949 resultados para Color Doppler Sonography
Resumo:
Body color polymorphism of urban populations of cosmopolite fly Drosophila kikkawai Burla, 1954 was investigated in relation to its possible association with environmental temperature. Samples of D. kikkawai were collected in spring, summer, autumn and winter between 1987 to 1988, in zones with different levels of urbanization in the southern Brazilian city of Porto Alegre, Rio Grande do Sul. A clear association was observed between darker flies and both seasons with low temperatures and areas of low urbanization (where temperature is generally lower than in urbanized areas). Results of preliminary laboratory experiments involving six generations of flies grown in chambers at temperatures of 17º and 25ºC confirmed this tendency to a relationship between body color and temperature, with allele frequency of the main gene involved in body pigmentation changing over time.
Resumo:
The genus Sporophila (Cabanis, 1844) unites about 30 species of small seedeaters that predominantly inhabit open or semi-open areas in the Neotropical region. The taxonomy of this group is based on morphological studies from collected male specimens. The dynamic spatial and temporal variation in the male plumage and lack of knowledge of their vocalizations make it difficult to properly diagnose some species even today, so these two aspects account for the existing taxonomic dilemmas involving Sporophila. During a four-year field study, we investigated the natural history of a breeding population of Sporophila melanogaster (Pelzeln, 1870). This is an endemic species in Brazil, which reproduces in the high-altitude grasslands of the Atlantic Forest biome. We found four male specimens with clearly diagnosable plumage, distinct from the typical form of the species. Here we describe this previously unreported plumage form. Based on the evaluation of habitat use, vocalization, and reproductive behavior, we tested two hypotheses regarding its taxonomic status. We concluded that this is another case of an intra-specific color morph within the seedeaters of the "capuchinos" group.
Resumo:
S’analitza la visió daltònica i les dificultats que aquesta comporta en l'àmbit escolar. D’una banda, partint de les conseqüències del daltonisme com a anomalia genètica i de la seva alta incidència en la població, es subratlla la importància de la detecció i els problemes –en especial psicològics- que es poden derivar de la manca de detecció precoç. A més, prenent d'una mostra d'exercicis reals - extrets de llibres utilitzats a les escoles i instituts de Catalunya- s'analitzen diverses situacions en què per arribar al contingut didàctic cal poder distingir els colors. L'estudi de les dificultats cromàtiques realitzat abarca les tres etapes educatives: infantil (aprenentatge de les vocals a través del color), primària i ESO( principalment els continguts de llibres de text). Finalment, es proposen solucions adreçades a les editorials, educadors, pares, mares i als mateixos afectats.
Resumo:
Aquesta memoria resumeix el treball de final de carrera d’Enginyeria Superior d’Informàtica. Explicarà les principals raons que han motivat el projecte així com exemples que il·lustren l’aplicació resultant. En aquest cas el software intentarà resoldre la actual necessitat que hi ha de tenir dades de Ground Truth per als algoritmes de segmentació de text per imatges de color complexes. Tots els procesos seran explicats en els diferents capítols partint de la definició del problema, la planificació, els requeriments i el disseny fins a completar la il·lustració dels resultats del programa i les dades de Ground Truth resultants.
Resumo:
Monocytes are central mediators in the development of atherosclerotic plaques. They circulate in blood and eventually migrate into tissue including the vessel wall where they give rise to macrophages and dendritic cells. The existence of monocyte subsets with distinct roles in homeostasis and inflammation suggests specialization of function. These subsets are identified based on expression of the CD14 and CD16 markers. Routinely applicable protocols remain elusive, however. Here, we present an optimized four-color flow cytometry protocol for analysis of human blood monocyte subsets using a specific PE-Cy5-conjugated monoclonal antibody (mAb) to HLA-DR, a PE-Cy7-conjugated mAb to CD14, a FITC-conjugated mAb to CD16, and PE-conjugated mAbs to additional markers relevant to monocyte function. Classical CD14(+)CD16(-) monocytes (here termed "Mo1" subset) expressed high CCR2, CD36, CD64, and CD62L, but low CX(3)CR1, whereas "nonclassical" CD14(lo)CD16(+) monocytes (Mo3) essentially showed the inverse expression pattern. CD14(+)CD16(+) monocytes (Mo2) expressed high HLA-DR, CD36, and CD64. In patients with stable coronary artery disease (n = 13), classical monocytes were decreased, whereas "nonclassical" monocytes were increased 90% compared with healthy subjects with angiographically normal coronary arteries (n = 14). Classical monocytes from CAD patients expressed higher CX(3)CR1 and CCR2 than controls. Thus, stable CAD is associated with expansion of the nonclassical monocyte subset and increased expression of inflammatory markers on monocytes. Flow cytometric analysis of monocyte subsets and marker expression may provide valuable information on vascular inflammation. This may translate into the identification of monocyte subsets as selective therapeutic targets, thus avoiding adverse events associated with indiscriminate monocyte inhibition.
Resumo:
La rigidez arterial es un parámetro establecido dentro de la valoración del riesgo cardio-vascular. Actualmente disponemos de múltiples métodos para determinar la velocidad de onda de pulso (VOP) y entre ellos los más utilizados son los métodos mecánicos, como el Complior o el Sphigmocor, que precisan de dispositivos específicos y una inversión importante en aprendizaje y tiempo de exploración. La utilización del doppler guiado por ecografía 2D es una buena alternativa a estos métodos. Realizamos un estudio comparativo para evaluar la fiabilidad del eco-doppler en la medida de la VOP carótida-femoral respecto al método Complior. Se estudió la VOP carótida-femoral utilizando los dos sistemas en 40 pacientes, mostrando ambos métodos muy buena concordancia (R=0’91). En el análisis de reproducibilidad de la VOP por doppler no se hallaron diferencias intra e interobservador. En base a los resultados, el estudio demuestra que la ecografía doppler puede ser usada para medir la VOP aórtica de manera fiable y reproducible, similar otros métodos más establecidos.
Resumo:
Background: patients with axial Spondyloarthritis (SD), even withoutany obvious peripheral joint synovitis, often complain of pain in thejoints of arms and legs. Several musculoskeletal ultrasound (US)scores developed in rheumatoid arthritis have demonstrated theircapacity of discovering subclinical synovitis which were relevant interm of disease activity and for treatment strategies. None of thesescores however have been, to our knowledge, applied tospondyloarthritis patients.Objectives: to determine if subclinical synovitis can be detected byechography in patients with SD and if these synovitis are relevantcompared with RA and controls.Methods: the Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a reproducible semi-quantitative scorefor RA using OMERACT criteria for synovitis. The score includes Bmode and Doppler mode. 35 out of 40 enrolled SD patients fulfillingthe 2010 diagnostic criteria were evaluated according to the SONARscore. In none of them, peripheral synovitis was clearly demonstrated,although some have or reported recurrent peripheral joint pain. Thescore was also applied to 20 matched controls and 40 consecutive RApatients (RA). 19 of them were in remission (DAS: <2.6), 10 with alow activity (DAS: 2.6 <>3.4) and 11 with a moderate activity disease(DAS: 3.5 <>5.1). All the patients and the controls had a completeclinical, biological and auto-evaluation assessment (joint pain andswelling counts, DAS28, HAQ, BASDAI BASMI, BASFI, m-SACRAH).The ultra-sonographer was blind to all these parameters.Results: a B mode score >8, was set up as a cut-off value forsignificant synovitis as only 10% of the controls (median: 5.9 ± 2.2)and 90% of active RA had a higher score .34% of SD had significantsynovitis which remained mostly mild. Their median B mode score(12 ± 1.6) was higher but not significantly than in remission Ra (7.1 ±3.4). Only active RA (DAS >3.5) had significant higher echographicscores: B mode (17 ± 11), Doppler score and cumulative score forsynovitis grade >1. BASDAI, BASFI, BASMI, m-SACRAH, DAS28 andCRP were not significantly different in SD patients with or withoutsynovitis.Conclusions: some patients with axial Spondyloarthritis havesubclinical but significant peripheral synovitis detected by echography.The impact of these synovitis remains uncertain as their presencedoes not seem to significantly influence disease activity and functionevaluation tools.
Resumo:
L’ús de colorants alimentaris pot ser controvertit, ja que la seva presència s’associa amb problemes provocats pel seu consum a llarg termini, o perquè es tem que siguin emprats per dissimular deficiències en la qualitat del producte. Aquesta preocupació és una tendència creixent entre els consumidors i ha portat a moltes empreses del sector alimentari a revisar la formulació dels seus productes i substituir, sempre que sigui econòmica i tecnològicament possible, els colorants artificials per colorants naturals. L’hemoglobina procedent de la sang dels escorxadors industrials podria ser una font important de colorant vermell natural degut a les grans quantitats generades diàriament. A més, s' evitaria que anés a parar a les aigües residuals. El seu ús com a colorant vermell natural queda supeditada al fet de trobar alguna substància o sistema capaç de protegir-la de l’oxidació durant el procés de deshidratació i el posterior període d’emmagatzematge ja que l’hemoglobina és poc estable i es poden produir canvis en el seu color. Inicialment l’hemoglobina presenta un color vermell brillant. La seva desoxigenació comporta un canvi a color porpra. I l’oxidació del ferro confereix a la molècula un indesitjable color marró. En l’estudi que aquí es presenta es pretén estabilitzar el color de l’hemoglobina de sang porcina tant durant la seva deshidratació per atomització com durant l’emmagatzematge a temperatura ambient de la pols obtinguda afegint al concentrat d’hemoglobina, prèviament a la deshidratació, combinacions de diferents substàncies que puguin actuar de manera complementària en l’estabilització del ferro hèmic enfront la seva oxidació. L’objectiu d’aquest treball és determinar si la seva combinació amb agents antioxidants comporta una millora en l’estabilització de la forma reduïda de l’hemoglobina tant durant la deshidratació per atomització com durant l’emmagatzematge de la pols a temperatura ambient
Resumo:
OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.
Resumo:
En la última década, Barcelona se ha convertido en una importante receptora de población inmigrante. Según datos estadísticos, el 14, 62% de la población es inmigrante, de los cuales el 29, 5% son jóvenes (Idescat 2010). Muchos de estos han arribado siguiendo el típico proceso de reagrupamiento familiar. El siguiente trabajo tiene por objetivo presentar la experiencia de distintos jóvenes sobre el fenómeno migratorio que experimentaron durante su adolescencia/ primera juventud. Lleva el propósito de destacar la importancia de dicha vivencia en la conformación de su identidad social. Se intentará indagar tanto sobre el papel que jugaron los diferentes actores implicados en el proceso de acogida y los años subsiguientes: amigos, familiares, escuela, administraciones, etc., como sobre el uso del espacio público y el espacio virtual en tanto facilitadores/obstaculizadores de su constitución como ciudadanos autónomos
Resumo:
L'objectiu principal d'aquest treball és establir si l'anàlisi dels histogrames de color és eficient per classificar obres d'art. A partir d'un conjunt d'imatges d'obres d'art els atributs de les quals coneixem, s'ha generat un programari que permet establir la precisió de la classificació en cas que es fes servir com a conjunt d'entrenament per a reconèixer altres imatges.