338 resultados para HOA microphone


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL).


Methods. Eighteen eyes participated in this study: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength.


Results. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P < 0.05). Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant.


Conclusions. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in young eyes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multiple-iteration constrained conjugate gradient (MICCG) algorithm and a single-iteration constrained conjugate gradient (SICCG) algorithm are proposed to realize the widely used frequency-domain minimum-variance-distortionless-response (MVDR) beamformers and the resulting algorithms are applied to speech enhancement. The algorithms are derived based on the Lagrange method and the conjugate gradient techniques. The implementations of the algorithms avoid any form of explicit or implicit autocorrelation matrix inversion. Theoretical analysis establishes formal convergence of the algorithms. Specifically, the MICCG algorithm is developed based on a block adaptation approach and it generates a finite sequence of estimates that converge to the MVDR solution. For limited data records, the estimates of the MICCG algorithm are better than the conventional estimators and equivalent to the auxiliary vector algorithms. The SICCG algorithm is developed based on a continuous adaptation approach with a sample-by-sample updating procedure and the estimates asymptotically converge to the MVDR solution. An illustrative example using synthetic data from a uniform linear array is studied and an evaluation on real data recorded by an acoustic vector sensor array is demonstrated. Performance of the MICCG algorithm and the SICCG algorithm are compared with the state-of-the-art approaches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper underscores the dynamic and complex dimensions of ‘becoming’ an intercultural doctoral student. It employs autobiography as a research method to portray the reshaping of ourselves as doctoral students to help us engage in self-reflexivity on our mediation of academic, personal and cultural identities in international doctoral education. Our self-narratives on how the plurality of our doctoral identities has emerged and how we have mediated these multiple identities show that becoming an intercultural research student is intimately linked to the process of self-empowerment and re-construction of oneself as a flexible and reflexive intercultural learner and human being. The paper concludes by discussing the notion of ‘reciprocal intercultural supervision’ in doctoral education. It highlights the increased need for (Western) supervisors to develop reciprocal interculturality and the capacity for greater agency in their international doctoral students so that both groups can understand each other better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identifying risks relevant to a software project and planning measures to deal with them are critical to the success of the project. Current practices in risk assessment mostly rely on high-level, generic guidance or the subjective judgements of experts. In this paper, we propose a novel approach to risk assessment using historical data associated with a software project. Specifically, our approach identifies patterns of past events that caused project delays, and uses this knowledge to identify risks in the current state of the project. A set of risk factors characterizing “risky” software tasks (in the form of issues) were extracted from five open source projects: Apache, Duraspace, JBoss, Moodle, and Spring. In addition, we performed feature selection using a sparse logistic regression model to select risk factors with good discriminative power. Based on these risk factors, we built predictive models to predict if an issue will cause a project delay. Our predictive models are able to predict both the risk impact (i.e. the extend of the delay) and the likelihood of a risk occurring. The evaluation results demonstrate the effectiveness of our predictive models, achieving on average 48%-81% precision, 23%-90% recall, 29%-71% F-measure, and 70%-92% Area Under the ROC Curve. Our predictive models also have low error rates: 0.39-0.75 for Macro-averaged Mean Cost-Error and 0.7-1.2 for Macro-averaged Mean Absolute Error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examine the effect of herding behaviour on the credit quality of bank loans in Australia. We find that bank herding varies with different types of loans. It tends to be more prevalent in owner-occupied housing loans and credit cards than other types of loans. During the global financial crisis period, herding in owner-occupied housing loans was most pronounced due to the flight-to-quality phenomenon in the housing sector. Furthermore, we find that the big four banks tend to herd more than smaller and regional banks. Bank herding behaviour is countercyclical, as it is negatively related to real GDP growth and the cost of funding but is positively related to market risk. Regulatory capital requirements may also encourage herding as banks are required to hold less risk-weighted capital for residential loans. Most importantly, bank herding is related to higher impaired assets and therefore lower loan quality. Our findings may have implications for policymakers and bank regulators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Students watch monitors that show a voltage meter being filmed in the Automotive Dept by department head William C. H. Meyer as part of a demonstration of a new technique in closed-circuit television. This is one of a series of photographs accompanying a press release about the development and demonstration of the new technique at the New York Trade School. Original caption reads, "In a classroom on another floor, students all have "front row" seats for the demonstration. Camera concentrates on close-up of a meter, where readings show the result of the voltage-regulator check. Instructor (standing at microphone) is Arthur Richards." Black and white photograph with accompanying caption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação consiste no estudo comparativo entre três tipos básicos de protetores auriculares do tipo concha (modelo simples de baixo preço e baixo NRR, modelo sofisticado, de maior custo e com NRR elevado, e modelo ativo com circuito eletrônico de cancelamento de ruído), tanto quanto ao conforto quanto às reais atenuações oferecidas pelos mesmos, num ambiente industrial com elevados níveis de ruído e de baixa freqüência (com predominância na faixa de 500 Hz). Para a análise dos protetores foram utilizadas a técnica MIRE (Miniature Microphone in Real-Ear, ou Microfone Miniatura no Ouvido Real) de avaliação do nível de atenuação, o uso de questionários de conforto, e medições de cortisol urinário, para a avaliação do estresse no trabalho. Os resultados indicaram que o protetor ativo não apresentou os resultados esperados em termos de atenuação, o que não justifica o seu elevado custo, e apresentou a pior condição de conforto entre os três tipos estudados. As medições do cortisol urinário, por sua vez, não apresentaram resultados que pudessem ser úteis na escolha do melhor modelo de protetor tipo concha.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

VoiceThread (VT) is a collaborative and asynchronous web 2.0 tool, which permits the creation of oral presentations with the help of images, documents, texts and voice, allowing groups of people to browse and contribute with comments using several options: voice (microphone or cell phone), text and audio-file or video (webcam) (BOTTENTUIT JUNIOR, LISBÔA E COUTINHO, 2009). The hybrid experience with VoiceThread allows learners to plan their speech before recording it, without the pressure often existent in the classroom. Furthermore, the presentations can be recorded several times, enabling students to listen to them, notice the gaps in their oral production (noticing) and edit innumerous times before publishing them online. In this perspective, oral production is seen as a process of L2 acquisition, not only as practice of already existent knowledge, because it can stimulate the learner to process the language syntactically (SWAIN, 1985; 1995). In this context, this study aims to verify if there is a relation between the oral production of the learners more specifically the grammatical accuracy and the global oral grade and their noticing capacity, how the systematic practice with VoiceThread, in a hybrid approach, can impact the learners global oral development, their oral production in terms of fluency (number of words per minute), accuracy (number of errors in hundred words), and complexity (number of dependent clauses per minute), and on their noticing capacity (SCHMIDT, 1990; 1995; 2001), that is, the learner s capacity of noticing the gaps existent in their oral production. In order to answer these research questions, 49 L2 learners of English were divided into an experimental group (25 students) and a control group (24 students). The experimental group was exposed to the hybrid approach with VT during two months and, through a pre- and post-test, we verified if this systematic practice would positively influence these participants oral production and noticing capacity. These results were compared to the pre- and post-test scores from the control group, which was not exposed to VT. Finally, learners impressions in relation to the use of this tool were also sought through a questionnaire applied after the post-test. The results indicate that there is a statistically significant correlation between the learners speech production (accuracy and global oral grade) and their noticing capacity. Besides, it was verified a positive impact of VoiceThread on the learners speech production variables and on their noticing capacity. They also reveal a positive reaction by the learners in relation to the hybrid experience with this web tool

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-audio signals have been recorded in the flash ROM memory of a portable MP3 player, in WAV format file, to examine the possibility of using these cheap and small instruments as general-purpose portable data loggers. A 1200-Hz FM carrier modulated by the non-audio signal has replaced the microphone signal, while using the REC operating mode of the MP3 player, which triggers the voice recording function. The signal recovery was carried out by a PLL-based FM demodulator whose input is the FM signal captured in the coil leads of the MP3 player's earphone. Sinusoidal and electrocardiogram signals have been used in the system evaluation. Although the quality of low frequency signals needs improvement, overall the results indicate the viability of the proposal. Suggestions are made for improvements and extensions of the work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the main environmental cues for the adjustment of temporal organization of the animals is the light-dark cycle (LD), which undergoes changes in phase duration throughout the seasons. Photoperiod signaling by melatonin in mammals allows behavioral changes along the year, as in the activity-rest cycle, in mood states and in cognitive performance. The aim of this study was to investigate if common marmoset (Callithrix jacchus) exhibits behavioral changes under short and long photoperiods in a 24h cycle, assessing their individual behaviors, vocal repertoire, exploratory activity (EA), recognition memory (RM) and the circadian rhythm of locomotor activity (CRA). Eight adult marmosets were exposed to a light-dark cycle of 12:12; LD 08:16; LD 12:12 and LD 16:08, sequentially, for four weeks in each condition. Locomotor activity was recorded 24h/day by passive infrared motion detectors above the individual cages. A video camera system was programmed to record each animal, twice a week, on the first two light hours. From the videos, frequency of behaviors was registered as anxiety-like, grooming, alert, hanging position, staying in nest box and feeding using continuous focal animal sampling method. Simultaneously, the calls emitted in the experimental room were recorded by a single microphone centrally located and categorized as affiliative (whirr, chirp), contact (phee), long distance (loud shrill), agonistic (twitter) and alarm (tsik, seep, see). EA was assessed on the third hour after lights onset on the last week of each condition. In a first session, marmosets were exposed to one unfamiliar object during 15 min and 24h later, on the second session, a novel object was added to evaluate RM. Results showed that long days caused a decreased of amplitude and period variance of the CRA, but not short days. Short days decreased the total daily activity and active phase duration. On long days, active phase duration increased due to an advance of activity onset in relation to symmetric days. However, not all subjects started the activity earlier on long days. The activity offset was similar to symmetric days for the majority of marmosets. Results of EA showed that RM was not affected by short or long days, and that the marmosets exhibited a decreased in duration of EA on long days. Frequency and type of calls and frequency of anxiety-like behaviors, staying in nest box and grooming were lower on the first two light hours on long days. Considering the whole active phase of marmosets as we elucidate the results of vocalizations and behaviors, it is possible that these changes in the first two light hours are due to the shifting of temporal distribution of marmoset activities, since some animals did not advance the activity onset on long days. Consequently, the marmosets mean decreased because the sampling was not possible. In conclusion, marmosets synchronized the CRA to the tested photoperiods and as the phase angle varied a lot among marmosets it is suggested that they can use different strategies. Also, long days had an effect on activity-rest cycle and exploratory behaviors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Características como a freqüência de ressonância da orelha externa e da orelha média podem interferir na captação das emissões otoacústicas. OBJETIVO: Investigar a influência da freqüência de ressonância da orelha externa e da orelha média na resposta das emissões otoacústicas. DESENHO CIENTÍFICO: Estudo de série, prospectivo, clínico. MATERIAL E MÉTODO: Foram feitas medidas com microfone-sonda na orelha externa, timpanometria de multifreqüência e teste de emissões otoacústicas por transitório e produto de distorção em 19 orelhas direitas e 20 orelhas esquerdas de indivíduos do sexo masculino e 23 orelhas direitas e 23 orelhas esquerdas de indivíduos do sexo feminino com 17 a 30 anos. As 85 orelhas eram audiologicamente normais. RESULTADOS: Não foram observadas relações estatisticamente significantes entre a melhor freqüência de emissões otoacústicas e a freqüência de ressonância da orelha externa oclusa e da orelha média. CONCLUSÃO: Os níveis de respostas das emissões otoacústicas por transitório e produto de distorção não são influenciadas apenas pela ressonância da orelha externa e da orelha média.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we developed a setup to measure the speed of sound in gases using a laser ultrasonics system. The mentioned setup is an all optical system composed by a Q-switched Nd:YAG laser to generate the sound waves, and a fiber optical microphone to detect them. The Nd:YAG provided a laser pulse of approximately 420 mJ energy and 9 ns of pulse width, at the wavelength of 1064 nm. The pulsed laser beam, focused by a positive lens, was used to generate an electrical breakdown (in the gas) which, in turn, generates an sound wave that traveled through a determined distance and reached the fiber optical microphone. The resulting signal was acquired in an oscilloscope and the time difference between the optical pulse and the arrival of the sound waves was used to calculate the speed of sound, since the distance was known. The system was initially tested to measure the speed of sound in air, at room pressure and temperature and it presented results in agreement with the theory, showing to be suitable to measure the speed of sound in gases. © 2012 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze the components of the acoustic signal of swallowing using a specific software. Methods: Fourteen healthy subjects ranging in age from 20 to 50 years (mean age 31±10 years), were evaluated. Data collection consisted on the simultaneous capture of the swallowing audio with a microphone and of the swallowing videofluoroscopic image. The bursts of the swallowing acoustic signal were identified and their duration and the interval between them were later analyzed using a specific software, which allowed the simultaneous analyses between the acoustic wave and the videofluoroscopic image. Results: Three burst components were identified in most of the swallows evaluated. The first burst presented mean time of 87.3 milliseconds (ms) for water and 78.2 for the substance. The second burst presented mean time of 112.9 ms for water and 85.5 for the pasty substance. The mean interval between first and second burst was 82.1 ms for water and 95.3 ms for the pasty consistency, and between second and third burst was 339.8 ms for water and 322.0 ms for the pasty consistency. Conclusion: The software allowed the visualization of three bursts during the swallowing of healthy individuals, and showed that the swallowing signal in normal subjects is highly variable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)