933 resultados para Bipolar high-voltage pulses
Resumo:
Máster Universitario en Eficiencia Energética (SIANI)
Resumo:
The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.
Resumo:
Fra i sistemi di propulsione elettrica per satelliti, il Pulsed Plasma Thruster, PPT, è quello dal design più semplice. È anche il primo sistema di propulsione elettrica utilizzato in un satellite artificiale, ossia ZOND-2 lanciato nel 1964 dall’Unione Sovietica. Tuttavia, dopo circa 50 anni di ricerca, la comprensione teorica e sperimentale di questo dispositivo rimane limitata. Questo elaborato di tesi magistrale indaga sul sottosistema di accensione del PPT, cercando di mettere in luce alcuni aspetti legati al lifetime della spark plug, SP. Tale SP, o candela, è l’attuatore del sottosistema di accensione. Questa produce una scintilla sulla sua superficie, la quale permette la realizzazione della scarica elettrica principale fra i due elettrodi del motore. Questa scarica crea una sottile parete di plasma che, per mezzo della forza elettromagnetica di Lorentz, produce la spinta del PPT. Poiché la SP si trova all’interno del catodo del motore e si affaccia nella camera di scarica, questa soffre di fenomeni di corrosione e di deposizione carbonacea proveniente dal propellente. Questi fenomeni possono limitare notevolmente il lifetime della SP. I parametri connessi alla vita operativa della SP sono numerosi. In questo elaborato si è analizzata la possibilità di utilizzare una elettronica di accensione della candela alternativa alla classica soluzione che utilizza un trasformatore. Il sottosistema di accensione classico e quello nuovo sono stati realizzati e testati, per metterne in luce le differenze ed i possibili vantaggi/svantaggi.
Resumo:
The specific energy of lithium-ion batteries (LIBs) is today 200 Wh/kg, a value not sufficient to power fully electric vehicles with a driving range of 400 km which requires a battery pack of 90 kWh. To deliver such energy the battery weight should be higher than 400 kg and the corresponding increase of vehicle mass would narrow the driving range to 280 km. Two main strategies are pursued to improve the energy of the rechargeable lithium batteries up to the transportation targets. The first is the increase of LIBs working voltage by using high-voltage cathode materials. The second is the increase of battery capacity by the development of a cell chemistry where oxygen redox reaction (ORR) occurs at the cathode and metal lithium is the anode (Li/O2 battery). This PhD work is focused on the development of high-voltage safe cathodes for LIBs, and on the investigation of the feasibility of Li/O2 battery operating with ionic liquid(IL)-based electrolytes. The use of LiMn1-xFexPO4 as high-voltage cathode material is discussed. Synthesis and electrochemical tests of three different phosphates, more safe cathode materials than transition metal oxides, are reported. The feasibility of Li/O2 battery operating in IL-based electrolytes is also discussed. Three aspects have been investigated: basic aspects of ORR, synthesis and characterization of porous carbons as positive electrode materials and study of limiting factors to the electrode capacity and cycle-life. Regarding LIBs, the findings on LiMnPO4 prepared by soluble precursors demonstrate that a good performing Mn-based olivine is viable without the coexistence of iron. Regarding Li/O2 battery, the oxygen diffusion coefficient and concentration values in different ILs were obtained. This work highlighted that the O2 mass transport limits the Li/O2 capacity at high currents; it gave indications on how to increase battery capacity by using a flow-cell and a porous carbon as cathode.
Resumo:
This dissertation will be focused on the characterization of an atmospheric pressure plasma jet source with an application oriented diagnostic approach and the description of processes supported by this plasma source. The plasma source investigated is a single electrode plasma jet. Schlieren images, optical emission spectra, temperature and heat flux profiles are analyzed to deeply investigate the fluid dynamic, the chemical composition and the thermal output of the plasma generated with a nanosecond-pulsed high voltage generator. The maximum temperature measured is about 45 °C and values close to the room temperature are reached 10 mm down the source outlet, ensuring the possibility to use the plasma jet for the treatment of thermosensitive materials, such as, for example, biological substrate or polymers. Electrospinning of polymeric solution allows the production of nanofibrous non-woven mats and the plasma pre-treatment of the solutions leads to the realization of defect free nanofibers. The use of the plasma jet allows the electrospinnability of a non-spinnable poly(L-lactic acid) (PLLA) solution, suitable for the production of biological scaffold for the wound dressing.
Resumo:
Ziel dieser Arbeit war der Aufbau und Einsatz des Atmosphärischen chemischen Ionisations-Massenspektrometers AIMS für boden- und flugzeuggetragene Messungen von salpetriger Säure (HONO). Für das Massenspektrometer wurden eine mit Gleichspannung betriebene Gasentladungsionenquelle und ein spezielles Druckregelventil entwickelt. Während der Instrumentenvergleichskampagne FIONA (Formal Intercomparisons of Observations of Nitrous Acid) an einer Atmosphären-Simulationskammer in Valencia (Spanien) wurde AIMS für HONO kalibriert und erstmals eingesetzt. In verschiedenen Experimenten wurden HONO-Mischungsverhältnisse zwischen 100 pmol/mol und 25 nmol/mol erzeugt und mit AIMS interferenzfrei gemessen. Innerhalb der Messunsicherheit von ±20% stimmen die massenspektrometrischen Messungen gut mit den Methoden der Differenziellen Optischen Absorptions-Spektrometrie und der Long Path Absorption Photometrie überein. Die Massenspektrometrie kann somit zum schnellen und sensitiven Nachweis von HONO in verschmutzter Stadtluft und in Abgasfahnen genutzt werden.rnErste flugzeuggetragene Messungen von HONO mit AIMS wurden 2011 bei der Messkampagne CONCERT (Contrail and Cirrus Experiment) auf dem DLR Forschungsflugzeug Falcon durchgeführt. Hierbei konnte eine Nachweisgrenze von < 10 pmol/mol (3σ, 1s) erreicht werden. Bei Verfolgungsflügen wurden im jungen Abgasstrahl von Passagierflugzeugen molare HONO zu Stickoxid-Verhältnisse (HONO/NO) von 2.0 bis 2.5% gemessen. HONO wird im Triebwerk durch die Reaktion von NO mit OH gebildet. Ein gemessener abnehmender Trend der HONO/NO Verhältnisse mit zunehmendem Stickoxid-Emissionsindex wurde bestätigt und weist auf eine OH Limitierung im jungen Abgasstrahl hin.rnNeben den massenspektrometrischen Messungen wurden Flugzeugmessungen der Partikelsonde Forward Scattering Spectrometer Probe FSSP-300 in jungen Kondensstreifen ausgewertet und analysiert. Aus den gemessenen Partikelgrößenverteilungen wurden Extinktions- und optische Tiefe-Verteilungen abgeleitet und für die Untersuchung verschiedener wissenschaftlicher Fragestellungen, z.B. bezüglich der Partikelform in jungen Kondensstreifen und ihrer Klimawirkung, zur Verfügung gestellt. Im Rahmen dieser Arbeit wurde der Einfluss des Flugzeug- und Triebwerktyps auf mikrophysikalische und optische Eigenschaften von Kondensstreifen untersucht. Unter ähnlichen meteorologischen Bedingungen bezüglich Feuchte, Temperatur und stabiler thermischer Schichtung wurden 2 Minuten alte Kondensstreifen der Passagierflugzeuge vom Typ A319-111, A340-311 und A380-841 verglichen. Im Rahmen der Messunsicherheit wurde keine Änderung des Effektivdurchmessers der Partikelgrößenverteilungen gefunden. Hingegen nehmen mit zunehmendem Flugzeuggewicht die Partikelanzahldichte (162 bis 235 cm-3), die Extinktion (2.1 bis 3.2 km-1), die Absinktiefe des Kondensstreifens (120 bis 290 m) und somit die optische Tiefe der Kondensstreifen (0.25 bis 0.94) zu. Der gemessene Trend wurde durch Vergleich mit zwei unabhängigen Kondensstreifen-Modellen bestätigt. Mit den Messungen wurde eine lineare Abhängigkeit der totalen Extinktion (Extinktion mal Querschnittsfläche des Kondensstreifens) vom Treibstoffverbrauch pro Flugstrecke gefunden und bestätigt.
Resumo:
A study was designed to investigate the effect of medetomidine sedation on quantitative electroencephalography (q-EEG) in healthy young and adult cats to determine objective guidelines for diagnostic EEG recordings and interpretation. Preliminary visual examination of EEG recordings revealed high-voltage low-frequency background activity. Spindles, k-complexes and vertex sharp transients characteristic of sleep or sedation were superimposed on a low background activity. Neither paroxysmal activity nor EEG burst-suppression were observed. The spectral analysis of q-EEG included four parameters, namely, relative power (%), and mean, median and peak frequency (Hz) of all four frequency bands (delta, theta, alpha and beta). The findings showed a prevalence of slow delta and theta rhythms as opposed to fast alpha and beta rhythms in both young (group A) and adult (group B) cats. A posterior gradient was reported for the theta band and an anterior gradient for the alpha and beta bands in both groups, respectively. The relative power value in group B compared to group A was significantly higher for theta, alpha and beta bands, and lower for the delta band. The mean and median frequency values in group B was significantly higher for delta, theta and beta bands and lower for the alpha band. The study has shown that a medetomidine sedation protocol for feline EEG may offer a method for investigating bio-electrical cortical activity. The use of q-EEG analysis showed a decrease in high frequency bands and increased activity of the low frequency band in healthy cats under medetomidine sedation.
Resumo:
The inhibitor cystine-knot motif identified in the structure of CSTX-1 from Cupiennius salei venom suggests that this toxin may act as a blocker of ion channels. Whole-cell patch-clamp experiments performed on cockroach neurons revealed that CSTX-1 produced a slow voltage-independent block of both mid/low- (M-LVA) and high-voltage-activated (HVA) insect Ca(v) channels. Since C. salei venom affects both insect as well as rodent species, we investigated whether Ca(v) channel currents of rat neurons are also inhibited by CSTX-1. CSTX-1 blocked rat neuronal L-type, but no other types of HVA Ca(v) channels, and failed to modulate LVA Ca(v) channel currents. Using neuroendocrine GH3 and GH4 cells, CSTX-1 produced a rapid voltage-independent block of L-type Ca(v) channel currents. The concentration-response curve was biphasic in GH4 neurons and the subnanomolar IC(50) values were at least 1000-fold lower than in GH3 cells. L-type Ca(v) channel currents of skeletal muscle myoballs and other voltage-gated ion currents of rat neurons, such as I(Na(v)) or I(K(v)) were not affected by CSTX-1. The high potency and selectivity of CSTX-1 for a subset of L-type channels in mammalian neurons may enable the toxin to be used as a molecular tool for the investigation of this family of Ca(v) channels.
Resumo:
Energy crisis and worldwide environmental problem make hydrogen a prospective energy carrier. However, storage and transportation of hydrogen in large quantities at small volume is currently not practical. Lots of materials and devices have been developed for storage hydrogen, but to today none is able to meet the DOE targets. Activated carbon has been found to be a good hydrogen adsorbent due to its high surface area. However, the weak van der Waals force between hydrogen and the adsorbent has limited the adsorption capacity. Previous studies have found that enhanced adsorption can be obtained with applied electric field. Stronger interaction between the polarized hydrogen and the charged sorbents under high voltage is considered as the reason. This study was initiated to investigate if the adsorption can be further enhanced when the activated carbon particles are separated with a dielectric coating. Dielectric TiO2 nanoparticles were first utilized. Hydrogen adsorption measurements on the TiO2-coated carbon materials, with or without an external electric field, were made. The results showed that the adsorption capacity enhancement increased with the increasing amount of TiO2 nanoparticles with an applied electric field. Since the hydrogen adsorption capacity on TiO2 particles is very low and there is no hydrogen adsorption enhancement on TiO2 particles alone when electric field is applied, the effect of dielectric coating is demonstrated. Another set of experiments investigated the behavior of hydrogen adsorption over TiO2-coated activated carbon under various electric potentials. The results revealed that the hydrogen adsorption first increased and then decreased with the increase of electric field. The improved storage was due to a stronger interaction between charged carbon surface and polarized hydrogen molecule caused by field induced polarization of TiO2 coating. When the electric field was sufficient to cause considerable ionization of hydrogen, the decrease of hydrogen adsorption occurred. The current leak detected at 3000 V was a sign of ionization of hydrogen. Experiments were also carried out to examine the hydrogen adsorption performances over activated carbon separated by other dielectric materials, MgO, ZnO and BaTiO3, respectively. For the samples partitioned with MgO and ZnO, the measurements with and without an electric field indicated negligible differences. Electric field enhanced adsorption has been observed on the activated carbon separated with BaTiO3, a material with unusually high dielectric constant. Corresponding computational calculations using Density Functional Theory have been performed on hydrogen interaction with charged TiO2 molecule as well as TiO2 molecule, coronene and TiO2-doped coronene in the presence of an electric field. The simulated results were consistent with the observations from experiments, further confirming the proposed hypotheses.
Resumo:
Large Power transformers, an aging and vulnerable part of our energy infrastructure, are at choke points in the grid and are key to reliability and security. Damage or destruction due to vandalism, misoperation, or other unexpected events is of great concern, given replacement costs upward of $2M and lead time of 12 months. Transient overvoltages can cause great damage and there is much interest in improving computer simulation models to correctly predict and avoid the consequences. EMTP (the Electromagnetic Transients Program) has been developed for computer simulation of power system transients. Component models for most equipment have been developed and benchmarked. Power transformers would appear to be simple. However, due to their nonlinear and frequency-dependent behaviors, they can be one of the most complex system components to model. It is imperative that the applied models be appropriate for the range of frequencies and excitation levels that the system experiences. Thus, transformer modeling is not a mature field and newer improved models must be made available. In this work, improved topologically-correct duality-based models are developed for three-phase autotransformers having five-legged, three-legged, and shell-form cores. The main problem in the implementation of detailed models is the lack of complete and reliable data, as no international standard suggests how to measure and calculate parameters. Therefore, parameter estimation methods are developed here to determine the parameters of a given model in cases where available information is incomplete. The transformer nameplate data is required and relative physical dimensions of the core are estimated. The models include a separate representation of each segment of the core, including hysteresis of the core, λ-i saturation characteristic, capacitive effects, and frequency dependency of winding resistance and core loss. Steady-state excitation, and de-energization and re-energization transients are simulated and compared with an earlier-developed BCTRAN-based model. Black start energization cases are also simulated as a means of model evaluation and compared with actual event records. The simulated results using the model developed here are reasonable and more correct than those of the BCTRAN-based model. Simulation accuracy is dependent on the accuracy of the equipment model and its parameters. This work is significant in that it advances existing parameter estimation methods in cases where the available data and measurements are incomplete. The accuracy of EMTP simulation for power systems including three-phase autotransformers is thus enhanced. Theoretical results obtained from this work provide a sound foundation for development of transformer parameter estimation methods using engineering optimization. In addition, it should be possible to refine which information and measurement data are necessary for complete duality-based transformer models. To further refine and develop the models and transformer parameter estimation methods developed here, iterative full-scale laboratory tests using high-voltage and high-power three-phase transformer would be helpful.
Resumo:
Polylactide (PLA) is a biodegradable polymer that has been used in particle form for drug release, due to its biocompatibility, tailorable degradation kinetics, and desirable mechanical properties. Active pharmaceutical ingredients (APIs) may be either dissolved or encapsulated within these biomaterials to create micro- or nanoparticles. Delivery of an AIP within fine particles may overcome solubility or stability issues that can result in early elimination or degradation of the AIP in a hostile biological environment. Furthermore, it is a promising method for controlling the rate of drug delivery and dosage. The goal of this project is to develop a simple and cost-effective device that allows us to produce monodisperse micro- and nanocapsules with controllable size and adjustable sheath thickness on demand. To achieve this goal, we have studied the dual-capillary electrospray and pulsed electrospray. Dual-capillary electrospray has received considerable attention in recent years due to its ability to create core-shell structures in a single-step. However, it also increases the difficulty of controlling the inner and outer particle morphology, since two simultaneous flows are required. Conventional electrospraying has been mainly conducted using direct-current (DC) voltage with little control over anything but the electrical potential. In contrast, control over the input voltage waveform (i.e. pulsing) in electrospraying offers greater control over the process variables. Poly(L-lactic acid) (PLLA) microspheres and microcapsules were successfully fabricated via pulsed-DC electrospray and dual-capillary electrospray, respectively. Core shell combinations produced include: Water/PLLA, PLLA/polyethylene glycol (PEG), and oleic Acid/PLLA. In this study, we designed a novel high-voltage pulse forming network and a set of new designs for coaxial electrospray nozzles. We also investigated the effect of the pulsed voltage characteristics (e.g. pulse frequency, pulse amplitude and pulse width) on the particle’s size and uniformity. We found that pulse frequency, pulse amplitude, pulse width, and the combinations of these factors had a statistically significant effect on the particle’s size. In addition, factors such as polymer concentration, solvent type, feed flow rate, collection method, temperature, and humidity can significantly affect the size and shape of the particles formed.
Resumo:
The Liquid Argon Time Projection Chamber (LAr TPC) technique is a promising technology for future neutrino detectors. At LHEP of the University of Bern (Switzerland), an R&D program towards large detectors are on-going. The main goal is to show the feasibility of long drift paths over many meters. Therefore, a liquid Argon TPC with 5m of drift distance was constructed. Many other aspects of the liquid Argon TPC technology are also investigated, such as a new device to generate high voltage in liquid Argon (Greinacher circuit), a recirculation filtering system and the multi-photon ionization of liquid Argon with a UV laser. Two detectors are built: a medium size prototype for specific detector technology studies, and ARGONTUBE, a 5m long device.
Resumo:
In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).
Resumo:
BACKGROUND We observed a case of conductor externalization in a Biotronik Linox lead. OBJECTIVE To investigate lead performance of the Linox and identical Sorin Vigila lead and prevalence of conductor externalization. METHODS We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n=93) with all Boston Scientific Endotak Reliance leads (ER group; n=190) and Medtronic Sprint Quattro leads (SQ group; n=202) implanted during the same period. We screened all BL group patients for conductor externalization. RESULTS We identified 8 cases of lead failures in the BL group (index case of conductor externalization; 6 cases of non-physiological high rate sensing; one case of high voltage conductor fracture). Prospective, fluoroscopic screening of 98% of all active BL group cases revealed one additional case of conductor externalization. Median follow-up was 41, 27 and 29 months for the BL group, ER group and SQ group, respectively, lead survival 94.9%, 99.2% and 100% at 3 years, and 88%, 97.5% and 100% at 5 years (p=0.038 for BL group vs. ER group, and p=0.007 for BL group vs. SQ group by the log-rank test). Younger age at implant was an independent predictor for lead failure in the BL group (adjusted HR 0.85 [95% confidence interval 0.77-0.94]; p=0.001). CONCLUSION At our center, survival of the Linox lead is 88% at five years and significantly worse than its comparators. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.
Resumo:
Moderately to sparsely nannofossiliferous Neocomian siliciclastics and rich Aptian-Albian nannofossil chalks were cored at two Leg 123 sites on the abyssal plains off northwestern Australia. At Site 765, the basal 70 m of cored section yields questionable Tithonian and Berriasian to early Hauterivian assemblages of moderate diversity containing Cruelellipsis cuvillieri, Tegumentum striatum, Speetonia colligata, and Crucibiscutum salebrosum. The overlying Hauterivianlower Aptian is represented by 140 m of sediments barren of nannofossils. Above this, the remaining 80 m of the Lower Cretaceous section has been assigned to the Rhagodiscus angustus Zone (late Aptian-early Albian in age) and the Prediscosphaera columnata Zone (middle-late Albian in age). Common species include Rhagodiscus angustus, Prediscosphaera columnata, Eprolithus floralis, Eprolithus sp., Chiastozygus litterarius, Rucinolithus irregularis, and Flabellites biforaminis. At Site 766, the Neocomian, represented by 200 m of sediment, yields C. cuvillieri, T. striatum, S. colligata, and C. salebrosum. Within the overlying Aptian-Albian sequence of 80 m, the Rhagodiscus angustus, and P. columnata zones were recognized. The paleobiogeographic patterns and implications are discussed, with special emphasis paid to the bipolar high-latitude distribution pattern of C. salebrosum in the Valanginian-Hauterivian. Biostratigraphically important species are discussed and their occurrence in the Indian Ocean is compared with one from the Tethys and Boreal realms. Two new species, Serbiscutum gaultensis and Eprolithus bettenstaedtii, are described.