982 resultados para 3-22


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Iodine chemistry plays an important role in the tropospheric ozone depletion and the new particle formation in the Marine Boundary Layer (MBL). The sources, reaction pathways, and the sinks of iodine are investigated using lab experiments and field observations. The aims of this work are, firstly, to develop analytical methods for iodine measurements of marine aerosol samples especially for iodine speciation in the soluble iodine; secondly, to apply the analytical methods in field collected aerosol samples, and to estimate the characteristics of aerosol iodine in the MBL. Inductively Coupled Plasma – Mass Spectrometry (ICP-MS) was the technique used for iodine measurements. Offline methods using water extraction and Tetra-methyl-ammonium-hydroxide (TMAH) extraction were applied to measure total soluble iodine (TSI) and total insoluble iodine (TII) in the marine aerosol samples. External standard calibration and isotope dilution analysis (IDA) were both conducted for iodine quantification and the limits of detection (LODs) were both 0.1 μg L-1 for TSI and TII measurements. Online couplings of Ion Chromatography (IC)-ICP-MS and Gel electrophoresis (GE)-ICP-MS were both developed for soluble iodine speciation. Anion exchange columns were adopted for IC-ICP-MS systems. Iodide, iodate, and unknown signal(s) were observed in these methods. Iodide and iodate were separated successfully and the LODs were 0.1 and 0.5 μg L-1, respectively. Unknown signals were soluble organic iodine species (SOI) and quantified by the calibration curve of iodide, but not clearly identified and quantified yet. These analytical methods were all applied to the iodine measurements of marine aerosol samples from the worldwide filed campaigns. The TSI and TII concentrations (medians) in PM2.5 were found to be 240.87 pmol m-3 and 105.37 pmol m-3 at Mace Head, west coast of Ireland, as well as 119.10 pmol m-3 and 97.88 pmol m-3 in the cruise campaign over the North Atlantic Ocean, during June – July 2006. Inorganic iodine, namely iodide and iodate, was the minor iodine fraction in both campaigns, accounting for 7.3% (median) and 5.8% (median) in PM2.5 iodine at Mace Head and over the North Atlantic Ocean, respectively. Iodide concentrations were higher than iodate in most of the samples. In the contrast, more than 90% of TSI was SOI and the SOI concentration was correlated significantly with the iodide concentration. The correlation coefficients (R2) were both higher than 0.5 at Mace Head and in the first leg of the cruise. Size fractionated aerosol samples collected by 5 stage Berner impactor cascade sampler showed similar proportions of inorganic and organic iodine. Significant correlations were obtained in the particle size ranges of 0.25 – 0.71 μm and 0.71 – 2.0 μm between SOI and iodide, and better correlations were found in sunny days. TSI and iodide existed mainly in fine particle size range (< 2.0 μm) and iodate resided in coarse range (2.0 – 10 μm). Aerosol iodine was suggested to be related to the primary iodine release in the tidal zone. Natural meteorological conditions such as solar radiation, raining etc were observed to have influence on the aerosol iodine. During the ship campaign over the North Atlantic Ocean (January – February 2007), the TSI concentrations (medians) ranged 35.14 – 60.63 pmol m-3 among the 5 stages. Likewise, SOI was found to be the most abundant iodine fraction in TSI with a median of 98.6%. Significant correlation also presented between SOI and iodide in the size range of 2.0 – 5.9 μm. Higher iodate concentration was again found in the higher particle size range, similar to that at Mace Head. Airmass transport from the biogenic bloom region and the Antarctic ice front sector was observed to play an important role in aerosol iodine enhancement. The TSI concentrations observed along the 30,000 km long cruise round trip from East Asia to Antarctica during November 2005 – March 2006 were much lower than in the other campaigns, with a median of 6.51 pmol m-3. Approximately 70% of the TSI was SOI on average. The abundances of inorganic iodine including iodine and iodide were less than 30% of TSI. The median value of iodide was 1.49 pmol m-3, which was more than four fold higher than that of iodate (median, 0.28 pmol m-3). Spatial variation indicated highest aerosol iodine appearing in the tropical area. Iodine level was considerably lower in coastal Antarctica with the TSI median of 3.22 pmol m-3. However, airmass transport from the ice front sector was correlated with the enhance TSI level, suggesting the unrevealed source of iodine in the polar region. In addition, significant correlation between SOI and iodide was also shown in this campaign. A global distribution in aerosol was shown in the field campaigns in this work. SOI was verified globally ubiquitous due to the presence in the different sampling locations and its high proportion in TSI in the marine aerosols. The correlations between SOI and iodide were obtained not only in different locations but also in different seasons, implying the possible mechanism of iodide production through SOI decomposition. Nevertheless, future studies are needed for improving the current understanding of iodine chemistry in the MBL (e.g. SOI identification and quantification as well as the update modeling involving organic matters).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Compliance lebertransplantierter Patienten mit der immunsuppressiven Therapie ist unerlässlich für den lang-fristigen Erfolg der Lebertransplantation. Aus Non-Compliance mit der immunsuppressiven Therapie können Abstoßungsreaktionen, Organverlust oder sogar Tod resultieren. Hauptziel der vorliegenden Studie war die erstmalige Evaluation der Compliance bei Einnahme von Prograf® (zweimal tägliche Einnahme von Tacrolimus) im Vergleich zur Einnahme von Advagraf® (einmal tägliche Einnahme von Tacrolimus). Von Interesse war außerdem die Fragestellung, ob sich die Compliance bezüglich der immunsuppressiven Therapie mit dem Zeitabstand zur Transplantation verändert. rnDie Compliancemessung wurde offen mittels MEMS® (Aardex Ltd., Schweiz) durchgeführt, der Patient war also über die Compliancekontrolle informiert. Mittels MEMS® konnten Datum und Uhrzeit der Dosisentnahme dokumentiert und damit zuverlässig das gesamte Compliancemuster über im Durchschnitt 176 Tage mit der zweimal täglichen Einnahme und 188 Tage mit der einmal täglichen Einnahme pro Patient erfasst werden. 65 Patienten mit dem Basisimmunsuppressivum Prograf® wurden in die prospektive, nicht-interventionelle Studie eingeschlossen und nach Per Protokoll-Analyse konnten die Daten von 63 in Mainz lebertransplantierten Patienten ausgewertet werden (Prograf®: Gruppe 1: 15 Patienten (Pat.), Gruppe 2: 23 Pat., Gruppe 3: 22 Pat., Drop-outs: 3 Pat.; Advagraf®: Gruppe 1: 16 Pat., Gruppe 2: 23 Pat., Gruppe 3: 23 Pat., Drop-outs: 1 Pat.). Die Dosing Compliance (DC), definiert als Prozent der Tage, an denen der MEMS®-Behälter korrekt geöffnet und die Dosis höchstwahrscheinlich korrekt eingenommen wurde, war der primäre Zielparameter. Weitere Methoden der Compliancemessung, wie der Pill Count, mehrere Fragebögen (Selbsteinschätzung, Patientenwissen-, Morisky-, MESI-, HADS-, SF-36- und Patientenzufriedenheit-Fragebogen) sowie die Blutspiegelmessung wurden eingesetzt, um die Compliance der Patienten umfassend charakterisieren zu können. rnDer Median der DC mit der zweimal täglichen Einnahme betrug 97% bei Pat. > 6 m.p.t. < 2 y.p.t., 97% bei Pat. > 2 y.p.t. < 5 y.p.t. und 98% bei Pat. > 5 y.p.t. (p=0,931; Kruskal-Wallis-Test). Der Median der DC von Tacroli-mus bei einmal täglicher Einnahme (Advagraf®) betrug 99% bei Pat. > 6 m.p.t. < 2 y.p.t., 98% bei Pat. > 2 y.p.t. < 5 y.p.t. und 97% bei Pat. > 5 y.p.t. (p=0,158; Kruskal-Wallis-Test). Insgesamt zeigten die Patienten während des gesamten Beobachtungszeitraums von 12 Monaten eine gute Compliance für die Einnahme ihres Immun-suppressivums. Die Timing Compliance (TiC)-raten lagen auf einem niedrigeren Niveau als die Dosing- und Taking Compliance (TC)-raten. Die Complianceraten der drei Subgruppen unterschieden sich nicht signifikant. Die Patienten mit dem geringsten Abstand zur Transplantation zeigten bei beinahe allen Messmethoden die höchste Compliance im Gegensatz zur etwas geringeren Compliance der Patienten mit größerem Abstand zur Transplantation. Die während der Advagraf®-Phase mittels MEMS® gemessenen DC-, TC- und TiC-raten fielen höher aus als bei Einnahme von Prograf® (p(DC)=0,003; p(TC)=0,077; p(TiC)=0,003; Wilcoxon Vorzeichen-Rang-Test). Dieses Ergebnis untermauert die in anderen Indikationen gefundene Complianceverbesserung durch die einmal tägliche Arzneimittelgabe im Vergleich zur zweimal täglichen Gabe. Die Auswertung der Drug Holidays ergab für die Advagraf®-Phase hingegen niedrigere Complianceraten als für die Prograf®-Phase. Dieses Ergebnis ist auf die Definition des Drug Holidays (keine Arzneimitteleinnahme über 48 h) zurück zu führen. Die Chance Advagraf® einmal pro Tag zu vergessen ist doppelt so hoch, als Prograf® dreimal aufeinander fol-gend zu vergessen. Mit einer verhältnismäßigeren Definition von Drug Holidays (Einnahmepause von 72 Stun-den bei einmal täglicher Einnahme von Advagraf® entsprechend drei ausgelassenen Dosen von Prograf®) ist die Compliancerate 81%. Die Ergebnisse des Pill Counts waren sowohl bei Einnahme von Prograf® als auch von Advagraf® mit der jeweils gemessenen TC vergleichbar, was die Zuverlässigkeit der Messergebnisse bes-tätigt. rnDie zusätzlich eingesetzten Methoden verifizierten das Ergebnis der höheren Compliance mit der einmal tägli-chen Einnahme. Die während der Advagraf®-Phase beantworteten Fragebögen zeigten einen Trend zu besserer Compliance und Lebensqualität. Lediglich die Ergebnisse des MESI-Fragebogens und der Blutspiegelmessungen wichen sowohl während der Prograf®- als auch während der Advagraf®-Phase stark von den Ergebnis-sen der anderen Methoden ab. rnUnter Einbeziehung aller mittels MEMS® und Pill Count objektiv gemessenen Complianceparameter konnten während der Prograf®-Einnahme 54 von 60 Pat. (90%) und während der Advagraf®-Phase 59 von 62 Pat. (95%) als compliant eingestuft werden. Aufgrund subjektiver Compliancemessungen waren 49 von 58 Pat. (84%) während der Prograf®- und 54 von 59 Pat. (92%) während der Advagraf®-Phase als compliant einzustufen. Es wurde beobachtet, dass die zeitlich korrekte Einnahme der Morgendosis einfacher und bei Einmalgabe zu bevorzugen ist. Die wochentagsbezogene Auswertung ergab erwartungsgemäß, dass am Wochenende (Samstag und Sonntag) am häufigsten Dosen ausgelassen wurden. rnDie Umstellung von Prograf® auf Advagraf® stellte kein Problem dar. Beinahe alle Patienten waren dankbar und zufrieden mit der Reduzierung der Dosierungsfrequenz und der größeren Unabhängigkeit durch die entfallene abendliche Einnahme. Der positive Einfluss der geringeren Dosierungshäufigkeit auf die Langzeitcompliance der Patienten, ist ein hinreichender Grund die Entwicklung von Formulierungen zur einmal täglichen Ein-nahme für weitere Immunsuppressiva zu fordern. Insbesondere bei den häufig eingesetzten Kombinationstherapien von Immunsuppressiva würde der Effekt der Complianceverbesserung noch verstärkt werden, wenn alle eingesetzten Immunsuppressiva zur einmal täglichen Gabe geeignet wären.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Questo studio prospettico valuta l’efficacia e i vantaggi del sistema LigasureTM rispetto alle tecniche chirurgiche tradizionali, in quattro differenti procedure eseguite su 77 cani. I soggetti sono stati suddivisi in 4 gruppi, a seconda della chirurgia eseguita: Gruppo 1, 25 pazienti sottoposti a Splenectomia “aperta” semplice; Gruppo 2, 15 pazienti sottoposti a Splenectomia “aperta” complessa; Gruppo 3, 22 pazienti sottoposti ad Ovariectomia “aperta”. Gruppo 4: 18 pazienti sottoposti a Linfoadenectomia. Ciascun gruppo è stato a sua volta suddiviso in due sottogruppi: a (LigasureTM) e b (Tradizionale), a seconda della metodica utilizzata. Sono stati analizzati: il segnalamento, i parametri ematologici, le condizioni cliniche, le informazioni riguardanti l’intervento chirurgico e l’outcome. In tutti i gruppi il ricorso all’utilizzo di garze nonché dei fili da sutura sono risultati statisticamente inferiori nei pazienti operati con il sistema a radiofrequenza (Gruppo 1, P < 0.0001; Gruppo 2, P < 0,0014; Gruppo 3, P = 0,0001; Gruppo 4, P = 0,0148). Anche i tempi per la rimozione dell’organo sono significativamente ridotti in tutti i gruppi in cui è stato utilizzato il sistema LigasureTM (Gruppo 1 P < 0.0001; Gruppo 2 P < 0,0014; Gruppo 3 P = 0,0009; Gruppo 4 P = 0,0008), come i tempi chirurgici nei gruppi 1, 2 e 3 (P = 0,0287; P = 0,0064; e P = 0,0124) ed anestesiologici nei gruppi 1a e 2a (P = 0,0176; P = 0,0043). Tra le variabili analizzate, l’utilizzo del sistema di sintesi vascolare a radiofrequenza, è l’unico ad influenzare i tempi necessari per l’esecuzione della procedura. Questo studio dimostra, quindi, come il sistema LigasureTM sia sicuro ed efficace per le procedure chirurgiche esaminate, riducendo i tempi della chirurgia e limitando, quindi, i rischi per il paziente, indipendentemente dall’operatore, dall’esecuzione di altre procedure contemporanee e dalla natura della patologia splenica o linfonodale.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recurrent airway obstruction (RAO) is a common condition in stabled horses characterized by small airway inflammation, airway neutrophilia and obstruction following exposure of susceptible horses to mouldy hay and straw and is thus regarded as a hypersensitivity reaction to mould spores. However, the role of immunoglobulin E antibodies (IgE) in the pathogenesis of RAO is unclear. We hypothesized that the number of cells with receptor-bound IgE in bronchoalveolar lavage fluid (BALF) and IgE levels in serum would be higher in RAO-affected than in healthy horses living in the same environment. Therefore, IgE-positive (+) cells were identified by immunocytochemistry on cytospins from BALF and counted. IgE levels against the mould extracts Aspergillus fumigatus (Asp. f.) and Alternaria alternata (Alt. a.) and the recombinant mould allergen Aspergillus fumigatus 8 (rAsp f 8) were measured by enzyme-linked immunosorbent assay (ELISA) in the sera of seven RAO-affected and 22 clinically healthy mature horses housed in the same conventional stable environment. After correcting for the number of neutrophils, there were no significant differences in IgE+ cells on cytospins from BALF between both groups of horses (5% versus 7%, P > 0.1). Serum IgE levels against the mould extracts were significantly higher in RAO-affected than in clinically healthy horses [median = 119 versus 66 relative ELISA units (REU), P < 0.05]. Furthermore, significantly more RAO-affected than healthy horses had detectable serum IgE against the recombinant allergen rAsp f 8 (4/7 and 3/22, respectively, P < 0.05). Age had no significant effect on BALF cell ratios or on specific serum IgE levels. These results show that high IgE levels against mould antigens are associated with RAO under controlled environmental conditions but ranges of mould-specific serum IgE levels overlapped too much between diseased and clinically healthy animals to be of any diagnostic value. Further studies are needed to assess whether IgE-mediated reactions contribute to the pathogenesis of RAO.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To investigate predictors of continued HIV RNA viral load suppression in individuals switched to abacavir (ABC), lamivudine (3TC) and zidovudine (ZDV) after successful previous treatment with a protease inhibitor or non-nucleoside reverse transcriptase inhibitor-based combination antiretroviral therapy. DESIGN AND METHODS: An observational cohort study, which included individuals in the Swiss HIV Cohort Study switching to ABC/3TC/ZDV following successful suppression of viral load. The primary endpoint was time to treatment failure defined as the first of the following events: two consecutiveviral load measurements > 400 copies/ml under ABC/3TC/ZDV, one viral load measurement > 400 copies/ml and subsequent discontinuation of ABC/3TC/ZDV within 3 months, AIDS or death. RESULTS: We included 495 individuals; 47 experienced treatment failure in 1459 person-years of follow-up [rate = 3.22 events/100 person-years; 95% confidence interval (95% CI), 2.30-4.14]. Of all failures, 62% occurred in the first year after switching to ABC/3TC/ZDV. In a Cox regression analysis, treatment failure was independently associated with earlier exposure to nucleoside reverse transcriptase inhibitor (NRTI) mono or dual therapy [hazard ratio (HR), 8.02; 95% CI, 4.19-15.35) and low CD4 cell count at the time of the switch (HR, 0.66; 95% CI, 0.51-0.87 by +100 cells/microl up to 500 cells/microl). In patients without earlier exposure to mono or dual therapy, AIDS prior to switch to simplified maintenance therapy was an additional risk factor. CONCLUSIONS: The failure rate was low in patients with suppressed viral load and switch to ABC/3TC/ZDV treatment. Patients with earlier exposure to mono or dual NRTI therapy, low CD4 cell count at time of switch, or AIDS are at increased risk of treatment failure, limiting the use of ABC/3TC/ZDV in these patient groups.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: To use amifostine concurrently with radiochemotherapy (CT-RT) or radiotherapy (RT) alone in order to prevent dry eye syndrome in patients with malignancies located in the fronto-orbital region. METHODS: Five patients (2 males, 3 females) with diagnosed malignancies (Non-Hodgkin B-cell Lymphoma, neuroendocrine carcinoma) involving the lacrimal gland, in which either combined CT-RT or local RT were indicated, were prophylactically treated with amifostine (500 mg sc). Single RT fraction dose, total dose and treatment duration were individually adjusted to the patient's need. Acute and late adverse effects were recorded using the RTOG score. Subjective and objective dry eye assessment was performed for the post-treatment control of lacrimal gland function. RESULTS: All patients have completed CT-RT or RT as indicated. The median total duration of RT was 29 days (range, 23 - 39 days) and the median total RT dose was 40 Gy (range, 36 - 60 Gy). Median lacrimal gland exposure was 35.9 Gy (range, 16.8 - 42.6 Gy). Very good partial or complete tumor remission was achieved in all patients. The treatment was well tolerated without major toxic reactions. Post-treatment control did not reveal in any patient either subjective or objective signs of a dry eye syndrome. CONCLUSION: The addition of amifostine to RT/CT-RT of patients with tumors localized in orbital region was found to be associated with absence of dry eye syndrome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tin is a notable anti-erosive agent, and the biopolymer chitosan has also shown demineralisation-inhibiting properties. Therefore, the anti-erosive/anti-abrasive efficacy of the combination of both compounds was tested under in situ conditions. Twenty-seven volunteers were included in a randomised, double-blind, three-cell crossover in situ trial. Enamel specimens were recessed on the buccal aspects of mandibular appliances, extraorally demineralised (6 × 2 min/day) and intraorally treated with toothpaste slurries (2 × 2 min/day). Within the slurry treatment time, one-half of the specimens received additional intraoral brushing (5 s, 2.5 N). The tested toothpastes included a placebo toothpaste, an experimental NaF toothpaste (1,400 ppm F(-)) and an experimental F/Sn/chitosan toothpaste (1,400 ppm F(-), 3,500 ppm Sn(2+), 0.5% chitosan). The percentage reduction of tissue loss (slurry exposure/slurry exposure + brushing) compared to placebo was 19.0 ± 47.3/21.3 ± 22.4 after use of NaF and 52.5 ± 30.9/50.2 ± 34.3 after use of F/Sn/chitosan. F/Sn/chitosan was significantly more effective than NaF (p ≤ 0.001) and showed good efficacy against erosive and erosive-abrasive tissue loss. This study suggests that the F/Sn/chitosan toothpaste could provide good protection for patients who frequently consume acidic foodstuffs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Human immunodeficiency virus type 1 (HIV-1) transmitted drug resistance (TDR) can compromise antiretroviral therapy (ART) and thus represents an important public health concern. Typically, sources of TDR remain unknown, but they can be characterized with molecular epidemiologic approaches. We used the highly representative Swiss HIV Cohort Study (SHCS) and linked drug resistance database (SHCS-DRDB) to analyze sources of TDR. METHODS ART-naive men who have sex with men with infection date estimates between 1996 and 2009 were chosen for surveillance of TDR in HIV-1 subtype B (N = 1674), as the SHCS-DRDB contains pre-ART genotypic resistance tests for >69% of this surveillance population. A phylogeny was inferred using pol sequences from surveillance patients and all subtype B sequences from the SHCS-DRDB (6934 additional patients). Potential sources of TDR were identified based on phylogenetic clustering, shared resistance mutations, genetic distance, and estimated infection dates. RESULTS One hundred forty of 1674 (8.4%) surveillance patients carried virus with TDR; 86 of 140 (61.4%) were assigned to clusters. Potential sources of TDR were found for 50 of 86 (58.1%) of these patients. ART-naive patients constitute 56 of 66 (84.8%) potential sources and were significantly overrepresented among sources (odds ratio, 6.43 [95% confidence interval, 3.22-12.82]; P < .001). Particularly large transmission clusters were observed for the L90M mutation, and the spread of L90M continued even after the near cessation of antiretroviral use selecting for that mutation. Three clusters showed evidence of reversion of K103N or T215Y/F. CONCLUSIONS Many individuals harboring viral TDR belonged to transmission clusters with other Swiss patients, indicating substantial domestic transmission of TDR in Switzerland. Most TDR in clusters could be linked to sources, indicating good surveillance of TDR in the SHCS-DRDB. Most TDR sources were ART naive. This, and the presence of long TDR transmission chains, suggests that resistance mutations are frequently transmitted among untreated individuals, highlighting the importance of early diagnosis and treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PRINCIPALS Accidents in agriculture are a problem of global importance. The hazards of working in agriculture are manifold (machines, animals, heights). We therefore assessed injury severity and mortality from accidents in farming. METHODS We retrospectively analysed all farming accidents treated over a 12-year period in the emergency department (ED) of our level I trauma centre. RESULTS Out of 815 patients 96.3% were male and 3.7% female (p <0.0001). A total of 70 patients (8.6%, 70/815) were severely injured. Patients with injuries to the chest were most likely to suffer from severe injuries (odds ratio [OR] 9.45, 95% confidence interval [CI] 5.59-16.00, p <0.0001), followed by patients with injuries to the abdomen (OR 7.06, 95% CI 3.22-15.43, p <0.0001) and patients with injuries to the head (OR 5.03, 95% CI 2.99-8.66, p <0.0001). Hospitalisation was associated with machine- and fall-related injuries (OR 22.39, 95% CI 1.95-4.14, p <0.0001 and OR 2.84 95% CI 1.68-3.41 p <0.001, respectively). Patients suffering from a fall and patients with severe injury were more likely to die than others (OR 3.32, 95% CI 1.07-10.29, p <0.037 and OR 9.17, 95% CI 6.20-13.56, p <0.0001, respectively). Fall height correlated positively with the injury severity score , hospitalisation and mortality (all p <0.0001). CONCLUSION Injuries in agriculture are accompanied by substantial morbidity and mortality, and range from minor injuries to severe multiple injuries. Additional prospective studies should be conducted on injury severity, long-term disability and mortality.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Most healthcare in the US is delivered in the ambulatory care setting, but the epidemiology of errors and adverse events in ambulatory care is understudied. METHODS: Using the population-based data from the Colorado and Utah Medical Practices Study, we identified adverse events that occurred in an ambulatory care setting and led to hospital admission. Proportions with 95% CIs are reported. RESULTS: We reviewed 14,700-hospital discharge records and found 587 adverse events of which 70 were ambulatory care adverse events (AAEs) and 31 were ambulatory care preventable adverse events (APAEs). When weighted to the general population, there were 2608 AAEs and 1296 (44.3%) APAEs in Colorado and Utah, USA, in 1992. APAEs occurred most commonly in physicians' offices (43.1%, range 46.8-27.8), the emergency department (32.3%, 46.1-18.5) and at home (13.1%, 23.1-3.1). APAEs in day surgery were less common (7.1%, 13.6-0.6) but caused the greatest harm to patients. The types of APAEs were broadly distributed among missed or delayed diagnoses (36%, 50.2-21.8), surgery (24.1%, 36.7-11.5), non-surgical procedures (14.6%, 25.0-4.2), medication (13.1%, 23.1-3.1) and therapeutic events (12.3%, 22.0-2.6). Overall, 10% of the APAEs resulted in serious permanent injury or death. The proportion of APAEs that resulted in death was 31.8% for general internal medicine, 22.5% for family practice and 16.7% for emergency medicine. CONCLUSION: An estimated 75,000 hospitalisations per year are due to preventable adverse events that occur in outpatient settings in the US, resulting in 4839 serious permanent injuries and 2587 deaths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose We hypothesized that reduced arousability (Richmond Agitation Sedation Scale, RASS, scores −2 to −3) for any reason during delirium assessment increases the apparent prevalence of delirium in intensive care patients. To test this hypothesis, we assessed delirium using the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and Intensive Care Delirium Screening Checklist (ICDSC) in intensive care patients during sedation stops, and related the findings to the level of sedation, as assessed with RASS score. Methods We assessed delirium in 80 patients with ICU stay longer than 48 h using CAM-ICU and ICDSC during daily sedation stops. Sedation was assessed using RASS. The effect of including patients with a RASS of −2 and −3 during sedation stop (“light to moderate sedation”, eye contact less than 10 s or not at all, respectively) on prevalence of delirium was analyzed. Results A total of 467 patient days were assessed. The proportion of CAM-ICU-positive evaluations decreased from 53 to 31 % (p < 0.001) if assessments from patients at RASS −2/−3 (22 % of all assessments) were excluded. Similarly, the number of positive ICDSC results decreased from 51 to 29 % (p < 0.001). Conclusions Sedation per se can result in positive items of both CAM-ICU and ICDSC, and therefore in a diagnosis of delirium. Consequently, apparent prevalence of delirium is dependent on how a depressed level of consciousness after sedation stop is interpreted (delirium vs persisting sedation). We suggest that any reports on delirium using these assessment tools should be stratified for a sedation score during the assessment.