980 resultados para DOUBLE CROSSOVER RECOMBINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the effects of cannabis on perception are well documented, little is known about their neural basis or how these may contribute to the formation of psychotic symptoms. We used functional magnetic resonance imaging (fMRI) to assess the effects of Delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) during visual and auditory processing in healthy volunteers. In total, 14 healthy volunteers were scanned on three occasions. Identical 10mg THC, 600mg CBD, and placebo capsules were allocated in a balanced double-blinded pseudo-randomized crossover design. Plasma levels of each substance, physiological parameters, and measures of psychopathology were taken at baseline and at regular intervals following ingestion of substances. Volunteers listened passively to words read and viewed a radial visual checkerboard in alternating blocks during fMRI scanning. Administration of THC was associated with increases in anxiety, intoxication, and positive psychotic symptoms, whereas CBD had no significant symptomatic effects. THC decreased activation relative to placebo in bilateral temporal cortices during auditory processing, and increased and decreased activation in different visual areas during visual processing. CBD was associated with activation in right temporal cortex during auditory processing, and when contrasted, THC and CBD had opposite effects in the right posterior superior temporal gyrus, the right-sided homolog to Wernicke`s area. Moreover, the attenuation of activation in this area (maximum 61, -15, -2) by THC during auditory processing was correlated with its acute effect on psychotic symptoms. Single doses of THC and CBD differently modulate brain function in areas that process auditory and visual stimuli and relate to induced psychotic symptoms. Neuropsychopharmacology (2011) 36, 1340-1348; doi:10.1038/npp.2011.17; published online 16 March 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The use of Onyx in the treatment of intracranial AVMs has increased the cure rate of endovascular embolization compared with the use of liquid adhesive agents. Inadvertent occlusion of the draining veins before the complete exclusion of the nidus constitutes a major risk of bleeding. We report a case series using the technique of double simultaneous arterial catheterization as an approach to achieve the complete, exclusion of the nidus before reaching the venous drainage, through a more controlled hemodynamic filling. MATERIALS AND METHODS: Between April 2008 and November 2009, 17 patients with brain AVMs were treated by the DACT. The mean age of the patients was 32.7 years (range, 6-54 years), with 9 females and 8 males. The clinical onset was characterized by intracranial hemorrhage in 8 patients and by seizures in 7. The size of the AVMs ranged from 13 to 54 mm (average, 26.2 mm). The DACT was always used with the objective of curing the AVM. RESULTS: All 17 patients completed the EVT. The average number of sessions conducted was 1.4 (range, 1-3 sessions), with the average injection amount of 6.9 mL of Onyx (range, 2-25.2 mL). Sixteen AVMs (94.1%) were angiographically cured by embolization. Clinical complications occurred in 2 patients (11.7%); 1 of these was permanent (5.9%). No deaths were registered. CONCLUSIONS: This preliminary series shows that the DACT presents satisfactory results when used with curative intent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated a novel presynchronization method, using Ovsynch prior to the Ovsynch-timed AI protocol (Double-Ovsynch) compared to Presynch-Ovsynch. Lactating Holstein (n = 337) cows, were assigned to two treatment groups: (1) Presynch (n = 180), two injections of PGF 14 d apart, followed by the Ovsynch-timed AI protocol 12 d later; (2) Double-Ovsynch (n = 157), received GnRH, PGF 7 d later, and GnRH 3 d later, followed by the Ovsynch-timed AI protocol 7 d later. All cows received the same Ovsynch-timed AI protocol: GnRH (G1) at 68 +/- 3 DIM (mean +/- SEM), PGF 7 d later, GnRH (G2) 56 h after PGF, and AI 16 to 20 h later. Pregnancy was diagnosed 39-45 d after timed AI. Double-Ovsynch increased the pregnancies per AI (P/AI) compared to Presynch-Ovsynch (49.7% vs 41.7%, P = 0.03). Surprisingly, Double-Ovsynch increased P/AI only in primiparous (65.2% vs 45.2%; P = 0.02) and not multiparous (37.5% vs 39.3%) cows. In a subset of 87 cows, ovarian ultrasonography and progesterone (P4) measurements were performed at G1 and 7 d later. Double-Ovsynch decreased the percentage of cows with low P4 (<1 ng/mL) at G1 (9.4% vs 33.3%) and increased the percentage of cows with high P4 (>= 3 ng/mL) at PGF (78.1% vs 52.3%). Thus, presynchronization of cows with Double-Ovsynch increased fertility in primiparous cows compared to a standard Presynch protocol, perhaps due to induction of ovulation in non-cycling cows and improved synchronization of cycling cows. Future studies are needed, with a larger number of cows, to further test the hypothesis of higher fertility with Double-Ovsynch, and to elucidate the physiological mechanisms that underlie apparent changes in fertility with this protocol. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The burning mouth syndrome (BMS) is a chronic condition characterized by oral burning pain in the absence of clinical abnormalities and without established therapy. The purpose of this study was to evaluate the effectiveness of alpha lipoic acid (ALA) in the management of BMS symptoms through a randomized double-blind placebo-controlled trial. Thirty-eight patients (34 women and four men, median age 62.9 years, range 36-78) were included and 31 completed the study. The patients were randomized into two cycles of treatment: one with alpha lipoic acid and one with placebo both administered in identical capsules. These cycles were separated by a washout period of 20 days. The oral symptoms and the treatment response were assessed using a 100-mm visual analog scale before and after each cycle and the global perceived effect score, using a 5-point scale after each treatment cycle. The level of reduction on burning was significant for both treatments (paired t-test: P < 0.05; rp = 0.011; ral < 0.001). Considering the two cycles together, 22 patients reported at least some improvement after ALA use and 23 patients after placebo. Comparison of the oral assessment scores of the two cycles failed to demonstrate the effectiveness of ALA over placebo (t-test: P > 0.05; r = 0.75).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have indicated that the use of low-fluoride dentifrices could lead to proportionally higher plaque fluoride levels when compared with conventional dentifrices. This double-blind, randomized, crossover study determined the effects of placebo, low-fluoride, and conventional dentifrices on plaque fluoride concentrations ([F]) in children living in communities with 0.04, 0.72, and 3.36 ppm F in the drinking water. Children used the toothpastes twice daily, for 1 wk. Samples were collected 1 and 12 hrs after the last use of dentifrices and were analyzed for fluoride and calcium. Similar increases were found 1 hr after the children brushed with low-fluoride (ca. 1.9 mmol F/kg) and conventional (ca. 2.4 mmol F/kg) dentifrices in the 0.04- and 0.72-ppm-F communities. Despite the fact that the increases were less pronounced in the 3.36-ppm-F community, our results indicate that the use of a low-fluoride dentifrice promotes a proportionally higher increase in plaque [F] when compared with that achieved with a conventional dentifrice, based on dose-response considerations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in situ/ex vivo study assessed the effect of different concentrations of fluoride in dentifrices on dentin subjected to erosion or to erosion plus abrasion. Ten volunteers took part in this crossover and double-blind study performed in 3 phases (7 days). They wore acrylic palatal appliances containing 4 bovine dentin blocks divided in two rows: erosion and erosion plus abrasion. The blocks were subjected to erosion by immersion ex vivo in a cola drink (60 s, pH 2.6) 4 times daily. During this step, the volunteers brushed their teeth with one of three dentifrices D (5,000 ppm F, NaF, silica); C (1,100 ppm F, NaF, silica) and placebo (22 ppm F, silica). Then, the respective dentifrice slurry (1: 3) was dripped on dentin surfaces. While no further treatment was performed in one row, the other row was brushed using an electric toothbrush for 30 s ex vivo. The appliances were replaced in the mouth and the volunteers rinsed with water. Dentin loss was determined by profilometry and analyzed by 2-way ANOVA/Bonferroni test (alpha = 0.05). Dentin loss after erosive-abrasive wear was significantly greater than after erosion alone. Wear was significantly higher for the placebo than for the D and C dentifrices, which were not significantly different from each other. It can be concluded that the presence of fluoride concentrations around 1,100 ppm in dentifrices is important to reduce dentin wear by erosion and erosion + abrasion, but the protective effect does not increase with fluoride concentration. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this double-blind and randomized controlled trial, we analyzed whether a lower concentration of chlorhexidine in dentifrices could reduce the risk of tooth staining without compromising its effectiveness in controlling gingivitis, bleeding, and dental plaque. Methods: Volunteers with fixed orthodontic appliances were randomly divided into 3 groups: control, 1100 ppm F, NaF (n = 27); experimental, chlorhexidine 0.50% (n = 27); and experimental, chlorhexidine 0.75% (n = 27). At baseline, and after 6 and 12 weeks, clinical examinations were carried out. Staining, calculus, gingivitis, bleeding, and dental plaque data were analyzed with Friedman tests to evaluate intragroup changes over time. To detect intergroup differences after 12 months, the data were evaluated with Kruskal-Wallis tests. Dunn tests were used in both situations for necessary post-hoc analyses. Results: The groups were statistically similar for the stain, calculus, and plaque indexes, but there were statistically significant differences for the gingival and bleeding indexes. During the experimental periods, gingivitis and bleeding scores improved in all 3 groups. Only the 0.75% chlorhexidine dentifrice significantly increased the stain index, although most patients did not notice the stains. The intergroup comparison showed a statistically significant better performance of the experimental groups regarding the gingival and bleeding indexes. Conclusions: This study suggests that the use of dentifrices with lower concentration of chlorhexidine can reduce the risk of tooth staining without compromising its effectiveness in controlling gingivitis and bleeding in orthodontic patients. (Am J Orthod Dentofacial Orthop 2009; 136: 651-6)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Researchers have proposed the use of fluoride for the prevention of enamel wear; however, only limited information is available about the impact of fluoridated dentifrices. Because tooth wear is a well-recognized dental problem, the authors conducted an in situ, ex vivo study to assess the efficacy of a highly concentrated fluoride dentifrice on bovine enamel subjected to erosion and abrasion. Methods. The authors conducted a double-blind, crossover in situ study consisting of three phases (seven days each). In each phase, the authors tested one of the dentifrices (5,000 parts per million fluoride [F]; 1,100 ppm F; no F). They performed erosive challenges with the use of cola drink (60 seconds, four times per day) and abrasive challenges via toothbrushing (30 seconds, four times per day). The authors determined the enamel loss via profilometry. Results. The authors tested the data by using two-way analysis of variance (P <.05). For the erosion-plus-abrasion condition, the study results showed that enamel wear was significantly higher than that with erosion alone. The findings showed no significant differences between the dentifrices regarding enamel wear. Conclusions. Within the in situ, ex vivo conditions of this study, the authors concluded that the highly concentrated fluoride dentifrice did not have a protective effect on enamel against erosion and erosion plus toothbrushing abrasion. Clinical Implications. Patients at risk of developing enamel erosion should benefit from preventive measures other than fluoride dentifrice, because even a highly concentrated fluoride dentifrice does not appear to prevent enamel erosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study compared the clinical efficacy of 4% articaine (A200) and 0.5% bupivacaine (B200), both with 1: 200,000 epinephrine, for lower third molar removal. Study design: Fifty patients underwent removal of symmetrically positioned lower third molars, in 2 separate appointments, under local anesthesia either with A200 or B200, in a double-blind, randomized, and crossover manner. Time to onset, duration of postoperative analgesia, duration of anesthetic action on soft tissues, intraoperative bleeding, and hemodynamic parameters were evaluated. Results: A statistically significant difference between the time to onset of A200 (1.66 +/- 0.13 minutes) and B200 (2.51 +/- 0.21 minutes) was found (P < .05). There was no statistically significant difference in the duration of analgesia, whether the patient was subjected to osteotomy or not, regardless of the local anesthetic used (3 to 4 hours; P < .05). However, when patients received B200 they experienced a statistically significant longer period of anesthesia on the soft tissues as compared with when they had received A200 (around 5 hours and 4 hours, respectively, P < .05). The surgeon`s rating of intraoperative bleeding was considered very close to minimal for both anesthetics. In the surgeries with osteotomy, the comparison between A200 and B200 showed statistically significant differences in the diastolic (64 mm Hg and 68 mm Hg, respectively, P = .001) and mean arterial pressure (86 mm Hg and 89 mm Hg, respectively, P = .031) when data from all the surgical phases were pooled. Additionally, the mouth opening at the suture removal was statistically different for A200 and B200 solutions (91.90% +/- 3.00% and 88.57% +/- 2.38% of the preoperative measure, respectively) when surgeries required bone removal (P < .05). Conclusions: In comparison with 0.5% bupivacaine, 4% articaine (both with 1: 200,000 epinephrine) provided a shorter time to onset and comparable hemostasis and postoperative pain control with a shorter duration of soft tissue anesthesia in lower third molar removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of diode laser (GaAlAs - 780 nm) on pain to palpation and electromyographic (EMG) activity of the masseter and anterior temporalis muscles. The laser was applied on the temporalis and masseter muscles twice a week (four weeks). Forty-eight (48) patients with myofascial pain were randomly assigned between actual and placebo treatments and between the energetic doses of 25 J/cm(2) and 60 J/cm(2), and were evaluated using VAS before, immediately after the final application, and 30 days after the laser treatment. Surface electromyography was performed with maximum dental clenching before and after laser therapy. The results show there were no significant statistical differences in the EMG activity between the groups before and after laser treatment. With regard to the pain at palpation, although both groups presented a significant difference in the symptoms before and after the treatment, only the active doses showed statistically significant reductions in pain level in all the regions of the palpated muscles. However, there was no significant statistical difference between groups (experimental and placebo). In conclusion, low level laser did not promote any changes in EMG activity. The treatment did, however, lessen the pain symptoms in the experimental groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the analgesic effect of Low Intensity Laser Therapy (LILT) and its influence on masticatory efficiency in patients with temporomandibular dysfunction (TMD). This study was performed using a random, placebo-controlled, and double-blind research design. Fourteen patients were selected and divided into two groups (active and placebo). Infrared laser (780 nm, 70 mw, 60s, 105J/cm(2)) was applied precisely and continuously into five points of the temporomandibular joint (TMJ) area: lateral point (LP), superior point (SP), anterior point (AP), posterior point (PP), and posterior-inferior point (PIP) of the condylar position. This was performed twice per week, for a total of eight sessions, To ensure a double-blind study, two identical probes supplied by the manufacturer were used: one for the active laser and one for the inactive placebo laser. They were marked with different letters (A and B) by a clinician who did not perform the applications. A Visual Analogue Scale (VAS) and a colorimetric capsule method were employed. Data were obtained three times: before treatment (Ev1), shortly after the eighth session (Ev2), and 30 days after the first application (Ev3). Statistical tests revealed significant differences at one percent (1%) likelihood, which implies that superiority of the active group offered considerable TMJ pain improvement. Both groups presented similar masticatory behavior, and no statistical differences were found. With regard to the evaluation session, Ev2 presented the lowest symptoms and highest masticatory efficiency throughout therapy. Therefore, low intensity laser application is effective in reducing TMD symptoms, and has influence over masticatory efficiency [Ev2 (0.2423) and Ev3 (0.2043), observed in the interaction Evaluations x Probes for effective dosage].