987 resultados para Glass ionomer cements – Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents the results of a cost-effectiveness analysis in a controlled clinical trial on the effectiveness of a modified glass ionomer resin sealant ( Vitremer, 3M ESPE) and the application of fluoride varnish (Duraphat, Colgate) on occlusal surfaces of first permanent molars in children 6-8 years of age (N = 268), according to caries risk (high versus low). Children were examined semiannually by the same calibrated dentist for 24 months after allocation in six groups: high and low risk controls (oral health education every three months); high and low risk with varnish (oral health education every three months + varnish biannually); and high and low risk with sealant (oral health education every three months + a single application of sealant). Economic analysis showed that sealing permanent first molars of high-risk schoolchildren showed a C/E ratio of US$ 119.80 per saved occlusal surface and an incremental C/E ratio of US$ 108.36 per additional saved occlusal surface. The study concluded that sealing permanent first molars of high-risk schoolchildren was the most cost-effective intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to comparatively assess the seven-year clinical performance of a one-bottle etch-and-rinse adhesive with resin composite (RC) and resin-modified glass ionomer (RMGI) restorations in noncarious cervical lesions.Methods and Materials: One operator placed 70 restorations (35 restorations in each group) in 30 patients under rubber dam isolation without mechanical preparation. The restorations were directly assessed by two independent examiners, using modified US Public Health Service criteria at baseline and 6, 12, 24, 60, and 84 months. The obtained data were tabulated and statistically analyzed using the Fisher and McNemar tests. A difference was significant if p<0.05.Results: Twenty patients were available for recall after seven years (66.6%), and 25 RC and 26 RMGI restorations out of 70 restorations were evaluated. Excellent agreement was registered for all criteria between examiners (kappa >= 0.85). Alfa and bravo scores were classified as clinically acceptable. The McNemar test detected significant differences within RC restorations between baseline and seven-year evaluations for anatomic form, marginal integrity, and retention (p<0.05). For RMGI restorations, a significant difference was identified for marginal integrity (p<0.05). As to material comparison, the Fisher exact showed a better retention performance for RMGI restorations than for RC restorations (p<0.05). Twelve composite restorations were dislodged (52.0% retention) and three ionomer restorations were lost (88.5% retention). The cumulative success rate for RC and RMGI was 30% and 58.1%, respectively.Conclusions: After seven years of service, the clinical performance of RMGI restorations was superior to that of the adhesive system/resin composite restorations in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the 12-month clinical performance of glass ionomer restorations in teeth with MIH. First permanent molars affected by MIH (48) were restored with glass ionomer cement (GIC) and evaluated at baseline, at 6 and at 12 months, by assessing tooth enamel breakdown, GIC breakdown and caries lesion associations. The data were analyzed using the chi-square test and actuarial survival analysis. The likelihood of a restored tooth remaining unchanged at the end of 12 months was 78%. No statistically significant difference was observed in the association between increased MIH severity and caries at baseline (p > 0.05) for a 6-month period, or between increased MIH severity and previous unsatisfactory treatment at baseline (p > 0.05) for both a 6- and 12-month period. A statistically significant difference was observed in the association between increased MIH severity and extension of the restoration, involving 2 or more surfaces (p < 0.05) at both periods, and between increased MIH severity and caries at baseline (p < 0.05) at a 12-month period. Because the likelihood of maintaining the tooth structures with GIC restorations is high, invasive treatment should be postponed until the child is sufficiently mature to cooperate with the treatment, mainly of teeth affected on just one face.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effect of ultrasonic vibration on the tensile strength required to remove intraradicular post cemented with different materials. Bovine teeth were selected, and 7 mm of the cervical root canals were prepared to size 5 Largo drill, the posts were cemented with zinc phosphate, Enforce (resin) or Rely X (glass ionomer). The specimens were divided into six groups (n = 10), according to the following procedures: GI-cementation with zinc phosphate associated with traction force; GII-cementation with zinc phosphate associated with ultrasonic activation and traction force; G111-cementation with Enforce associated with traction force; GIV-cementation with Enforce associated with ultrasonic activation and traction force; GV-cementation with Rely X associated with traction force; and GVI-cementation with Rely X associated with ultrasonic activation and traction force. The tensile test was conducted using the electromechanical testing machine, the force was determined by a specialized computer program and ultrasonic activation using the Jet Sonic Four Plus (Gnatus) device in 10P. Concerning to average ranking, GI showed statistically significant difference in comparison with GII and GVI (p < 0.05); there was no statistical difference in GIII and GIV when compared to other groups (p > 0.05). The ultrasound favored the intraradicular post traction regardless of the employed cement in greater or lesser extent. The post removal is a routine practice in the dental office, therefore, new solutions and better alternatives are need to the practitioner. We did not find in the literature many articles referring to this practice. Thus, the results from this study are relevant in the case planning and to promote more treatment options.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM Preparation of the lamina during osteo-odonto-keratoprosthesis (OOKP) design is complex, and its longevity and watertightness important. To date, only acrylic bone cements have been used for bonding the optical cylinder to the tooth dentine. Our aim was to evaluate different dental adhesives for OOKP preparation. METHODS Specimens of bovine teeth were produced by preparing 1.5-mm thick dentine slices with holes having a diameter of 3.5 mm. Each group (n=10 per group) was luted with either classic poly-(methyl methacrylate) (PMMA) bone cement, universal resin cement or glass ionomer cement. All specimens underwent force measurement using a uniaxial traction machine. RESULTS The highest mean force required to break the bond was measured for PMMA bone cement (128.2 N) followed by universal resin cement (127.9 N), with no statistically significant difference. Glass ionomer cement showed significantly lower force resistance (78.1 N). CONCLUSIONS Excellent bonding strength combined with easy application was found for universal resin cement, and thus, it is a potential alternative to acrylic bone cement in OOKP preparation.