865 resultados para visual methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The routine methods for detecting Listeria sp. in foods are time consuming and involve using selective enrichments and plating on agars. In this study, the presence of Listeria sp. in 120 meat and meat product samples was investigated by two rapid immunoassays (TECRA Listeria Visual Immunoassay [VIA] and BioControl Visual Immunoprecipitate Assay [VIP] for Listeria) and a cultural procedure. The cultural method of detecting Listeria sp. followed Canada's Health Protection Branch Method, and the rapid tests followed the manufacturers' instructions. The agreement between the cultural and the rapid tests was established at a confidence limit of 95%. Seventy-nine samples (65.8%) were Listeria sp. positive in at least one of the three tests. There was no statistically significant difference between the cultural procedure and any of the rapid immunoassays. The agreement rates between the VIA and the cultural method and between the VIP and the cultural method were 87 and 84%, respectively. Both tests - the VIA and VIP - proved to be rapid, efficient and easy to perform.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The listing task, a method used in social and behavioral sciences, is frequently used in ethnobotanical research to constructfolk taxonomies and select relevant itemsfor subsequent research. The objective of the present study was to determine whether visual stimuli are associated with responses to the theme plants or if context influences the answers. Interviews were conducted with 400 women in Rio Claro, São Paulo, Brazil, in four different locations: three with a visible presence of plants (a plant store, a supermarket, and a public plaza) and one with no plants (a street corner in the center of the city). The women were asked to name plants. Analysis indicates that visual stimuli influenced responses and that this is more marked in the plant store than in the other locations. The plants cited most often-roses, orchids, ferns, violets, and daisies-were, with little variation, the same in all the locales studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Visual analysis is widely used to interpret regional cerebral blood flow (rCBF) SPECT images in clinical practice despite its limitations. Automated methods are employed to investigate between-group rCBF differences in research Studies but have rarely been explored in individual analyses.OBJECTIVES: To compare visual inspection by nuclear physicians with the automated statistical parametric mapping program using a SPECT dataset of patients with neurological disorders and normal control images.METHODS: Using statistical parametric mapping, 14 SPECT images from patients with various neurological disorders were compared individually with a databank of 32 normal images using a statistical threshold of p<0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). Statistical parametric mapping results were compared with Visual analyses by a nuclear physician highly experienced in neurology (A) as well as a nuclear physician with a general background of experience (B) who independently classified images as normal or altered, and determined the location of changes and the severity.RESULTS: of the 32 images of the normal databank, 4 generated maps showing rCBF abnormalities (p<0.05, corrected). Among the 14 images from patients with neurological disorders, 13 showed rCBF alterations. Statistical parametric mapping and physician A completely agreed on 84.37% and 64.28% of cases from the normal databank and neurological disorders, respectively. The agreement between statistical parametric mapping and ratings of physician B were lower (71.18% and 35.71%, respectively).CONCLUSION: Statistical parametric mapping replicated the findings described by the more experienced nuclear physician. This finding suggests that automated methods for individually analyzing rCBF SPECT images may be a valuable resource to complement visual inspection in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Species richness is central to ecological theory, with practical applications in conservation, environmental management and monitoring. Several techniques are available for measuring species richness and composition of amphibians in breeding pools, but the relative efficacy of these methods for sampling high-diversity Neotropical amphibian fauna is poorly understood. I evaluated seven studies from south and south-eastern Brazil to compare the relative and combined effectiveness of two methods for measuring species richness at anuran breeding pools: acoustic surveys with visual encounter of adults and dipnet surveys of larvae. I also compared the relative efficacy of each survey method in detecting species with different reproductive modes. Results showed that both survey methods underestimated the number of species when used separately; however, a close approximation of the actual number of species in each breeding pool was obtained when the methods were combined. There was no difference between survey methods in detecting species with different reproductive modes. These results indicate that researchers should employ multiple survey methods that target both adult and larval life history stages in order to accurately assess anuran species richness at breeding pools in the Neotropics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mining process promotes land modification and complete landscape alteration. Those alterations in the surface are shown more obviously in the aesthetical aspect as the visual elements of form, texture, climbs, complexity and color which composes the landscape. As a consequence, mining has impacts on the topography, in the soil, in the vegetation and in the area's drainage, with a direct influence on the enterprise. A quite common problem in the recovery of degraded areas in mineral exploration is the compaction of the soil due to the intense traffic of machines and earth movement. The most common problem of the compaction of a degraded surface is an increase of the mechanical resistance to the penetration of plant roots, a reduction of the aeration, an alteration of the flow of water and heat, also in the availability of water and nutrients. Thus, the present work had the basic objective of diagnosing the compaction of an area degraded by mining in a spacial way, through the mechanical resistance and the penetration, to guide the future subsoiling in the area requiring recovery. Through the studies, it was concluded that the krigagem method in agreement with the space variation allows the division of the area under study into sub areas facilitating a future work to reduce costs and unnecessary interference to the atmosphere. The method was shown to be quite appropriate and it can be used in the diagnosis of compaction in a degraded area by mining, foreseeing the subsoiling requirement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Materials and Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. Results: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D 1 threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D 2 threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D 3 threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility. © 2012 Springer-Verlag London Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A seletividade espacial para cor tem sido investigada usando métodos eletrofisiológicos invasivos e não invasivos, e métodos psicofísicos. Em eletrofisiologia cortical visual não invasiva este tópico foi investigado usando métodos convencionais de estimulação periódica e extração de respostas por promediação simples. Novos métodos de estimulação (apresentação pseudo-aleatória) e extração de respostas corticais não invasivas (correlação cruzada) foram desenvolvidos e ainda não foram usados para investigar a seletividade espacial de cor de respostas corticais. Este trabalho objetivou introduzir esse novo método de eletrofisiologia pseudoaleatória para estudar a seletividade espacial de cor. Foram avaliados 14 tricromatas e 16 discromatópsicos com acuidade visual normal ou corrigida. Os voluntários foram avaliados pelo anomaloscópio HMC e teste de figuras de Ishihara para caracterizar a visão de cores quanto à presença de tricromacia. Foram usadas redes senoidais, 8º de ângulo visual, vermelho-verde para 8 frequências espaciais entre 0,2 a 10 cpg. O estímulo foi temporalmente modulado por uma sequência-m binária em um modo de apresentação de padrão reverso. O sistema VERIS foi usado para extrair o primeiro e o segundo slice do kernel de segunda ordem (K2.1 e K2.2, respectivamente). Após a modelagem da resposta às frequências espaciais com função de diferença de gaussianas, extraiu-se a frequência espacial ótima e banda de frequências com amplitudes acima de ¾ da amplitude máxima da função para servirem como indicadores da seletividade espacial da função. Também foi estimada a acuidade visual cromática pelo ajuste de uma função linear aos dados de amplitude a partir da frequência espacial do pico de amplitude até a mais alta frequência espacial testada. Em tricromatas, foi encontrada respostas cromáticas no K2.1 e no K2.2 que apresentaram seletividade espacial diferentes. Os componentes negativos do K2.1 e do K2.2 apresentaram sintonia passa-banda e o componente positivo do K2.1 apresentou sintonia passa-baixa. A acuidade visual estimada de todos os componentes estudados foi próxima àquelas encontradas por Mullen (1985) e Kelly (1983). Diferentes componentes celulares podem estar contribuindo para a geração do VECP pseudoaleatório. Este novo método se candidata a ser uma importante ferramenta para a avaliação não invasiva da visão de cores em humanos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os solventes orgânicos são substâncias neurotóxicas que podem causar efeitos danosos sobre as funções visuais. É comum a exposição ocupacional a esses tipos de substâncias, pois elas apresentam grande aplicabilidade em inúmeras atividades. Os efeitos podem ser quantificados por testes psicofísicos. Os testes mais usados nesse tipo de avaliação são de ordenamento de matizes, como o Teste D15 Dessaturado de Lanthony e o Teste dos 100 Matizes de Farnsworth-Munsell, e avaliação de sensibilidade ao contraste espacial de luminância, como MCT 8000 Vistech, VCTS 6500 Vistech e FACT 101. Em geral esses testes descrevem perda de discriminação de cores, afetando tanto o eixo azul-amarelo quanto o eixo verde-vermelho, e diminuição da sensibilidade ao contraste de luminância principalmente para as frequências espaciais mais baixas. Existe correlação positiva entre os resultados da avaliação psicofísica e vários marcadores biológicos e ambientais, mas essa correlação depende do marcador e do tipo de solvente ao qual os indivíduos são expostos. Fatores como alcoolismo crônico e tabagismo inveterado podem interferir no processo de correlacionar esses resultados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.