844 resultados para Hip Fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

info:eu-repo/semantics/published

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics has been employed to model the fracture of a twodimensional triangular atomic lattice. The N-body Sutton-Chen potential developed for fcc metals and its extended version (Rafii-Tabar and Sutton) for fcc random binary alloys were used for the interatomic interactions. It is shown that at low temperatures cleavage fractures can occur in both an elemental metal and an alloy. At elevated temperatures the nucleation of dislocations is shown to cause a brittle-to-ductile transition. For the brittle crack propagation in the elemental metal, crack propagation speeds have been computed for different stress rates, and a crack instability found to exist as the speed reaches a critical value of about 32% of the Rayleigh wave speed. For the random alloy, we find that the dislocation movement can be affected by the distorted lattice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics has been employed to model the fracture of a two dimensional triangular atomic lattice. The N-body Sutton-Chen potential developed for fcc metals and its extended version (Rafii-Tabar and Sutton) for fcc random binary alloys were used for the interatomic interactions. It is shown that at low temperatures cleavage fractures can occur in both an elemental metal and an alloy. At elevated temperatures the nucleation of dislocations is shown to cause a brittle-to-ductile transition. For the brittle crack propagation in the elemental metal, crack propagation speeds have been computed for different stress rates, and a crack instability found to exist as the speed reaches a critical value of about 32% of the Rayleigh wave speed. For the random alloy, we find that the dislocation movement can be affected by the distorted lattice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial infection primarily with Staphylococcus spp. and Propionibacterium acnes remains a significant complication following total hip replacement. In this in vitro study, we investigated the efficacy of gentamicin loading of bone cement and pre- and postoperative administration of cefuroxime in the prevention of biofilm formation by clinical isolates. High and low initial inocula, representative of the number of bacteria that may be present at the operative site as a result of overt infection and skin contamination, respectively, were used. When a high initial inoculum was used, gentamicin loading of the cement did not prevent biofilm formation by the 10 Staphylococcus spp. and the 10 P. acnes isolates tested. Similarly, the use of cefuroxime in the fluid phase with gentamicin-loaded cement did not prevent biofilm formation by four Staphylococcus spp. and four P. acnes isolates tested. However, when a low bacterial inoculum was used, a combination of both gentamicin-loaded cement and cefuroxime prevented biofilm formation by these eight isolates. Our results indicate that this antibiotic combination may protect against infection after intra-operative challenge with bacteria present in low numbers as a result of contamination from the skin but would not protect against bacteria present in high numbers as a result of overt infection of an existing implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the factors influencing the acceptability of hip protectors to residents of nursing and residential homes, especially the effect of hip protector type, and resident characteristics. Design: A randomised controlled trial with 12 weeks follow-up. Participants were randomised to receive either Safehips or HipSaverTM hip protectors. Setting/Participants: 109 residents aged 61 to 98 years from seven residential homes and two nursing homes in Northern Ireland. Main outcome measures: Percentage day-time use of the hip protectors over 12 weeks and ongoing use at 12 weeks. Results: 42% (119/285) of residents invited to enter the studyagreed to take part, and 109 started to wear the hip protectors. 43.1% (47/109) were still using them at 12 weeks. Mean percentage day-time use for all residents during 12 weeks was 48.6%. There was no significant difference in percentage day-time use (p=0.40), or use at 12 weeks (p=0.56) between the residents wearing Safehips and HipSaverTM protectors. Greater percentage daytime use of hip protectors was associated with being resident in a home for the elderlymentallyinfirm (75.1%, pp0.0005), having a low (12 or less) Barthel score (61.1%, pp0.0005), and having been injured in a fall in the last 12 months (57.3%, p=0.012). Conclusions: The type of hip protector appeared to make no difference to their continued use by residents. Residents with a historyof a fall and those who are physicallyand mentallyincapacitated appear to be more likelyto wear hip protectors. These residents, who are at high risk of falling, are also highlydependent on nursing staff. Efforts to increase hip protector use in residential and nursing home should focus on staff, who are in the best position to advise and influence residents and their relatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hip protectors are protective pads designed to cover the greater trochanter and attenuate or disperse the force of a fall sufficiently to prevent a hip fracture. Promising results from randomised controlled trials in nursing homes have resulted in hip protectors being widely recommended in the health care literature and in national guidelines. Objectives: The objectives of the study were to identify characteristics of individual residents, and the organisational features of the homes in which they live, which may affect adherence to wearing hip protectors. Design: An observational, correlation study designed to identify factors related to adherence. Setting: Forty nursing and residential homes in the UK. Participants: 1346 residents of the homes who were not confined to bed and with no pressure sore on the hip. Methods: The introduction of an evidence-based policy to offer Safehips hip protectors to residents free of charge and with support from a nurse facilitator. Adherence to wearing the hip protectors was observed over 72 weeks. Results: Initial acceptance of the hip protectors was 37.2%. Continued adherence was 23.9% at 24 weeks; 23.2% at 48 weeks; and 19.9% at 72 weeks. Greater adherence was associated with the following individual resident characteristics: a greater degree of dependency (95% CI 1.39 - m3.78) and cognitive impairment (95% CI 1.01 - 2.98); being male rather than female (95% CI 1.06 - 2.48). Greater adherence was also associated with the following organisational characteristics of homes: fewer changes of senior manager during the study period (95% CI 1.01 - 8.51), and being resident in a home with a resident profile showing a greater proportion of residents with a higher degree of dependency (95% CI 1.04 - 1.27). There was wide a variation in the degree of success in implementation between homes (adherence of 0 - 100% at 24 weeks). Conclusions: Those implementing a policy of introducing hip protectors into nursing and residential homes should consider targeting residents with cognitive impairment. Such residents are at greater risk of hip fracture and appear to be more likely to continue wearing hip protectors. Those charged with implementing changes inpractice or policy should consider how the context for implementation can be optimised to increase the likelihood of success.