991 resultados para Bidirectional AC-DC Converters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combinatorial mathematical model in tandem with a metaheuristic technique for solving transmission network expansion planning (TNEP) using an AC model associated with reactive power planning (RPP) is presented in this paper. AC-TNEP is handled through a prior DC model while additional lines as well as VAr-plants are used as reinforcements to cope with real network requirements. The solution of the reinforcement stage can be obtained by assuming all reactive demands are supplied locally to achieve a solution for AC-TNEP and by neglecting the local reactive sources, a reactive power planning (RPP) will be managed to find the minimum required reactive power sources. Binary GA as well as a real genetic algorithm (RCA) are employed as metaheuristic optimization techniques for solving this combinatorial TNEP as well as the RPP problem. High quality results related with lower investment costs through case studies on test systems show the usefulness of the proposal when working directly with the AC model in transmission network expansion planning, instead of relaxed models. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work reports dielectric measurements performed on Pb(Zr0.53Ti0.47)O3 (PZT) thin films prepared by a polymeric precursor method. The -E curves obtained for the PZT film measured at 100 kHz, under a small ac 0.2 kV/cm signal-test and a dc scan featured a typical butterfly curve. However, the -E curves obtained for PZT film under a dc scan, with a scan rate of 0.003 V/s, shows a pronounced asymmetry. The absence of a symmetric secondary peak in -E curves could be an indication of essentially 180 domain switching.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the analysis, design, simulation, and experimental results for a high frequency high Power-Factor (PF) AC (Alternate Current) voltage regulator, using a Sepic converter as power stage. The control technique employed to impose a sinusoidal input current waveform, with low Total Harmonic Distortion (THD), is the sinusoidal variable hysteresis control. The control technique was implemented in a FPGA (Field Programmable Gate Array) device, using a Hardware Description Language (VHDL). Through the use of the proposed control technique, the AC voltage regulator performs active power-factor correction, and low THD in the input current, for linear and non-linear loads, satisfying the requirements of the EEC61000-3-2 standards. Experimental results from an example prototype, designed for 300W of nominal output power, 50kHz (switching frequency), and 127Vrms of nominal input and output voltages, are presented in order to validate the proposed AC regulator. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the antiulcerogenic effect of essential oil from Baccharis dracunculifolia was evaluated using the model of acute gastric lesions induced by ethanol. The ulcerative lesion index (ULI) was significantly reduced by oral administration of the essential oil of B. dracunculifolia at doses of 50, 250 and 500 mg/kg which reduced the lesions by 42.79, 45.70 and 61.61%, respectively. The analysis of the chemical composition of the essential oil from B. dracunculifolia by GC showed that this was composed mainly of mono- and sesquiterpenes and the majority compound was nerolidol. Therefore, antiulcerogenic activity of nerolidol (50, 250 and 500 mg/kg) was investigated using ethanol-, indomethacin- and stress-induced ulcer models in rat. In the stress-induced ulcer model, a significant reduction of the ULI in animals treated with nerolidol (50, 250 and 500 mg/kg) and cimetidine (100 mg/kg) was observed, compared to the control group (p < 0.05). The percentage of inhibition of ulcer was 41.22, 51.31, 56.57 and 53.50% in groups treated with 50, 250, 500 mg/kg of nerolidol and 100 mg/kg of cimetidine (positive control), respectively. Regarding ethanol- and indomethacin-induced ulcer models, it was observed that the treatment with nerolidol (250 and 500 mg/kg) significantly reduced the ULI in comparison with the control group (p < 0.05). The dose of 50 mg/kg reduced the parameters analyzed but this was not statistically significant. In the ethanol-induced model percentage of inhibition of ulcer was 34.20, 52.63, 87.63 and 50.87% in groups treated with 50, 250, 500 mg/kg of nerolidol and 30 mg/kg of omeprazol (positive control), respectively. In indomethacin-ulcer the percentage of inhibition of ulcer was 34.69, 40.80, 51.02 and 46.93% in groups treated with 50, 250, 500 mg/kg of nerolidol and 100 mg/kg of cimetidine (positive control), respectively. The results of this study show that nerolidol displays antiulcer activity, as it significantly inhibited the formation of ulcers induced in different animal models. However, further pharmacological and toxicological investigations, to delineate the mechanism(s) of action and the toxic effects, are required to allow the use of nerolidol for the treatment of gastric ulcer. © 2007 Verlag der Zeitschrift für Naturforschung.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have established a link between the global ac response and the local flux distribution of superconducting films by combining magnetic ac susceptibility, dc magnetization, and magneto-optical measurements. The investigated samples are three Nb films: a plain specimen, used as a reference sample, and other two films patterned with square arrays of antidots. At low temperatures and small ac amplitudes of the excitation field, the Meissner screening prevents penetration of flux into the sample. Above a certain ac drive threshold, flux avalanches are triggered during the first cycle of the ac excitation. The subsequent periodic removal, inversion, and rise of flux occurs essentially through the already-created dendrites, giving rise to an ac susceptibility signal weakly dependent on the applied field. The intradendrite flux oscillation is followed, at higher values of the excitation field, by a more drastic process consisting of creation of new dendrites and antidendrites. In this more invasive regime, the ac susceptibility shows a clear field dependence. At higher temperatures a smooth penetration occurs, and the flux profile is characteristic of a critical state. We have also shown that the regime dominated by vortex avalanches can be reliably identified by ac susceptibility measurements. © 2011 American Physical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)