891 resultados para 720501 Defence standards and calibrations
Resumo:
A comprehensive analysis of electrodisintegration yields of protons on Zr90 is proposed taking into account the giant dipole resonance, isovector giant quadrupole resonance (IVGQR), and quasideuteron contributions to the total photoabsorption cross section from 10 to 140 MeV. The calculation applies the MCMC intranuclear cascade to address the direct and pre-equilibrium emissions and another Monte Carlo-based algorithm to describe the evaporation step. The final results of the total photoabsorption cross section for Zr90 and relevant decay channels are obtained by fitting the (e,p) measurements from the National Bureau of Standards and show that multiple proton emissions dominate the photonuclear reactions at higher energies. These results provide a consistent explanation for the exotic and steady increase of the (e,p) yield and also a strong evidence of a IVGQR with a strength parameter compatible with the E2 energy-weighted sum rule. The inclusive photoneutron cross sections for Zr90 and natZr, derived from these results and normalized with the (e,p) data, are in agreement within 10% with both Livermore and Saclay data up to 140 MeV. © 2007 The American Physical Society.
Resumo:
The contents of some nutrients in 35 Brazilian green and roasted coffee samples were determined by flame atomic absorption spectrometry (Ca, Mg, Fe, Cu, Mn, and Zn), flame atomic emission photometry (Na and K) and Kjeldahl (N) after preparing the samples by wet digestion procedures using i) a digester heating block and ii) a conventional microwave oven system with pressure and temperature control. The accuracy of the procedures was checked using three standard reference materials (National Institute of Standards and Technology, SRM 1573a Tomato Leaves, SRM 1547 Peach Leaves, SRM 1570a Trace Elements in Spinach). Analysis of data after application of t-test showed that results obtained by microwave-assisted digestion were more accurate than those obtained by block digester at 95% confidence level. Additionally to better accuracy, other favorable characteristics found were lower analytical blanks, lower reagent consumption, and shorter digestion time. Exploratory analysis of results using Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) showed that Na, K, Ca, Cu, Mg, and Fe were the principal elements to discriminate between green and roasted coffee samples. ©2007 Sociedade Brasileira de Química.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes Bibliography
Resumo:
This article aims to present proposals for improvement of key standards and resolutions concerned about the methodology for calculating the indicator of total harmonic voltage distortion, and should contribute to the process of examining the compatibility of potentially disturbing loads in electric power quality in distribution systems. These proposals were drawn from the analysis of results from measurement campaigns conducted in a case study including analysis of the connection of a new induction furnace in a foundry served by a distributor of São Paulo state. A general historical situating the quality of electric energy in the electricity sector is presented, and methodological guidelines and procedures used in experimental trials are shown. The analysis and discussion of results are prepared to answer the main questions that arise during the implementation of standards, resolutions and procedures. © 2011 IEEE.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
At this time, each major automotive market bares its own standards and test procedures to regulate the vehicle green house gases emissions and, thus, fuel consumption. Hence, much are the ways to evaluate the overall efficiency of motor vehicles. The majority of such standards rely on dynamometer cycle tests that appraise only the vehicle as a whole, but fail to assess emissions for each component or sub-system. Once the amount of work generated by the power source of an ICE vehicle to overcome the driving resistance forces is proportional to the energy contained in the required amount of fuel, the power path of the vehicle can be straightforwardly modeled as a set of mechanical systems, and each sub-system evaluated for its share on the total fuel consumption and green house gases emission. This procedure enables the estimation of efficiency gains on the system due to improvement of particular elements on the vehicle's driveline. In this work a simple systematic mechanical model of an arbitrary smallsized hatch back was assembled and total required energy calculated for different regulatory cycles. All the modeling details of the energy balance throughout the system are presented. Afterward, each subsystem was investigated for its role on the fuel consumption and the generated emission quantified. Furthermore, the application of the modeling technique for different sets of sub-systems was introduced. Copyright © 2011 SAE International.
Resumo:
This paper proposes a simple and powerful architecture for publication and universal access to smart transducers, through existing and established open standards. Smart transducers are put to work on standards and styles already included in the Web, exploring resources in Cloud Computing and simplifying access to data. © 2012 IEEE.
Resumo:
The Economic Commission for Latin America and the Caribbean (ECLAC) Subregional Headquarters for the Caribbean, in collaboration with the World Bank, conducted a week-long Regional Workshop on Microdata Documentation and Dissemination. The workshop, which was funded by the Partnership in Statistics for Development in the Twenty-First Century (PARIS21) and the Organization for Economic Co-operation and Development (OECD), was held at the Hilton Hotel and Conference Centre in Port of Spain, Trinidad, from 26 to 30 April 2010. The main objective of the workshop was to provide training to member States on the Microdata Management Toolkit. This toolkit was developed by International Household Surveys Networks (IHSN) to assist in the documentation, dissemination and preservation of household survey, census and microdata in accordance with international standards and best practices. The training was organized in response to numerous requests by directors of statistics in the region for the development of capacity in that area. It was specifically timed to meet the training needs of those offices ahead of the 2010 round of Population and Housing Censuses.
Resumo:
A presente dissertação trata sobre o Sistema de Gestão implantado no Centro de Tecnologia da Eletrobras - Eletronorte – OCT, face à norma ABNT NBR ISO/IEC17025. Objetiva analisar o Sistema de Gestão da Qualidade em laboratório de ensaio. Expõe o crescimento do uso de sistemas de gestão, para dizer que em geral tem aumentado à necessidade de assegurar que laboratórios que fazem parte de organizações maiores ou que oferecem outros serviços possam operar de acordo com um sistema de gestão que esteja em conformidade com a norma ABNT NBR ISO 9001. Para conduzir e operar com sucesso uma organização é necessário dirigila e controlá-la de maneira transparente e sistemática. Verifica-se que seu sucesso pode resultar da implementação e manutenção de um sistema de gestão concebido para melhorar continuamente seu desempenho, levando em consideração, ao mesmo tempo, as necessidades de todas as partes interessadas. Os laboratórios acreditados garantem aspectos referentes à confiabilidade, a confidencialidade dos resultados propostos, além da rastreabilidade dos padrões utilizados nos ensaios e calibrações.
Resumo:
The aim of this study is to perform a situational analysis of the Laboratory of pulp and paper-UNESP ITAPEVA for conducting proposal the accreditation according to ISO / IEC 17025:2005. The ISO / IEC 17025 establishes the criteria for those laboratories wishing to demonstrate their technical competence, which have an effective quality system and are able to generate technically valid results, establishing a single international standard for certifying the competence of laboratories to carry tests and / or calibrations, including sampling. The case study was conducted on laboratory Pulp and Paper Universidade Estadual Paulista (UNESP), campus Itapeva, where we compared the views of the technician responsible for the laboratory and a regular user. The generated conclusion is that the laboratory is unable to initiate an accreditation process, because it fails the requirements such as quality manual, register of subcontractors, research of customer satisfaction, schedule of internal audits, schedule for completion of critical analysis, profile of the functions required, functions current description, documentation of technical requirements for accommodation and environmental conditions, calibration programs, equipment calibration program, programs calibration standards and reports and / or certificate of test and / or calibration, that are in accordance with ISO / IEC 17025:2005, beyond that there is not the possibility to develop and implement a quality system without the commitment of everyone involved, regardless of the functional hierarchy
Resumo:
This work aimed to assess the bacteriological quality of water used in the irrigation of vegetable gardens in the municipalities of Araraquara, Boa Esperança do Sul and Ibitinga, São Paulo, Brazil. A total of 80 samples of water used in the irrigation of 40 vegetable gardens were analyzed, two samples coming from each vegetable garden. They were collected at the same site in different months, which resulted in two sample collection groups. The most probable number (MPN/100mL) of total coliforms, thermotolerant coliforms and enterococci was identifi ed by means of the multiple tube technique. The analysis of the fi rst group samples showed quantities of thermotolerant coliforms above the amount allowed by current law for irrigation water (CONAMA Resolution n. 357) in nine cases. The owners of those vegetable gardens were then instructed in water disinfection procedures. After the analysis of the second group samples, it was noticed that only one sample did not meet the quality standards, and it was collected at a site where no disinfection procedure had been carried out. According to the results, 77.5% of the vegetable gardens were using water whose samples meet the quality standards. After the owners were instructed with regard to disinfection procedures, that number changed to 97.5%, which confi rms the importance of controlling and supervising irrigation water quality
Resumo:
Today, many leading organizations are undertaking extensive research on a very broad range of new and evolving optical networking technologies. These efforts carry particular significance, especially in light of the “postbubble” dynamics of the optical networking market and have led to the investigation of various cost-efficient optical technologies. Today’s telecom carriers operate several independent optical domains based on diverse technologies, control solutions, standards, and protocols, making interdomain and intercarrier interworking extremely difficult. Standardized interworking across diverse multigranularity network interfaces, and interoperability across disparate vendor equipments and carrier domains are crucial to provisioning end-to-end services and achieving cost-efficient network operation. Needless to say, having an interoperable and standard control plane across multidomain optical networks can benefit carriers through the availability of a wide selection of network elements, platforms, and multiple vendor solutions resulting in faster deployment and reduced CAPEX and OPEX charges.