917 resultados para wastewater pumping station


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The need to contextualise wastewater-based figures about illicit drug consumption by comparing them with other indicators has been stressed by numerous studies. The objective of the present study was to further investigate the possibility of combining wastewater data to conventional statistics to assess the reliability of the former method and obtain a more balanced picture of illicit drug consumption in the investigated area. METHODS: Wastewater samples were collected between October 2013 and July 2014 in the metropolitan area of Lausanne (226,000 inhabitants), Switzerland. Methadone, its metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), the exclusive metabolite of heroin, 6-monoacetylmorphine (6-MAM), and morphine loads were used to estimate the amounts of methadone and heroin consumed. RESULTS: Methadone consumption estimated from EDDP was in agreement with the expectations. Heroin estimates based on 6-MAM loads were inconsistent. Estimates obtained from morphine loads, combined to prescription/sales data, were in agreement with figures derived from syringe distribution data and general population surveys. CONCLUSIONS: The results obtained for methadone allowed assessing the reliability of the selected sampling strategy, supporting its ability to capture the consumption of a small cohort (i.e., 743 patients). Using morphine as marker, in combination with prescription/sales data, estimates in accordance with other indicators about heroin use were obtained. Combining different sources of data allowed strengthening the results and suggested that the different indicators (i.e., administration route, average dosage and number of consumers) contribute to depict a realistic representation of the phenomenon in the investigated area. Heroin consumption was estimated to approximately 13gday(-1) (118gday(-1) at street level).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WCDMA tukiasema (Node B) on osa UMTS-järjestelmän radioverkkoa. Node B on tärkeä verkkoelementti, jonka tarkoituksena on yhdistää mobiilikäyttäjät verkkoon. Telecom –ohjelmisto (TCOM SW) on vastuussa suuresta osasta Node B:n toiminnallisuutta. TCOM SW:n testaukseen käytetään paljon resursseja, jotta ohjelmiston oikeasta toiminnasta ja laadusta voidaan varmistua. System component testing on testausvaihe, jossa järjestelmän (Node B) osa (system component, tässä diplomityössä TCOM SW) testataan ennen sen integroimista muuhun järjestelmään. Tähän tarvitaan testityökalu ja testitapausten toteutus. Node B TTCN Tester (testeri) on työkalu, jota käytetään Node B:n ohjelmiston testauksessa. Testitapaukset toteutetaan TTCN-testinotaatiota käyttäen ja testataan testerin avulla. TCOM SW:n system component –testausvaihetta varten testeriin lisättiin uudet rajapinnat, joiden avulla voidaan simuloita Node B:n ATM-ohjelmistoa sekä WPA- ja WTR-yksiköitä. Tässä diplomityössä toteuttiin TTCN testitapaukset uusille rajapinnoille. Testitapaukset tekivät TCOM SW system component –testausvaiheen riippumattomaksi Node B:n ATM-ohjelmistosta sekä WPA- ja WTR-yksiköistä. Lisäksi TCOM SW:n toiminnan testaus näissä rajapinnoissa voidaan tästä lähtien tehdä automaattisesti. Testitapauksien toiminta varmistettiin testeriä käyttäen. Tulokset olivat hyviä, uudet testitapaukset ja TTCN rajapinnat toimivat oikein lisäten testauksen tehokkuutta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TTCN-kieltä käytetään testitapausten määrittelemiseen tietoliikennejärjestelmissä. Nykyään TTCN:stä on tullut yhä suositumpi tapa toteuttaa testitapauksia. TTCN tarjoaa hyvän ja yksinkertaisen tavan muuntaa käsin testattavat testitapaukset automatisoiduiksi. Tämän diplomityön yhteydessä toteutettiin TTCN testitapaukset WCDMA -tukiaseman käyttö- ja kunnossapito- (O&M) ohjelmistolle. Ohjelmistoa on käytetty myös toisen sukupolven tukiasemissa, mutta kolmannen sukupolven tukiasemissa sillä on huomattavasti isompi rooli. WCDMA -tukiasemassa O&M käsittelee muun muassa tukiaseman käynnistyksen, virhetilanteet ja valvoo tukiaseman komponentteja. Ensimmäisiä tehtäviä diplomityötä tehdessä oli valita ne testitapaukset, jotka olisivat mahdollisia ja hyödyllisiä toteuttaa TTCN:n avulla. Testitapaukset valittiin valmiina olleista testitapausten kuvauksista. Valitut testitapaukset toteutettiin käyttäen rinnakkaista ja modulaarista TTCN-kieltä ja testattiin WCDMA -tukiasemaa vasten käyttäen TTCN Tester ohjelmistoa. Tämän diplomityön yhteydessä toteutettuja testitapauksia käytetään varmistamaan, että tukiasema voi toipua erilaisista virhetilanteista O&M ohjelmiston avulla. Testitapauksia WCDMA -tukiasemaa vasten ajettaessa varmistetaan myös, että O&M ohjelmisto toimii määrittelyn mukaisesti eri tilanteissa. Toteutetut testi tapaukset korvaavat nykyään käsin testatut O&M testi tapaukset tukiaseman O&M ohjelmistoa testatessa. Automatisoidut testi tapaukset tekevät O&M ohjelmiston testaamisen merkittävästi nopeammaksi ja helpommaksi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4x factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents briefly the basic operation and use of centrifugal pumps and parallel pumping applications. The characteristics of parallel pumping applications are compared to circuitry, in order to search analogy between these technical fields. The purpose of studying circuitry is to find out if common software tools for solving circuit performance could be used to observe parallel pumping applications. The empirical part of the thesis introduces a simulation environment for parallel pumping systems, which is based on circuit components of Matlab Simulink —software. The created simulation environment ensures the observation of variable speed controlled parallel pumping systems in case of different controlling methods. The introduced simulation environment was evaluated by building a simulation model for actual parallel pumping system at Lappeenranta University of Technology. The simulated performance of the parallel pumps was compared to measured values of the actual system. The gathered information shows, that if the initial data of the system and pump perfonnance is adequate, the circuitry based simulation environment can be exploited to observe parallel pumping systems. The introduced simulation environment can represent the actual operation of parallel pumps in reasonably accuracy. There by the circuitry based simulation can be used as a researching tool to develop new controlling ways for parallel pumps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All the experimental part of this final project was done at Laboratoire de Biotechnologie Environnementale (LBE) from the École Polytechnique Fédérale de Lausanne (EPFL), Switzerland, during 6 months (November 2013- May 2014). A fungal biofilter composed of woodchips was designed in order to remove micropollutants from the effluents of waste water treatment plants. Two fungi were tested: Pleurotus ostreatus and Trametes versicolor in order to evaluate their efficiency for the removal of two micropollutants: the anti-inflammatory drug naproxen and the antibiotic sulfamethoxazole,. Although Trametes versicolor was able to degrade quickly naproxen, this fungus was not any more active after one week of operation in the filter. Pleurotus ostreatus was, on contrary, able to survive more than 3 months in the filter, showing good removal efficiencies of naproxen and sulfamethoxazole during all this period, in tap water but also in real treated municipal wastewater. Several other experiments have provided insight on the removal mechanisms of these micropollutants in the fungal biofilter (degradation and adsorption) and also allowed to model the removal trend. Fungal treatment with Pleurotus ostreatus grown on wood substrates appeared to be a promising solution to improve micropollutants removal in wastewater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The activated sludge process - the main biological technology usually applied towastewater treatment plants (WWTP) - directly depends on live beings (microorganisms), and therefore on unforeseen changes produced by them. It could be possible to get a good plant operation if the supervisory control system is able to react to the changes and deviations in the system and can take thenecessary actions to restore the system’s performance. These decisions are oftenbased both on physical, chemical, microbiological principles (suitable to bemodelled by conventional control algorithms) and on some knowledge (suitable to be modelled by knowledge-based systems). But one of the key problems in knowledge-based control systems design is the development of an architecture able to manage efficiently the different elements of the process (integrated architecture), to learn from previous cases (spec@c experimental knowledge) and to acquire the domain knowledge (general expert knowledge). These problems increase when the process belongs to an ill-structured domain and is composed of several complex operational units. Therefore, an integrated and distributed AIarchitecture seems to be a good choice. This paper proposes an integrated and distributed supervisory multi-level architecture for the supervision of WWTP, that overcomes some of the main troubles of classical control techniques and those of knowledge-based systems applied to real world systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a study about the elimination of anticancer drugs, a group of pollutants considered recalcitrant during conventional activated sludge wastewater treatment, using a biological treatment based on the fungus Trametes versicolor. A 10-L fluidized bed bioreactor inoculated with this fungus was set up in order to evaluate the removal of 10 selected anticancer drugs in real hospital wastewater. Almost all the tested anticancer drugs were completely removed from the wastewater at the end of the batch experiment (8 d) with the exception of Ifosfamide and Tamoxifen. These two recalcitrant compounds, together with Cyclophosphamide, were selected for further studies to test their degradability by T. versicolor under optimal growth conditions. Cyclophosphamide and Ifosfamide were inalterable during batch experiments both at high and low concentration, whereas Tamoxifen exhibited a decrease in its concentration along the treatment. Two positional isomers of a hydroxylated form of Tamoxifen were identified during this experiment using a high resolution mass spectrometry based on ultra-high performance chromatography coupled to an Orbitrap detector (LTQ-Velos Orbitrap). Finally the identified transformation products of Tamoxifen were monitored in the bioreactor run with real hospital wastewater

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous work, a hybrid system consisting of an advanced oxidation process (AOP) named Photo-Fenton (Ph-F) and a fixed bed biological treatment operating as a sequencing batch biofilm reactor (SBBR) was started-up and optimized to treat 200 mg·L-1 of 4-chlorophenol (4-CP) as a model compound. In this work, studies of reactor stability and control as well as microbial population determination by molecular biology techniques were carried out to further characterize and control the biological reactor. Results revealed that the integrated system was flexible and even able to overcome toxic shock loads. Oxygen uptake rate (OUR) in situ was shown to be a valid tool to control the SBBR operation, to detect toxic conditions to the biomass, and to assess the recovery of performance. A microbial characterization by 16S rDNA sequence analysis reveals that the biological population was varied, although about 30% of the bacteria belonged to the Wautersia genus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over 50 years, several scientists and industries have developed new alternatives for wastewater treatment and remediation. Recently, electrochemical technology has been largely developed mainly because of its versatility and environmental compatibility. Scientific contributions about role of the electrode material have allowed determining that the influence of material in the selectivity is an important parameter. However, to interpret this behavior, comprehensive physical chemistry models for organics destruction, related to electrochemical phenomena and material surfaces, were proposed in the last decades. So, this paper presents a critical and comprehensive review about the principles and recent mechanism advances in electrocatalysis for wastewater treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the emission of N2O during the sequential aerated (60-min) and non-aerated (30-min) stages of an intermittent aeration cycle in an activated sludge wastewater treatment plant (WWTP). N2O emission occurred during both stages; however, emission was much higher during aeration. Air stripping is the major factor controlling transfer of N2O from the sewage to the atmosphere. The N2O emissions exclusively from the aeration tank represented 0.10% of the influent total nitrogen load and the per capita emission factor was almost 3 times higher than that suggested by the IPCC for inventories of N2O emission from WWTPs.