950 resultados para Computational fluid dynamics modeling
Resumo:
Axial-flux machines tend to have cooling difficulties since it is difficult to arrange continuous heat path between the stator stack and the frame. One important reason for this is that no shrink fitting of the stator is possible in an axial-flux machine. Using of liquid-cooled end shields does not alone solve this issue. Cooling of the rotor and the end windings may also be difficult at least in case of two-stator-single-rotor construction where air circulation in the rotor and in the end-winding areas may be difficult to arrange. If the rotor has significant losses air circulation via the rotor and behind the stator yokes should be arranged which, again, weakens the stator cooling. In this paper we study a novel way of using copper bars as extra heat transfer paths between the stator teeth and liquid cooling pools in the end shields. After this the end windings still suffer of low thermal conductivity and means for improving this by high-heat-conductance material was also studied. The design principle of each cooling system is presented in details. Thermal models based on Computational Fluid Dynamics (CFD) are used to analyse the temperature distribution in the machine. Measurement results are provided from different versions of the machine. The results show that significant improvements in the cooling can be gained by these steps.
Resumo:
Regional Research Laboratory
Resumo:
Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.
Resumo:
In the present work, the author has designed and developed all types of solar air heaters called porous and nonporous collectors. The developed solar air heaters were subjected to different air mass flow rates in order to standardize the flow per unit area of the collector. Much attention was given to investigate the performance of the solar air heaters fitted with baffles. The output obtained from the experiments on pilot models, helped the installation of solar air heating system for industrial drying applications also. Apart from these, various types of solar dryers, for small and medium scale drying applications, were also built up. The feasibility of ‘latent heat thermal energy storage system’ based on Phase Change Material was also undertaken. The application of solar greenhouse for drying industrial effluent was analyzed in the present study and a solar greenhouse was developed. The effectiveness of Computational Fluid Dynamics (CFD) in the field of solar air heaters was also analyzed. The thesis is divided into eight chapters.
Resumo:
Die Trocknung ist eines der am häufigsten verwendeten Verfahren, um die Haltbarkeit von landwirtschaftlichen Gütern zu verlängern. Von den vielen gebräuchlichen Trocknungsarten ist die Konvektionstrocknung, die Luft als Energie- und Feuchteträger verwendet, weiterhin die wichtigste. Trotz ihrer Nachteile und ihres hohen spezifischen Energieverbrauchs sind Satztrockner für die Getreide-, Kräuter- und Heutrocknung noch weit verbreitet. Ferner werden Konvektionstrockner gemeinhin zur künstlichen Trocknung eingesetzt. Diese Arbeit ist Teil eines Forschungsprojekts, welches eine sorptionsgestützte solare Trocknung von landwirtschaftlichen Gütern untersucht. Bei dieser wird kühle feuchte Luft in Kontakt mit einer konzentrierten hygroskopischen Salzlösung gebracht. Während dieses Prozesses wird die Luft entfeuchtet und mit Hilfe der freigesetzten Verdampfungsenthalpie erwärmt. Die Anwendung dieses Verfahrens zur Trocknung landwirtschaftlicher Güter ist besonders interessant für Produkte, die bei niedrigen Temperaturen verarbeitet werden, um ihre Qualität nicht negativ zu beeinflussen. Bei allen energieintensiven Prozessen und vor allem bei der Verwendung von Solarenergie ist ein effizienter Energieverbrauch äußerst wichtig für den technischen und ökonomischen Erfolg. Eine ungleichmäßige Trocknung ist oftmals bei Satztrocknern zu beobachten, was die Energieeffizienz negativ beeinflusst. Aus diesem Grund lag im agrartechnischen Teil des Projekts der Schwerpunkt auf der Trocknung bei niedrigen Temperaturen und geringer Luftfeuchte, die der Sorptionsprozess liefert, sowie auf der Verbesserung der Luftverteilung und der Gleichmäßigkeit der Trocknung in lockeren und verdichteten Schüttungen. Es wurden Dünnschicht-Trocknungsexperminente für Blattsellerie bei unterschiedlichen Lufttemperaturen und unterschiedlicher relativer Luftfeuchte durchgeführt. Die Ergebnisse zeigen eindeutig, dass nicht nur die Lufttemperatur einen großen Einfluss auf die Trocknungsgeschwindigkeit hat, sondern auch die relative Luftfeuchte. Dies ist vor allem bei niedrigen Temperaturen, wie sie vom Sorptionssystem geliefert werden, der Fall. Um die Luftverteilung und Gleichmäßigkeit der Trocknung lockerer Schüttungen zu untersuchen, wurde ein Kistentrockner experimentell und in Strömungssimulationen getestet. Die Leistung des ursprünglichen Trockners wurde signifikant durch einfache Veränderungen des Designs verbessert. Diese stellten einen gleichmäßigeren Luftstrom durch das Produkt sicher. Die Trocknung von Heu-Rundballen stellt eine Herausforderung dar, da diese sehr stark verdichtet sind und die Dichte innerhalb eines Ballens stark schwankt. Strömungs- und Trocknungssimulationen so wie experimentelle Messungen zeigten, dass das Trocknerdesign einen großen Einfluss auf die Gleichmäßigkeit der Trocknung hat. Bei den einfachsten Trocknervarianten war die Verteilung auch bei optimal gepressten Ballen unzureichend, während komplexere Trockner eine gleichmäßigere Trocknung erzielten. Jedoch werden auch hier die Ergebnisse stark von der Verteilung der Dichte im Ballen beeinflusst, welche in der Praxis weiterhin nicht ideal ist. Abschließend wurde, um den Trocknungsfortschritt zu überwachen, eine Methodik getestet, bei der zur Messung des durchschnittlichen aktuellen Feuchtegehalts des Produktes psychrometrische Messungen und Messungen des Luftstroms in kurzen Abständen durchgeführt wurden. Die Menge des tatsächlich entfernten Wassers stimmte in den meisten Fällen gut mit der geschätzten Menge überein. Jedoch hängt der Erfolg dieser Methode stark von der Genauigkeit der Messfühler ab.
Resumo:
In composite agricultural materials such as grass, tee, medicinal plants; leaves and stems have a different drying time. By this behavior, after leaving the dryer, the stems may have greater moisture content than desired, while the leaves one minor, which can cause either the appearance of fungi or the collapse of the over-dried material. Taking into account that a lot of grass is dehydrated in forced air dryers, especially rotary drum dryers, this research was developed in order to establish conditions enabling to make a separation of the components during the drying process in order to provide a homogeneous product at the end. For this, a rotary dryer consisting of three concentric cylinders and a circular sieve aligned with the more internal cylinder was proposed; so that, once material enters into the dryer in the area of the inner cylinder, stems pass through sieve to the middle and then continue towards the external cylinder, while the leaves continue by the inner cylinder. For this project, a mixture of Ryegrass and White Clover was used. The characteristics of the components of a mixture were: Drying Rate in thin layer and in rotation, Bulk density, Projected Area, Terminal velocity, weight/Area Ratio, Flux through Rotary sieve. Three drying temperatures; 40°C, 60° C and 80° C, and three rotation speeds; 10 rpm, 20 rpm and 40 rpm were evaluated. It was found that the differences in drying time are the less at 80 °C when the dryer rotates at 40 rpm. Above this speed, the material adheres to the walls of the dryer or sieve and does not flow. According to the measurements of terminal velocity of stems and leaves of the components of the mixture, the speed of the air should be less than 1.5 m s-1 in the inner drum for the leaves and less than 4.5 m s-1 in middle and outer drums for stems, in such way that only the rotational movement of the dryer moves the material and achieves a greater residence time. In other hand, the best rotary sieve separation efficiencies were achieved when the material is dry, but the results are good in all the moisture contents. The best rotary speed of sieve is within the critical rotational speed, i.e. 20 rpm. However, the rotational speed of the dryer, including the sieve in line with the inner cylinder should be 10 rpm or less in order to achieve the greatest residence times of the material inside the dryer and the best agitation through the use of lifting flights. With a finite element analysis of a dryer prototype, using an air flow allowing speeds of air already stated, I was found that the best performance occurs when, through a cover, air enters the dryer front of the Middle cylinder and when the inner cylinder is formed in its entirety through a sieve. This way, air flows in almost equal amounts by both the middle and external cylinders, while part of the air in the Middle cylinder passes through the sieve towards the inner cylinder. With this, leaves do not adhere to the sieve and flow along drier, thanks to the rotating movement of the drums and the showering caused by the lifting flights. In these conditions, the differences in drying time are reduced to 60 minutes, but the residence time is higher for the stems than for leaves, therefore the components of the mixture of grass run out of the dryer with the same desired moisture content.
Resumo:
La dinàmica de fluids computacional (CFD) és una eina que serveix per analitzar mitjançant computadors diferents problemes que involucren fluxos de fluids. Els programes de CFD usen expressions matemàtiques no lineals que defineixen les equacions fonamentals de fluxos i transport de calor en fluids. Aquestes es resolen amb complexos algoritmes iteratius. Actualment aquesta eina és una part fonamental en els procés de disseny en moltes empreses relacionades amb la dinàmica de fluids. Les simulacions que es realitzen amb aquests programes s’ha demostrat que són fiables i que estalvien temps i diners, ja que eviten haver de realitzar els costosos processos d’assaig-error. En el projecte s’utilitza el programa de CFD Ansys CFX 11.0 per simular una agitació bifàsica composta per aigua i aire a temperatura ambient. Els objectius són determinar els paràmetres òptims de simulació que permetin recrear aquesta agitació, per posteriorment dissenyar un nou impulsor
Resumo:
Aquest projecte té com a objectiu la simulació numérica de la carrosseria d’ un vehicle de curses de muntanya de categoria CM
Resumo:
Although climate models have been improving in accuracy and efficiency over the past few decades, it now seems that these incremental improvements may be slowing. As tera/petascale computing becomes massively parallel, our legacy codes are less suitable, and even with the increased resolution that we are now beginning to use, these models cannot represent the multiscale nature of the climate system. This paper argues that it may be time to reconsider the use of adaptive mesh refinement for weather and climate forecasting in order to achieve good scaling and representation of the wide range of spatial scales in the atmosphere and ocean. Furthermore, the challenge of introducing living organisms and human responses into climate system models is only just beginning to be tackled. We do not yet have a clear framework in which to approach the problem, but it is likely to cover such a huge number of different scales and processes that radically different methods may have to be considered. The challenges of multiscale modelling and petascale computing provide an opportunity to consider a fresh approach to numerical modelling of the climate (or Earth) system, which takes advantage of the computational fluid dynamics developments in other fields and brings new perspectives on how to incorporate Earth system processes. This paper reviews some of the current issues in climate (and, by implication, Earth) system modelling, and asks the question whether a new generation of models is needed to tackle these problems.
Resumo:
This paper discusses experimental and theoretical investigations and Computational Fluid Dynamics (CFD) modelling considerations to evaluate the performance of a square section wind catcher system connected to the top of a test room for the purpose of natural ventilation. The magnitude and distribution of pressure coefficients (C-p) around a wind catcher and the air flow into the test room were analysed. The modelling results indicated that air was supplied into the test room through the wind catcher's quadrants with positive external pressure coefficients and extracted out of the test room through quadrants with negative pressure coefficients. The air flow achieved through the wind catcher depends on the speed and direction of the wind. The results obtained using the explicit and AIDA implicit calculation procedures and CFX code correlate relatively well with the experimental results at lower wind speeds and with wind incidents at an angle of 0 degrees. Variation in the C-p and air flow results were observed particularly with a wind direction of 45 degrees. The explicit and implicit calculation procedures were found to be quick and easy to use in obtaining results whereas the wind tunnel tests were more expensive in terms of effort, cost and time. CFD codes are developing rapidly and are widely available especially with the decreasing prices of computer hardware. However, results obtained using CFD codes must be considered with care, particularly in the absence of empirical data.
Resumo:
Wind catcher systems have been employed in buildings in the Middle East for many centuries and they are known by different names in different parts of the region. Recently there has been an increase in the application of this approach for natural ventilation and passive cooling in the UK and other countries. This paper presents the results of experimental wind tunnel and smoke visualisation testing, combined with CFD modelling, to investigate the performance of the wind catcher. For this purpose, a full-scale commercial system was connected to a test room and positioned centrally in an open boundary wind tunnel. Because much ventilation design involves the use of computational fluid dynamics, the measured performance of the system was also compared against the results of CFD analysis. Configurations included both a heated and unheated space to determine the impact of internal heat sources on airflow rate. Good comparisons between measurement and CFD analysis were obtained. Measurements showed that sufficient air change could be achieved to meet both air quality needs and passive cooling.
Resumo:
This paper presents the results of performance monitoring under real winter weather conditions, controlled laboratory testing and computational fluid dynamics (CFD) analysis of a wall mounted ventilation air inlet heat convector. For real winter weather monitoring, the wall-mounted convector was installed in a laboratory room of the Engineering Building of the School of Construction Management and Engineering. Air and hot water temperatures and air speeds were measured at the entrance to the convector and in the room. The hot water temperature was controlled at 40, 60 and 80 °C. The monitoring results were later used as boundary conditions for a CFD simulation to investigate the air movement in the room. Controlled laboratory testing was conducted in laboratories at the University of Reading, UK and at Wetterstad Consultancy, Sweden. The results of the performance investigation showed that the system contributed greatly to the room heating, particularly at a water temperature of 80 °C. Also adequate fresh air was supplied to the room. Such a system is able to provide an energy efficient method of eliminating problems associated with cold winter draughts.
Resumo:
The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.
Resumo:
A unified view on the interfacial instability in a model of aluminium reduction cells in the presence of a uniform, vertical, background magnetic field is presented. The classification of instability modes is based on the asymptotic theory for high values of parameter β, which characterises the ratio of the Lorentz force based on the disturbance current, and gravity. It is shown that the spectrum of the travelling waves consists of two parts independent of the horizontal cross-section of the cell: highly unstable wall modes and stable or weakly unstable centre, or Sele’s modes. The wall modes with the disturbance of the interface being localised at the sidewalls of the cell dominate the dynamics of instability. Sele’s modes are characterised by a distributed disturbance over the whole horizontal extent of the cell. As β increases these modes are stabilized by the field.