988 resultados para DETECTOR DE EVENTOS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente proyecto de investigación se presenta como trabajo final del Máster en Estudis Avançats en Comunicació Social. El objetivo de este proyecto es sentar las bases de la futura tesis doctoral, planteando una investigación cuyo objetivo es determinar la efectividad que tienen los eventos para transmitir mensajes de una organización hacia sus públicos, con miras a que este mensaje sea aprendido y aplicado, para así lograr los fines definitivos queproyecta lograr la organización. La investigación en primer término busca aclarar conceptos sobre lo que envuelve al evento, para después mediante un estudio de caso aplicar una metodología cuantitativa y cualitativa, que ayude a develar la efectividad que guardan los eventos del objeto de estudio en relación a los objetivos para los que fueron diseñados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo de fin de carrera se centra en el desarrollo de una aplicación web basándose en el contexto del área temática PHP comunicado con MySQL. El objetivo de la aplicación es crear, gestionar y organizar eventos de una forma más fácil y rápida a través de internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CERNin tutkimuskeskuksen rakenteilla olevan hadronikiihdyttimen eräs tarkoitus on todistaa Higgsin bosonin olemassaolo. Higgsin bosonin löytyminen yhtenäistäisi nykyisen hiukkasfysiikan teorian ja antaisi selityksen sille kuinka hiukkaset saavat massansa. Kiihdyttimen CMS koeasema on tarkoitettu erityisesti myonien ilmaisuun. Tämä työ liittyy CMS koeaseman RPC-ilmaisintyypin linkkijärjestelmään, jonka tarkoituksena on käsitellä ilmaisimelta tulevia myonien aiheuttamia signaaleja ja lähettää tiedot tärkeäksi katsotuista törmäystapahtumista tallennettavaksi analysointia varten. Työssä on toteutettu linkkijärjestelmän ohjaus- ja linkkikorteille testiympäristö, jolla voidaan todeta järjestelmän eri osien keskinäinen yhteensopivuus ja toimivuus. Työn alkuosassa esitellään ilmaisimen linkkijärjestelmän eri osat ja niiden merkitykset. Työn loppuosassa käydään läpi eri testimenetelmiä ja analysoidaan niiden antamia tuloksia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Euroopan hiukkastutkimuslaitoksen CERNin rakenteilla olevan LHC-hiukkaskiihdyttimen CMS-koeasema on tarkoitettu erityisesti myonin ilmaisuun. Tässä työssä on esitelty CMS-koeaseman RPC-ilmaisintyypin linkkijärjestelmä ja sen testaamiseen tarkoitetut laitteet sekä laitteiden testaamiseen tarvittavat ohjelmistot. Työssä on selvitetty ohjelmien toimivuus ja keskinäinen yhteensopivuus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El impacto de los Eventos Adversos (EA) durante la asistencia sanitaria es un problema de salud pública de gran actualidad y muy presente a nivel mundial, provocando tres veces más muertes que los accidentes de tráfico. Afecta a todos los niveles sanitarios y perturba de forma relevante la seguridad del paciente. Los objetivos de este trabajo son: conocer la prevalencia de los EA en las unidades asistenciales españolas, comparar el impacto de estos a nivel nacional e internacional, y conocer la forma de notificación así como las estrategias de mejora de los mismos. Para ello, se llevará a cabo una revisión de la literatura bibliográfica en la que se recogerán y se analizaran artículos de carácter científico publicados en revistas indexadas en las bases de datos más consultadas. Se utilizaran artículos escritos tanto en castellano como en inglés, vinculados al área de conocimiento y de interés para esta revisión. Finalmente se han incluido 50 referencias bibliográficas. Así encontramos que los EA en los servicios de hospitalización del ámbito internacional tienen una incidencia máxima de 16.6%, y un 10.11% en España, que aumenta hasta el 25% cuando se trata de unidades especiales. El 4% producen la muerte del paciente. Más del 80% son evitables y el 95% no se notifican. Enfermería es responsable del 33% de EA producidos. Como conclusiones destaca la inexistencia de un mecanismo de prevención eficaz para menguar el impacto de los EA, pese a su gran incidencia. El miedo a represalia y la falta de consciencia de producción del EA por parte de los profesionales de la salud, hacen que se produzca una gran infra-notificación de estos, lo cual dificulta el cumplimiento de las medidas de prevención. Se debe extender la preocupación por el impacto de los EA al ámbito social, sin limitarse solamente al sanitario. Para ello, es necesario concienciar a los profesionales de la salud en primer lugar, trasladándose así a la sociedad en general, con el objetivo de disminuir el impacto en la salud pública de la llamada “Epidemia Oculta de los Errores Sanitarios”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we explore the use of non-linear transformations in order to improve the performance of an entropy based voice activity detector (VAD). The idea of using a non-linear transformation comes from some previous work done in speech linear prediction (LPC) field based in source separation techniques, where the score function was added into the classical equations in order to take into account the real distribution of the signal. We explore the possibility of estimating the entropy of frames after calculating its score function, instead of using original frames. We observe that if signal is clean, estimated entropy is essentially the same; but if signal is noisy transformed frames (with score function) are able to give different entropy if the frame is voiced against unvoiced ones. Experimental results show that this fact permits to detect voice activity under high noise, where simple entropy method fails.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Este trabalho foi realizado com o objetivo de caracterizar o detector de diamante, bem como observar seu comportamento. MATERIAIS E MÉTODOS: As características dosimétricas de feixes de fótons de 6 MV de energia foram medidas utilizando o sistema automático de varredura MP3 da PTW com um detector de diamante e foram comparadas com medidas usando uma câmara de ionização 31010 da PTW. RESULTADOS: As características dosimétricas do detector de diamante foram observadas por meio de medidas de linearidade com a dose, dependência com a taxa de dose e distribuições de dose em profundidade, bem como perfis. CONCLUSÃO: Algumas medidas com diamante e câmara de ionização foram validadas com resultados publicados na literatura, o que demonstrou um bom comportamento do detector de diamante na comparação com a câmara de ionização, muito utilizada para dosimetria em radioterapia, evidenciando que o diamante é uma boa escolha de detector para dosimetria de campos pequenos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large hadron collider constructed at the European organization for nuclear research, CERN, is the world’s largest single measuring instrument ever built, and also currently the most powerful particle accelerator that exists. The large hadron collider includes six different experiment stations, one of which is called the compact muon solenoid, or the CMS. The main purpose of the CMS is to track and study residue particles from proton-proton collisions. The primary detectors utilized in the CMS are resistive plate chambers (RPCs). To obtain data from these detectors, a link system has been designed. The main idea of the link system is to receive data from the detector front-end electronics in parallel form, and to transmit it onwards in serial form, via an optical fiber. The system is mostly ready and in place. However, a problem has occurred with innermost RPC detectors, located in sector labeled RE1/1; transmission lines for parallel data suffer from signal integrity issues over long distances. As a solution to this, a new version of the link system has been devised, a one that fits in smaller space and can be located within the CMS, closer to the detectors. This RE1/1 link system has been so far completed only partially, with just the mechanical design and casing being done. In this thesis, link system electronics for RE1/1 sector has been designed, by modifying the existing link system concept to better meet the requirements of the RE1/1 sector. In addition to completion of the prototype of the RE1/1 link system electronics, some testing for the system has also been done, to ensure functionality of the design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Master’s Thesis work reports about electric field distribution in recently developed silicon edgeless detector with a new current terminating structure. This structure enables the essential reduction of insensitive detector area as well as allows separation of the current flowing through the active area from the current flowing at the cut edge. The reliable operation of this detector is strongly needed due to the installation inside LHC. In accordance with formulated problems SEM was used as an investigation tool for collecting the data about electric field distribution.