959 resultados para Coronary artery bypass


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Coronary endothelial function is abnormal in patients with established coronary artery disease and was recently shown by MRI to relate to the severity of luminal stenosis. Recent advances in MRI now allow the noninvasive assessment of both anatomic and functional (endothelial function) changes that previously required invasive studies. We tested the hypothesis that abnormal coronary endothelial function is related to measures of early atherosclerosis such as increased coronary wall thickness. METHODS AND RESULTS: Seventeen arteries in 14 healthy adults and 17 arteries in 14 patients with nonobstructive coronary artery disease were studied. To measure endothelial function, coronary MRI was performed before and during isometric handgrip exercise, an endothelial-dependent stressor, and changes in coronary cross-sectional area and flow were measured. Black blood imaging was performed to quantify coronary wall thickness and indices of arterial remodeling. The mean stress-induced change in cross-sectional area was significantly higher in healthy adults (13.5%±12.8%, mean±SD, n=17) than in those with mildly diseased arteries (-2.2%±6.8%, P<0.0001, n=17). Mean coronary wall thickness was lower in healthy subjects (0.9±0.2 mm) than in patients with coronary artery disease (1.4±0.3 mm, P<0.0001). In contrast to healthy subjects, stress-induced changes in cross-sectional area, a measure of coronary endothelial function, correlated inversely with coronary wall thickness in patients with coronary artery disease (r=-0.73, P=0.0008). CONCLUSIONS: There is an inverse relationship between coronary endothelial function and local coronary wall thickness in patients with coronary artery disease but not in healthy adults. These findings demonstrate that local endothelial-dependent functional changes are related to the extent of early anatomic atherosclerosis in mildly diseased arteries. This combined MRI approach enables the anatomic and functional investigation of early coronary disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé Objectifs: Cette étude relève la prévalence des principaux facteurs de risque cardiovasculaire dans les coronaropathies précoces (P-CAD) familiales, survenant chez au moins deux frères et/ou soeurs d'une même fratrie. Méthodes: Nous avons recruté 213 survivants atteints de P-CAD, issus de 103 fratries, diagnostiqués avant l'âge de 50 ans chez les hommes et 55 ans chez les femmes. La présence ou non d'hypertension, d'hypercholestérolémie, d'obésité et de tabagisme a été documentée au moment de l'événement chez 163 de ces patients (145 hommes et 18 femmes). Chaque patient a été comparé à deux individus de même âge et sexe, chez qui un diagnostic de P-CAD «sporadique» (non familiale) était posé, et à trois individus choisis au hasard parmi la population générale. Résultats: En comparaison de la population générale, les patients atteints de P-CAD sporadique avaient une prévalence supérieure pour l 'hypertension (29% vs. 14%, p<0.001), le cholestérol (54% vs. 33%, p<0.001), l'obésité (20% vs. 13%, p<0.001) et le tabagisme (76% vs. 39%, p<0.001). Ces facteurs de risque étaient de prévalences similaires, voire supérieures chez les patients atteints de P-CAD familiale (43% [p0.05 vs. P-CAD sporadiques], 58% [p=0.07], 21% et 72% respectivement). Seulement 7 (4%) des 163 patients atteints de P-CAD familiale et 22 (7%) des 326 patients atteints de P-CAD sporadique, ne présentaient aucun facteur de risque cardiovasculaire, comparés à 167 (34%) des 489 patients issus de la population générale. Conclusions: Les facteurs de risque cardiovasculaire classiques et réversibles ont une haute prévalence chez les patients atteints de P-CAD familiale. Ce fait rend improbable une contribution génétique prédominante, agissant en l'absence de facteurs de risque. Summary Objectives: This study was designed to assess the prevalence of major cardiovascular risk factors in familial premature coronary artery disease (P-CAD), affecting two or more siblings within one sibship. Background: Premature CAD has a genetic component. It remains to be established whether familial P-CAD is due to genes acting independently from major cardiovascular risk factors. Methods: We recruited 213 P-CAD survivors from 103 sibships diagnosed before age ?50 (men) or ?55 (women) years old. Hypertension, hypercholesterolemia, obesity, and smoking were documented at the time of the event in 163 patients (145 men and 18 women). Each patient was compared with two individuals of the same age and gender, diagnosed with sporadic (nonfamilial) P-CAD, and three individuals randomly sampled from the general population. Result: Compared with the general population, patients with sporadic P-CAD had a higher prevalence of hypertension (29% vs. 14%, p < 0.001), hypercholesterolemia (54% vs. 33%, p < 0.001), obesity (20% vs. 13%, p < 0.01), and smoking (76% vs. 39%, p < 0.001). These risk factors were equally or even more prevalent in patients with familial P-CAD (43% [p < 0.05 vs. sporadic P-CAD], 58% [p = 0.07], 21% and 72%, respectively). Overall, only 7 (4%) of 163 of patients with familial P-CAD and 22 (7%) of 326 of patients with sporadic P-CAD had none of these conditions, as compared with 167 (34%) of 489 patients in the general population. Conclusions: Classic, remediable risk factors are highly prevalent in patients with familial P-CAD. Accordingly, a major contribution of genes acting in the absence of these risk factors is unlikely.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The time-lag between coronary occlusion and irreversible damage to the myocardium is ill-defined in man. In 10 patients the changes in left ventricular function have been studied after coronary occlusion during diagnostic or therapeutic cardiac catheterization of 1-2 hours' duration. Revascularization was achieved either surgically or through intracoronary streptokinase infusion. The interval between occlusion and onset of extracorporal circulation or reopening was 61 to 119 minutes. Despite enzyme elevation (CPK, CK-MB, SGOT) and appearance of Q-waves in 5 patients, no significant alteration of left ventricular function was noted on repeat cardiac catheterization 10 to 230 days after the accident. These observations, suggest that coronary occlusion of 1-2 hours' duration fails to produce significant irreversible damage to the myocardium despite electrocardiographic and enzymatic signs of myocardial infarction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Because traditional nonsteroidal antiinflammatory drugs are associated with increased risk for acute cardiovascular events, current guidelines recommend acetaminophen as the first-line analgesic of choice on the assumption of its greater cardiovascular safety. Data from randomized clinical trials prospectively addressing cardiovascular safety of acetaminophen, however, are still lacking, particularly in patients at increased cardiovascular risk. Hence, the aim of this study was to evaluate the safety of acetaminophen in patients with coronary artery disease. METHODS AND RESULTS: The 33 patients with coronary artery disease included in this randomized, double-blind, placebo-controlled, crossover study received acetaminophen (1 g TID) on top of standard cardiovascular therapy for 2 weeks. Ambulatory blood pressure, heart rate, endothelium-dependent and -independent vasodilatation, platelet function, endothelial progenitor cells, markers of the renin-angiotensin system, inflammation, and oxidative stress were determined at baseline and after each treatment period. Treatment with acetaminophen resulted in a significant increase in mean systolic (from 122.4±11.9 to 125.3±12.0 mm Hg P=0.02 versus placebo) and diastolic (from 73.2±6.9 to 75.4±7.9 mm Hg P=0.02 versus placebo) ambulatory blood pressures. On the other hand, heart rate, endothelial function, early endothelial progenitor cells, and platelet function did not change. CONCLUSIONS: This study demonstrates for the first time that acetaminophen induces a significant increase in ambulatory blood pressure in patients with coronary artery disease. Thus, the use of acetaminophen should be evaluated as rigorously as traditional nonsteroidal antiinflammatory drugs and cyclooxygenase-2 inhibitors, particularly in patients at increased cardiovascular risk. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00534651.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Rotational thromboelastometry (ROTEM) is a whole blood point-of-test used to assess the patient's coagulation status. Three of the available ROTEM tests are EXTEM, INTEM and HEPTEM. In the latter, heparinase added to the INTEM reagent inactivates heparin to reveal residual heparin effect. Performing ROTEM analysis during cardiopulmonary bypass (CPB) might allow the anaesthesiologist to anticipate the need for blood products. OBJECTIVE: The goal of this study was to validate ROTEM analysis in the presence of very high heparin concentrations during CPB. DESIGN: Prospective, observational trial. SETTING: Single University Hospital. PARTICIPANTS: Twenty patients undergoing coronary artery bypass grafting. MAIN OUTCOME MEASURE: ROTEM analysis was performed before heparin administration (T0), 10 min after heparin (T1), at the end of CPB (T2) and 10 min after protamine (T3). The following tests were performed: EXTEM, INTEM, and HEPTEM. Heparin concentrations were measured at T1 and at the end of bypass (T2). RESULTS: At T1, EXTEM differed from baseline for coagulation time: +26.7 s (18.4 to 34.9, P < 0.0001), α: -3° (1.0 to 5.4, P = 0.006) and A10: -4.4 mm (2.3 to 6.5, P = 0.0004). INTEM at T0 was different from HEPTEM at T1 for coagulation time: + 47 s (34.3 to 59.6, P >0.0001), A10: -2.3 mm (0.5 to 4.0, P = 0.01) and α -2° (1.0 to 3.0; P = 0.0007). At T2, all parameters in EXTEM and HEPTEM related to fibrin-platelet interaction deteriorated significantly compared to T1. At T3, EXTEM and INTEM were comparable to EXTEM and HEPTEM at T2. CONCLUSION: HEPTEM and EXTEM measurements are valid in the presence of very high heparin concentrations and can be performed before protamine administration in patients undergoing cardiac surgery with CPB. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01455454.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx) does not change with repeated isometric handgrip (IHG) stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T) MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD). METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA), peak diastolic coronary flow velocity (PDFV) and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84). The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38). CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings demonstrate the repeatability of noninvasive 3T MRI assessment of CorEndoFx and support its use in future studies designed to determine the effects of acute interventions on coronary vasoreactivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.