1000 resultados para E-qualidade do serviço


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent decades, changes have been occurring in the telecommunications industry, allied to competition driven by the policies of privatization and concessions, have fomented the world market irrefutably causing the emergence of a new reality. The reflections in Brazil have become evident due to the appearance of significant growth rates, getting in 2012 to provide a net operating income of 128 billion dollars, placing the country among the five major powers in the world in mobile communications. In this context, an issue of increasing importance to the financial health of companies is their ability to retain their customers, as well as turn them into loyal customers. The appearance of infidelity from customer operators has been generating monthly rates shutdowns about two to four percent per month accounting for business management one of its biggest challenges, since capturing a new customer has meant an expenditure greater than five times to retention. For this purpose, models have been developed by means of structural equation modeling to identify the relationships between the various determinants of customer loyalty in the context of services. The original contribution of this thesis is to develop a model for loyalty from the identification of relationships between determinants of satisfaction (latent variables) and the inclusion of attributes that determine the perceptions of service quality for the mobile communications industry, such as quality, satisfaction, value, trust, expectation and loyalty. It is a qualitative research which will be conducted with customers of operators through simple random sampling technique, using structured questionnaires. As a result, the proposed model and statistical evaluations should enable operators to conclude that customer loyalty is directly influenced by technical and operational quality of the services offered, as well as provide a satisfaction index for the mobile communication segment

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the performanee analysis of traffie retransmission algorithms pro¬posed to the HCCA medium aeeess meehanism of IEEE 802.11 e standard applied to industrial environmen1. Due to the nature of this kind of environment, whieh has eleetro¬magnetic interferenee, and the wireless medium of IEEE 802.11 standard, suseeptible to such interferenee, plus the lack of retransmission meehanisms, refers to an impraetieable situation to ensure quality of service for real-time traffic, to whieh the IEEE 802.11 e stan¬dard is proposed and this environment requires. Thus, to solve this problem, this paper proposes a new approach that involves the ereation and evaluation of retransmission al-gorithms in order to ensure a levei of robustness, reliability and quality of serviee to the wireless communication in such environments. Thus, according to this approaeh, if there is a transmission error, the traffie scheduler is able to manage retransmissions to reeo¬ver data 10s1. The evaluation of the proposed approaeh is performed through simulations, where the retransmission algorithms are applied to different seenarios, whieh are abstrae¬tions of an industrial environment, and the results are obtained by using an own-developed network simulator and compared with eaeh other to assess whieh of the algorithms has better performanee in a pre-defined applieation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This dissertation has the purpose to present a portable device named PlugData MG100G, equipped with a cellular module, to analyze the radiofrequency coverage in a GSM network situated in João Pessoa city, state of Paraíba, at four distinct regions. The equipment, originally, was developed to be used in fixed environments, so it was adapted so that it could be used in conditions of mobility. From the Mobile Measurement Reports (MMRs) RF coverage and the handover process are analyzed. The MMRs enable the identification of the serving cell and the list of the closest neighboring cells monitored by the mobile. This work analyses only data referent to the serving cell and the two closest neighboring cells. Inter-cell and intra-cell handovers are identified. The frequency planning and quality of service offered by the network related to the regions are discussed as well

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of wireless telecommunication in the last years has been great. It has been taking academics to conceive new ideas and techniques. Their aims are to increase the capacity and the quality of the system s services. Cells that are smaller every time, frequencies that are every time higher and environments that get more and more complex, all those facts deserve more accurate models the propagation prediction techniques are inserted in this context and results with a merger of error that is compatible with the next generations of communication systems. The objective of this Work is to present results of a propagation measurement campaign, aiming at pointing the characteristics of the mobile systems covering in the city of Natal (state of Rio Grande do Norte, Brazil). A mobile laboratory was set up, using the infra-structure available and frequently used by ANATEL. The measures were taken in three different areas: one characterized by high buildings, high relief, presence of trees and towers of different highs. These areas covered the city s central zone, a suburban / rural zone and a section of coast surrounded by sand dunes. It is important to highlight that the analysis was made taking into consideration the actual reality of cellular systems with covering ranges by reduced cells, with the intent of causing greater re-use of frequencies and greater capacity of telephone traffic. The predominance of telephone traffic by cell in the city of Natal occurs within a range inferior to 3 (three) km from the Radio-Base Station. The frequency band used was 800 MHz, corresponding to the control channels of the respective sites, which adopt the FSK modulation technique. This Dissertation starts by presenting a general vision of the models used for predicting propagation. Then, there is a description of the methodology used in the measuring, which were done using the same channels of control of the cellular system. The results obtained were compared with many existing prediction models, and some adaptations were developed by using regression techniques trying to obtain the most optimized solutions. Furthermore, according to regulations from the old Brazilian Holding Telebrás, a minimum covering of 90% of a determined previously area, in 90% of the time, must be obeyed when implanting cellular systems. For such value to be reached, considerations and studies involving the specific environment that is being covered are important. The objective of this work is contribute to this aspect

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It s notorious the advance of computer networks in recent decades, whether in relation to transmission rates, the number of interconnected devices or the existing applications. In parallel, it s also visible this progress in various sectors of the automation, such as: industrial, commercial and residential. In one of its branches, we find the hospital networks, which can make the use of a range of services, ranging from the simple registration of patients to a surgery by a robot under the supervision of a physician. In the context of both worlds, appear the applications in Telemedicine and Telehealth, which work with the transfer in real time of high resolution images, sound, video and patient data. Then comes a problem, since the computer networks, originally developed for the transfer of less complex data, is now being used by a service that involves high transfer rates and needs requirements for quality of service (QoS) offered by the network . Thus, this work aims to do the analysis and comparison of performance of a network when subjected to this type of application, for two different situations: the first without the use of QoS policies, and the second with the application of such policies, using as scenario for testing, the Metropolitan Health Network of the Federal University of Rio Grande do Norte (UFRN)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Modern wireless systems employ adaptive techniques to provide high throughput while observing desired coverage, Quality of Service (QoS) and capacity. An alternative to further enhance data rate is to apply cognitive radio concepts, where a system is able to exploit unused spectrum on existing licensed bands by sensing the spectrum and opportunistically access unused portions. Techniques like Automatic Modulation Classification (AMC) could help or be vital for such scenarios. Usually, AMC implementations rely on some form of signal pre-processing, which may introduce a high computational cost or make assumptions about the received signal which may not hold (e.g. Gaussianity of noise). This work proposes a new method to perform AMC which uses a similarity measure from the Information Theoretic Learning (ITL) framework, known as correntropy coefficient. It is capable of extracting similarity measurements over a pair of random processes using higher order statistics, yielding in better similarity estimations than by using e.g. correlation coefficient. Experiments carried out by means of computer simulation show that the technique proposed in this paper presents a high rate success in classification of digital modulation, even in the presence of additive white gaussian noise (AWGN)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The growing accumulation of people in urban centers caused chronic problems of the cities to begin to take an increasingly unsustainable. Primarily related to lack of infrastructure coupled with sanitation and lack of investment in critical sectors such as health, education, housing and transportation, these problems start to deteriorate markedly the quality of life of city dwellers and put into test management policies of the spaces urbanized. To reverse this situation, shows is essential to the use of tools (highlighting this harvest rates and environmental indicators) that help in assessing the current conditions and may assist in predicting future scenarios. From the information listed above, now put the research seeks to present an index called ISBA Environmental (Sanitation Index) which looks at the four urban systems (water, sewer, solid waste and urban drainage) from the viewpoint of application in a geographical cutout specific - in this case the Drainage Basin XII, defined by the Plan of Urban Drainage Stormwater in the city of Natal, capital of Rio Grande do Norte. This index, together with analysis of other factors sought to trace the current conditions of the basin and thus, assist in proposing the best solutions. For the preparation of the index was applied a questionnaire with a sample of 384 (three hundred eighty-four) households that aimed to study two variables: access to services and satisfaction of the population in relation to these. The ISBA has shown that the system is the most deficient collection and disposal of effluents (ICE = 47.66%), followed by the drainage of rainwater (IDAP = 54.17%), water supply (AAI = 61, 36) and solid waste collection (IRS = 78.28). With the ISBA was possible to verify that the qualitative data shows whose subjectivity is evident (as is the case of user satisfaction) can be of great importance when an assessment, since we obtained the correlation coefficient between the variables "Access" and " Satisfaction "equal to 0.8234, showing a strong correlation between the existence / quality of service offered and the impressions of the population that receives them

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to analyze the work of social workers at the Hospital Universitário Onofre Lopes (HUOL), with the analytical approach the contracting process with the HUOL with the National Health System (SUS), which is set from 2004. Thus, this study sought in times of state reform, restructuring and tension between enlargement / reduction of social and labor rights, understanding the limits and possibilities of social work in HUOL, analyzing how these determinations bounce in the practice of social workers included in the collective process of health work. From a theoretical and methodological historical and dialectical materialism, we conducted literature search, in which developed book report and readings of texts, articles, books that focus on the central categories of the study, namely: Work, Social Work, Health, Health Reform , Project ethical and professional politician. Operationalized also a documentary research, on the Brazilian Public Health Policy, (SUS) and of the Education, as well as research field in which we conducted interviews with 11 social workers, employees packed the HUOL. We conclude that social workers did not participate in the discussion process of contracting the HUOL with the Municipal Health Secretariat of Natal, RN, manager of health and full resetting of user access, via reference setting - counter-referral services provided by the hospital brought the main demands on Social Work guidance regarding the functionality of SUS, and the social intervention in the struggle to guarantee such access. However, the data show that the expansion of demands that require the intervention of the social worker at HUOL is not associated with quantitative growth of these professionals need. Such conditions inflect the possibilities of materialization of the professional ethical-political project, even though that these professionals worry and seek the intellectual improvement, quality of service and to guarantee the social rights of users in the professional practice everyday

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One of the current challenges of Ubiquitous Computing is the development of complex applications, those are more than simple alarms triggered by sensors or simple systems to configure the environment according to user preferences. Those applications are hard to develop since they are composed by services provided by different middleware and it is needed to know the peculiarities of each of them, mainly the communication and context models. This thesis presents OpenCOPI, a platform which integrates various services providers, including context provision middleware. It provides an unified ontology-based context model, as well as an environment that enable easy development of ubiquitous applications via the definition of semantic workflows that contains the abstract description of the application. Those semantic workflows are converted into concrete workflows, called execution plans. An execution plan consists of a workflow instance containing activities that are automated by a set of Web services. OpenCOPI supports the automatic Web service selection and composition, enabling the use of services provided by distinct middleware in an independent and transparent way. Moreover, this platform also supports execution adaptation in case of service failures, user mobility and degradation of services quality. The validation of OpenCOPI is performed through the development of case studies, specifically applications of the oil industry. In addition, this work evaluates the overhead introduced by OpenCOPI and compares it with the provided benefits, and the efficiency of OpenCOPI s selection and adaptation mechanism

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context-aware applications are typically dynamic and use services provided by several sources, with different quality levels. Context information qualities are expressed in terms of Quality of Context (QoC) metadata, such as precision, correctness, refreshment, and resolution. On the other hand, service qualities are expressed via Quality of Services (QoS) metadata such as response time, availability and error rate. In order to assure that an application is using services and context information that meet its requirements, it is essential to continuously monitor the metadata. For this purpose, it is needed a QoS and QoC monitoring mechanism that meet the following requirements: (i) to support measurement and monitoring of QoS and QoC metadata; (ii) to support synchronous and asynchronous operation, thus enabling the application to periodically gather the monitored metadata and also to be asynchronously notified whenever a given metadata becomes available; (iii) to use ontologies to represent information in order to avoid ambiguous interpretation. This work presents QoMonitor, a module for QoS and QoC metadata monitoring that meets the abovementioned requirement. The architecture and implementation of QoMonitor are discussed. To support asynchronous communication QoMonitor uses two protocols: JMS and Light-PubSubHubbub. In order to illustrate QoMonitor in the development of ubiquitous application it was integrated to OpenCOPI (Open COntext Platform Integration), a Middleware platform that integrates several context provision middleware. To validate QoMonitor we used two applications as proofof- concept: an oil and gas monitoring application and a healthcare application. This work also presents a validation of QoMonitor in terms of performance both in synchronous and asynchronous requests

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of middleware technology in various types of systems, in order to abstract low-level details related to the distribution of application logic, is increasingly common. Among several systems that can be benefited from using these components, we highlight the distributed systems, where it is necessary to allow communications between software components located on different physical machines. An important issue related to the communication between distributed components is the provision of mechanisms for managing the quality of service. This work presents a metamodel for modeling middlewares based on components in order to provide to an application the abstraction of a communication between components involved in a data stream, regardless their location. Another feature of the metamodel is the possibility of self-adaptation related to the communication mechanism, either by updating the values of its configuration parameters, or by its replacement by another mechanism, in case of the restrictions of quality of service specified are not being guaranteed. In this respect, it is planned the monitoring of the communication state (application of techniques like feedback control loop), analyzing performance metrics related. The paradigm of Model Driven Development was used to generate the implementation of a middleware that will serve as proof of concept of the metamodel, and the configuration and reconfiguration policies related to the dynamic adaptation processes. In this sense was defined the metamodel associated to the process of a communication configuration. The MDD application also corresponds to the definition of the following transformations: the architectural model of the middleware in Java code, and the configuration model to XML

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O rápido progresso obtido nas técnicas cirúrgicas e anestésicas nos últimos anos proporcionou extraordinário aumento das indicações de procedimentos invasivos. Por outro lado, com o envelhecimento da população, o período de recuperação pós-operatória passou a ser motivo de maior preocupação da equipe de saúde. Para tanto, novas técnicas de analgesia foram criadas e desenvolvidas e, dentre elas, destaca-se a Analgesia Controlada pelo Paciente (ACP). em nosso país, o Serviço de Dor Aguda (SEDA) da Disciplina de Terapia Antálgica e Cuidados Paliativos, do Departamento de Anestesiologia da Faculdade de Medicina de Botucatu - UNESP, utiliza há muitos anos esta técnica de analgesia. Com a finalidade de atestar a qualidade do serviço prestado, a pesquisa objetiva verificar a eficácia e segurança do método, assim como identificar e caracterizar a população atendida. MÉTODO: de modo retrospectivo, foram avaliados 679 pacientes tratados pelo SEDA, exclusivamente com o método de ACP, durante três anos. Os pacientes foram incluídos na análise aleatoriamente, sem restrições quanto à idade, ao sexo, ao tipo de cirurgia e considerando-se unicamente a possibilidade de indicação da ACP. Foram estudados os seguintes atributos: sexo, idade, tipo de cirurgia, intensidade da dor, dias de acompanhamento, analgésicos utilizados, vias de administração, ocorrência de efeitos colaterais e complicações da técnica. RESULTADOS: 3,96% dos pacientes submetidos a cirurgias e 1,64% dos internados no período observado foram acompanhados com técnica ACP. A cirurgia torácica foi a mais freqüentemente atendida, com 25% dos pacientes. A morfina foi o medicamento mais utilizado (54,2%), sendo a via peridural a preferencial (49,5%). A escala numérica verbal média foi de 0,8 (0-10). Os efeitos colaterais ocorreram em 22,4% dos doentes tratados. CONCLUSÕES: Os resultados foram considerados excelentes quanto à qualidade da analgesia, embora com ocorrência de efeitos colaterais indesejáveis, tendo havido boa aceitação da técnica de analgesia pelas clínicas atendidas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Internet atual vem sofrendo vários problemas em termos de escalabilidade, desempenho, mobilidade, etc., devido ao vertiginoso incremento no número de usuários e o surgimento de novos serviços com novas demandas, propiciando assim o nascimento da Internet do Futuro. Novas propostas sobre redes orientadas a conteúdo, como a arquitetura Entidade Titulo (ETArch), proveem novos serviços para este tipo de cenários, implementados sobre o paradigma de redes definidas por software. Contudo, o modelo de transporte do ETArch é equivalente ao modelo best-effort da Internet atual, e vem limitando a confiabilidade das suas comunicações. Neste trabalho, ETArch é redesenhado seguindo o paradigma do sobreaprovisionamento de recursos para conseguir uma alocação de recursos avançada integrada com OpenFlow. Como resultado, o framework SMART (Suporte de Sessões Móveis com Alta Demanda de Recursos de Transporte), permite que a rede defina semanticamente os requisitos qualitativos das sessões para assim gerenciar o controle de Qualidade de Serviço visando manter a melhor Qualidade de Experiência possível. A avaliação do planos de dados e de controle teve lugar na plataforma de testes na ilha do projeto OFELIA, mostrando o suporte de aplicações móveis multimídia com alta demanda de recursos de transporte com QoS e QoE garantidos através de um esquema de sinalização restrito em comparação com o ETArch legado

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Eventos considerados menores têm assumido papel fundamental na determinação da qualidade do serviço prestado na área da Anestesiologia. O objetivo do presente estudo foi avaliar as principais preocupações dos pacientes em relação ao período pós-anestésico e testar a hipótese de que os efeitos mais indesejados podem ser influenciados por características demográficas. MÉTODO: Um questionário foi respondido por 440 pacientes imediatamente antes da avaliação pré-anestésica. Foram listados os possíveis efeitos indesejáveis no período pós-operatório imediato, baseados em levantamento a partir de dados disponíveis na literatura e considerando o critério de frequência, mas não o de gravidade. Foram avaliados os dados demográficos e pesquisadas as nove preocupações mais frequentemente citadas. As informações coletadas a partir da análise dos questionários preenchidos pelos entrevistados foram relacionadas com seus dados antropométricos, socioeconômicos e educacionais, com o objetivo de avaliar a influência dessas variáveis no perfil das respostas. RESULTADOS: Entre os efeitos indesejados, o temor de acordar intubado foi o mais frequentemente citado como o mais importante, seguido de dor forte no local da cirurgia e acordar durante a cirurgia. A análise dos três efeitos mais indesejados em relação aos dados demográficos não evidenciou diferença estatística significativa, com exceção do item dor no local da cirurgia (menos citada entre pacientes do sexo masculino). CONCLUSÕES: As principais preocupações dos pacientes em relação ao período pós-anestésico são: acordar com um tubo na garganta, dor forte no local da cirurgia e a lembrança de estar acordado durante a cirurgia. A idade, o grau de escolaridade e a renda familiar não determinaram diferenças nas preocupações dos pacientes.