870 resultados para Forced vibration tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a modified version of the classical Van der Pol oscillator is proposed, introducing fractional-order time derivatives into the state-space model. The resulting fractional-order Van der Pol oscillator is analyzed in the time and frequency domains, using phase portraits, spectral analysis and bifurcation diagrams. The fractional-order dynamics is illustrated through numerical simulations of the proposed schemes using approximations to fractional-order operators. Finally, the analysis is extended to the forced Van der Pol oscillator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

“Cork taint” is a major problem in wine industry and is caused by contamination of wines. This contamination is usually attributed to wine cork stoppers and 2,4,6-trichloroanisole (2,4,6-TCA) is one of the compounds mostly associated to this off-flavour. In this work, a consumer panel performed “forced choice” triangular tests in order to measure Odour Detection Thresholds (ODT) and Taste Detection Thresholds (TDT) of 2,4,6-TCA in water, hydro-alcoholic solutions (11.5% and 18% ethanol) and white and red wines. A paired preference test was also performed by the panel in order to measure Odour Rejection Threshold (ORT) in white and red wine spiked with 2,4,6-TCA. Results obtained show that the ODT and the TDT for 2,4,6-TCA in water were 0.2 and 0.3 ng/L, respectively. In hydro-alcoholic solutions with 11.5% and 18% ethanol the ODT were 4 and 10 ng/L respectively. In red wine the ODT and the TDT were 0.9 and 1.7 ng/L and in white wine were 1.5 and 1.0 ng/L respectively. ORT for white was 10.4 ng/L and for red wines 16.0 ng/L. These results suggest that although this group of consumers detected very low concentrations of 2,4,6-TCA in wines, they did not reject the wine at these low concentration values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to analyze the forearm muscular contraction levels associated to the use of anti-vibration gloves, by comparing the contraction levels with gloves and without gloves. Two different vibration tools were used in a simulated work environment: (1) A compact Duty Multi-Cutter Bosch and (2) and a Percussion Drill with a drill bit Ø20 mm. Standard operations were performed by each subject in the following materials: (1) Performing cross- sectional cuts in 80x40 mm pine section and (2) performing 20 mm diameter holes in a concrete slab 2 x 2 m, 70 mm thick. The forearm contraction level were measured by surface electromyography in four different muscles: Flexor Digitorum Superficialis (FDS), Flexor Carpi Ulnaris (FCU), Extensor Carpi Radialis Longus (ECRL) e Extensor Carpi Ulnaris (ECU). For the flexor muscles (FDS, FCU), an increase tendency in muscular contraction was observed when the operations are performed without gloves (2-5% MVE increase in the FDS and 3-9% MVE increase in the FCU). For the extensor muscles ECU a decrease tendency in muscular contraction was observed when the operations are performed without gloves (1-10% MVE decrease). Any tendency was found in the ECRL muscle. ECU was the muscle with the highest contraction level for 79% and 71% of the operators, during the operations respectively with the multi-cutter (P50= 27-30%MVE) and with the percussion drill (P50=46-55%MVE). As a final conclusion from this study, anti- vibration gloves may increase the forearm fatigue in the posterior region of the forearm (ECU muscle) during operations with the mentioned tools

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this contribution is to extend the models of cellular/composite material design to nonlinear material behaviour and apply them for design of materials for passive vibration control. As a first step a computational tool allowing determination of optimised one-dimensional isolator behaviour was developed. This model can serve as a representation for idealised macroscopic behaviour. Optimal isolator behaviour to a given set of loads is obtained by generic probabilistic metaalgorithm, simulated annealing. Cost functional involves minimization of maximum response amplitude in a set of predefined time intervals and maximization of total energy absorbed in the first loop. Dependence of the global optimum on several combinations of leading parameters of the simulated annealing procedure, like neighbourhood definition and annealing schedule, is also studied and analyzed. Obtained results facilitate the design of elastomeric cellular materials with improved behaviour in terms of dynamic stiffness for passive vibration control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passage of high-speed trains may induce high ground and track vibrations, which, besides increasing wheel, rail and track deterioration, may have a negative impact on the vehicle stability and on the passengers comfort. In this paper two distinct analyses are presented. The first one is dedicated to efficient decoupling of rail and soil vibrations by suggesting new interface materials in rail-sleeper fixing system, i.e. in the part where damping efficiency can be directly controlled and tested. The second analysis concerns with an adequate model of soils damping. Proper understanding and correct numerical simulation of this behaviour can help in suggesting soil improvement techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper refers to the assessment on site by semi-destructive testing (SDT) methods of the consolidation efficiency of a conservation process developed by Henriques (2011) for structural and non-structural pine wood elements in service. This study was applied on scots pine wood (Pinus sylvestris L.) degraded by fungi after treatment with a biocidal product followed by consolidation with a polymeric product. This solution avoids substitutions of wood moderately degraded by fungi, improving its physical and mechanical characteristics. The consolidation efficiency was assessed on site by methods of drill resistance and penetration resistance. The SDT methods used showed good sensitivity to the conservation process and could evaluate their effectiveness. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about a design of an urban area Darrieus VAWT, having self-start ability due to an innovative profile design named EN0005, avoiding the need of extra components or external electricity feed-in. An approach is presented to study the ability of a blade profile to offer self-start ability. Methodologies applied for the blade body and for profile development are reported. Field tests and main conclusions are presented to persuade for the arrangement of this design. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Task scheduling is one of the key mechanisms to ensure timeliness in embedded real-time systems. Such systems have often the need to execute not only application tasks but also some urgent routines (e.g. error-detection actions, consistency checkers, interrupt handlers) with minimum latency. Although fixed-priority schedulers such as Rate-Monotonic (RM) are in line with this need, they usually make a low processor utilization available to the system. Moreover, this availability usually decreases with the number of considered tasks. If dynamic-priority schedulers such as Earliest Deadline First (EDF) are applied instead, high system utilization can be guaranteed but the minimum latency for executing urgent routines may not be ensured. In this paper we describe a scheduling model according to which urgent routines are executed at the highest priority level and all other system tasks are scheduled by EDF. We show that the guaranteed processor utilization for the assumed scheduling model is at least as high as the one provided by RM for two tasks, namely 2(2√−1). Seven polynomial time tests for checking the system timeliness are derived and proved correct. The proposed tests are compared against each other and to an exact but exponential running time test.