930 resultados para BIOMEDICAL RADIOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding how nanoparticles may affect immune responses is an essential prerequisite to developing novel clinical applications. To investigate nanoparticle-dependent outcomes on immune responses, dendritic cells (DCs) were treated with model biomedical poly(vinylalcohol)-coated super-paramagnetic iron oxide nanoparticles (PVA-SPIONs). PVA-SPIONs uptake by human monocyte-derived DCs (MDDCs) was analyzed by flow cytometry (FACS) and advanced imaging techniques. Viability, activation, function, and stimulatory capacity of MDDCs were assessed by FACS and an in vitro CD4+ T cell assay. PVA-SPION uptake was dose-dependent, decreased by lipopolysaccharide (LPS)-induced MDDC maturation at higher particle concentrations, and was inhibited by cytochalasin D pre-treatment. PVA-SPIONs did not alter surface marker expression (CD80, CD83, CD86, myeloid/plasmacytoid DC markers) or antigen-uptake, but decreased the capacity of MDDCs to process antigen, stimulate CD4+ T cells, and induce cytokines. The decreased antigen processing and CD4+ T cell stimulation capability of MDDCs following PVA-SPION treatment suggests that MDDCs may revert to a more functionally immature state following particle exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic iron oxide nanoparticles have found application as contrast agents for magnetic resonance imaging (MRI) and as switchable drug delivery vehicles. Their stabilization as colloidal carriers remains a challenge. The potential of poly(ethylene imine)-g-poly(ethylene glycol) (PEGPEI) as stabilizer for iron oxide (γ-Fe₂O₃) nanoparticles was studied in comparison to branched poly(ethylene imine) (PEI). Carrier systems consisting of γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were prepared and characterized regarding their physicochemical properties including magnetic resonance relaxometry. Colloidal stability of the formulations was tested in several media and cytotoxic effects in adenocarcinomic epithelial cells were investigated. Synthesized γ-Fe₂O₃ cores showed superparamagnetism and high degree of crystallinity. Diameters of polymer-coated nanoparticles γ-Fe₂O₃-PEI and γ-Fe₂O₃-PEGPEI were found to be 38.7 ± 1.0 nm and 40.4 ± 1.6 nm, respectively. No aggregation tendency was observable for γ-Fe₂O₃-PEGPEI over 12 h even in high ionic strength media. Furthermore, IC₅₀ values were significantly increased by more than 10-fold when compared to γ-Fe₂O₃-PEI. Formulations exhibited r₂ relaxivities of high numerical value, namely around 160 mM⁻¹ s⁻¹. In summary, novel carrier systems composed of γ-Fe₂O₃-PEGPEI meet key quality requirements rendering them promising for biomedical applications, e.g. as MRI contrast agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lodox Statscan provides high-speed, high-quality, low radiation, full body imaging in a single scan, combined with three-dimensional reconstructive and zooming functionality. Several trauma centres have incorporated it into their advanced trauma life support protocol. This review gives a brief overview of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the application of full-body radiography to nontraumatic emergency situations. The Lodox Statscan is an X-ray machine capable of imaging the entire body in 13 seconds using linear slit scanning radiography (LSSR). Nontraumatic emergency applications in ventriculoperitoneal (VP) shunt visualisation, emergency room arteriography (ERA), detection of foreign bodies, and paediatric emergency imaging are presented. Reports show that the fast, full-body, and low-dose scanning capabilities of the Lodox system make it well suited to these applications, with the same or better image quality, faster processing times, and lower dose to patients. In particular, the large format scans allowing visualisation of a greater area of anatomy make it well suited to VP shunt monitoring, ERA, and the detection of foreign bodies. Whilst more studies are required, it can be concluded that the Lodox Statscan has the potential for widespread use in these and other nontraumatic emergency radiology applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background It is commonly assumed that indigenous medical systems remain strong in developing countries because biomedicine is physically inaccessible or financially not affordable. This paper compares the health-seeking behavior of households from rural Andean communities at a Peruvian and a Bolivian study site. The main research question was whether the increased presence of biomedicine led to a displacement of Andean indigenous medical practices or to coexistence of the two healing traditions. Methodology Open-ended interviews and free listing exercises were conducted between June 2006 and December 2008 with 18 households at each study site. Qualitative identification of households’ therapeutic strategies and use of remedies was carried out by means of content analysis of interview transcriptions and inductive interference. Furthermore, a quantitative assessment of the incidence of culture-bound illnesses in local ethnobiological inventories was performed. Results Our findings indicate that the health-seeking behavior of the Andean households in this study is independent of the degree of availability of biomedical facilities in terms of quality of services provided, physical accessibility, and financial affordability, except for specific practices such as childbirth. Preference for natural remedies over pharmaceuticals coexists with biomedical healthcare that is both accessible and affordable. Furthermore, our results show that greater access to biomedicine does not lead to less prevalence of Andean indigenous medical knowledge, as represented by the levels of knowledge about culture-bound illnesses. Conclusions The take-home lesson for health policy-makers from this study is that the main obstacle to use of biomedicine in resource-poor rural areas might not be infrastructural or economic alone. Rather, it may lie in lack of sufficient recognition by biomedical practitioners of the value and importance of indigenous medical systems. We propose that the implementation of health care in indigenous communities be designed as a process of joint development of complementary knowledge and practices from indigenous and biomedical health traditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Randomized controlled trials (RCTs) are the best tool to evaluate the effectiveness of clinical interventions. The Consolidated Standards for Reporting Trials (CONSORT) statement was introduced in 1996 to improve reporting of RCTs. We aimed to determine the extent of ambiguity and reporting quality as assessed by adherence to the CONSORT statement in published reports of RCTs involving patients with Hodgkin lymphoma from 1966 through 2002. METHODS: We analyzed 242 published full-text reports of RCTs in patients with Hodgkin lymphoma. Quality of reporting was assessed using a 14-item questionnaire based on the CONSORT checklist. Reporting was studied in two pre-CONSORT periods (1966-1988 and 1989-1995) and one post-CONSORT period (1996-2002). RESULTS: Only six of the 14 items were addressed in 75% or more of the studies in all three time periods. Most items that are necessary to assess the methodologic quality of a study were reported by fewer than 20% of the studies. Improvements over time were seen for some items, including the description of statistics methods used, reporting of primary research outcomes, performance of power calculations, method of randomization and concealment allocation, and having performed intention-to-treat analysis. CONCLUSIONS: Despite recent improvements, reporting levels of CONSORT items in RCTs involving patients with Hodgkin lymphoma remain unsatisfactory. Further concerted action by journal editors, learned societies, and medical schools is necessary to make authors even more aware of the need to improve the reporting RCTs in medical journals to allow assessment of validity of published clinical research.