912 resultados para COINCIDENCE MEASUREMENTS
Resumo:
One of the key challenges in the field of nanoparticle (NP) analysis is in producing reliable and reproducible characterisation data for nanomaterials. This study looks at the reproducibility using a relatively new, but rapidly adopted, technique, Nanoparticle Tracking Analysis (NTA) on a range of particle sizes and materials in several different media. It describes the protocol development and presents both the data and analysis of results obtained from 12 laboratories, mostly based in Europe, who are primarily QualityNano members. QualityNano is an EU FP7 funded Research Infrastructure that integrates 28 European analytical and experimental facilities in nanotechnology, medicine and natural sciences with the goal of developing and implementing best practice and quality in all aspects of nanosafety assessment. This study looks at both the development of the protocol and how this leads to highly reproducible results amongst participants. In this study, the parameter being measured is the modal particle size.
Resumo:
We report on the magneto-optical measurements of an epitaxial SrRuO3 film grown on SrTiO3 (0 0 1), which previously was determined to be single domain orientated by x-ray diffraction and Raman spectroscopy techniques. Our experiments reveal a large Kerr rotation, which reaches a maximum value of about 0.5° at low temperature. By measuring magnetic hysteresis loops at different temperatures, we determined the temperature dependence of the Kerr rotation in the polar configuration. Values of the anisotropic magnetoresistance ~ 20% have been measured. These values are remarkably higher than those of other metallic oxides such as manganites. This striking difference can be attributed to the strong spin-orbit interaction of the Ru 4d ion in the SrRuO3 compound.
Resumo:
Modern agriculture techniques have a great impact on crops and soil quality, especially by the increased machinery traffic and weight. Several devices have been developed for determining soil properties in the field, aimed at managing compacted areas. Penetrometry is a widely used technique; however, there are several types of penetrometers, which have different action modes that can affect the soil resistance measurement. The objective of this study was to compare the functionality of two penetrometry methods (manual and automated mode) in the field identification of compacted, highly mechanized sugarcane areas, considering the influence of soil water volumetric content (θ) on soil penetration resistance (PR). Three sugarcane fields on a Rhodic Eutrudrox were chosen, under a sequence of harvest systems: one manual harvest (1ManH), one mechanized harvest (1MH) and three mechanized harvests (3MH). The different degrees of mechanization were associated to cumulative compaction processes. An electronic penetrometer was used on PR measurements, so that the rod was introduced into the soil by hand (Manual) and by an electromechanical motor (Auto). The θ was measured in the field with a soil moisture sensor. Results showed an effect of θ on PR measurements and that regression models must be used to correct data before comparing harvesting systems. The rod introduction modes resulted in different mean PR values, where the "Manual" overestimated PR compared to the "Auto" mode at low θ.
Resumo:
Selostus: Hiehojen elopainon määrittäminen mittauksin alkukasvatusvaiheessa
Resumo:
The particle orientation in several Y-Fe2O3magnetic tapes has been quantitatively evaluated by using the data of both Mössbauer and hysteresis loop measurements performed in the three orthogonal directions. A texture function has been obtained as a development of real harmonics. The profile of the texture function gives the quality of the different magnetic tapes. A different degree of particle orientation at the surface of the tape is evidenced by means of conversion electron Mössbauer spectra.
Resumo:
The IRA and the NPL have submitted ampoules of 166Hom to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures, thus becoming the third and fourth participants since 1989. The five samples of known activity of 166Hom now recorded in the SIR have activities between about 70 kBq and 500 kBq. The new results have enabled a re-evaluation of the key comparison reference value, and the degrees of equivalence between each equivalent activity measured in the SIR and the key comparison reference value (KCRV) have been calculated. The results are given in the form of a matrix for these four NMIs together with the recalculated degrees of equivalence of an APMP regional comparison held in 2000, comparison identifier APMP.RI(II)-K2.Ho-166m for six other NMIs. A graphical presentation is also given.
Resumo:
[cat] En l'article es dona una condició necessària per a que els conjunts de negociació definits per Shimomura (1997) i el nucli d'un joc cooperatiu amb utilitat transferible coincideixin. A tal efecte, s'introdueix el concepte de vectors de màxim pagament. La condició necessària consiteix a verificar que aquests vectors pertanyen al nucli del joc.
Resumo:
[cat] A Navas i Marín Solano es va demostrar la coincidència entre els equilibris de Nash i de Stackelberg per a una versi´o modificada del joc diferencial proposat por Lancaster (1973). Amb l’objectiu d’obtenir una solució interior, es van imposar restriccions importants sobre el valors dels paràmetres del model. En aquest treball estenem aquest resultat, en el límit en que la taxa de descompte és igual a zero, eliminant les restriccions i considerant totes les solucions possibles.
Non-contact assessment of waist circumference: will tape measurements become progressively obsolete?
Resumo:
Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.
Resumo:
A key feature of memory processes is to link different input signals by association and to preserve this coupling at the level of synaptic connections. Late-phase long-term potentiation (L-LTP), a form of synaptic plasticity thought to encode long-term memory, requires gene transcription and protein synthesis. In this study, we report that a recently cloned coactivator of cAMP-response element-binding protein (CREB), called transducer of regulated CREB activity 1 (TORC1), contributes to this process by sensing the coincidence of calcium and cAMP signals in neurons and by converting it into a transcriptional response that leads to the synthesis of factors required for enhanced synaptic transmission. We provide evidence that TORC1 is involved in L-LTP maintenance at the Schaffer collateral-CA1 synapses in the hippocampus.
Resumo:
It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.