923 resultados para Aortic Input Impedance
Resumo:
The paper uses a regional input-output (IO) framework and data derived on waste generation by industry to examine regional accountability for waste generation. In addition to estimating a series of industry output-waste coefficients, the paper considers two methods for waste attribution but focuses first on one (trade endogenised linear attribution system (TELAS)) that permits a greater focus on private and public final consumption as the main exogenous driver of waste generation. Second, the paper uses a domestic technology assumption (DTA) to consider a regional ‘waste footprint’ where local consumption requirements are assumed to be met through domestic production.
Resumo:
This paper describes how the education sector of the Scottish Input-Output tables is disaggregated to identify a separate sector for each of Scotland’s twenty Higher Education Institutions (HEIs). The process draws on accounting and survey data to accurately determine the incomes and expenditures of each institution. In particular we emphasise determining the HEIs incomes source of origin to inform their treatment, as endogenous or exogenous, in subsequent analyses. The HEI-disaggregated Input- Output table provides a useful descriptive snapshot of the Scottish economy and the role of HEIs within it for a particular year, 2006. The table can be used to derive multipliers and conduct various impact studies of each institution or the sector as a whole. The table is furthermore useful to calibrate other multi-sectoral, HEI disaggregated models of regional economies, including Social Accounting Matrix (SAM) and computable general equilibrium (CGE) models.
Resumo:
This paper describes how the education sector of the Welsh Input-Output tables is disaggregated to identify a separate sector for each of Wales’s twelve Higher Education Institutions (HEIs). The process draws on accounting and survey data to accurately determine the incomes and expenditures of each institution. In particular we emphasise determining the HEIs incomes source of origin to inform their treatment, as endogenous or exogenous, in subsequent analyses. The HEI-disaggregated Input-Output table provides a useful descriptive snapshot of the Welsh economy and the role of HEIs within it for a particular year, 2006. The table can be used to derive multipliers and conduct various impact studies of each institution or the sector as a whole. The table is furthermore useful to calibrate other multi-sectoral, HEI-disaggregated models of regional economies, including Social Accounting Matrix (SAM) and computable general equilibrium (CGE) models.
Resumo:
This paper describes how the education sector of an Input-Output table for Northern Ireland is disaggregated to identify a separate sector for each of the four Northern Irish Higher Education Institutions (HEIs). The process draws on accounting and survey data to accurately determine the incomes and expenditures of each institution. In particular we emphasise determining the HEIs incomes source of origin to inform their treatment, as endogenous or exogenous, in subsequent analyses. The HEI-disaggregated Input-Output table provides a useful descriptive snapshot of the Northern Irish economy and the role of HEIs within it for a particular year, 2006. The table can be used to derive multipliers and conduct various impact studies of each institution or the sector as a whole. The table is furthermore useful to calibrate other multisectoral, HEI-disaggregated models of regional economies, including Social Accounting Matrix (SAM) and computable general equilibrium (CGE) models.
Resumo:
This paper disaggregates a UK Input-Output (IO) table for 2004 based on household income quintiles from published survey data. In addition to the Input-Output disaggregation, the household components of a UK Income Expenditure (I-E) account used to inform a Social Accounting Matrix (SAM),have also been disaggregated by household income quintile. The focus of this paper is on household expenditure on the UK energy sector.
Resumo:
It is a well-established fact in the literature on simulating Input-Output tables that mechanical methods for estimating intermediate trade lead to biased results where cross-hauling is underestimated and Type-I multipliers are overstated. Repeated findings to this effect have led to a primary emphasis on advocating the accurate estimation of intermediate trade flows. This paper reviews previous research and argues for a qualification of the consensus view: When simulating IO tables, construction approaches need to consider spill-over effects driven by wage and consumption flows. In particular, for the case of metropolitan economies, wage and consumption flows are important if accurate Type-II multipliers are to be obtained. This is demonstrated by constructing an interregional Input-Output table, which captures interdependencies between a city and its commuter belt, nested within the wider regional economy. In addition to identifying interdependencies caused by interregional intermediate purchases, data on subregional household incomes and commuter flows are used to identify interdependencies from wage payments and household consumption. The construction of the table is varied around a range of assumptions on intermediate trade and household consumption to capture the sensitivity of multipliers.
Resumo:
En el presente trabajo se desarrolla un estudio de las emisiones de CH4 relacionadas con el sector agroalimentario catalán a través de un análisis alternativo, o al menos complementario, de subsistemas input-output. Una herramienta de gran utilidad para estudiar la estructura productiva de los diferentes sectores que componen una economía. La aplicación de esta técnica permite las descomposición del subsistema en distintos efectos en función de los vínculos intersectoriales existentes con el conjunto de las ramas productivas de la economía, dentro y fuera del subsistema. De los resultados obtenidos destaca la importancia de las relaciones intrasectoriales del subsistema agroalimentario, que muestra una relevante autonomía en cuanto a este tipo de emisiones respecto al resto de la economía. Esta característica orienta el tipo de políticas medioambientales a implementar con el objetivo de reducir el impacto atmosférico de dicha actividad.
Resumo:
OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.
Resumo:
BACKGROUND: Little information is available on the validity of simple and indirect body-composition methods in non-Western populations. Equations for predicting body composition are population-specific, and body composition differs between blacks and whites. OBJECTIVE: We tested the hypothesis that the validity of equations for predicting total body water (TBW) from bioelectrical impedance analysis measurements is likely to depend on the racial background of the group from which the equations were derived. DESIGN: The hypothesis was tested by comparing, in 36 African women, TBW values measured by deuterium dilution with those predicted by 23 equations developed in white, African American, or African subjects. These cross-validations in our African sample were also compared, whenever possible, with results from other studies in black subjects. RESULTS: Errors in predicting TBW showed acceptable values (1.3-1.9 kg) in all cases, whereas a large range of bias (0.2-6.1 kg) was observed independently of the ethnic origin of the sample from which the equations were derived. Three equations (2 from whites and 1 from blacks) showed nonsignificant bias and could be used in Africans. In all other cases, we observed either an overestimation or underestimation of TBW with variable bias values, regardless of racial background, yielding no clear trend for validity as a function of ethnic origin. CONCLUSIONS: The findings of this cross-validation study emphasize the need for further fundamental research to explore the causes of the poor validity of TBW prediction equations across populations rather than the need to develop new prediction equations for use in Africa.
Resumo:
BACKGROUND: Reconstruction of the central aortic pressure wave from the noninvasive recording of the radial pulse with applanation tonometry has become a standard tool in the field of hypertension. It is not presently known whether recording the radial pulse on the dominant or the nondominant side has any effect on such reconstruction. METHOD: We carried out radial applanation tonometry on both forearms in young, healthy, male volunteers, who were either sedentary (n = 11) or high-level tennis players (n = 10). The purpose of including tennis players was to investigate individuals with extreme asymmetry between the dominant and nondominant upper limb. RESULTS: In the sedentary individuals, forearm circumference and handgrip strength were slightly larger on the dominant (mean +/- SD respectively 27.9 +/- 1.5 cm and 53.8 +/- 10 kg) than on nondominant side (27.3 +/- 1.6 cm, P < 0.001 vs. dominant, and 52.1 +/- 11 kg, P = NS). In the tennis players, differences between sides were more conspicuous (forearm circumference: dominant 28.0 +/- 1.7 cm nondominant 26.4 +/- 1.5 cm, P < 0.001; handgrip strength 61.4 +/- 10.8 vs. 53.4 +/- 9.7 kg, P < 0.001). We found that in both sedentary individuals and tennis players, the radial pulse had identical shape on both sides and, consequently, the reconstructed central aortic pressure waveforms, as well as derived indices of central pulsatility, were not dependent on the side where applanation tonometry was carried out. CONCLUSION: Evidence from individuals with maximal asymmetry of dominant vs. nondominant upper limb indicates that laterality of measurement is not a methodological issue for central pulse wave analysis carried out with radial applanation tonometry.
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.
Resumo:
BACKGROUND: To evaluate the effect of statins on the annual expansion rate (ER) of small infrarenal abdominal aortic aneurysms (AAA). PATIENTS AND METHODS: All patients under regular surveillance for small AAA between January 2000 and September 2007, in the Department of Angiology, Lausanne University Hospital, were included. Inclusion criteria were baseline abdominal aortic diameter between 25 and 55 mm, at least two measurements of AAA diameter and a minimum follow up of 6 months. Patients with Marfan disease, infectious or inflammatory AAA, and patients with prior AAA repair were excluded. The influence of statin use and other factors on ER were examined by bivariate and multivariate analysis. RESULTS: Among 589 patients who underwent an abdominal aorta evaluation, 94 patients (89 % men, mean age 69.1 years) were finally included in the analysis. Baseline AAA size was 39.9 ± 7.7 mm (mean±SE) and 48.7 ± 8.4 mm at end of follow-up. Patients had a regular aneurysm size assessment during 38.5 ± 27.7 months. Mean ER was 3.59 mm/y (± 2.81). The 50 patients who were treated with statin during the study period had a lower ER compared to the 44 controls (2.91 vs 4.37 mm/year, p = 0.01). CONCLUSIONS: This study confirms the considerable individual variations in the AAA expansion rate, and emphasizes the need for regular aortic diameter assessments. In this study, patients treated with statin demonstrate a significant decrease in the ER compared to controls. This finding need to be evaluated in prospective interventional studies powered to demonstrate the potential benefit of statin treatment.