861 resultados para Electronic instrumentation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonlocal approximations for the electronic exchange and correlation effects are used to compute, within density-functional theory, the polarizability and surface-plasma frequencies of small jelliumlike alkali-metal clusters. The results are compared with those obtained using the local-density approximation and with available experimental data, showing the relevance of these effects in obtaining an accurate description of the surface response of metallic clusters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study documents the speed reduction impacts of two dynamic, electronic school zone speed limit signs at United Community Schools between Ames and Boone, Iowa. The school facility is situated along US Highway 30, a rural four-lane divided expressway. Due to concerns about high speeds in the area, the Iowa Department of Transportation (DOT) decided to replace the original static school zone speed limit signs, which had flashing beacons during school start and dismissal times (Figure 1), with electronic speed signs that only display the reduced school speed limit of 55 mph during school arrival and dismissal times (Figure 2). The Center for Transportation Research and Education (CTRE) at Iowa State University (ISU) conducted a speed evaluation study one week before and 1 month, 7 months, and 14 or 15 months after the new signs were installed. Overall, the new dynamic school zone speed limit signs were more effective in reducing speeds than the original static signs with flashing beacons in the 1 month after period. During the 7 and 14 month after period, speeds increased slightly for the eastbound direction of traffic. However, the increases were consistent with overall speed increases that occurred independent of the signs. The dynamic, electronic signs were effective for the westbound direction of traffic for all time periods and for both start and dismissal times. Even though only modest changes in mean and 85th percentile speeds occurred, with the speed decreases, the number of vehicles exceeding the school speed limit decreased significantly, indicating the signs had a significant impact on high-end speeders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ground state structure of few-electron concentric double quantum rings is investigated within the local spin density approximation. Signatures of inter-ring coupling in the addition energy spectrum are identified and discussed. We show that the electronic configurations in these structures can be greatly modulated by the inter-ring distance: At short and long distances the low-lying electron states localize in the inner and outer rings, respectively, and the energy structure is essentially that of an isolated single quantum ring. However, at intermediate distances the electron states localized in the inner and the outer ring become quasidegenerate and a rather entangled, strongly-correlated system is formed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review of the Department of Natural Resources Parks Reservation System and the Electronic Licensing System for Iowa for the period July 1, 2006 through June 30, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This phase of the electronic collaboration project involved two major efforts: 1) implementation of AEC Sync (formerly known as Attolist), a web-based project management system (WPMS), on the Broadway Viaduct Bridge Project and the Iowa Falls Arch Bridge Project and 2) development of a web-based project management system for bridge and highway construction projects with less than $10 million in contract value. During the previous phase of this project (fiscal year 2010), the research team helped with the implementation process for AEC Sync and collected feedback from the Broadway Viaduct project team members before the start of the project. During the 2011 fiscal year, the research team collected the post-project surveys from the Broadway Viaduct project members and compared them to the pre-project survey results. The results of the AEC Sync implementation on the Broadway project were positive. The project members were satisfied with the performance of the AEC Sync software and how it facilitated document management and its transparency. In addition, the research team distributed, collected, and analyzed the pre-project surveys for the Iowa Falls Arch Bridge Project. The implementation of AEC Sync for the Iowa Falls Arch Bridge Project appears to also be positive, based on the pre-project surveys. The fourth phase of this electronic collaboration project involves the identification and implementation of a WPMS solution for smaller bridge and highway projects. The workflow for the shop drawing approval process for sign truss projects was documented and used to identify possible WPMS solutions. After testing and evaluating several WPMS solutions, Microsoft SharePoint Foundation’s site pages were selected to be pilot-tested on sign truss projects. Due to the limitation on the SharePoint license that the Iowa Department of Transportation (DOT) has, a file transfer protocol (FTP) site will be developed alongside this site to allow contractors to upload shop drawings to the Iowa DOT. The SharePoint site pages are expected to be ready for implementation during the 2012 calendar year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One-dimensional arrays of nonlinear electronic circuits are shown to support propagation of pulses when operating in a locally bistable regime, provided the circuits are under the influence of a global noise. These external random fluctuations are applied to the parameter that controls the transition between bistable and monostable dynamics in the individual circuits. As a result, propagating fronts become destabilized in the presence of noise, and the system self-organizes to allow the transmission of pulses. The phenomenon is also observed in weakly coupled arrays, when propagation failure arises in the absence of noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare our experience with minimally invasive transforaminal lumbar interbody fusion (MITLIF) and open midline transforaminal lumbar interbody fusion (TLIF). A total of 36 patients suffering from isthmic spondylolisthesis or degenerative disc disease were operated with either a MITLIF (n = 18) or an open TLIF technique (n = 18) with an average follow-up of 22 and 24 months, respectively. Clinical outcome was assessed using the visual analogue scale (VAS) and the Oswestry disability index (ODI). There was no difference in length of surgery between the two groups. The MITLIF group resulted in a significant reduction of blood loss and had a shorter length of hospital stay. No difference was observed in postoperative pain, initial analgesia consumption, VAS or ODI between the groups. Three pseudarthroses were observed in the MITLIF group although this was not statistically significant. A steeper learning effect was observed for the MITLIF group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural and electronic properties of Cu2O have been investigated using the periodic Hartree-Fock method and a posteriori density-functional corrections. The lattice parameter, bulk modulus, and elastic constants have been calculated. The electronic structure of and bonding in Cu2O are analyzed and compared with x-ray photoelectron spectroscopy spectra, showing a good agreement for the valence-band states. To check the quality of the calculated electron density, static structure factors and Compton profiles have been calculated, showing a good agreement with the available experimental data. The effective electron and hole masses have been evaluated for Cu2O at the center of the Brillouin zone. The calculated interaction energy between the two interpenetrated frameworks in the cuprite structure is estimated to be around -6.0 kcal/mol per Cu2O formula. The bonding between the two independent frameworks has been analyzed using a bimolecular model and the results indicate an important role of d10-d10 type interactions between copper atoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This brochure explains Iowa's laws concerning the use of cell phones and other electronic communication devices while driving.