917 resultados para Corneal irregularity corneal asymmetry
Resumo:
PURPOSE: To determine the main causes of penetrating keratoplasty indications at Hospital das Clínicas-UNICAMP (January, 1999 to December, 2003). METHODS: A non-comparative, retrospective series of case studies. The authors reviewed the files of 857 patients who underwent penetrating keratoplasty at Hospital das Clínicas-UNICAMP between 1999-2003 and classified them into different categories according to diagnostic indication for surgery. RESULTS: The age range was between 0-88 years (average 44 years ±1.2). The main causes of penetrating keratoplasty were: keratoconus in 427 cases (49.82%); 152 cases (17.74%) of corneal ulceration (perforated or not); corneal graft failure in 87 cases (10.15%); bullous keratopathy, 72 cases (8.40%); Fuchs dystrophy in 59 cases (6.88%); trachoma complications in 28 cases (3.27%); other causes, 32 (3.74%). In children under 10 years of age, the main cause of penetrating keratoplasty indications was infectious ulcer (77.78%) and between 11-50 years of age, keratoconus was the main cause (71.65%). CONCLUSION: This study was composed of a young population, and the main causes of penetrating keratoplasty were keratoconus and therapeutic keratoplasty.
Resumo:
PURPOSES: 1) To verify the impact of the creation of the Single Technical Record (STR) at the University of Campinas (Unicamp) Hospital das Clínicas, on the preservation period of corneas which were used in elective penetrating keratoplasties, and 2) to compare the primary failure incidence in cornea penetrating keratoplasties regarding the periods before and after the creation of STR. METHODS: A retrospective study was conducted at the Unicamp Hospital, which evaluated 15 consecutive cornea penetrating keratoplasties between January 1st and April 30th, 2000 and 24 consecutive penetrating keratoplasties between May 1st and September 20th of the same year (corneas under the control of the STR), totaling 39 keratoplasties. RESULTS: The mean time between cornea preparation and transplantation was 3.8 days (±1.78) in the period before STR creation, and 6.0 days (±2.97) after STR creation, representing a 36.7% increase in the preservation time. There was a statistically significant difference (p=0.02) between the two groups. No corneal primary failure was observed among the 39 transplanted patients in both groups. CONCLUSION: Based on the results of this study, it can be concluded that this new concept of the State Transplantation System has caused a statistically significant increase in the conservation period of corneas, which may reduce the period of a clear transplant due to an increased loss of endothelial cells, as well as increase the primary failure incidence or result in a high number of corneas that cannot be used due to having exceeded the preservation time recommended by the literature.
Resumo:
PURPOSE: To evaluate the ocular surface toxicity of two nitric oxide donors in ex vivo and in vivo animal models: S-nitrosoglutathione (GSNO) and S-nitroso-N-acetylcysteine (SNAC) in a hydroxypropyl methylcellulose (HPMC) matrix at final concentrations 1.0 and 10.0 mM. METHODS: Ex vivo GSNO and SNAC toxicities were clinically and histologically analyzed using freshly excised pig eyeballs. In vivo experiments were performed with 20 albino rabbits which were randomized into 4 groups (5 animals each): Groups 1 and 2 received instillations of 150 µL of aqueous HPMC solution containing GSNO 1.0 and 10.0 mM, respectively, in one of the eyes; Groups 3 and 4 received instillations of 150 µL of aqueous HPMC solution-containing SNAC 1.0 and 10.0 mM, respectively, in one of the eyes. The contralateral eyes in each group received aqueous HPMC as a control. All animals underwent clinical evaluation on a slit lamp and the eyes were scored according to a modified Draize eye test and were histologically analyzed. RESULTS: Pig eyeballs showed no signs of perforation, erosion, corneal opacity or other gross damage. These findings were confirmed by histological analysis. There was no difference between control and treated rabbit eyes according to the Draize eye test score in all groups (p>0.05). All formulations showed a mean score under 1 and were classified as non-irritating. There was no evidence of tissue toxicity in the histological analysis in all animals. CONCLUSION: Aqueous HPMC solutions containing GSNO and SNAC at concentrations up to 10.0 mM do not induce ocular irritation.
Resumo:
This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.
Resumo:
Class III skeletal malocclusion may present several etiologies, among which maxillary deficiency is the most frequent. Bone discrepancy may have an unfavorable impact on esthetics, which is frequently aggravated by the presence of accentuated facial asymmetries. This type of malocclusion is usually treated with association of Orthodontics and orthognathic surgery for correction of occlusion and facial esthetics. This report presents the treatment of a patient aged 15 years and 1 month with Class III skeletal malocclusion, having narrow maxilla, posterior open bite on the left side, anterior crossbite and unilateral posterior crossbite, accentuated negative dentoalveolar discrepancy in the maxillary arch, and maxillary and mandibular midline shift. Clinical examination also revealed maxillary hypoplasia, increased lower one third of the face, concave bone and facial profiles and facial asymmetry with mandibular deviation to the left side. The treatment was performed in three phases: presurgical orthodontic preparation, orthognathic surgery and orthodontic finishing. In reviewing the patient's final records, the major goals set at the beginning of treatment were successfully achieved, providing the patient with adequate masticatory function and pleasant facial esthetics.
Resumo:
The objective was to determine the cardiopulmonary effects and eyeball centralization time obtained with 15 or 30µg kg-1 of atracurium in anesthetized dogs under spontaneous breathing. Eighteen healthy adult mixed-breed dogs were used, which received 0.1mg kg-1 acepromazine and 0.5mg kg-1 morphine IM, followed by 4mg kg-1 propofol IV and maintained on isoflurane anesthesia with spontaneous breathing. Animals received 1mL 0.9% NaCl IV (CG), 15µg kg-1 (G15) or 30µg kg-1 (G30) of atracurium IV. Eyeball centralization time was measured; heart rate (HR), systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, respiratory rate (RR), tidal volume (Vt) and minute volume (Vm) were determined every 5min, and pH, arterial CO2 pressure (PaCO2 ), arterial O2 pressure (PaO2 ), hemoglobin oxygen saturation (SaO2 ), bicarbonate (HCO3-) and base excess (BE) every 15min until 60min. Both doses of atracurium produced a similar period of eyeball centralization. Vt in groups treated with atracurium was lower than in CG up to 15min. Vm in G15 differed from CG up to 10min and in G30 up to 25min. No differences were observed for cardiovascular parameters, RR, SaO2, PaO2, HCO3- and BE. pH decreased in CG between 30 and 60min and in G15 and G30 at 15min. G30 differed from CG between 15 and 30min. PaCO2 in GC differed from baseline between 30 and 60min and in G15 differed at 15min. Atracurium at the dose of 15µg kg-1 is adequate for short corneal procedures in inhalant-anesthetized dogs under spontaneous breathing.
Resumo:
We recently demonstrated that automatic attention favors the right side of space and, in the present study, we investigated whether voluntary attention also favors this side. Six reaction time experiments were conducted. In each experiment, 12 new 18-25-year-old male right-handed individuals were tested. In Experiments 1, 2, 3 (a, b) and 4 (a, b), tasks with increasing attentional demands were used. In Experiments 1, 2, 3a, and 4a, attention was oriented to one or both sides by means of a central spatially informative visual cue. A left or right side visual target appeared 100, 300, or 500 ms later. Attentional effects were observed in the four experiments. In Experiments 2, 3a and 4a, these effects were greater when the cue indicated the right side than when it indicated the left side (respectively: 16 ± 10 and 44 ± 6 ms, P = 0.015, for stimulus onset asynchrony of 500 ms in Experiment 2; 38 ± 10 and 70 ± 7 ms, P = 0.011, for Experiment 3a, and 23 ± 11 and 61 ± 10 ms, P = 0.009, for Experiment 4a). In Experiments 3b and 4b, the central cue pointed to both sides and was said to be non-relevant for task performance. In these experiments right and left reaction times did not differ. The most conservative interpretation of the present findings is that voluntary attention orienting favors the right side of space, particularly when a difficult task has to be performed.
Resumo:
PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
OBJECTIVE: This study seeks to identify practices of self-medication in the treatment of ocular emergencies. We examine patients' use of both homemade preparations and manufactured products before seeking specialized care. MATERIALS AND METHODS: We conducted a cross-sectional analytic survey of consecutive patients seen in the ophthalmology emergency room of a teaching hospital. RESULTS: The sample included 561 subjects, 51.3% males and 48.7% females, with a mean age of 39.8 years. Prior to seeking emergency care, 40.5% reported self-medicating; 29.4% used a homemade preparation (13.9% referred to an industrialized product like boric acid as a homemade preparation), and 11.1% used a manufactured product. The most frequently used products included a boric acid solution (53.3%), a normal saline solution (35.7%), herbal infusions (6.1%) and breast milk (4.8%). Viral conjunctivitis was the most frequent diagnosis (24.4%), followed by the presence of a corneal foreign body (7.4%). No significant differences were found in the self-treatment of ocular injuries according to gender (p = 0.95), level of education (p = 0.21) or age (p = 0.14). In addition, self-medication practices were not related to the medically judged severity of the condition. CONCLUSION: Patients often attempt to treat conditions that require ophthalmologic emergency care by self-medicating with homemade or manufactured products. The most widely used products include boric acid, normal saline, leaf infusions and breast milk. This behavior occurs independently of educational level, gender, age or the nature of the ocular condition. Self-medication is a culturally driven practice that is used even in cases of acute ocular injuries.
Resumo:
As technology improves human vision, some procedures currently performed may be causing a decrease of the natural UV protection of the cornea. A portable dual beam system prototype was assembled for physicians for clinical studies of these effects on the corneas endowing two types of 300-400 nm evaluations: 1, regularly donated corneas and 2, simulating refractive keratectomy by corneal lamellae removal. The system performs 500 measurements/s, providing +/- 0.25% precision for the transmittance. The measurements performed on the prototype are 95% in agreement with Cary 17 and HR4000CG-UV-NIR Ocean Optics spectrophotometers. Preliminary studies on cadaveric corneas demonstrate that, as the stromal layer is reduced (similar to 150 mu m depth), there is significant loss-an average of 7.1%.-of the cornea's natural UV protection. The prototype is being tested in an eye bank for routine evaluation of donor corneas. (C) 2010 Optical Society of America
Resumo:
We report a new STAR measurement of the longitudinal double-spin asymmetry A(LL) for inclusive jet production at midrapidity in polarized p+p collisions at a center-of-mass energy of root s = 200 GeV. The data, which cover jet transverse momenta 5 < p(T) < 30 GeV/c, are substantially more precise than previous measurements. They provide significant new constraints on the gluon spin contribution to the nucleon spin through the comparison to predictions derived from one global fit to polarized deep-inelastic scattering measurements. They provide significant new constraints on the gluon spin contribution to the nucleon spin through the comparison to predictions derived from one global fit to polarized deep-inelastic scattering measurements.
Resumo:
An optical photometric and spectroscopic analysis of the slowly-evolving type IIn SN 2007rt is presented, covering a duration of 481 days after discovery. Its earliest spectrum, taken approximately 100 days after the explosion epoch, indicates the presence of a dense circumstellar medium, with which the supernova ejecta is interacting. This is supported by the slowly-evolving light curve. A notable feature in the spectrum of SN 2007rt is the presence of a broad He I 5875 line, not usually detected in type IIn supernovae. This may imply that the progenitor star has a high He/H ratio, having shed a significant portion of its hydrogen shell via mass-loss. An intermediate resolution spectrum reveals a narrow H(alpha) P-Cygni profile, the absorption component of which has a width of 128 km s (1). This slow velocity suggests that the progenitor of SN 2007rt recently underwent mass-loss with wind speeds comparable to the lower limits of those detected in luminous blue variables. Asymmetries in the line profiles of H and He at early phases bears some resemblance to double-peaked features observed in a number of Ib/c spectra. These asymmetries may be indicative of an asymmetric or bipolar outflow or alternatively dust formation in the fast expanding ejecta. In addition, the late time spectrum, at over 240 days post-explosion, shows clear evidence for the presence of newly formed dust.
Resumo:
Measurements of double-helicity asymmetries in inclusive hadron production in polarized p + p collisions are sensitive to helicity-dependent parton distribution functions, in particular, to the gluon helicity distribution, Delta g. This study focuses on the extraction of the double-helicity asymmetry in eta production ((p) over right arrow + (p) over right arrow -> eta + X), the eta cross section, and the eta/pi(0) cross section ratio. The cross section and ratio measurements provide essential input for the extraction of fragmentation functions that are needed to access the helicity-dependent parton distribution functions.
Resumo:
The double helicity asymmetry in neutral pion production for p(T) = 1 to 12 GeV/c was measured with the PHENIX experiment to access the gluon-spin contribution, Delta G, to the proton spin. Measured asymmetries are consistent with zero, and at a theory scale of mu 2 = 4 GeV(2) a next to leading order QCD analysis gives Delta G([0.02,0.3]) = 0.2, with a constraint of -0.7 < Delta G([0.02,0.3]) < 0.5 at Delta chi(2) = 9 (similar to 3 sigma) for the sampled gluon momentum fraction (x) range, 0.02 to 0.3. The results are obtained using predictions for the measured asymmetries generated from four representative fits to polarized deep inelastic scattering data. We also consider the dependence of the Delta G constraint on the choice of the theoretical scale, a dominant uncertainty in these predictions.