929 resultados para Diode Laser


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This study sought to assess if discoloration of tooth structures occurs after photodynamic therapy (PDT) and to determine the efficacy of a protocol to remove the photosensitizers. Background data: PDT has been used in root canal treatment to enhance cleaning and disinfection of the root canal system. PDT uses a low power laser in association with a dye as a photosensitizer. Photosensitizers can induce staining of the dental structures, resulting in an unaesthetic appearance. Methods: Forty teeth were randomly divided into four groups according to the photosensitizer used and pre-irradiation time: 0.01% methylene blue for 5 min (MB5); 0.01% methylene blue for 10 min (MB 10); 0.01% toluidine blue for 5 min (TB5); and 0.01% toluidine blue for 10 min (TB 10). Specimens were irradiated with a 660 nm diode laser with a 300 mu m diameter optical fiber, at 40 mW power setting for 3 min. Immediately after, the photosensitizers were removed with Endo-PTC cream +2.5% sodium hypochlorite (NaOCl). The shade was measured by a Vita Easyshade spectrophotometer based on the CIELAB color system (L*a*b* values) at three different experimental times: before PDT (T0), immediately after PDT (T1), and after removal of the photosensitizer (T2). Results: The results showed a decrease in the averages of the L*a*b* coordinate values after PDT (T1) in all the groups, when compared with the number at T0, with a significant statistical difference in group MB10. After photosensitizer removal (T2), all the values of the coordinates increased with significant statistical differences (p < 0.05) between T1 and T2 in L* and a*. Conclusions: It can be concluded that both methylene blue and toluidine blue dyes cause tooth discoloration, and that Endo-PTC cream associated with 2.5% NaOCl effectively remove these dyes, regardless of the pre-irradiation time used for PDT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Triacrylate resins are widely used to fabricate 3D microstructures, photonic crystals and optical devices. These resins can be doped with photosensitive materials like Disperse Red 1 (DR1), an Azo dye that changes its molecular configuration from trans to cis (photoisomerisation) with variations in their optical absorption spectrum when irradiated with ultraviolet or visible light. The reversibility of this process is thermally activated and occurs when the molecule remains at dark. In this work was prepared a 1:1 mixture of ethoxylated-6-trimethylolpropane (SR499) and tris-2-hydroxyethyl-isocyanurate (SR368) triacrylate resins, plus photoinitiator Lucirin TPOL, forming a UV curable polymeric matrix doped with DR1. Thin films were deposited onto glass slides by spin-coating technique. The films showed photochromic effect when illuminated with a low power diode laser (450 nm and 50mW/cm2). This effect is reversible after sample is left in dark. Thermochromic effect was evaluated by optical absorption measurements in the range of 40 to 140oC, heating the samples in-situ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The preparation of Tm3+/Yb3+/Ho3+ co-doped CeO2 prepared by the precipitation method using ammonium hydroxide as a precursor is presented. By X-ray diffraction the materials show the phase-type of fluorite structure and the crystallite sizes were calculated by the Scherrer's equation. No other phase was observed evincing that the rare earth ions were inserted into the fluorite phase as substitutional or interstitial dopants. The microstrain calculated by the Williamson-Hall method do not show significant changes in their values, indicating that the inclusion of rare earths does not causes structural changes in the CeO2 used as a host matrix. All material showed intense upconversion emission at red and green region under excitation with diode laser at 980 nm. The color of emission changes from green to red with increasing excitation power pump. The materials showed suitable photoluminescent properties for applications as a laser source, solar cells, and great emitter at 800 nm. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated color change, stability, and tooth sensitivity in patients submitted to different bleaching techniques. Material and methods: In this study, 48 patients were divided into five groups. A half-mouth design was conducted to compare two in-office bleaching bleaching techniques (with and without light activation): G1: 35% hydrogen peroxide (HP) (Lase Peroxide - DMC Equipments, Sao Carlos, SP, Brazil) + hybrid light (HL) (LED/Diode Laser, Whitening Lase II DMC Equipments, Sao Carlos, SP, Brazil); G2: 35% HP; G3: 38% HP (X-traBoost - Ultradent, South Jordan UT, USA) + HL; G4: 38% HP; and G5: 15% carbamide peroxide (CP) (Opalescence PF - Ultradent, South Jordan UT, USA). For G1 and G3, HP was applied on the enamel surface for 3 consecutive applications activated by HL. Each application included 3x3' HL activations with 1' between each interval; for G2 and G4, HP was applied 3x15' with 15' between intervals; and for G5, 15% CP was applied for 120'/10 days at home. A spectrophotometer was used to measure color change before the treatment and after 24 h, 1 week, 1, 6, 12, 18 and 24 months. A VAS questionnaire was used to evaluate tooth sensitivity before the treatment, immediately following treatment, 24 h after and finally 1 week after. Results: Statistical analysis did not reveal any significant differences between in-office bleaching with or without HL activation related to effectiveness; nevertheless the time required was less with HL. Statistical differences were observed between the result after 24 h, 1 week and 1, 6, 12, 18 and 24 months (integroup). Immediately, in-office bleaching increased tooth sensitivity. The groups activated with HL required less application time with gel. Conclusion: All techniques and bleaching agents used were effective and demonstrated similar behaviors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: This study evaluated the in vivo response of apical and periapical tissues of dogs' teeth with apical periodontitis after one-session endodontic treatment with and without antimicrobial photodynamic therapy (aPDT). Methods: Sixty root canals with experimentally induced apical periodontitis were instrumented and assigned to 4 groups receiving aPDT and root canal filling (RCF) or not: group aPDT+/RCF- (n = 20): aPDT (photosensitizer phenothiazine chloride at 10 mg/mL for 3 minutes and diode laser [2 = 660 nm, 60 mW/cm(2)] for 1 minute) and RCF in the same session; group aPDT+/RCF (n = 10); group aPDT /RCF+ (n = 20), and group aPDT /RCF (n = 10). Teeth were restored, and the animals were killed after 90 days. Sections from the maxillas and mandibles were stained with hematoxylin-eosin and Mallory trichrome and examined under light microscopy. Descriptive (ie, newly formed apical mineralized tissue, periapical inflammatory infiltrate, apical periodontal ligament thickness, and mineralized tissue resorption) and quantitative (ie, periapical lesion size and number of inflammatory cells) microscopic analysis was performed. Quantitative data were analyzed by the Kruskal-Wallis and Dunn tests (alpha =.05). Results: In the aPDT-treated groups, the periapical region was moderately/severely enlarged with no inflammatory cells, moderate neoangiogenesis and fibrogenesis, and the smallest periapical lesions. Conclusions: Although apical closure by mineralized tissue deposition was not achieved, the absence of inflammatory cells, moderate neoangiogenesis, and fibrogenesis in the periapical region in the groups treated with aPDT indicate that this can be a promising adjunct therapy to cleaning and shaping procedures in teeth with apical periodontitis undergoing one-session endodontic treatment. (J Endod 2012;38:360-366)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the disinfection of dentine using photodynamic therapy with methylene blue in different formulations. Thirty bovine teeth roots were autoclaved and incubated with a suspension of Enterococcus faecalis. The specimen were randomly divided into three groups: G1, the roots were filled with 10 mM methylene blue dissolved in water; G2, the roots were filled with 10 mM methylene blue dissolved in a mixture of glycerol: ethanol: water; G3, roots filled with 100 mM methylene blue dissolved in water. The groups were irradiated with a 660 nm diode laser with an output power of 100 mW for 4 min, energy density of 850 J/cm2 and after this procedure, the sensitizer was removed and microbial samples were collected from within the root canals. The samples were plated on mEnterococcus to count the colony-forming units (CFU/mL). The means were: Group 1=513×103, Group 2=1431×103 and Group 3=2.96×103. The statistical analysis detected higher disinfection achieved by G3 when compared with groups G1 and G2, and no significant difference between the groups G1 and G2 (P>0.05). The increase of the concentration of methylene blue dye achieved higher disinfection in photodynamic therapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Over the last few years, low-level light therapy (LLLT) has shown an incredible suitability for a wide range of applications for central nervous system (CNS) related diseases. In this therapeutic modality light dosimetry is extremely critical so the study of light propagation through the CNS organs is of great importance. To better understand how light intensity is delivered to the most relevant neural sites we evaluated optical transmission through slices of rat brain point by point. We experimented red (λ = 660 nm) and near infrared (λ = 808 nm) diode laser light analyzing the light penetration and distribution in the whole brain. A fresh Wistar rat (Rattus novergicus) brain was cut in sagittal slices and illuminated with a broad light beam. A high-resolution digital camera was employed to acquire data of transmitted light. Spatial profiles of the light transmitted through the sample were obtained from the images. Peaks and valleys in the profiles show sites where light was less or more attenuated. The peak intensities provide information about total attenuation and the peak widths are correlated to the scattering coefficient at that individual portion of the sample. The outcomes of this study provide remarkable information for LLLT dose-dependent studies involving CNS and highlight the importance of LLLT dosimetry in CNS organs for large range of applications in animal and human diseases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) is a treatment modality that has advanced rapidly in recent years. It causes tissue and vascular damage with the interaction of a photosensitizing agent (PS), light of a proper wavelength, and molecular oxygen. Evaluation of vessel damage usually relies on histopathology evaluation. Results are often qualitative or at best semi-quantitative based on a subjective system. The aim of this study was to evaluate, using CD31 immunohistochem- istry and image analysis software, the vascular damage after PDT in a well-established rodent model of chemically induced mammary tumor. Fourteen Sprague-Dawley rats received a single dose of 7,12-dimethylbenz(a)anthraxcene (80 mg/kg by gavage), treatment efficacy was evaluated by comparing the vascular density of tumors after treatment with Photogem® as a PS, intraperitoneally, followed by interstitial fiber optic lighting, from a diode laser, at 200 mW/cm and light dose of 100 J/cm directed against his tumor (7 animals), with a control group (6 animals, no PDT). The animals were euthanized 30 hours after the lighting and mammary tumors were removed and samples from each lesion were formalin-fixed. Immunostained blood vessels were quantified by Image Pro-Plus version 7.0. The control group had an average of 3368.6 ± 4027.1 pixels per picture and the treated group had an average of 779 ± 1242.6 pixels per area (P < 0.01), indicating that PDT caused a significant decrease in vascular density of mammary tumors. The combined immu- nohistochemistry using CD31, with selection of representative areas by a trained pathology, followed by quantification of staining using Image Pro-Plus version 7.0 system was a practical and robust methodology for vessel damage evalua- tion, which probably could be used to assess other antiangiogenic treatments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ZusammenfassungIm Rahmen der EU-Projekte POLSTAR (Polar StratosphericAerosol Experiment) und STREAM (Stratosphere TroposphereExperiment by Airborne Measurements) wurden flugzeuggetragene Spurengasmessungen in verschiedenen geografischen Breiten durchgeführt. Zwei Messkampagnen fanden im Januar (POLSTAR 97) und März (STREAM 97) 1997 über Kiruna (Schweden, 67°N, 20°O) statt, eine Kampagne wurde im Juli 1998 von Timmins (Kanada, 47°N, 81°W) aus durchgeführt (STREAM 98).CO und N2O wurden mittels TDLAS (Tunable Diode Laser Absorption Spectroscopy) nachgewiesen, CO2 wurde mit einem modifizierten kommerziellen Messgerät breitbandig gemessen. Zur Untersuchung von Mischungsvorgängen in der Tropopausenregion wurden Korrelationenzwischen CO, O3, N2O, CO2 und NOy herangezogen.Dabei konnte festgestellt werden, dass im Winter in der untersten Stratosphäre Mischung mit troposphärischen Luftmassen durch isentropen Transport im Bereich der Polarfront bis zu potentiellen Temperaturen von Theta=335K auftritt. Im Sommer lässt sich Mischung mit troposphärischen Luftmassen bis mindestens Theta=360K nachweisen, die effektiver als im Winter abläuft.Exemplarisch kann an einem Flug gezeigt werden, dassbis Theta=349K die Ausbildung der Mischungsschicht durchLuftmassenaustausch an der Polarfront verursacht wird, während oberhalb von Theta=349K Signaturen subtropischertroposphärischer Luftmassen gefunden werden.Der stratosphärische Hintergrund wird mitbestimmt durch photochemisch gealterte Luftmassen, die ihren Ursprung höchstwahrscheinlich in der Vortexregion des vorangegangenen Winters haben.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The spectroscopic investigation of the gas-phase molecules relevant for the chemistry of the atmosphere and of the interstellar medium has been performed. Two types of molecules have been studied, linear and symmetric top. Several experimental high-resolution techniques have been adopted, exploiting the spectrometers available in Bologna, Venezia, Brussels and Wuppertal: Fourier-Transform-Infrared Spectroscopy, Cavity-Ring-Down Spectroscopy, Cavity-Enhanced-Absorption Spectroscopy, Tunable-Diode-Laser Spectroscopy. Concerning linear molecules, the spectra of a number of isotopologues of acetylene, 12C2D2, H12C13CD, H13C12CD, 13C12CD2, of DCCF and monodeuterodiacetylene DC4H, have been studied, from 320 to 6800 cm-1. This interval covers bending, stretching, overtone and combination bands, the focus on specific ranges depending on the molecule. In particular, the analysis of the bending modes has been performed for 12C2D2 (450-2200 cm-1), 13C12CD2 (450-1700 cm-1), DCCF (320-850cm-1) and DC4H (450-1100 cm-1), of the stretching-bending system for 12C2D2 (450-5500 cm-1) and of the 2nu1 and combination bands up to four quanta of excitation for H12C13CD, H13C12CD and 13C12CD2 (6130-6800 cm-1). In case of symmetric top molecules, CH3CCH has been investigated in the 2nu1 region (6200-6700 cm-1), which is particularly congested due to the huge network of states affected by Coriolis and anharmonic interactions. The bending fundamentals of 15ND3 (450-2700 cm-1) have been studied for the first time, characterizing completely the bending states, v2 = 1 and v4 = 1, whereas the analysis of the stretching modes, which evidenced the presence of several perturbations, has been started. Finally, the fundamental band nu4 of CF3Br in the 1190-1220 cm-1 region has been investigated. Transitions belonging to the CF379Br and CF381Br molecules have been identified since the spectra were recorded using a sample containing the two isotopologues in natural abundance. This allowed the characterization of the v4 = 1 state for both isotopologues and the evaluation of the bromine isotopic splitting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In dieser Arbeit wird die Erweiterung und Optimierung eines Diodenlasersystems zur hochauflösenden Resonanzionisationsmassenspektrometrie beschrieben. Ein doppelinterferometrisches Frequenzkontrollsystem, welches Absolutstabilisierung auf ca. 1 MHz sowie sekundenschnelle Frequenzverstimmungen um mehrere GHz für bis zu drei Laser parallel ermöglicht, wurde optimiert. Dieses Lasersystem dient zwei wesentlichen Anwendungen. Ein Aspekt waren umfangreiche spektroskopische Untersuchungen an Uranisotopen mit dem Ziel der präzisen und eindeutigen Bestimmung von Energielagen, Gesamtdrehimpulsen, Hyperfeinkonstanten und Isotopieverschiebungen sowie die Entwicklung eines effizienten, mit kommerziellen Diodenlasern betreibbaren Anregungsschemas. Mit diesen Erkenntnissen wurde die Leistungsfähigkeit des Lasermassenspektrometers für die Ultraspurenanalyse des Isotops 236U, welches als Neutronendosimeter und Tracer für radioaktive anthropogene Kontaminationen in der Umwelt verwendet wird, optimiert und charakterisiert. Anhand von synthetischen Proben wurde eine Isotopenselektivität von 236U/238U=4,5(1,5)∙10-9 demonstriert.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The vibrational excitation of CO2 by a fast-moving O atom followed by infrared emission from the vibrationally excited CO2 has been shown to be an important cooling mechanism in the upper atmospheresof Venus, Earth and Mars. We are trying to determine more precisely the efficiency (rate coefficient) of the CO2-O vibrational energy transfer. For experimental ease the reverse reaction is used, i.e. collision of a vibrationally excited CO2 with atomic O, where we are able to convert to the atmospherically relevant reaction via a known equilibrium constant. The goal of this experiment was to measure the magnitudes of rate coefficients for vibrational energy states above the first excited state, a bending mode in CO2. An isotope of CO2, 13CO2, was used for experimental ease. The rate coefficients for given vibrational energy transfers in 13CO2 are not significantly different from 12CO2 at this level of precision. A slow-flowing gas mixture was flowed through a reaction cell: 13CO2 (vibrational specie of interest), O3(atomic O source), and Ar (bath gas). Transient diode laser absorption spectroscopy was used to monitor thechanging absorption of certain vibrational modes of 13CO2 after a UV pulse from a Nd:YAG laser was fired. Ozone absorbed the UV pulse in a process which vibrationally excited 13CO2 and liberated atomic O.Transient absorption signals were obtained by tuning the diode laser frequency to an appropriate ν3 transition and monitoring the population as a function of time following the Nd:YAG pulse. Transient absorption curves were obtained for various O atom concentrations to determine the rate coefficient of interest. Therotational states of the transitions used for detection were difficult to identify, though their short reequilibration timescale made the identification irrelevant for vibrational energy transfer measurements. The rate coefficient for quenching of the (1000) state was found to be (4 ± 8) x 10-12 cm3 s-1 which is the same order of magnitude as the lowest-energy bend-excited mode: (1.8 ± 0.3) x 10-12 cm3 s-1. More data is necessary before it can be certain that the numerical difference between the two is real.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.