321 resultados para Anisotropías magnéticas]
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
The relationship between the microstructure and the magnetic properties of soft magnetic materials, have been studied by different researchers who seek to employ electrical systems, increasing their life span and reduce their energy consumption. Following this same line the Brazilian Synchrotron Light Laboratory developed a new synchrotron light source, the Sirius, where magnetic materials with high magnetic permeability values are being studied for use in accelerator dipoles. The low carbon steel is a ferromagnetic material that has a great relationship between cost and magnetic permeability. Aiming to raise the values of permeability of the material, heat treatments were done and evaluated the magnetic properties, microstructure and mechanical properties to correlate them. It was noted that the thermal annealing were the most effective, and the annealing performed with a small time threshold, which only phenomenon observed was the primary recrystallisation, was the most elevated values of magnetic permeability of the material, due to the average grain size ideal achieved. The heat treatments do not guide the magnetic domains of the material and not influence the mechanical properties of the material due to lack of carbon in the microstructure. The annealing treatments were shown to be an alternative to raising the values of the magnetic permeability of the material and facilitate the implementation of ultra low carbon steel in the dipoles of Sirius
Resumo:
Chitosan is a natural biodegradable polymer with great potential for pharmaceutical applications due to its biocompatibility, high charge density , nontoxicity and mucoadhesion. Gel formation can be obtained by the interactions of chitosans with low molecular counterions such as polyphosphates, sulphates and crosslinking with glutaraldehyde. This gelling property of chitosan allows a wide range of applications such as coating of pharmaceuticals and food products, gel entrapment of biochemicals, whole cells, microorganisms and algae. One of its main applications is the synthesis of microspheres for coating of pharmaceuticals , magnetic particles an other substances. In such a way, we can build targeted drug delivery systems. In the present work, we applied the method of spraying and coagulation. The resulting microspheres, then, were characterized by optical microscopy
Resumo:
This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)
Resumo:
O câncer é uma patologia crescente entre a população atual e segundo a Organização Mundial da Saúde (OMS) está entre as principais causa de morte mundialmente. A relevância do perfil epidemiológico dessa doença desperta interesse em desenvolver materiais que forneçam qualidade de diagnóstico e tratamento. Na busca pela qualidade da saúde, o desenvolvimento de materiais que possam liberar fármacos de forma controlada e em um sítio alvo, tem se tornado cada vez mais intensa, pois estes materiais podem diminuir os efeitos colaterais além de aumentar a porcentagem do medicamento em ação direta com o sítio alvo. Neste contexto, materiais poliméricos híbridos orgânico-inorgânicos do tipo ureasil-poliéter que são biocompatíveis, transparentes e flexíveis permitem a incorporação de uma série de compostos, dentre os quais, nanopartículas e fármacos. Com base nestes argumentos, neste trabalho foi desenvolvido dispositivo de liberação controlada de fármacos formado por materiais poliméricos ureasil-poliéter contendo nanopartículas de ZnO dopadas com cobalto. A conjugação destes diferentes materiais teve como objetivo conferir as propriedades individuais de cada componente no mesmo material: o cobalto devido as suas propriedades magnéticas pode guiar o dispositivo de liberação de fármaco até o órgão doente; o ZnO devido às propriedades luminescentes permite monitorar a posição do dispositivo dentro do corpo humano.
Resumo:
Oral administration is widely accepted route for drug delivery and solid dosage forms are commonly employed. The variation of absorption profiles along the human gastrointestinal tract (GIT) and the ability to target drugs by adequate dosage forms to distinct sites is the challenge in the pharmaceutical development of solid dosage forms. AC Biosusceptometry (ACB) is a technique that deserves consideration due to its features, accuracy of results and versatility. The purpose of this work was to evaluate, by employing the AC Biosusceptometer, the rate of swelling of systems matrices consisting of hydrophilic polymer (hydroxypropyl methyl cellulose) and magnetic material. Matrices tablets were evaluated in vitro to a more detailed analysis of kinetics of swelling, in addition to the study and application of mathematical models to correlate the magnetic area variation and the water uptake. All the procedures for qualitative and quantitative analysis of digital signals as well as the magnetic images processing were performed in MatLab® (Mathworks Inc.). ACB technique proved to be useful towards estimating the swelling properties of hydrophilic matrices in vitro, showing a promising capacity for further analyses involving dissolution test and in vivo studies, supporting their innovative potential pharmaceutical applications
Resumo:
The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)
Resumo:
The gastrointestinal tract is the main route of nutrients absorption and drugs delivery. Is important to know the parameters related to the tract, like gastric emptying and gastrointestinal transit, in order to better understand the behavior of different kind of meals or drugs passing through the GIT. Many techniques are used to study these parameters, such as manometry, scintigraphy, phenol red, activated charcoal and carbon-13 reading. However, these methods use radiation, are invasive and require animal sacrifice. As an alternative proposal, the Alternate Current Biosusceptometry (ACB), a magnetic technique, has proved to be effective for these studies with small animals, in a noninvasive way, low cost, radiation free and avoiding the animal death. Associating the ACB to magnetic micro or nanoparticles used as tracers, it is possible to observe the meal behavior inside of the GIT. Focusing meanly on liquid meals digestion, this paper had the objective to evaluate the efficiency of the ACB technique in gastric emptying and gastrointestinal transit evaluation of liquid meals in rats. To perform the experiments, magnetic nanoparticles (ferrite, MgFe2O4) were used on a 1,5 ml solution introduced by gavage on similar weight and age rats. The sensor made by 2 pairs of coils, capable of generating and detecting magnetic fields, creates a field on the interest place and when this field is in contact with the marked meal, it changes, resulting on a variation of the measured voltage. The voltage variation is analyzed and is obtained a particle concentration on the interest region. The results showed that is possible to apply the ACB technique on the GIT evaluation of liquid particles digestion, gastric emptying and meal cecum arrival time curves were obtained and from that, is possible to observe a pattern of gastrointestinal transit. Both mean process time values were acquired, proving the technique capability of ...
Resumo:
The increasing demand for electro-electronic devices, with high performance and multi-functional and the rapid advances of the nanotechnology require the development of new methods and techniques for the production and characterization of nanostructure materials and phenomenological models to describe/to predict some of its properties. The demand for multifunctionality requires, at least, new materials, that can integrate ferroelectric and magnetic properties of high technological interest. Inside of this context, multiferroics material can be considered suitable to integrate two or more physical properties of high technological interest. It can also provides new challenges in the processes of synthesis of new materials, and development of new devices with controlling and simulation of its physical properties and modeling. For this Calcium (Ca)-doped bismuth ferrite (BiFeO3) thin films prepared by using the polymeric precursor method (PPM) were characterized by X-ray diffraction (XRD), field emission gun scanning electron microscopy (FEG-SEM), transmission electron microscopy (TEM), polarization and piezoelectric measurements.In order to study the behavior and determine which are the most important parameters to achieve the optimal property to be applied to a multiferroic materials
Resumo:
This paper reports on the effect of the substitution of Fe3+ for Cr3+ ions in the spinel lattice of the powders was investigated. Nickel ferrite powders with a NiFe2-xCrxO4 nominal composition (x = 0.0; 0.5; 1.0 and 1.5 mol of the chromium) were synthesized by combustion reaction using urea as fuel. The powders resulting were characterized by XRD, nitrogen adsorption by BET, SEM and Mössbauer spectroscopy (57Fe Mössbauer spectra). The results show that the substitution of the Fe3+ for Cr3+ions increased the crystalline degree of the phase, reduced the superficial area and consequently increased the particle size. The Mössbauer spectra of the samples also confirm the distribution of the particles size by the magnetic properties. Analyze of the spectra Mössbauer gives an estimate of the superparamagnetic and ferromagnetic particles behavior in each sample for several chromium concentrations.
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ