955 resultados para Dollar-gold standard
Resumo:
BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.
Resumo:
La tomodensitométrie (CT) est une technique d'imagerie dont l'intérêt n'a cessé de croître depuis son apparition dans le début des années 70. Dans le domaine médical, son utilisation est incontournable à tel point que ce système d'imagerie pourrait être amené à devenir victime de son succès si son impact au niveau de l'exposition de la population ne fait pas l'objet d'une attention particulière. Bien évidemment, l'augmentation du nombre d'examens CT a permis d'améliorer la prise en charge des patients ou a rendu certaines procédures moins invasives. Toutefois, pour assurer que le compromis risque - bénéfice soit toujours en faveur du patient, il est nécessaire d'éviter de délivrer des doses non utiles au diagnostic.¦Si cette action est importante chez l'adulte elle doit être une priorité lorsque les examens se font chez l'enfant, en particulier lorsque l'on suit des pathologies qui nécessitent plusieurs examens CT au cours de la vie du patient. En effet, les enfants et jeunes adultes sont plus radiosensibles. De plus, leur espérance de vie étant supérieure à celle de l'adulte, ils présentent un risque accru de développer un cancer radio-induit dont la phase de latence peut être supérieure à vingt ans. Partant du principe que chaque examen radiologique est justifié, il devient dès lors nécessaire d'optimiser les protocoles d'acquisitions pour s'assurer que le patient ne soit pas irradié inutilement. L'avancée technologique au niveau du CT est très rapide et depuis 2009, de nouvelles techniques de reconstructions d'images, dites itératives, ont été introduites afin de réduire la dose et améliorer la qualité d'image.¦Le présent travail a pour objectif de déterminer le potentiel des reconstructions itératives statistiques pour réduire au minimum les doses délivrées lors d'examens CT chez l'enfant et le jeune adulte tout en conservant une qualité d'image permettant le diagnostic, ceci afin de proposer des protocoles optimisés.¦L'optimisation d'un protocole d'examen CT nécessite de pouvoir évaluer la dose délivrée et la qualité d'image utile au diagnostic. Alors que la dose est estimée au moyen d'indices CT (CTDIV0| et DLP), ce travail a la particularité d'utiliser deux approches radicalement différentes pour évaluer la qualité d'image. La première approche dite « physique », se base sur le calcul de métriques physiques (SD, MTF, NPS, etc.) mesurées dans des conditions bien définies, le plus souvent sur fantômes. Bien que cette démarche soit limitée car elle n'intègre pas la perception des radiologues, elle permet de caractériser de manière rapide et simple certaines propriétés d'une image. La seconde approche, dite « clinique », est basée sur l'évaluation de structures anatomiques (critères diagnostiques) présentes sur les images de patients. Des radiologues, impliqués dans l'étape d'évaluation, doivent qualifier la qualité des structures d'un point de vue diagnostique en utilisant une échelle de notation simple. Cette approche, lourde à mettre en place, a l'avantage d'être proche du travail du radiologue et peut être considérée comme méthode de référence.¦Parmi les principaux résultats de ce travail, il a été montré que les algorithmes itératifs statistiques étudiés en clinique (ASIR?, VEO?) ont un important potentiel pour réduire la dose au CT (jusqu'à-90%). Cependant, par leur fonctionnement, ils modifient l'apparence de l'image en entraînant un changement de texture qui pourrait affecter la qualité du diagnostic. En comparant les résultats fournis par les approches « clinique » et « physique », il a été montré que ce changement de texture se traduit par une modification du spectre fréquentiel du bruit dont l'analyse permet d'anticiper ou d'éviter une perte diagnostique. Ce travail montre également que l'intégration de ces nouvelles techniques de reconstruction en clinique ne peut se faire de manière simple sur la base de protocoles utilisant des reconstructions classiques. Les conclusions de ce travail ainsi que les outils développés pourront également guider de futures études dans le domaine de la qualité d'image, comme par exemple, l'analyse de textures ou la modélisation d'observateurs pour le CT.¦-¦Computed tomography (CT) is an imaging technique in which interest has been growing since it first began to be used in the early 1970s. In the clinical environment, this imaging system has emerged as the gold standard modality because of its high sensitivity in producing accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase of the number of CT examinations performed has raised concerns about the potential negative effects of ionizing radiation on the population. To insure a benefit - risk that works in favor of a patient, it is important to balance image quality and dose in order to avoid unnecessary patient exposure.¦If this balance is important for adults, it should be an absolute priority for children undergoing CT examinations, especially for patients suffering from diseases requiring several follow-up examinations over the patient's lifetime. Indeed, children and young adults are more sensitive to ionizing radiation and have an extended life span in comparison to adults. For this population, the risk of developing cancer, whose latency period exceeds 20 years, is significantly higher than for adults. Assuming that each patient examination is justified, it then becomes a priority to optimize CT acquisition protocols in order to minimize the delivered dose to the patient. Over the past few years, CT advances have been developing at a rapid pace. Since 2009, new iterative image reconstruction techniques, called statistical iterative reconstructions, have been introduced in order to decrease patient exposure and improve image quality.¦The goal of the present work was to determine the potential of statistical iterative reconstructions to reduce dose as much as possible without compromising image quality and maintain diagnosis of children and young adult examinations.¦The optimization step requires the evaluation of the delivered dose and image quality useful to perform diagnosis. While the dose is estimated using CT indices (CTDIV0| and DLP), the particularity of this research was to use two radically different approaches to evaluate image quality. The first approach, called the "physical approach", computed physical metrics (SD, MTF, NPS, etc.) measured on phantoms in well-known conditions. Although this technique has some limitations because it does not take radiologist perspective into account, it enables the physical characterization of image properties in a simple and timely way. The second approach, called the "clinical approach", was based on the evaluation of anatomical structures (diagnostic criteria) present on patient images. Radiologists, involved in the assessment step, were asked to score image quality of structures for diagnostic purposes using a simple rating scale. This approach is relatively complicated to implement and also time-consuming. Nevertheless, it has the advantage of being very close to the practice of radiologists and is considered as a reference method.¦Primarily, this work revealed that the statistical iterative reconstructions studied in clinic (ASIR? and VECO have a strong potential to reduce CT dose (up to -90%). However, by their mechanisms, they lead to a modification of the image appearance with a change in image texture which may then effect the quality of the diagnosis. By comparing the results of the "clinical" and "physical" approach, it was showed that a change in texture is related to a modification of the noise spectrum bandwidth. The NPS analysis makes possible to anticipate or avoid a decrease in image quality. This project demonstrated that integrating these new statistical iterative reconstruction techniques can be complex and cannot be made on the basis of protocols using conventional reconstructions. The conclusions of this work and the image quality tools developed will be able to guide future studies in the field of image quality as texture analysis or model observers dedicated to CT.
Resumo:
Epidemiological studies have shown that obesity is associated with chronic kidney disease and end stage renal disease. These studies have used creatinine derived equations to estimate glomerular filtration rate (GFR) and have indexed GFR to body surface area (BSA). However, the use of equations using creatinine as a surrogate marker of glomerular filtration and the indexation of GFR for BSA can be questioned in the obese population. First, these equations lack precision when they are compared to gold standard GFR measurements such as inulin clearances; secondly, the indexation of GFR for 1.73 m(2) of BSA leads to a systematic underestimation of GFR compared to absolute GFR in obese patients who have BSA that usually exceed 1.73 m(2). Obesity is also associated with pathophysiological changes that can affect the pharmacokinetics of drugs. The effect of obesity on both renal function and drug pharmacokinetics raises the issue of correct drug dosage in obese individuals. This may be particularly relevant for drugs known to have a narrow therapeutic range or excreted by the kidney.
Resumo:
Cough is a very frequent symptom in children. Different reviews have tried to delineate the best approach to pediatric cough.1 Clinical evaluation remains the most important diagnostic initial step. Although the relations between cough and asthma are not straightforward,2 wheeze should be considered as a physical sign of increased resistance to air flow. Lung function testing is the gold standard for analyzing pulmonary resistance to air flow but has a limited practical value in young children. The clinical evaluation of the presence or absence of wheeze thus remains a primary clinical step in coughing children. Young children do not necessarily breathe deeply in and out when asked to. For years, the author has used a so-called "squeeze and wheeze" maneuver (SWM, see Methods section for definition) to elicit chest signs in young children. The basic idea is to increase expiratory flows in children who do not cooperate adequately during their lung sounds analysis. This study was realized to communicate the author's experience of a yet unreported physical sign and to study its prevalence in young children cared for in a general pediatrics practice.
Resumo:
OBJECTIVE: Esophageal temperature is the gold standard for in-the-field temperature monitoring in hypothermic victims with cardiac arrest. For practical reasons, some mountain rescue teams use homemade esophageal thermometers to measure esophageal temperature; these consist of nonmedical inside/outside temperature monitoring instruments that have been modified to allow for esophageal insertion. We planned a study to determine the accuracy of such thermometers. METHODS: Two of the same model of digital cabled indoor/outdoor thermometer were modified and tested in comparison with a reference thermometer. The thermometers were tested in a water bath at different temperatures between 10°C and 35.2°C. Three hundred measurements were taken with each thermometer. RESULTS: Our experimental study showed that both homemade thermometers provided a good correlation and a clinically acceptable agreement in comparison with the reference thermometer. Measurements were within 0.5°C in comparison with the reference thermometer 97.5% of the time. CONCLUSIONS: The homemade thermometers performed well in vitro, in comparison with a reference thermometer. However, because these devices in their original form are not designed for clinical use, their use should be restricted to situations when the use of a conventional esophageal thermometer is impossible.
Resumo:
Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.
Resumo:
Black-blood MR coronary vessel wall imaging may become a powerful tool for the quantitative and noninvasive assessment of atherosclerosis and positive arterial remodeling. Although dual-inversion recovery is currently the gold standard, optimal lumen-to-vessel wall contrast is sometimes difficult to obtain, and the time window available for imaging is limited due to competing requirements between blood signal nulling time and period of minimal myocardial motion. Further, atherosclerosis is a spatially heterogeneous disease, and imaging at multiple anatomic levels of the coronary circulation is mandatory. However, this requirement of enhanced volumetric coverage comes at the expense of scanning time. Phase-sensitive inversion recovery has shown to be very valuable for enhancing tissue-tissue contrast and for making inversion recovery imaging less sensitive to tissue signal nulling time. This work enables multislice black-blood coronary vessel wall imaging in a single breath hold by extending phase-sensitive inversion recovery to phase-sensitive dual-inversion recovery, by combining it with spiral imaging and yet relaxing constraints related to blood signal nulling time and period of minimal myocardial motion.
Resumo:
El objetivo del presente estudio es comparar la prueba de la tuberculina y los IGRAS (concretamente la prueba del Quantiferón) en pacientes candidatos a recibir tratamiento inmunodepresor. Se evalúan 139 pacientes y se obtienen un mayor número de resultados positivos para la prueba de la tuberculina. La conclusión inicial, por tanto, es que ésta es la prueba más sensible, teniendo en cuenta el sesgo provocado por la ausencia de una prueba “gold standard” en la detección de infección tuberculosa latente. No se pueden obviar sin embargo los casos en que resultados negativos de la prueba de la tuberculina que fueron positivos en la prueba del Quantiferón , por lo que se concluye que ambas pruebas son útiles y necesarias en la detección de la infección tuberculosa latente en pacientes candidatos a inmunodepresión.
Resumo:
Background Adherence to chronic therapy is a key determinant of patient health outcomes in chronic disease. However, only about 50 % of patients adhere to chronic therapy. One of the challenges in promoting adherence is having an accurate understanding of adherence rates and the factors that contribute to non-adherence. There are many measures available to assess patient medication adherence. Aim of the review This review aims to present the commonly used indirect methods available for measuring medication adherence in routine healthcare and research studies. Method A literature review on medication adherence measures in patient populations with chronic conditions taking chronic medications was conducted through Medline (2003-2013). A complementary manual search of references cited in the retrieved studies was performed in order to identify any additional studies. Results Of the 238 initial Medline search results, 57 full texts were retrieved. Forty-seven articles were included as a result of the manual search. Adherence measures identified were: self-report (reported in 50 publications), electronic measures (33), pharmacy refills and claims data (26) and pill counts (25). Patient self-report, electronic measures, pharmacy refill and claims data were the most commonly used measures of adherence in research, routine practice, epidemiological and intervention studies. These methods, and their strengths and limitations have been described in this paper. Conclusion A multitude of indirect measures of adherence exist in the literature, however, there is no "gold" standard for measuring adherence to medications. Triangulation of methods increases the validity and reliability of the adherence data collected. To strengthen the adherence data collected and allow for comparison of data, future research and practice interventions should use an internationally accepted, operational standardized definition of medication adherence and clearly describe the medication adherence methods used.
Resumo:
Background: Neuroblastoma is a paediatrictumour derived from the neural crest. Biochemical diagnosis and follow up rely on quantitation of urinary catecholamines (dopamine and noradrenaline) and their metabolites vanillylmandelic acid (VMA) and homovanillic acid (HVA) (gold-standard). When combined, these analyses have a sensitivity of 95%. However, they are clearly limited by inaccuracy of urine collection in young children and normalisation of catecholamine concentrations by creatininuria. Recent development in biochemical diagnosis of pheochromocytoma, another neural crest tumour found in adults, shows that plasmatic measurement of methoxylated catecholamines called metanephrines are more sensitive and specific than other biomarkers. Moreover, a study to determine the reference intervals for metanephrines in a pediatric population has recently been completed. The aim of this work is to describe the role of metanephrines monitoring in the follow up of neuroblastoma. Method: This retrospective study included patients with neuroblastoma in whom the following parameters were determined: plasma free and total metanephrines, plasma catecholamines, 24h urinary catecholamines and metanephrines in absolute value and corrected by creatinine, VMA and HVA at the diagnosis and during treatment at the University Hospital of Lausanne (Switzerland). Eleven patients aged between the first day of life and 7 years old were followed between 2005 and 2012. Clinical outcome and biochemical concentrations of the analytes were correlated. Results: At diagnosis, plasma free and total normetanephrines and methoxytyramine have a sensitivity of 100% compared to 85% for the actual gold standard. Metanephrine remain below the upper reference limit as expected since these tumours do not produce adrenaline. The relationship between biochemical markers and clinical outcome is illustrated graphically. Plasma or urinary normetanephrine and methoxytyramine correlate better with the history of the patient than VMA and HVA, as evaluated by ordinal logistic regression. Concentrations of analytes in urine show a better correlation with clinical events when the results are corrected by creatininuria. Conclusion: Normetanephrine and methoxytyramine reflect disease history in neuroblastoma patients and could play a significant role in the follow up of this type of tumour. Formal studies in a sufficient number of patients are needed to confirm this preliminary observation.
Resumo:
BACKGROUND: Temporal arteritis is a very serious form of vasculitis. Early treatment is essential to avoid blindness. Surgical biopsy of the temporal artery is the gold standard for the diagnosis, but facial nerve injuries may occur. OBJECTIVE: To describe a simple and safe procedure for temporal artery biopsy. METHODS: Case report. RESULTS: A 62-year-old-woman with presumed temporal arteritis was referred. Precise localization of temporal arteries and its branches was obtained with color duplex ultrasonography. Arterial wall thickening (halo sign) was observed in the affected arterial segments. A frontal branch was precisely localized and infiltrated with 1% lidocaine. About 1 cm was removed for histopathologic examination. Thirty minutes was required to perform this outpatient procedure. The diagnosis of temporal arteritis was confirmed, and the patient was rapidly and successfully treated with prednisone. CONCLUSIONS: Color duplex ultrasonography allows precise localization of temporal arteries and its branches. This echocardiography-guided surgical procedure is easy and safe. Most dermatologic surgeons can perform it.
Resumo:
Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-tion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine.Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses ofthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatabilityof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.
Resumo:
Malignant melanoma, the deadliest form of skin cancer, is characterized by a predominant mutation in the BRAF gene. Drugs that target tumours carrying this mutation have recently entered the clinic. Accordingly, patients are routinely screened for mutations in this gene to determine whether they can benefit from this type of treatment. The current gold standard for mutation screening uses real-time polymerase chain reaction and sequencing methods. Here we show that an assay based on microcantilever arrays can detect the mutation nanomechanically without amplification in total RNA samples isolated from melanoma cells. The assay is based on a BRAF-specific oligonucleotide probe. We detected mutant BRAF at a concentration of 500 pM in a 50-fold excess of the wild-type sequence. The method was able to distinguish melanoma cells carrying the mutation from wild-type cells using as little as 20 ng µl(-1) of RNA material, without prior PCR amplification and use of labels.
Resumo:
Résumé : Un nombre croissant de cas de malaria chez les voyageurs et migrants a été rapporté. Bien que l'analyse microscopique des frottis sanguins reste traditionnellement l'outil diagnostic de référence, sa fiabilité dépend considérablement de l'expertise de l'examinateur, pouvant elle-même faire défaut sous nos latitudes. Une PCR multiplex en temps réel a donc été développée en vue d'une standardisation du diagnostic. Un ensemble d'amorces génériques ciblant une région hautement conservée du gène d'ARN ribosomial 18S du genre Plasmodium a tout d'abord été conçu, dont le polymorphisme du produit d'amplification semblait suffisant pour créer quatre sondes spécifiques à l'espèce P. falciparum, P. malariae, P. vivax et P. ovale. Ces sondes utilisées en PCR en temps réel se sont révélées capables de détecter une seule copie de plasmide de P. falciparum, P. malariae, P. vivax et P. ovale spécifiquement. La même sensibilité a été obtenue avec une sonde de screening pouvant détecter les quatre espèces. Quatre-vingt-dix-sept échantillons de sang ont ensuite été testés, dont on a comparé la microscopie et la PCR en temps réel pour 66 (60 patients) d'entre eux. Ces deux méthodes ont montré une concordance globale de 86% pour la détection de plasmodia. Les résultats discordants ont été réévalués grâce à des données cliniques, une deuxième expertise microscopique et moléculaire (laboratoire de Genève et de l'Institut Suisse Tropical de Bâle), ainsi qu'à l'aide du séquençage. Cette nouvelle analyse s'est prononcé en faveur de la méthode moléculaire pour tous les neuf résultats discordants. Sur les 31 résultats positifs par les deux méthodes, la même réévaluation a pu donner raison 8 fois sur 9 à la PCR en temps réel sur le plan de l'identification de l'espèce plasmodiale. Les 31 autres échantillons ont été analysés pour le suivi de sept patients sous traitement antimalarique. Il a été observé une baisse rapide du nombre de parasites mesurée par la PCR en temps réel chez six des sept patients, baisse correspondant à la parasitémie déterminée microscopiquement. Ceci suggère ainsi le rôle potentiel de la PCR en temps réel dans le suivi thérapeutique des patients traités par antipaludéens. Abstract : There have been reports of increasing numbers of cases of malaria among migrants and travelers. Although microscopic examination of blood smears remains the "gold standard" in diagnosis, this method suffers from insufficient sensitivity and requires considerable expertise. To improve diagnosis, a multiplex real-time PCR was developed. One set of generic primers targeting a highly conserved region of the 18S rRNA gene of the genus Plasmodium was designed; the primer set was polymorphic enough internally to design four species-specific probes for P. falciparum, P. vivax, P. malarie, and P. ovale. Real-time PCR with species-specific probes detected one plasmid copy of P. falciparum, P. vivax, P. malariae, and P. ovale specifically. The same sensitivity was achieved for all species with real-time PCR with the 18S screening probe. Ninety-seven blood samples were investigated. For 66 of them (60 patients), microscopy and real-time PCR results were compared and had a crude agreement of 86% for the detection of plasmodia. Discordant results were reevaluated with clinical, molecular, and sequencing data to resolve them. All nine discordances between 18S screening PCR and microscopy were resolved in favor of the molecular method, as were eight of nine discordances at the species level for the species-specific PCR among the 31 samples positive by both methods. The other 31 blood samples were tested to monitor the antimalaria treatment in seven patients. The number of parasites measured by real-time PCR fell rapidly for six out of seven patients in parallel to parasitemia determined microscopically. This suggests a role of quantitative PCR for the monitoring of patients receiving antimalaria therapy.
Resumo:
BACKGROUND: The aim of this study was to assess whether virtual reality (VR) can discriminate between the skills of novices and intermediate-level laparoscopic surgical trainees (construct validity), and whether the simulator assessment correlates with an expert's evaluation of performance. METHODS: Three hundred and seven (307) participants of the 19th-22nd Davos International Gastrointestinal Surgery Workshops performed the clip-and-cut task on the Xitact LS 500 VR simulator (Xitact S.A., Morges, Switzerland). According to their previous experience in laparoscopic surgery, participants were assigned to the basic course (BC) or the intermediate course (IC). Objective performance parameters recorded by the simulator were compared to the standardized assessment by the course instructors during laparoscopic pelvitrainer and conventional surgery exercises. RESULTS: IC participants performed significantly better on the VR simulator than BC participants for the task completion time as well as the economy of movement of the right instrument, not the left instrument. Participants with maximum scores in the pelvitrainer cholecystectomy task performed the VR trial significantly faster, compared to those who scored less. In the conventional surgery task, a significant difference between those who scored the maximum and those who scored less was found not only for task completion time, but also for economy of movement of the right instrument. CONCLUSIONS: VR simulation provides a valid assessment of psychomotor skills and some basic aspects of spatial skills in laparoscopic surgery. Furthermore, VR allows discrimination between trainees with different levels of experience in laparoscopic surgery establishing construct validity for the Xitact LS 500 clip-and-cut task. Virtual reality may become the gold standard to assess and monitor surgical skills in laparoscopic surgery.