986 resultados para ASSISTED THORACIC-SURGERY
Resumo:
OBJECTIVES: During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even inadequate end-organ perfusion. The goal of this study was to reproduce venous collapse in the flow bench. METHODS: In accordance with literature for venous anatomy, a caval tree system is designed (polyethylene, thickness 0.061 mm), which receives venous inflow from nine afferent veins. With water as medium and a preload of 4.4 mmHg, the system has an outflow of 4500 ml/min (Scenario A). After the insertion of a percutaneous venous cannula (23-Fr), the venous model is continuously served by the afferent branches in a venous test bench and venous drainage is augmented with a centrifugal pump (Scenario B). RESULTS: With gravity drainage (siphon: A), spontaneously reversible atrial chatter can be generated in reproducible fashion. Slight reduction in the outflow diameter allows for generation of continuous flow. With augmentation (B), irreversible collapse of the artificial vena cava occurs in reproducible fashion at a given pump speed of 2300 ± 50 RPM and a pump inlet pressure of -112 mmHg. Furthermore, bubbles form at the cannula tip despite the fact that the entire system is immersed in water and air from the environment cannot enter the system. This phenomenon is also known as cavitation and should be avoided because of local damage of both formed blood elements and endothelium, as well embolization. CONCLUSIONS: This caval model provides a realistic picture for the limitations of flow due to spontaneously reversible atrial chatter vs irreversible venous collapse for a given negative pressure during CPB. Temporary interruption of negative pressure in the venous line can allow for recovery of venous drainage. This know-how can be used not only for testing different cannula designs, but also for further optimizing perfusion strategies.
Resumo:
BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.
Resumo:
OBJECTIVES: The reconstruction of the right ventricular outflow tract (RVOT) with valved conduits remains a challenge. The reoperation rate at 5 years can be as high as 25% and depends on age, type of conduit, conduit diameter and principal heart malformation. The aim of this study is to provide a bench model with computer fluid dynamics to analyse the haemodynamics of the RVOT, pulmonary artery, its bifurcation, and left and right pulmonary arteries that in the future may serve as a tool for analysis and prediction of outcome following RVOT reconstruction. METHODS: Pressure, flow and diameter at the RVOT, pulmonary artery, bifurcation of the pulmonary artery, and left and right pulmonary arteries were measured in five normal pigs with a mean weight of 24.6 ± 0.89 kg. Data obtained were used for a 3D computer fluid-dynamics simulation of flow conditions, focusing on the pressure, flow and shear stress profile of the pulmonary trunk to the level of the left and right pulmonary arteries. RESULTS: Three inlet steady flow profiles were obtained at 0.2, 0.29 and 0.36 m/s that correspond to the flow rates of 1.5, 2.0 and 2.5 l/min flow at the RVOT. The flow velocity profile was constant at the RVOT down to the bifurcation and decreased at the left and right pulmonary arteries. In all three inlet velocity profiles, low sheer stress and low-velocity areas were detected along the left wall of the pulmonary artery, at the pulmonary artery bifurcation and at the ostia of both pulmonary arteries. CONCLUSIONS: This computed fluid real-time model provides us with a realistic picture of fluid dynamics in the pulmonary tract area. Deep shear stress areas correspond to a turbulent flow profile that is a predictive factor for the development of vessel wall arteriosclerosis. We believe that this bench model may be a useful tool for further evaluation of RVOT pathology following surgical reconstructions.
Resumo:
Background. We assessed end-diastolic right ventricular (RV) dimensions and left ventricular (LV) ejection fraction by use of intraoperative transesophageal echocardiography before and after surgical correction of pectus excavatum in adults. Methods. A prospective study was conducted including 17 patients undergoing surgical correction of pectus excavatum according to the technique of Ravitch-Shamberger between 1999 and 2004. Intraoperative transesophageal echocardiography was performed under general anesthesia before and after surgery to assess end-diastolic RV dimensions and LV ejection fraction. The end-diastolic RV diameter and area were measured in four-chamber and RV inflow-outflow view, and the RV volume was calculated from these data. The LV was assessed by transgastric short-axis view, and its ejection fraction was calculated by use of the Teichholz formula. Results. The end-diastolic RV diameter, area, and volume all significantly increased after surgery (mean values +/- SD, respectively: 2.4 +/- 0.8 cm versus 3.0 +/- 0.9 cm, p < 0.001; 12.5 +/- 5.2 cm(2) versus 18.4 +/- 7.5 cm(2), p < 0.001; and 21.7 +/- 11.7 mL versus 40.8 +/- 23 mL, p < 0.001). The LV ejection fraction also significantly increased after surgery (58.4% +/- 15% versus 66.2% +/- 6%, p < 0.001). Conclusions. Surgical correction of pectus excavatum according to Ravitch-Shamberger technique results in a significant increase in end-diastolic RV dimensions and a significantly increased LV ejection fraction. (Ann Thorac Surg 2010; 89: 240-4) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
OBJECTIVE: Comparison of prospectively treated patients with neoadjuvant cisplatin-based chemotherapy vs radiochemotherapy followed by resection for mediastinoscopically proven stage III N2 non-small cell lung cancer with respect to postoperative morbidity, pathological nodal downstaging, overall and disease-free survival, and site of recurrence. METHODS: Eighty-two patients were enrolled between January 1994 to June 2003, 36 had cisplatin and doxetacel-based chemotherapy (group I) and 46 cisplatin-based radiochemotherapy up to 44 Gy (group II), either as sequential (25 patients) or concomitant (21 patients) treatment. All patients had evaluation of absence of distant metastases by bone scintigraphy, thoracoabdominal CT scan or PET scan, and brain MRI, and all underwent pre-induction mediastinoscopy, resection and mediastinal lymph node dissection by the same surgeon. RESULTS: Group I and II comprised T1/2 tumors in 47 and 28%, T3 tumors in 45 and 41%, and T4 tumors in 8 and 31% of the patients, respectively (P=0.03). There was a similar distribution of the extent of resection (lobectomy, sleeve lobectomy, left and right pneumonectomy) in both groups (P=0.9). Group I and II revealed a postoperative 90-d mortality of 3 and 4% (P=0.6), a R0-resection rate of 92 and 94% (P=0.9), and a pathological mediastinal downstaging in 61 and 78% of the patients (P<0.01), respectively. 5y-overall survival and disease-free survival of all patients were 40 and 36%, respectively, without significant difference between T1-3 and T4 tumors. There was no significant difference in overall survival rate in either induction regimens, however, radiochemotherapy was associated with a longer disease-free survival than chemotherapy (P=0.04). There was no significant difference between concurrent vs sequential radiochemotherapy with respect to postoperative morbidity, resectability, pathological nodal downstaging, survival and disease-free survival. CONCLUSIONS: Neoadjuvant cisplatin-based radiochemotherapy was associated with a similar postoperative mortality, an increased pathological nodal downstaging and a better disease-free survival as compared to cisplatin doxetacel-based chemotherapy in patients with stage III (N2) NSCLC although a higher number of T4 tumors were admitted to radiochemotherapy.
Resumo:
Background: Recent data have suggested that a population of CD4+ CD25high T cells, phenotypically characterized by the expression of CD45RO and CD127, is significantly expanded in stable liver and kidney transplant recipients and represents alloreactive T cells. We analyzed this putative new alloreactive cellular marker in various groups of kidney transplant recipients. Patients and methods: Flow cytometry was used to analyze the expression of CD25, CD45RO and CD127 on peripheral CD4+ T cells. Of 73 kidney recipients, 59 had a stable graft function under standard immunosuppressive therapy (IS), 5 had biopsy-proven chronic humoral rejection (CHR), 8 were stable under minimal IS and one was an operationally "tolerant" patient who had discontinued IS for more than 3 years. Sixty-six healthy subjects (HS) were studied as controls. Results: Overall, the alloreactive T cell population was found to be significantly increased in the 73 kidney recipients (mean ± SE: 15.03 ± 1.04% of CD4+ CD25high T cells) compared to HS (5.93 ± 0.39%) (p <0.001). In the 5 patients with CHR, this population was highly expanded (31.33 ± 4.16%), whereas it was comparable to HS in the 8 stable recipients receiving minimal IS (6.12 ± 0.86%), in 4 patients who had been switched to sirolimus (4.21 ± 0.53%) as well as in the unique "tolerant" recipient (4.69%). Intermediate levels (15.84 ± 0.93%) were found in the 55 recipients with stable graft function on standard CNI-based IS. Regulatory T cells, defined as CD4+ CD25high FoxP3+ CD127low, were found to be significantly reduced in all recipients except in those with minimal or no IS, and this reduction was particularly striking in recipients with CHR. Conclusion: After kidney transplantation, an alloreactive T cell population was found to be significantly expanded and it correlates with the clinical status of the recipients. Interestingly, in stable patients with minimal (or no) IS as well as in patients on sirolimus, alloreactive T cells were comparable the healthy controls. Measuring circulating CD4+ CD25high CD45RO+ CD127high T cells may become a useful monitoring tool after transplantation.
Resumo:
Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.
Resumo:
BACKGROUND: Clinical studies suggest that transmyocardial laser revascularization may improve regional blood flow of the subendocardial layer. The vascular growth pattern of laser channels was analyzed. METHODS: Twenty pigs were randomized to undergo ligation of left marginal arteries (n = 5), to undergo transmyocardial laser revascularization of the left lateral wall (n = 5), to undergo both procedures (n = 5) or to a control group (n = 5). All the animals were sacrificed after 1 month. Computed morphometric analysis of vascular density of the involved area was expressed as number of vascular structures per square millimeter (+/-1 standard deviation). RESULTS: The vascular density of the scar tissue of the laser channel was significantly increased in comparison with myocardial infarction alone: 49.6+/-12.8/mm2 versus 25.5+/-8.6/mm2 (p < 0.0001). The vascular densities of subendocardial and subepicardial channel areas were similar: 52.9+/-16.8/mm2 versus 46.3+/-13.6/mm2 (p = 0.41). The area immediately adjacent to the channels showed a vascular density similar to that of normal tissue: 6.02+/-1.7/mm2 versus 5.2+/-1.9/mm2 (p = 0.08). In the infarction + transmyocardial laser revascularization group, the channels were indistinguishable from infarction scar. CONCLUSIONS: Scars of transmyocardial laser revascularization channels exhibit an increased vascular density in comparison with scar tissue of myocardial infarction, which does not extend into their immediate vicinity. There was no vascular density gradient along the longitudinal axis of the channels.
Resumo:
The jointly voluntary and involuntary control of respiration, unique among essential physiological processes, the interconnection of breathing with and its influence on the autonomic nervous system, and disease states associated with the interface between psychology and respiration (e.g., anxiety disorders, hyperventilation syndrome, asthma) make the study of the relationship between respiration and emotion both theoretically and clinically of great relevance. However, the respiratory behavior during affective states is not yet completely understood. We studied breathing pattern responses to 13 picture series varying widely in their affective tone in 37 adults (18 men, 19 women, mean age 26). Time and volume parameters were recorded with the LifeShirt system (VivoMetrics Inc., Ventura, California, USA, see image). We also measured end-tidal pCO2 (EtCO2) with a Microcap Handheld Capnograph (Oridion Medical 1987 Ltd., Jerusalem, Israel) to determine if ventilation is in balance with metabolic demands and spontaneous eye-blinking to investigate the link between respiration and attention. At the end of each picture series, the participants reported their subjective feeling in the affective dimensions of pleasantness and arousal. Increasing self-rated arousal was associated with increasing minute ventilation but not with decreases in EtCO2, suggesting that ventilatory changes during picture viewing paralleled variations in metabolic activity. EtCO2 correlated with pleasantness, and eye-blink rate decreased with increasing unpleasantness in line with a negativity bias in attention. Like MV, inspiratory drive (i.e., mean inspiratory flow) increased with arousal. This relationship reflected increases in inspiratory volume rather than shortening of the time parameters. This study confirms that respiratory responses to affective stimuli are organized to a certain degree along the dimensions of pleasantness and arousal. It shows, for the first time, that during picture viewing, ventilatory increases with increasing arousal are in balance with metabolic activity and that inspiratory volume is modulated by arousal. MV emerges as the most reliable respiratory index of self-perceived arousal. Finally, end-tidal pCO2 is slightly lower during processing of negative as compared to positive picture contents, which is proposed to enhance sensory perception and reflect a negativity bias in attention.
Resumo:
Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.