1000 resultados para Current Commutating Mixer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current research began from the starting point that what we are grappling with when we are dealing with violent extremists by and large is essentially ‘normal people’. What follows in this third major section of this research paper is the theoretical and conceptual search for making researchable the following question: ‘How do you assess someone who is normal?’

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production mechanism of OH radicals in a pulsed DC plasma jet is studied by a two-dimensional (2-D) plasma jet model and a one-dimensional (1-D) discharge model. For the plasma jet in the open air, electron-impact dissociation of H2O, electron neutralization of H2O+, as well as dissociation of H2O by O(1D) are found to be the main reactions to generate the OH species. The contribution of the dissociation of H2O by electron is more than the others. The additions of N2, O2, air, and H2O into the working gas increase the OH density outside the tube slightly, which is attributed to more electrons produced by Penning ionization. On the other hand, the additions of O2 and H2O into the working gas increase the OH density inside the tube substantially, which is attributed to the increased O (1D) and H2O concentration, respectively. The gas flow will transport high density OH out of the tube during pulse off period. It is also shown that the plasma chemistry and reactivity can be effectively controlled by the pulse numbers. These results are supported by the laser induced fluorescence measurements and are relevant to several applications of atmospheric-pressure plasmas in health care, medicine, and materials processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Many preterm neonates display difficulty establishing suck-feeding competence in the weeks following birth. Ineffective management of transitional feeding issues may cause patient complications, and can contribute to increased length of stay. Aims: Given that many neonatal nurseries appear to vary in their neonatal feeding management practices, the aim of this study was to investigate and document the routine level of support and intervention currently provided for preterm neonates with transitional feeding issues across the various level II (special care) nurseries (SCNs) in Queensland, Australia. Methods: A questionnaire was mailed to all Queensland SCNs in 2005 (n = 36). The questionnaire contained a series of closed-choice and short-answer questions designed to obtain information from each SCN regarding their current practices for managing transitional feeding issues in preterm neonates. Results were confirmed during a follow-up phone call. Results: Responses were obtained from 29 SCNs (80.6%). None of these nurseries reported having any formal, written policies regarding the management of transitional feeding issues in preterm neonates. Wide variations were reported in relation to the suck-feeding assessments and interventions used by staff within the various SCNs. Of the 29 nurseries, 4 (13.8%) reported using checklists or assessments to judge readiness for suck-feeds, and 5 (17.2%) reported using pulse oximetry to judge tolerance of suck-feeding attempts. Eighteen SCNs (62.1%) reported offering some form of active intervention to assist neonates with transitional feeding issues, with the most common intervention techniques reported being non-nutritive sucking during tube feeds, pre-feeding oral stimulation, and actively pacing suck-feeds. Twenty-two SCNs (75.4%) reported having access to a lactation consultant to assist mothers with breastfeeding issues. Conclusions: Differences were reported in the routine management of transitional feeding issues in preterm neonates across the various SCNs in Queensland. It is suggested that evidence based guidelines need to be developed, and that, in order to do this, further research studies are required to determine current best practice, as well as to answer remaining questions. © 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Informed consent is the legal requirement to educate a patient about a proposed medical treatment or procedure so that he or she can make informed decisions. The purpose of the study was to examine the current practice for obtaining informed consent for third molar tooth extractions (wisdom teeth) by Oral and Maxillofacial Surgeons in Australia and New Zealand. Methods An online survey was sent to 180 consultant Oral and Maxillofacial Surgeons in Australia and New Zealand. Surgeons were asked to answer (yes/no) whether they routinely warned of a specific risk of third molar tooth extraction in their written consent. Results 71 replies were received (39%). The only risks that surgeons agreed should be routinely included in written consent were a general warning of infection (not alveolar osteitis), inferior alveolar nerve damage (temporary and permanent) and lingual nerve damage (temporary and permanent). Conclusions There is significant variability among Australian and New Zealand Oral and Maxillofacial Surgeons regarding risk disclosure for third molar tooth extractions. We aim to improve consistency in consent for third molar extractions by developing an evidence-based consent form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of local data, we write in support of the conclusions of Smith and Ahern that current Pharmaceu- tical Benefits Scheme (PBS) criteria for tumour necrosis factor (TNF)-a inhibitors in ankylosing spondylitis (AS) are not evidence-based. 1 As a prerequisite to the appropriate use of biological therapy in AS, three aspects of the disease need to be defined: (i) diagnosis, (ii) activity and (iii) therapeutic failure (Table 1)....

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the initial report by Warren and Marshall in 1984, Helicobacter pylori has assumed an increasingly important role in the pathogenesis of peptic ulcer disease and gastric carcinoma in all ages. A recent National Institutes of Health Consensus Development conference acknowledges the relationship between H. pylori infection and peptic ulcer disease and recommends that the medical community treat H. pylori infection in all patients with Helicobacter pylori and peptic ulcer. Although the same organism, the response to Helicobacter pylori infection in childhood differs somewhat from that seen in adults. The paediatric patient mounts a different inflammatory response, has different macroscopic appearances and has a markedly diminished peptic ulcer disease frequency compared with their adult counterparts. The appearances of antral nodularity appear to be characteristic of Helicobacter pylori infections. The appearances, however, are unrelated to symptoms and the underlying cause for this nodularity remains obscure. Younger children with peptic ulcer diseases are more likely to be Helicobacter pylori negative. This may suggest an increased susceptibility to gastric acid or possibly a very transient Helicobacter pylori infection rather than the well described lifelong infection without treatment. It is well known that the epidemiology of Helicobacter pylori would suggest that the incidence of infection increases with age. There is also geographical variations with the incidence being higher in countries of a third world background. These epidemiological observations fly in the face of all other infections where the major period of acquisition is in childhood. There has been recent evidence to suggest that in fact the incidence in childhood is decreasing in developed countries which could support the observation that there is a decreasing positive serology with successive decades in some countries. It is felt that the most likely mode of transmission of Helicobacter pylori is faecal to oral or oral to oral route. These are similar modes of transmission to Hepatitis A infections. It is obvious that most infections in childhood remain asymptomatic. It is also clear that there is no relationship between chronic recurrent abdominal pain of childhood syndrome and the presence of Helicobacter pylori infections. It remains to be seen as to who should be treated, what with and when. All of these issues will be discussed in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel test of recent theories of the origin of optical activity has been designed based on the inclusion of certain alkyl 2-methylhexanoates into urea channels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compulsators are power sources of choice for use in electromagnetic launchers and railguns. These devices hold the promise of reducing unit costs of payload to orbit. In an earlier work, the author had calculated the current distribution in compulsator wires by considering the wire to be split into a finite number of separate wires. The present work develops an integral formulation of the problem of current distribution in compulsator wires which leads to an integrodifferential equation. Analytical solutions, including those for the integration constants, are obtained in closed form. The analytical solutions present a much clearer picture of the effect of various input parameters on the cross-sectional current distribution and point to ways in which the desired current density distribution can be achieved. Results are graphically presented and discussed, with particular reference to a 50-kJ compulsator in Bangalore. Finite-element analysis supports the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current source inverter (CSI) is an attractive solution in high-power drives. The conventional gate turn-off thyristor (GTO) based CSI-fed induction motor drives suffer from drawbacks such as low-frequency torque pulsation, harmonic heating, and unstable operation at low-speed ranges. These drawbacks can be overcome by connecting a current-controlled voltage source inverter (VSI) across the motor terminal replacing the bulky ac capacitors. The VSI provides the harmonic currents, which results in sinusoidal motor voltage and current even with the CSI switching at fundamental frequency. This paper proposes a CSI-fed induction motor drive scheme where GTOs are replaced by thyristors in the CSI without any external circuit to assist the turning off of the thyristors. Here, the current-controlled VSI, connected in shunt, is designed to supply the volt ampere reactive requirement of the induction motor, and the CSI is made to operate in leading power factor mode such that the thyristors in the CSI are autosequentially turned off. The resulting drive will be able to feed medium-voltage, high-power induction motors directly. A sensorless vector-controlled CSI drive based on the proposed configuration is developed. The experimental results from a 5 hp prototype are presented. Experimental results show that the proposed drive has stable operation throughout the operating range of speeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vermicular graphite cast iron is a new addition to the family of cast irons. Various methods for producing vermicular graphite cast iron are briefly discussed in this paper. The mechanical and physical properties of cast irons with vermicular graphite have been found to be intermediate between those of gray and ductile irons. Other properties such as casting characteristics, scaling resistance, damping capacity and machinability have been compared with those of gray and ductile irons. Probable applications of vermicular graphite cast irons are suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following the method of Ioffe and Smilga, the propagation of the baryon current in an external constant axial-vector field is considered. The close similarity of the operator-product expansion with and without an external field is shown to arise from the chiral invariance of gauge interactions in perturbation theory. Several sum rules corresponding to various invariants both for the nucleon and the hyperons are derived. The analysis of the sum rules is carried out by two independent methods, one called the ratio method and the other called the continuum method, paying special attention to the nondiagonal transitions induced by the external field between the ground state and excited states. Up to operators of dimension six, two new external-field-induced vacuum expectation values enter the calculations. Previous work determining these expectation values from PCAC (partial conservation of axial-vector current) are utilized. Our determination from the sum rules of the nucleon axial-vector renormalization constant GA, as well as the Cabibbo coupling constants in the SU3-symmetric limit (ms=0), is in reasonable accord with the experimental values. Uncertainties in the analysis are pointed out. The case of broken flavor SU3 symmetry is also considered. While in the ratio method, the results are stable for variation of the fiducial interval of the Borel mass parameter over which the left-hand side and the right-hand side of the sum rules are matched, in the continuum method the results are less stable. Another set of sum rules determines the value of the linear combination 7F-5D to be ≊0, or D/(F+D)≊(7/12). .AE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature on the subject of the present investigation is somewhat meagre. A rotary converter or synchronous motor no! provided with any special starting devices forms, when started from the alternating current side, a type of induction motor whoso Htator is provided with a polyphase winding, and whoso rotor has a single-phase (or single magnetic axis) winding.