860 resultados para Computed assited technologies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study intended to compare bone density and architecture in three groups of women: young women with anorexia nervosa (AN), an age-matched control group of young women, and healthy late postmenopausal women. Three-dimensional peripheral quantitative high resolution computed-tomography (HR-pQCT) at the ultradistal radius, a technology providing measures of cortical and trabecular bone density and microarchitecture, was performed in the three cohorts. Thirty-six women with AN aged 18-30years (mean duration of AN: 5.8years), 83 healthy late postmenopausal women aged 70-81 as well as 30 age-matched healthy young women were assessed. The overall cortical and trabecular bone density (D100), the absolute thickness of the cortical bone (CTh), and the absolute number of trabecules per area (TbN) were significantly lower in AN patients compared with healthy young women. The absolute number of trabecules per area (TbN) in AN and postmenopausal women was similar, but significantly lower than in healthy young women. The comparison between AN patients and post-menopausal women is of interest because the latter reach bone peak mass around the middle of the fertile age span whereas the former usually lose bone before reaching optimal bone density and structure. This study shows that bone mineral density and bone compacta thickness in AN are lower than those in controls but still higher than those in postmenopause. Bone compacta density in AN is similar as in controls. However, bone inner structure in AN is degraded to a similar extent as in postmenopause. This last finding is particularly troubling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

State University Audit Report - Report Letter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Investigating the educational technologies developed for promoting cardiovascular health in adults. Method Integrative review carried out in the databases of PubMed, SciELO and LILACS, with 15 articles selected. Results Over half (60%) of the studies were randomized clinical trials. The developed educational technologies were programs involving three strategies, with duration of one year, use of playful technologies with storytelling, computer programs or software for smartphones, and electronic brochure. These technologies resulted in reduction of blood pressure, weight, waist circumference, decreased hospitalizations and increased years of life. Conclusion The studies with better impact on the cardiovascular health of adults were those who brought the technology in the form of program and duration of one year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is based on a study of a reform in the organisation of maternity services in the United Kingdom, which aimed towards developing a more woman-centred model of care. After decades of fragmentation and depersonalisation of care, associated with the shift of birth to a hospital setting, pressure by midwives and mothers prompted government review and a relatively radical turnaround in policy. However, the emergent model of care has been profoundly influenced by concepts and technologies of monitoring. The use of such technologies as ultrasound scans, electronic foetal monitoring and oxytocic augmentation of labour, generally supported by epidural anaesthesia for pain relief, have accompanied the development of a particular ecological model of birth – often called active management –, which is oriented towards the idea of an obstetric norm. Drawing on analysis of women’s narrative accounts of labour and birth, this article discusses the impact on women’s embodiment in birth, and the sources of information they use about the status of their own bodies, their labour and that of the child. It also illustrates how the impact on women’s experiences of birth may be mediated by a relational model of support, through the provision of caseload midwifery care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the usefulness of computed tomography (CT), magnetic resonance imaging (MRI), and Doppler ultrasonography (US) in providing specific images of gouty tophi. METHODS: Four male patients with chronic gout with tophi affecting the knee joints (three cases) or the olecranon processes of the elbows (one case) were assessed. Crystallographic analyses of the synovial fluid or tissue aspirates of the areas of interest were made with polarising light microscopy, alizarin red staining, and x ray diffraction. CT was performed with a GE scanner, MR imaging was obtained with a 1.5 T Magneton (Siemens), and ultrasonography with colour Doppler was carried out by standard technique. RESULTS: Crystallographic analyses showed monosodium urate (MSU) crystals in the specimens of the four patients; hydroxyapatite and calcium pyrophosphate dihydrate (CPPD) crystals were not found. A diffuse soft tissue thickening was seen on plain radiographs but no calcifications or ossifications of the tophi. CT disclosed lesions containing round and oval opacities, with a mean density of about 160 Hounsfield units (HU). With MRI, lesions were of low to intermediate signal intensity on T(1) and T(2) weighting. After contrast injection in two cases, enhancement of the tophus was seen in one. Colour Doppler US showed the tophi to be hypoechogenic with peripheral increase of the blood flow in three cases. CONCLUSION: The MR and colour Doppler US images showed the tophi as masses surrounded by a hypervascular area, which cannot be considered as specific for gout. But on CT images, masses of about 160 HU density were clearly seen, which correspond to MSU crystal deposits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we argue that inventory models are probably not usefulmodels of household money demand because the majority of households does nothold any interest bearing assets. The relevant decision for most people is notthe fraction of assets to be held in interest bearing form, but whether to holdany of such assets at all. The implications of this realization are interesting and important. We find that(a) the elasticity of money demand is very small when the interest rate is small,(b) the probability that a household holds any amount of interest bearing assetsis positively related to the level of financial assets, and (c) the cost ofadopting financial technologies is positively related to age and negatively relatedto the level of education. Unlike the traditional methods of money demand estimation, our methodology allowsfor the estimation of the interest--elasticity at low values of the nominalinterest rate. The finding that the elasticity is very small for interest ratesbelow 5 percent suggests that the welfare costs of inflation are small. At interest rates of 6 percent, the elasticity is close to 0.5. We find thatroughly one half of this elasticity can be attributed to the Baumol--Tobin orintensive margin and half of it can be attributed to the new adopters or extensivemargin. The intensive margin is less important at lower interest rates and moreimportant at higher interest rates.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce mémoire est l’occasion de partager le résultat de la mise en place de ce dispositif de formation à distance que nous avons mené dans l’université du Cap-Vert. Dans la première partie, nous décrirons la nature de la politique éducative au Cap-Vert. Nous contextualiserons les principes de l’installation de l’université publique dans ce pays, ainsi que les intentions d’innovation pédagogique de cette université. La deuxième partie portera un regard complémentaire sur l’utilisation des TIC et de l’internet dans l’enseignement/apprentissage d’une langue, cas du français langue étrangère, et nous nous inspirerons des théories constructiviste et socio-constructiviste. Finalement, la troisième partie détaillera toutes les étapes de la conception et de la mise en place du dispositif de formation à distance. Dans cette troisième partie, nous aborderons dans un premier temps la question des enjeux et des risques du e-Learning et nous présenterons notre mission dans le projet « e-Learning.cv » mené par l’université. Puis, dans un deuxième temps nous analyserons quelques cours que nous avons mis en ligne, en sachant qu’un cours en ligne n’est pas la simple reproduction d’un support pédagogique imprimé mais il offre à l’apprenant un environnement multimédia et interactif. Finalement dans un troisième temps nous essayerons de prendre un peu de recul pour faire une analyse critique de ce que nous avons réalisé et essayer par là même de dégager les perspectives pour améliorer le travail effectué.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aquest treball es presenten les característiques dels sistemes ERP i quines són les necessitats que cobreixen, així com els principals ERP que hi ha al mercat, d'entre els quals se'n seleccionarà un per a la implantació en la nostra empresa, explicant els processos i passos necessaris per a aquesta implantació.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: "Virtual" autopsy by postmortem computed tomography (PMCT) can replace medical autopsy to a certain extent but has limitations for cardiovascular diseases. These limitations might be overcome by adding multiphase PMCT angiography. OBJECTIVE: To compare virtual autopsy by multiphase PMCT angiography with medical autopsy. DESIGN: Prospective cohort study. (ClinicalTrials.gov: NCT01541995) SETTING: Single-center study at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany, between 1 April 2012 and 31 March 2013. PATIENTS: Hospitalized patients who died unexpectedly or within 48 hours of an event necessitating cardiopulmonary resuscitation. MEASUREMENTS: Diagnoses from clinical records were compared with findings from both types of autopsy. New diagnoses identified by autopsy were classified as major or minor, depending on whether they would have altered clinical management. RESULTS: Of 143 eligible patients, 50 (35%) had virtual and medical autopsy. Virtual autopsy confirmed 93% of all 336 diagnoses identified from antemortem medical records, and medical autopsy confirmed 80%. In addition, virtual and medical autopsy identified 16 new major and 238 new minor diagnoses. Seventy-three of the virtual autopsy diagnoses, including 32 cases of coronary artery stenosis, were identified solely by multiphase PMCT angiography. Of the 114 clinical diagnoses classified as cardiovascular, 110 were confirmed by virtual autopsy and 107 by medical autopsy. In 11 cases, multiphase PMCT angiography showed "unspecific filling defects," which were not reported by medical autopsy. LIMITATION: These results come from a single center with concerted interest and expertise in postmortem imaging; further studies are thus needed for generalization. CONCLUSION: In cases of unexpected death, the addition of multiphase PMCT angiography increases the value of virtual autopsy, making it a feasible alternative for quality control and identification of diagnoses traditionally made by medical autopsy. PRIMARY FUNDING SOURCE: University Medical Center Hamburg-Eppendorf.