) provider on the performance of and physiologic response to CPR. To this end, comparisons were made of sedentary and physically active subjects in terms of CPR performance and physiologic variables. Two study groups were established: group P (n = 14), composed of sedentary, professional CPR rescuers (mean [± SD]; age, 34 ± 6 years; V̇O2max, 32.5 ± 5.5 mL/kg/min), and group Ex (n = 14), composed of physically active, nonexperienced subjects (age, 34 ± 6 years; V̇O2max, 44.5 ± 8.5 mL/kg/min). Each subject was required to perform an 18-min CPR session, which involved manual external cardiac compressions (ECCs) on an electronic teaching mannequin following accepted standard CPR guidelines. Subjects' gas exchange parameters and heart rates (HRs) were monitored throughout the trial. Variables indicating the adequacy of the ECCs (ECC depth and the percentage of incorrect compressions and hand placements) also were determined. Overall CPR performance was similar in both groups. The indicators of ECC adequacy fell within accepted limits (ie, an ECC depth between 38 and 51 mm). However, fatigue prevented four subjects from group P from completing the trial. In contrast, the physiologic responses to CPR differed between groups. The indicators of the intensity of effort during the trial, such as HR or percentage of maximum oxygen uptake (V̇O2max) were higher in group P subjects than group Ex subjects, respectively (HRs at the end of the trial, 139 ± 22 vs 115 ± 17 beats/min, p < 0.01; percentage of V̇O2max after 12 min of CPR, 46.7 ± 9.7% vs 37.2 ± 10.4%, p < 0,05). These results suggest that a certain level of physical fitness may be beneficial to CPR providers to ensure the adequacy of chest compressions performed during relatively long periods of cardiac arrest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Victims of cardiac arrest need immediate Basic Life Support, in order to preserve as much as possible, the flow of blood to the brain and heart and other vital organs, it is essential to gain time pending differentiated help, performing simple acts and practical (BLS) to save lives. Learn how to perform RPC is an interactive process that requires knowledge and skills, but at the same time an act of solidarity, social responsibility, civic consciousness, and a duty of citizenship. Because no one revives alone, it requires a coordinated work of a team, all citizens must join forces in a single goal: Save Lives, the massification of the BLS (RPC, 2014). We conducted an exploratory study that aimed to identify the social representations of basic life support in the general population. We used the technique of free association of words through a short questionnaire, we obtained a sample of 45 participants. The results show that participants were mostly female and 27 that fashion of age was in the age group 40 to 59 years. With regard to social representations, we find an organized structure follows the core: help, help to revive, and save is giving life, are in fact structural and consensual elements in basic life support. In more peripheral elements we find extremely important elements, which can be worked in a way so that the core is more efficient such as to act coordinately as a team in face of an accident, it can thus be successful in practice. The social representation of basic life support does not differ from that referred in the literature on the subject, but it is common knowledge that these skills can only be acquired if they are systematically trained, because they obey an algorithm that if it is not settled theoretical and instrumentally it is not effective in practice.