996 resultados para Ae


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four methods to control the smooth cordgrass Spartina (Spartina alterniflora) and the footwear worn by treatment personnelat several sites in Willapa Bay, Washington were evaluatedto determine the non-target impacts to eelgrass (Zostera japonica). Clone-sized infestations of Spartina were treated bymowing or a single hand-spray application of Rodeo® formulatedat 480 g L-1acid equivalence (ae) of the isopropylaminesalt of glyphosate (Monsanto Agricultural Co., St. Louis, MO;currently Dow AgroSciences, Indianapolis, IN) with the nonionic surfactant LI 700® (2% v/v) or a combination of mowing and hand spraying. An aerial application of Rodeo® with X-77 Spreader® (0.13% v/v) to a 2-ha meadow was also investigated. Monitoring consisted of measuring eelgrass shoot densities and percent cover pre-treatment and 1-yr post-treatment. Impacts to eelgrass adjacent to treated clones were determined 1 m from the clones and compared to a control 5-m away. Impacts from footwear were assessed at 5 equidistant intervals along a 10-m transect on mudflat and an untreated control transect at each of the three clone treatment sites. Impacts from the aerial application were determined by comparing shoot densities and percent cover 1, 3 and 10 m from the edge of the treated Spartina meadow to that at comparable distances from an untreated meadow. Methods utilized to control Spartina clones did not impact surrounding eelgrass at two of three sites. Decreases in shoot densities observed at the third site were consistent across treatments. Most impacts to eelgrass from the footwear worn by treatment personnel were negligible and those that were significant were limited to soft mud substrate. The aerial application of the herbicide was associated with reductions in eelgrass (shoot density and percent cover) at two of the three sampling distances, but reductions on the control plot were greater. We conclude that the unchecked spread of Spartina is a far greater threat to the survival and health of eelgrass than that from any of the control measures we studied. The basis for evaluating control measures for Spartina should be efficacy and logistical constraints and not impacts to eelgrass. PDF is 7 pages.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies were conducted to evaluate whether the herbicide imazapyr or a combination of imazapyr and fluridone could be used effectively to control torpedograss ( Panicum repens L.), an exotic perennial plant that has replaced more than 6,000 ha of native vegetation and degraded quality wildlife habitat in Lake Okeechobee, Florida. Torpedograss was controlled for more than one year in some areas following a single aerial treatment using 0.56, 0.84, or 1.12 kg acid equivalents (ae) imazapyr/ha. Combining imazapyr and fluridone did not increase the level of torpedograss control. In areas where plant biomass was reduced by fire prior to being treated with 0.84 or 1.12 kg ae imazapyr/ha, torpedograss was controlled for more than two years and native plant species, including duck potato ( Sagittaria lancifolia L.) and pickerelweed ( Pontederia cordata L.) became the dominant vegetation in less than one year. Although torpedograss was controlled in some areas, little or no long-term control was observed at 16 of the 26 treatment locations. To reduce the uncertainty associated with predicting long-term treatment affects, additional studies are needed to determine whether environmental factors such as periphyton mats, plant thatch, hydroperiod and water depth affect treatment efficacy. , he

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Northridge earthquake of January 17, 1994, highlighted the two previously known problems of premature fracturing of connections and the damaging capabilities of near-source ground motion pulses. Large ground motions had not been experienced in a city with tall steel moment-frame buildings before. Some steel buildings exhibited fracture of welded connections or other types of structural degradation.

A sophisticated three-dimensional nonlinear inelastic program is developed that can accurately model many nonlinear properties commonly ignored or approximated in other programs. The program can assess and predict severely inelastic response of steel buildings due to strong ground motions, including collapse.

Three-dimensional fiber and segment discretization of elements is presented in this work. This element and its two-dimensional counterpart are capable of modeling various geometric and material nonlinearities such as moment amplification, spread of plasticity and connection fracture. In addition to introducing a three-dimensional element discretization, this work presents three-dimensional constraints that limit the number of equations required to solve various three-dimensional problems consisting of intersecting planar frames.

Two buildings damaged in the Northridge earthquake are investigated to verify the ability of the program to match the level of response and the extent and location of damage measured. The program is used to predict response of larger near-source ground motions using the properties determined from the matched response.

A third building is studied to assess three-dimensional effects on a realistic irregular building in the inelastic range of response considering earthquake directivity. Damage levels are observed to be significantly affected by directivity and torsional response.

Several strong recorded ground motions clearly exceed code-based levels. Properly designed buildings can have drifts exceeding code specified levels due to these ground motions. The strongest ground motions caused collapse if fracture was included in the model. Near-source ground displacement pulses can cause columns to yield prior to weaker-designed beams. Damage in tall buildings correlates better with peak-to-peak displacements than with peak-to-peak accelerations.

Dynamic response of tall buildings shows that higher mode response can cause more damage than first mode response. Leaking of energy between modes in conjunction with damage can cause torsional behavior that is not anticipated.

Various response parameters are used for all three buildings to determine what correlations can be made for inelastic building response. Damage levels can be dramatically different based on the inelastic model used. Damage does not correlate well with several common response parameters.

Realistic modeling of material properties and structural behavior is of great value for understanding the performance of tall buildings due to earthquake excitations.