886 resultados para Éguas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this manuscript, seasonal and spatial trends of water collected from two sampling places in the Preto River in the Turvo-Grande watershed were evaluated. Water samples were collected during June/07 to July/08 and parameters sulphate, total organic carbon, ammonia, conductivity, dissolved oxygen, temperature, dissolved total solids and nitrate were quantified. Seasonal trend indicated sanitary effluents as a point source of contamination in both sampling points. Vertical trends demonstrated that the Municipal Dam was not stratified and received a diffuse source of pollutants from flooding and agriculture runoffs. It was also verified that there is relatively fast ammonia consumption kinetics having a half-life time of 1.43 h which can explain the low ammonia concentrations found in these aquatic bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com os crescentes conflitos de uso da água no Brasil, a implantação de políticas para a mitigação desses problemas tornou-se crucial. Nesse sentido, o conceito de Pagamentos por Serviços Ambientais (PSA) tem se difundido ao redor do mundo e, consequentemente, no Brasil. O município de Extrema, em Minas Gerais, implantou a primeira iniciativa municipal brasileira de PSA, conhecida como programa Conservador das Águas. Neste trabalho, objetivou-se avaliar a perda de solo na sub-bacia das Posses, onde se iniciou o programa Conservador das Águas, visando determinar a potencialidade que o conceito adotado nesse programa terá para a conservação do solo e otimizar o provimento desse serviço ambiental em função do tamanho e da localização da área de floresta. Quatorze diferentes cenários de uso e cobertura do solo foram analisados, utilizando-se um Sistema de Informações Geográficas e a Revised Universal Soil Loss Equation. A expectativa de perda de solo na sub-bacia das Posses antes e após a implementação do programa Conservador das Águas foi de 30,63 e 7,06 Mg ha-1 ano-1, respectivamente. A otimização da conservação do solo pode ser feita adotando-se práticas conservacionistas na pastagem e alocando-se a área de floresta de maneira mais otimizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A discussion about groundwater contamination is presented in this work. Contamination by agricultural activity, more specifically by pesticides is emphasized. Indirect and direct estimates could be used to predict pesticide behavior in soil, and consequently, to evaluate the potential of groundwater contamination. These results could be applied to advise about the possibility of groundwater contamination by pesticides, and to provide subsidies for making decisions more quickly and efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foi obtido o balanço de massa, a partir dos valores médios das determinações de demanda química de oxigênio (DQO) e produção de metano (CH4), em dois reatores UASB de bancada com volume de 10,5 L tratando águas residuárias de suinocultura, submetidos a condições operacionais distintas no que diz respeito às concentrações de sólidos suspensos totais do afluente (SST de 500; 1.000; 1.500 e 2.000 mg L-1), tempo de detenção hidráulica (TDH de 30; 20; 12 e 8 h), taxas de carregamento orgânico volumétrico (TCOV de 0,8 a 8,0 kg DQO total (m³ d)-1) e temperatura (ambiente e controlada a 25º e 30ºC). Verificou-se que a DQO total removida convertida em CH4 variou de 28 a 51% e a relação DQO-CH4 por DQO dissolvida removida de 0,94 a 2,07; indicando alta participação da remoção física dos sólidos do afluente, de 49 a 72%, na remoção de DQO total nos reatores, a qual variou de 75 a 92%. A concentração de SST do afluente, a temperatura, o TDH e a TCOV influenciaram nesse desempenho dos reatores UASB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se o efeito das águas residuárias de suinocultura com concentrações de sólidos suspensos totais em torno de 6.000 mg L-1 (DQOtotal variando de 7.557 a 11.640 mg L-1) no desempenho de processo anaeróbio em dois estágios compostos por reator compartimentado (ABR) e reator de fluxo ascendente com manta de lodo (UASB), instalados em série, em escala-piloto (volumes de 530 e 120 L, respectivamente), submetidos a tempos de detenção hidráulica (TDH) de 56 a 18 h no primeiro reator e de 13 a 4 h no segundo reator. As eficiências médias de remoção de DQOtotal variaram de 71,1 a 87,5% no reator ABR e de 41,5 a 50,1% no reator UASB, resultando em valores médios de 86,8 a 94,9% para o sistema de tratamento anaeróbio em dois estágios com carga orgânica volumétrica (COV), na faixa de 5,05 a 10,12 kg DQOtotal (m³ d)-1, no reator ABR, e de 2,83 a 9,63 kg DQOtotal (m³ d)-1, no reator UASB. As eficiências de remoção de SST e SSV foram da ordem de 95,6%. O teor de metano no biogás manteve-se acima de 70% para os dois reatores. A produção volumétrica de metano máxima de 0,755 m³ CH4 (m³ d)-1 ocorreu no reator 1, com COV de 10,12 kg DQOtotal (m³ d)-1 e TDH de 18 h. Os valores médios de pH variaram na faixa de 7,2 a 8,0 para os efluentes dos reatores 1 e 2. Os ácidos voláteis totais mantiveram-se estáveis com concentrações abaixo de 200 mg L-1. Com variações abruptas e acentuadas de concentrações de SST e DQOtotal do afluente, os reatores mantiveram as eficiências de remoção de DQO e sólidos suspensos, em torno de 70%, e a qualidade do biogás, com 80% de CH4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)