908 resultados para Error of measurement


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper is the first to examine the implications of switching to PT work for women's subsequent earnings trajectories, distinguishing by their type of contract: permanent or fixedterm. Using a rich longitudinal Spanish data set from Social Security records of over 76,000 prime-aged women strongly attached to the Spanish labor market, we find that PT work aggravates the segmentation of the labor market insofar there is a PT pay penalty and this penalty is larger and more persistent in the case of women with fixed-term contracts. The paper discusses problems arising in empirical estimation (including a problem not discussed in the literature up to now: the differential measurement error of the LHS variable by PT status), and how to address them. It concludes with policy implications relevant for Continental Europe and its dual structure of employment protection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Although glycogen (Glyc) is the main carbohydrate storage component, the role of Glyc in the brain during prolonged wakefulness is not clear. The aim of this study was to determine brain Glyc concentration ([]) and turnover time (tau) in euglycemic conscious and undisturbed rats, compared to rats maintained awake for 5h. To measure the metabolism of [1-(13)C]-labeled Glc into Glyc, 23 rats received a [1-(13)C]-labeled Glc solution as drink (10% weight per volume in tap water) ad libitum as their sole source of exogenous carbon for a "labeling period" of either 5h (n=13), 24h (n=5) or 48 h (n=5). Six of the rats labeled for 5h were continuously maintained awake by acoustic, tactile and olfactory stimuli during the labeling period, which resulted in slightly elevated corticosterone levels. Brain [Glyc] measured biochemically after focused microwave fixation in the rats maintained awake (3.9+/-0.2 micromol/g, n=6) was not significantly different from that of the control group (4.0+/-0.1 micromol/g, n=7; t-test, P>0.5). To account for potential variations in plasma Glc isotopic enrichment (IE), Glyc IE was normalized by N-acetyl-aspartate (NAA) IE. A simple mathematical model was developed to derive brain Glyc turnover time as 5.3h with a fit error of 3.2h and NAA turnover time as 15.6h with a fit error of 6.5h, in the control rats. A faster tau(Glyc) (2.9h with a fit error of 1.2h) was estimated in the rats maintained awake for 5h. In conclusion, 5h of prolonged wakefulness mainly activates glycogen metabolism, but has minimal effect on brain [Glyc].

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The movement of the upper limbs (eg fidgeting-like activities) is a meaningful component of nonexercise activity thermogenesis (NEAT). This study examined the relationship between upper limb movements and whole body trunk movements, by simultaneously measuring energy expenditure during the course of the day. DESIGN: A cross-sectional study consisting of 88 subjects with a wide range in body mass index (17.3-32.5 kg/m(2)). The energy expenditure over a 24-h period was measured in a large respiratory chamber. The body movements were assessed by two uniaxial-accelerometers during daytime, one on the waist and the other on the dominant arm. The accelerometry scores from level 0 (=immobile) up to level 9 (=maximal intensity) were recorded. The activities of subjects were classified into eight categories: walking at two speeds on a horizontal treadmill (A & B), ambling (C), self-care tasks (D), desk work (E), meals (F), reading (G), watching TV (H). RESULTS: There was a significant relationship between the accelerometry scores from the waist (ACwaist) and that from the wrist (ACwrist) over the daytime period (R(2)=0.64; P<0.001). The ACwrist was systematically higher than the ACwaist during sedentary activities, whereas it was the reverse for walking activities. ACwrist to ACwaist ratio of activities E-H were above 1.0 and for walking activities (A-C) were below 1.0. A multiple regression analysis for predicting daytime energy expenditure revealed that the explained variance improved by 2% only when the ACwrist was added as a second predictor in addition to the ACwaist. This indicates that the effect of the ACwrist for predicting energy expenditure was of limited importance in our conditions of measurement. CONCLUSIONS: The acceleration of the upper limbs which includes fidgeting is more elevated than that of the whole body for sitting/lying down activities. However, their contribution to energy expenditure is lower than whole body trunk movements, thus indicating that the weight-bearing locomotion activities may be a key component of NEAT. However, its contribution may depend on the total duration of the upper limb movements during the course of the day.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Els sistemes automatitzats que requereixen d’un control d’estabilitat o moviment es poden trobar cada cop en més àmbits. Aplicacions UAV o de posicionament global són les més comunes per aquest tipus de sistemes, degut a que necessiten d’un control de moviment molt precís. Per a dur a terme aquest procés s’utilitzen unitats de mesura inercial, que mitjançant acceleròmetres i giroscopis degudament posicionats, a més a més d’una correcció del possible error que puguin introduir aquests últims, proporcionen una acceleració i una velocitat angular de les quals es pot extreure el camí efectuat per aquestes unitats. La IMU, combinada amb un GPS i mitjançant un filtre de Kalman, proporcionen una major exactitud , a més d’un punt de partida (proporcionat per el GPS), un recorregut representable en un mapa y, en el cas de perdre la senyal GPS, poder seguir adquirint dades de la IMU. Aquestes dades poden ser recollides i processades per una FPGA, que a la vegada podem sincronitzar amb una PDA per a que l’usuari pugui veure representat el moviment del sistema. Aquest treball es centra en el funcionament de la IMU i l’adquisició de dades amb la FPGA. També introdueix el filtre de Kalman per a la correcció de l’error dels sensors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The reported prevalence of late-life depressive symptoms varies widely between studies, a finding that might be attributed to cultural as well as methodological factors. The EURO-D scale was developed to allow valid comparison of prevalence and risk associations between European countries. This study used Confirmatory Factor Analysis (CFA) and Rasch models to assess whether the goal of measurement invariance had been achieved; using EURO-D scale data collected in 10 European countries as part of the Survey of Health, Ageing and Retirement in Europe (SHARE) (n = 22,777). The results suggested a two-factor solution (Affective Suffering and Motivation) after Principal Component Analysis (PCA) in 9 of the 10 countries. With CFA, in all countries, the two-factor solution had better overall goodness-of-fit than the one-factor solution. However, only the Affective Suffering subscale was equivalent across countries, while the Motivation subscale was not. The Rasch model indicated that the EURO-D was a hierarchical scale. While the calibration pattern was similar across countries, between countries agreement in item calibrations was stronger for the items loading on the affective suffering than the motivation factor. In conclusion, there is evidence to support the EURO-D as either a uni-dimensional or bi-dimensional scale measure of depressive symptoms in late-life across European countries. The Affective Suffering sub-component had more robust cross-cultural validity than the Motivation sub-component.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coronary artery calcification (CAC) is quantified based on a computed tomography (CT) scan image. A calcified region is identified. Modified expectation maximization (MEM) of a statistical model for the calcified and background material is used to estimate the partial calcium content of the voxels. The algorithm limits the region over which MEM is performed. By using MEM, the statistical properties of the model are iteratively updated based on the calculated resultant calcium distribution from the previous iteration. The estimated statistical properties are used to generate a map of the partial calcium content in the calcified region. The volume of calcium in the calcified region is determined based on the map. The experimental results on a cardiac phantom, scanned 90 times using 15 different protocols, demonstrate that the proposed method is less sensitive to partial volume effect and noise, with average error of 9.5% (standard deviation (SD) of 5-7mm(3)) compared with 67% (SD of 3-20mm(3)) for conventional techniques. The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Cobalamin C methylmalonic aciduria with homocystinuria (cblC disease) is a rare hereditary inborn error of cobalamin metabolism, characterised by neurological, haematological and ophthalmological abnormalities. PATIENTS AND METHODS: Three consecutive patients with Cblc disease were examined. Investigations included slit lamp and fundus examination and full-field ERG. RESULTS: A maculopathy associated with both photopic and scotopic abnormal ERG was present in two cases and a salt and pepper retinopathy with abnormal photopic ERG was detected in the third patient. CONCLUSIONS: Despite early treatment and regular metabolic controls, all our patients exhibited both retinal and ERG abnormalities. There was no correlation between funduscopic appearance and the type of photoreceptor dysfunction. A literature review disclosed a retinopathy in 29 / 70 cases with cblC disease, with an abnormal ERG in 8 of the 12 tested cases, most with retinopathy. Retinal dysfunction in cblC disease may be more frequent than previously thought, and can involve cones only or both rods and cones. We recommend a formal ocular examination with full-field ERG in patients with Cblc disease.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The principal aim of this study was to develop a Swiss Food Frequency Questionnaire (FFQ) for the elderly population for use in a study to investigate the influence of nutritional factors on bone health. The secondary aim was to assess its validity and both short-term and long-term reproducibility. DESIGN: A 4-day weighed record (4 d WR) was applied to 51 randomly selected women of a mean age of 80.3 years. Subsequently, a detailed FFQ was developed, cross-validated against a further 44 4-d WR, and the short- (1 month, n = 15) and long-term (12 months, n = 14) reproducibility examined. SETTING: French speaking part of Switzerland. SUBJECTS: The subjects were randomly selected women recruited from the Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture cohort study. RESULTS: Mean energy intakes by 4-d WR and FFQ showed no significant difference [1564.9 kcal (SD 351.1); 1641.3 kcal (SD 523.2) respectively]. Mean crude nutrient intakes were also similar (with nonsignifcant P-values examining the differences in intake) and ranged from 0.13 (potassium) to 0.48 (magnesium). Similar results were found in the reproducibility studies. CONCLUSION: These findings provide evidence that this FFQ adequately estimates nutrient intakes and can be used to rank individuals within distributions of intake in specific populations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. While ground UV irradiance is monitored via different techniques, it is difficult to translate such observations into human UV exposure or dose because of confounding factors. A multi-disciplinary collaboration developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop a simulation tool that estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. Dosimetric measurements obtained in field conditions were used to assess the model performance. The model predicted exposure to solar UV adequately with a symmetric mean absolute percentage error of 13% and half of the predictions within 17% range of the measurements. Using this tool, solar UV exposure patterns were investigated with respect to the relative contribution of the direct, diffuse and reflected radiation. Exposure doses for various body parts and exposure scenarios of a standing individual were assessed using erythemally-weighted UV ground irradiance data measured in 2009 at Payerne, Switzerland as input. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 Standard Erythemal Dose, SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e. g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Résumé en français: L'hyperémie réactive dans la microcirculation musculature et cutanée de l'avant-bras permet d'évaluer l'atteinte vasculaire dans les maladie cardiovasculaires. Cette méthode permet d'obtenir un reflet de la progression de l'atteinte vasculaire, de traquer la progression de la maladie ainsi que le risque cardio-vasculaires. Elle est en étude également pour tester l'efficacité d'une intervention thérapeutique. L'hyperémie réactive est dépendante d'une dilatation post ischémique par diminution des résistances artériolaires. Au niveau des membres, l'ischémie peut-être débutée et interrompue très facilement par une manchette à pression gonflée au-dessus de la pression systolique suivie quelques minutes plus tard de son dégonflement. Les mesures de flux sanguin musculaire et cutané au niveau d'un membre sont facile à réaliser chez l'homme, tout particulièrement au niveau de l'avant-bras. Pour l'instant aucune étude utilisant cette approche ne spécifiait quel avant-bras était utilisé. Il est cependant concevable que la réponse varie selon que l'on teste le bras dominant ou non-dominant. Il parait donc important de clarifier ce point. Le premier but de l'étude consiste donc à investiguer une éventuelle différence entre le bras dominant et le bras non-dominant d'un sujet lors de tests de l'hyperémie réactive dans le muscle et la peau. Il est connu que l'hyperémie réactive au niveau musculaire peut-être diminuée par les médicaments antiinflammatoires non stéro~idiens (AINS), indiquant une implication partielle des métabolites de la cyclo-oxygénase. L'influence des AINS sur la réponse cutanée est moins clairement établie. Ainsi, le second but de cette étude est de comparer l'effet de l'inhibition de la cyclo-oxygénase sur l'hyperémie réactive musculaire et cutanée chez des sujets sains. Le collectif de patients consiste en 23 sujets masculins volontaires, en bonne santé, non fumeurs, de 18 à 30 ans. Aucuns antécédents médicaux ne sont connus et aucune médication n'est prise durant la période de l'étude. Tous . les sujets ont donné leur consentement par écrit. Le flux sanguin musculaire de l'avant-bras est mesuré au moyen d'une pléthysmographie par occlusion veineuse, et le flux cutané l'est par imagerie laser Doppler. Les expériences ont lieu entre 16 et 18 h dans une chambre calme à température constante (23-24°C) chez un sujet couché. Les participants n'ont pas consommé d'AINS durant la semaine précédente ni bu de café dans les 12 h précédant l'expérience. Les mesures sont effectuées en triplicat au niveau musculaire puis cutané ou inversement selon un ordre aléatoire. Suite à une occlusion artérielle l'étude du flux se fait sur 3 min et 5 min de récupération sont prises entre 2 mesures. L'expérience 1 consiste à tester un possible effet systématique de la latéralisation du bras dominant ou non sur la réponse à l'hyperémie réactive dans la peau et le muscle de l'avant-bras. 16 sujets sont étudiés à 2 reprises, espacées de 1 à 3 jours. A la première visite, l'hyperémie musculaire est étudiée dans un avant-bras, la réaction cutanée dans l'autre et inversement lors de la deuxième visite. Une précaution est observée afin de mesurer le flux sanguin cutané à la même distance du poignet dans les 2 avant-bras. L'expérience 2 est développée pour évaluer l'impact d'une inhibition des cyclo-oxygénases. Sept sujet sont considérés à 2 occasions espacées de 7 à 10 j. L'étude s'effectue uniquement au niveau de l'avant-bras dominant. Le site cutané au niveau du poignet est marqué lors de la première visite afin d'utiliser le même site de mesure lors de la seconde visite. Le sujet ingère 1,8 g d'Aspegic (équivalant à 1 g d'acide acétylsalilcylique) dissout dans 125 ml de jus d'orange ou le jus d'orange seul lors de l'autre visite selon un ordre randomisé. Les mesures sont débutées 2 h après la prise. Summary Reactive hyperemia (RH) in forearm muscle or skin microcirculation has been considered as a surrogate endpoint in clinical studies of cardiovascular disease. We evaluated two potential confounders that might limit such use of RH, namely laterality of measurement and intake of non-steroidal anti-inflammatory drugs (NSAIDS). Twenty-three young non-smoking healthy adults were enrolled. In Experiment 1 (n=16), the RH elicited by 3 min of ischemia was recorded in the muscle (strain gauge plethysmography, hand excluded) and skin (laser Doppler imaging) of both forearms. In Experiment 2 (n=7), RH was determined in the dominant forearm only, one hour following oral acetylsalicylic acid (1 g) or placebo. In Experiment 1, peak RH was identical in both forearms, and so were the corresponding durations of responses. RH lasted significantly less in muscle than in skin (p=0.003), a hitherto unrecognized fact. In the skin, acetylsalicylate reduced duration (43 vs 57.4 s for placebo, p=0.03), without affecting the peak response. In muscle, duration tended to decrease with acetylsalicylate (21.4 vs 26.0 s with placebo, p=0.06) and the peak increase in blood flow was blunted (27.2 vs 32.4 ml/min/100 ml tissue with placebo, p=0.003). We conclude that, when using RH as a surrogate endpoint in studies of cardiovascular disease, a confounding by laterality of measurement need not be feared, but NSAIDS may have an influence, although perhaps not on the peak response in the skin.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We introduce simple nonparametric density estimators that generalize theclassical histogram and frequency polygon. The new estimators are expressed as linear combination of density functions that are piecewisepolynomials, where the coefficients are optimally chosen in order to minimize the integrated square error of the estimator. We establish the asymptotic behaviour of the proposed estimators, and study theirperformance in a simulation study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Organizations often face the challenge of communicating their strategiesto local decision makers. The difficulty presents itself in finding away to measure performance wich meaningfully conveys how to implement theorganization's strategy at local levels. I show that organizations solvethis communication problem by combining performance measures in such away that performance gains come closest to mimicking value-added asdefined by the organization's strategy. I further show how organizationsrebalance performance measures in response to changes in their strategies.Applications to the design of performance metrics, gaming, and divisionalperformance evaluation are considered. The paper also suggests severalempirical ways to evaluate the practical importance of the communicationrole of measurement systems.