789 resultados para Heart Arrest
Resumo:
The aim of the present study is to analyse the influence of different large-sided games (LSGs) on the physical and physiological variables in under-12s (U12) and -13s (U13) soccer players. The effects of the combination of different number of players per team, 7, 9, and 11 (P7, P9, and P11, respectively) with three relative pitch areas, 100, 200, and 300 m(2) (A100, A200, and A300, respectively), were analysed in this study. The variables analysed were: 1) global indicator such as total distance (TD); work:rest ratio (W:R); player-load (PL) and maximal speed (V-max); 2) heart rate (HR) mean and time spent in different intensity zones of HR (<75%, 75-84%, 84-90% and >90%), and; 3) five absolute (<8, 8-13, 13-16 and >16 Km h(-1)) and three relative speed categories (<40%, 40-60% and >60% V-max). The results support the theory that a change in format (player number and pitch dimensions) affects no similarly in the two players categories. Although it can seem that U13 players are more demanded in this kind of LSG, when the work load is assessed from a relative point of view, great pitch dimensions and/or high number of player per team are involved in the training task to the U12 players. The results of this study could alert to the coaches to avoid some types of LSGs for the U12 players such as:P11 played in A100, A200 or A300, P9 played in A200 or A300 and P7 played in A300 due to that U13>U12 in several physical and physiological variables (W:R, time spent in 84-90% HRmax, distance in 8-13 and 13-16 Km h(-1) and time spent in 40-60% V-max). These results may help youth soccer coaches to plan the progressive introduction of LSGs so that task demands are adapted to the physiological and physical development of participants.
Resumo:
Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer's hands and the manikin's chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8-10.3), 6.3% (2.9-11.3), and 2.5% (1.2-4.4) for depth and 1.7% (0.0-2.3), 0.0% (0.0-2.0), and 0.9% (0.4-1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.
Resumo:
The localization of the stretch sensitivity and myogenic automatism in the systemic heart of Octopus vulgaris has been studied on an isolated preparation in which the ventricle was zoned by ligatures. Each region has been submitted to two different levels of internal hydrostatic pressure (1 and 2 kPa). Only the two atrio-ventricular regions were able to contract regularly when submitted to internal pressure, with a frequency dependent from the pressure value, while the ventricle-aortic region was insensitive to the stretching by internal pressure. This result supports the hypothesis that the automatism in this heart is localized. Electrocardiogram recordings from different areas of an isolated and perfused preparation of the systemic heart ventricle are also reported, which suggest that the electrical activity of the ventricle originates in two narrow areas near the atrio-ventricular valves.
Resumo:
The liver, heart and muscle tissues of Rohu, (Labeo rohita, Hamilton) were examined for their ubiquinone (UQ) and tocopherol contents. These three tissues contained respectively 11.60, 3.94 and 0.19 mg of ubiquinone and 10.16, 5.32 and 3.58 mg of tocopherol per 100 g. The 4% (V/V) of diethyl ether (EE) in light petroleum ether (PE) fractions of all three tissues on paper chromatographic separation gave spots having the same Rf value as standard ubiquinone-50 (UQ 10). Both the 4% and 6% (V/V) diethyl ether in light petroleum ether fraction of liver, heart and muscle tissues gave a single spot with the same Rf value as α – tocopherol.
Resumo:
The effect of AC and DC electric stimulations on the heart-rate and the entire body of Heteropneustis fossillis, Tilapia mossambica and Macrobrachium rosenbergii were studied and presented in kymograph tracings. The reaction of spinal cord in Puntius ticto, Heteropneustis fossilis and Tilapia mossambica to D. C. field was observed to find out its role in electric shocks. A test-check of the electrical resistance of a few species was also conducted. The effect of D. C. and A.C. on the body muscle was found to be the same as that in the case of frog. Different degrees of cardiac slowing were observed in AC and DC. Unbalanced galvanotropic movements were also noticed in spinal fishes.
Resumo:
The triglyceride fatty acid components from the heart lipid of Puntius sarana of different sizes have been characterized by thin-layer and gas liquid chromatography. Csub(10) to Csub(24) acids including both odd-numbered and branched chain acids were detected. The major constituents were ante-iso Csub(10), Csub(10), Csub(12:2), Csub(14), Csub(16), Csub(16:1),Csub(17), Csub(18) , Csub(18:1), Csub(18:2), Csub(18:3) and Csub(20:4) while twenty other acids were detected in lower proportion. The composition of these acids and their variation with size of fish have been investigated and discussed.
Resumo:
The effect of adenosine on the function of the heart in Octopus vulgaris was studied using an isolated heart preparation. Bolus injections of adenosine or AMP (adenosine precursor) induced both positive chronotropic and inotropic effects. The maximum inotropic effect preceded the maximum chronotropic effect. The impermeable adenosine analogue 2-chloroadenosine elicited a similar effect, while the adenosine uptake blocker dipyridamole did not affect the adenosine response. These results suggest that adenosine acted extracellularly. The concentration-response curves of adenosine and AMP were also determined, by evaluating the effects on ventricular and coronary function. Under these conditions, the potent chronotropic effect elicited by both substances apparently masked or compensated for the inotropic effect, owing to the negative force-frequency relationship known to occur in the octopus heart. The AMP displayed a lower threshold than adenosine, suggesting an higher affinity for the purinergic receptors involved or a strict association between 5'-nucleotidase and the adenosine receptor on the plasma membrane.
Resumo:
Tor mahseer (Tor tor), possess high commercial and recreational value as they are potential game as well as food fish of India. Two cell culture systems were developed from fin and heart of T. tor (Hamilton-Buchanan). The explants excised aseptically from fingerling of T. tor were cultured in Leibovitz-15 (L-15) medium with 20% fetal bovine serum (FBS). Radiation of cells started after 72 hours and 48 hours of explant attachment from caudal fin and heart respectively. Confluent monolayer of cells with heterogeneous morphology around fin explants was observed after 7-10 days, where as a homogenous confluent layer of fibroblastic cells from heart explant was observed after 12-13 days. The establishment of cell culture systems from different organs and tissues of commercial important species would facilitates in vitro research.