888 resultados para Edge detection method


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two-dimensional optical power distribution of the out-coupled radiation from UV-inscribed tilted fibre Bragg gratings (TFBGs) in multimode fibre (MMF) has been side-detected with high spatial/spectral resolution, showing a near-identical radiation mode profile to that measured from the fibre-end detection method. A comparative investigation of the radiation characteristics of TFBGs fabricated in singlemode fibre (SMF) and MMF clearly indicates that the radiation out-coupling is stronger and spatially more confined in MMF. The unique spatial-to-spectral encoding property of the coupling mechanism offers potential application in low-cost WDM devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ernst Mach observed that light or dark bands could be seen at abrupt changes of luminance gradient in the absence of peaks or troughs in luminance. Many models of feature detection share the idea that bars, lines, and Mach bands are found at peaks and troughs in the output of even-symmetric spatial filters. Our experiments assessed the appearance of Mach bands (position and width) and the probability of seeing them on a novel set of generalized Gaussian edges. Mach band probability was mainly determined by the shape of the luminance profile and increased with the sharpness of its corners, controlled by a single parameter (n). Doubling or halving the size of the images had no significant effect. Variations in contrast (20%-80%) and duration (50-300 ms) had relatively minor effects. These results rule out the idea that Mach bands depend simply on the amplitude of the second derivative, but a multiscale model, based on Gaussian-smoothed first- and second-derivative filtering, can account accurately for the probability and perceived spatial layout of the bands. A key idea is that Mach band visibility depends on the ratio of second- to first-derivative responses at peaks in the second-derivative scale-space map. This ratio is approximately scale-invariant and increases with the sharpness of the corners of the luminance ramp, as observed. The edges of Mach bands pose a surprisingly difficult challenge for models of edge detection, but a nonlinear third-derivative operation is shown to predict the locations of Mach band edges strikingly well. Mach bands thus shed new light on the role of multiscale filtering systems in feature coding. © 2012 ARVO.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two-dimensional optical power distribution of the out-coupled radiation from UV-inscribed tilted fibre Bragg gratings (TFBGs) in multimode fibre (MMF) has been side-detected with high spatial/spectral resolution, showing a near-identical radiation mode profile to that measured from the fibre-end detection method. A comparative investigation of the radiation characteristics of TFBGs fabricated in singlemode fibre (SMF) and MMF clearly indicates that the radiation out-coupling is stronger and spatially more confined in MMF. The unique spatial-to-spectral encoding property of the coupling mechanism offers potential application in low-cost WDM devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background To determine the pharmacokinetics (PK) of a new i.v. formulation of paracetamol (Perfalgan) in children ≤15 yr of age. Methods After obtaining written informed consent, children under 16 yr of age were recruited to this study. Blood samples were obtained at 0, 15, 30 min, 1, 2, 4, 6, and 8 h after administration of a weight-dependent dose of i.v. paracetamol. Paracetamol concentration was measured using a validated high-performance liquid chromatographic assay with ultraviolet detection method, with a lower limit of quantification (LLOQ) of 900 pg on column and an intra-day coefficient of variation of 14.3% at the LLOQ. Population PK analysis was performed by non-linear mixed-effect modelling using NONMEM. Results One hundred and fifty-nine blood samples from 33 children aged 1.8–15 yr, weight 13.7–56 kg, were analysed. Data were best described by a two-compartment model. Only body weight as a covariate significantly improved the goodness of fit of the model. The final population models for paracetamol clearance (CL), V1 (central volume of distribution), Q (inter-compartmental clearance), and V2 (peripheral volume of distribution) were: 16.51×(WT/70)0.75, 28.4×(WT/70), 11.32×(WT/70)0.75, and 13.26×(WT/70), respectively (CL, Q in litres per hour, WT in kilograms, and V1 and V2 in litres). Conclusions In children aged 1.8–15 yr, the PK parameters for i.v. paracetamol were not influenced directly by age but were by total body weight and, using allometric size scaling, significantly affected the clearances (CL, Q) and volumes of distribution (V1, V2).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two-dimensional optical power distribution of the out-coupled radiation from UV-inscribed tilted fibre Bragg gratings (TFBG) in multimode fibre (MMF) has been side-detected with high spatial spectral resolution, showing a near-identical radiation mode profile to that measured from the fibre-end detection method. A comparative investigation of the radiation characteristics of TFBGs fabricated in singlemode fibre (SMF) and MMF clearly indicates that the radiation out-coupling is stronger and spatially more confined in MMF. The unique spatial-to-spectral encoding property of the coupling mechanism offers potential application in low-cost WDM devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims: To establish the sensitivity and reliability of objective image analysis in direct comparison with subjective grading of bulbar hyperaemia. Methods: Images of the same eyes were captured with a range of bulbar hyperaemia caused by vasodilation. The progression was recorded and 45 images extracted. The images were objectively analysed on 14 occasions using previously validated edge-detection and colour-extraction techniques. They were also graded by 14 eye-care practitioners (ECPs) and 14 non-clinicians (NCb) using the Efron scale. Six ECPs repeated the grading on three separate occasions Results: Subjective grading was only able to differentiate images with differences in grade of 0.70-1.03 Efron units (sensitivity of 0.30-0.53), compared to 0,02-0.09 Efron units with objective techniques (sensitivity of 0.94-0.99). Significant differences were found between ECPs and individual repeats were also inconsistent (p<0.001). Objective analysis was 16x more reliable than subjective analysis. The NCLs used wider ranges of the scale but were more variable than ECPs, implying that training may have an effect on grading. Conclusions: Objective analysis may offer a new gold standard in anterior ocular examination, and should be developed further as a clinical research tool to allow more highly powered analysis, and to enhance the clinical monitoring of anterior eye disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: To use previously validated image analysis techniques to determine the incremental nature of printed subjective anterior eye grading scales. Methods: A purpose designed computer program was written to detect edges using a 3 × 3 kernal and to extract colour planes in the selected area of an image. Annunziato and Efron pictorial, and CCLRU and Vistakon-Synoptik photographic grades of bulbar hyperaemia, palpebral hyperaemia roughness, and corneal staining were analysed. Results: The increments of the grading scales were best described by a quadratic rather than a linear function. Edge detection and colour extraction image analysis for bulbar hyperaemia (r2 = 0.35-0.99), palpebral hyperaemia (r2 = 0.71-0.99), palpebral roughness (r2 = 0.30-0.94), and corneal staining (r2 = 0.57-0.99) correlated well with scale grades, although the increments varied in magnitude and direction between different scales. Repeated image analysis measures had a 95% confidence interval of between 0.02 (colour extraction) and 0.10 (edge detection) scale units (on a 0-4 scale). Conclusion: The printed grading scales were more sensitive for grading features of low severity, but grades were not comparable between grading scales. Palpebral hyperaemia and staining grading is complicated by the variable presentations possible. Image analysis techniques are 6-35 times more repeatable than subjective grading, with a sensitivity of 1.2-2.8% of the scale.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The offered paper deals with the problems of color images preliminary procession. Among these are: interference control (local ones and noise) and extraction of the object from the background on the stage preceding the process of contours extraction. It was considered for a long time that execution of smoothing in segmentation through the boundary extraction is inadmissible, but the described methods and the obtained results evidence about expedience of using the noise control methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Good estimates of ecosystem complexity are essential for a number of ecological tasks: from biodiversity estimation, to forest structure variable retrieval, to feature extraction by edge detection and generation of multifractal surface as neutral models for e.g. feature change assessment. Hence, measuring ecological complexity over space becomes crucial in macroecology and geography. Many geospatial tools have been advocated in spatial ecology to estimate ecosystem complexity and its changes over space and time. Among these tools, free and open source options especially offer opportunities to guarantee the robustness of algorithms and reproducibility. In this paper we will summarize the most straightforward measures of spatial complexity available in the Free and Open Source Software GRASS GIS, relating them to key ecological patterns and processes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objectives of this research are to analyze and develop a modified Principal Component Analysis (PCA) and to develop a two-dimensional PCA with applications in image processing. PCA is a classical multivariate technique where its mathematical treatment is purely based on the eigensystem of positive-definite symmetric matrices. Its main function is to statistically transform a set of correlated variables to a new set of uncorrelated variables over $\IR\sp{n}$ by retaining most of the variations present in the original variables.^ The variances of the Principal Components (PCs) obtained from the modified PCA form a correlation matrix of the original variables. The decomposition of this correlation matrix into a diagonal matrix produces a set of orthonormal basis that can be used to linearly transform the given PCs. It is this linear transformation that reproduces the original variables. The two-dimensional PCA can be devised as a two successive of one-dimensional PCA. It can be shown that, for an $m\times n$ matrix, the PCs obtained from the two-dimensional PCA are the singular values of that matrix.^ In this research, several applications for image analysis based on PCA are developed, i.e., edge detection, feature extraction, and multi-resolution PCA decomposition and reconstruction. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Context: Due to a unique combination of factors, outdoor athletes in the Southeastern United States are at high risk of lightning deaths and injuries. Lightning detection methods are available to minimize lightning strike victims. Objective: Becoming aware of the risk factors that predispose athletes to lightning strikes and determining the most reliable detection method against hazardous weather will enable Certified Athletic Trainers to develop protocols that protect athletes from injury. Data Sources: A comprehensive literature review of Medline and Pubmed using key words: lightning, lightning risk factors, lightning safety, lightning detection, and athletic trainers and lightning was completed. Data Synthesis: Factors predisposing athletes to lighting death or injury include: time of year, time of day, the athlete’s age, geographical location, physical location, sex, perspiration level, and lack of education and preparedness by athletes and staff. Although handheld lightning detectors have become widely accessible to detect lightning strikes, their performance has not been independently or objectively confirmed. There is evidence that these detectors inaccurately detect strike locations by recording false strikes and not recording actual strikes. Conclusions: Lightning education and preparation are two factors that can be controlled. Measures need to be taken by Certified Athletic Trainers to ensure the safety of athletes during outdoor athletics. It is critical for athletic trainers and supervising staff members to become fully aware of the risks of lightning strikes in order to most effectively protect everyone under their supervision. Even though lightning detectors have been manufactured in an attempt to minimize death and injuries due to lightning strikes, none of the detectors have been proven to be 100% effective. Educating coaches, athletes, and parents on the risks of lightning and the detection methods available, while implementing an emergency action plan for lightning safety, is crucial to ensure the well being of the student-athlete population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In 2001, a weather and climate monitoring network was established along the temperature and aridity gradient between the sub-humid Moroccan High Atlas Mountains and the former end lake of the Middle Drâa in a pre-Saharan environment. The highest Automated Weather Stations (AWS) was installed just below the M'Goun summit at 3850 m, the lowest station Lac Iriki was at 450 m. This network of 13 AWS stations was funded and maintained by the German IMPETUS (BMBF Grant 01LW06001A, North Rhine-Westphalia Grant 313-21200200) project and since 2011 five stations were further maintained by the GERMAN DFG Fennec project (FI 786/3-1), this way some stations of the AWS network provided data for almost 12 years from 2001-2012. Standard meteorological variables such as temperature, humidity, and wind were measured at an altitude of 2 m above ground. Other meteorological variables comprise precipitation, station pressure, solar irradiance, soil temperature at different depths and for high mountain station snow water equivalent. The stations produced data summaries for 5-minute-precipitation-data, 10- or 15-minute-data and a daily summary of all other variables. This network is a unique resource of multi-year weather data in the remote semi-arid to arid mountain region of the Saharan flank of the Atlas Mountains. The network is described in Schulz et al. (2010) and its further continuation until 2012 is briefly discussed in Redl et al. (2015, doi:10.1175/MWR-D-15-0223.1) and Redl et al. (2016, doi:10.1002/2015JD024443).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work was performing effluent degradation studies by electrochemical treatment. The electrochemical oxidation (EO) hydroquinone (H2Q) was carried out in acid medium, using PbO2 electrode by galvanostatic electrolysis, applying current densities of 10 and 30 mA/cm2 . The concentration of H2Q was monitored by differential pulse voltammetry (DPV). The experimental results showed that the galvanostatic electrolysis process performance significantly depends on the applied current density, achieving removal efficiencies of 100% and 80 % and 10 applying 30 mA/cm2 , respectively. Furthermore, the electroanalytical technique was effective in H2Q be used as a detection method. In order to test the efficiency of PbO2 electrode, the electrochemical treatment was conducted in an actual effluent, leachate from a landfill. The liquid waste leachate (600ml effluent) was treated in a batch electrochemical cell, with or without addition of NaCl by applying 7 mA/cm2 . The efficiency of EO was assessed against the removal of thermo-tolerant coliforms, total organic carbon (TOC), total phosphorus and metals (copper, cobalt, chromium, iron and nickel). These results showed that efficient removal of coliforms was obtained (100%), and was further decrease the concentration of heavy metals by the cathode processes. However, results were not satisfactory TOC, achieving low total removal of dissolved organic load. Because it is considered an effluent complex were developed other tests with this effluent to monitor a larger number of decontamination parameters (Turbidity, Total Solids, Color, Conductivity, Total Organic Carbon (TOC) and metals (barium, chromium, lithium, manganese and Zinc), comparing the efficiency of this type of electrochemical treatment (EO or electrocoagulation) using a flow cell. In this assay was compared to electro streaming. In the case of the OE, Ti/IrO2-TaO5 was used as the anode, however, the electrocoagulation process, aluminum electrodes were used; applying current densities of 10, 20 and 30 mA/cm2 in the presence and absence of NaCl as an electrolyte. The results showed that EO using Ti/IrO2–TaO5 was anode as efficient when Cl- was present in the effluent. In contrast, the electrocoagulation flow reduces the dissolved organic matter in the effluent, under certain experimental conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nell'ambito dell'elaborazione delle immagini, si definisce segmentazione il processo atto a scomporre un'immagine nelle sue regioni costituenti o negli oggetti che la compongono. Ciò avviene sulla base di determinati criteri di appartenenza dei pixel ad una regione. Si tratta di uno degli obiettivi più difficili da perseguire, anche perché l'accuratezza del risultato dipende dal tipo di informazione che si vuole ricavare dall'immagine. Questa tesi analizza, sperimenta e raffronta alcune tecniche di elaborazione e segmentazione applicate ad immagini digitali di tipo medico. In particolare l'obiettivo di questo studio è stato quello di proporre dei possibili miglioramenti alle tecniche di segmentazione comunemente utilizzate in questo ambito, all'interno di uno specifico set di immagini: tomografie assiali computerizzate (TAC) frontali e laterali aventi per soggetto ginocchia, con ivi impiantate protesi superiore e inferiore. L’analisi sperimentale ha portato allo sviluppo di due algoritmi in grado di estrarre correttamente i contorni delle sole protesi senza rilevare falsi punti di edge, chiudere eventuali gap, il tutto a un basso costo computazionale.