876 resultados para Filtros ativos de potência
Resumo:
In this research it was studied a system composed by the anaerobic filter combined with a sand filter for the wastewater treatment. For this, three anaerobic filters were operated with hydraulic detention time of nine hours which had the effluent disposed over four sand filters in different frequencies of application. on the first sand filter, 50 L.m(-2) were applied once a day. on the second, the third and the fourth filters, the same load was disposed in twice, three and four times a day, distributed between 9 a. m. and 4 p. m. The system presented a final effluent suitable for the COD and BOD legislation maximum limit to be discharged into water body (Decreto Paulista no 8,468/1976), showing the viability of dispose a higher quantity of effluent then the one suggested by NBR 13969/1997, which guides the constructive aspects for this kind of treatment.
Resumo:
Prototypes A (bidin + broken stones + gravel stones + gross sand + activated coal) and B (bidin + broken stones + gravel stones + gross sand) under hydraulic charge of 35 cm presented outlets that, when extrapolated for larger filters, are sufficient to supply small and medium irrigation projects for vegetables and fruits. (bidin = Rhodia polyester for drainage). Under a charge of 35 cm, filtrate of both prototypes presented a reduction of fecal coliforms, being this reduction higher for A prototypes, but, even in this case, the coliform quantities were superior to the legal limit. Under a decrease of the biochemical oxygen demand an increase of the available oxygen rate; pH and hardness did not present significant changes.
Resumo:
The objective of this study was to analyze the relationship of maximal aerobic power and the muscular strength (maximal isotonic strength and vertical jump explosive power) with the running economy (RE) in endurance athletes. Twenty-six male runners (27.9 ± 6.4 years; 62.7 ± 4.3 kg; 168.6 ± 6.1 cm; 6.6 ± 3.1% of body fat) performed in different days the following tests: a) incremental test to determine the maximal oxygen uptake (V̇O2max) and the intensity corresponding to the V̇O2max (IV̇O2max); b) constant-velocity treadmill run to determine RE; c) 1-RM test in the leg press and; d) maximal vertical jump test (VJ). V̇O2max (63.8 ± 8.3 ml/kg/min) was significantly correlated (r = 0.63; p < 0.05) with RE (48.0 ± 6.6 ml/kg/min). However, the IV̇O2max (18.7 ± 1.1 km/h), the maximal isotonic strength (230.3 ± 41.2 kg) and the VJ (30.8 ± 3.8 cm) were not significantly correlated with RE. One concludes that the maximal aerobic power can explain in part the inter-individual RE variability in endurance athletes. However, maximal isotonic strength and explosive strength seem not to be associated with RE values observed in this group of athletes.
Resumo:
The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.
Resumo:
The main purpose of this study was to analyze the effect of the pedaling cadence (500 × 100 rpm) on the heart rate (HR) and the blood lactate response during incremental and constant workload exercises in active individuals. Nine active male individuals (20.9 ± 2.9 years old; 73.9 ± 6.5 kg; 1.79 ± 0.9 m) were submitted to two incremental tests, and to 6-8 constant workload tests to determine the intensity corresponding to the maximal steady state lactate (MLSSintens) in both cadences. The maximal power (Pmax) attained during the incremental test, and the MLSSintens were significantly lower at 100 rpm (240.9 ± 12.6 W; 148.1 ± 154.W) compared to 50 rpm (263.9 ± 18.6 W; 186.1 ± 21.2 W), respectively. The HRmax did not change between cadences (50 rpm = 191.1 ± 8.8 bpm; 100 rpm = 192.6 ± 9.9 bpm). Regardless the cadence, the HRmax percentage (70, 80, 90, and 100%) determined the same lactate concentrations during the incremental test. However, when the intensity was expressed in Pmax percentage or in absolute power, the lactate and the HR values were always higher at highest cadences. The HR corresponding to MLSSintens was similar between cadences (50 rpm = 162.5 ± 9.1 bpm; 100 rpm = 160.4 ± 9.2 bpm). Based on these results, it can be conclude that regardless the cadence employed (50 × 100 rpm), the use of the HR to individualize the exercise intensity indicates similar blood lactate responses, and this relationship is also kept in the exercise of constant intensity performed at MLSSintens. On the other hand, the use of the Pmax percentages depend on the cadence used, indicating different physiological responses to a same percentage.
Resumo:
The designs of filters made by granular material or textile are mainly based on empirical or semi empirical retention criteria according to Terzaghi proposal, which compares particle diameter of the soil base with the filter porous spaces. Silveira in 1965, proposed one rational design retention criteria based on the probability of a particle from the soil base, carried by one dimensional flow, be restrained by the porous of the filter while trying to pass through its thickness. This new innovating theory, besides of being very simple, it is not frequently used for granular filters since the necessary parameters for the design has to be determine for each natural material. However, for textile this problem no longer exists because it has quality control during manufacturing and the necessary characteristics properties of the product are specify in the product catalog. This work presents one adaptation of the Silveira theory for textile filters and the step-by-step procedure for the determination of the characteristics properties of the textile products necessary for the design. This new procedure permits the determination of the confiability level of retention that one specific particle diameter form the soil base has for one specified textile. One complete example is presented to demonstrate the simplicity of the method proposed and how the textile characteristics are obtained.
Resumo:
This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.
Resumo:
Sickle cell disease (SCD) is a hereditary hemolytic anemia caused by the inheritance of one S hemoglobin gene from each ancestor. Patients with SCD present increased circulating levels of cytokines, including TNF-alpha (TNF-α). Hydroxyurea (HU) is the available therapeutically strategy for treatment; it acts as a source of nitric oxide and benefits patients by increasing the levels of fetal hemoglobin (HbF). Thus, within one research line that aims at finding new drugs, a series of compounds with TNF-α inhibition and nitric oxide donation properties have been synthesized in order to explore possible synergism of actions beneficial in the treatment of the disease. Six compounds were synthesized: five derivatives of organic nitrates and one of sulfonamide. The compounds, (1,3-dioxo-1,3-dihydro-2Hisoindol-2-yl) methyl nitrate (compound I); (1,3-dioxo-1,3-dihydro-2H-isoindol-2-yl) ethyl nitrate (compound II); 3-(1,3-dioxo-1,3-dihydro-2H-isoindol-2-yl) benzyl nitrate (compound III);4-(1,3-dioxo-1,3-dihydro-2H-isoindol-2-yl)-N-hydroxybenzenesulfonamide (compound IV); 4-(1,3-dioxo-1,3-dihydro-2H-isoindol-2-yl) benzyl nitrate (compound V) and 2-[4-(1,3-dioxo-1,3-dihydro-2H-isoindol-2-yl) phenyl]ethyl nitrate (compound VI), were synthesized using linear synthetic methodology, with excellent overall yields. All compounds showed anti-inflammatory and analgesic effects with a reduction in 43%-65% of ear edema in mice and a reduction of 25%-42% of writhing induced by acetic acid. All compounds showed comparable reductions in the leukocyte infiltration capacity and ability to generate nitric oxide. The aryl compounds (III, IV and V) presented less mutagenic activity compared to compounds I, II and VI according to the salmonella mutagenicity assay (Ames test). Compounds IV and VI showed activity in K562 culture cells, with increases in gamma globin gene expression to levels higher than with hydroxyurea suggesting a potential to increase fetal hemoglobin. This data set characterizes new potentially useful drug candidates for the treatment of symptoms of sickle cell anemia.
Resumo:
In this paper the point estimation method is applied to solve the probabilistic power flow problem for unbalanced three-phase distribution systems. Through the implementation of this method the probability distribution functions of voltages (magnitude and angle) as well as the active and reactive power flows in the branches of the distribution system are determined. Two different approaches of the point estimation method are presented (2m and 2m+1 point schemes). In order to test the proposed methodology, the IEEE 34 and 123 bus test systems are used. The results obtained with both schemes are compared with the ones obtained by a Monte Carlo Simulation (MCS).
Resumo:
The maximal oxygen uptake (VO2max) is the maximal quantity of energy that can be produced by the aerobic metabolism in certain time unity. It can be determined direct or indirectly by predictive equations. The objective of this study was to make a specific predictive equation to determine the VO 2max from boys aged 10-16 years-old. Forty-two boys underwent a treadmill running ergospirometric test, with the initial velocity set at 9 km/h, until voluntary exhaustion. By the multiple linear regression was possible to develop the following equation for the indirect determination of the VO 2max: VO2max (ml/min) = -1574.06 + (141.38 x Vpeak) + (48.34 * Body mass), with standard error of estimate = 191.5 ml/min (4.10 ml/kg/min) and coefficient of determination = 0.934. We suggest that this formula is appropriate to predict VO2max for this population.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)