941 resultados para trans-rectal ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Perineal stapled prolapse (PSP) resection is a novel operation for treating external rectal prolapse. However, no long-term results have been reported in the literature. This study analyses the long-term recurrence rate, functional outcome, and morbidity associated with PSP resection. METHODS: Nine consecutive patients undergoing PSP resection between 2007 and 2011 were prospectively followed. Surgery was performed by the same surgeons in a standardised technique. Recurrence rate, functional outcome, and complication grade were prospectively assessed. RESULTS: All 9 patients undergoing PSP resection were investigated. The median age was 72 years (range 25-88 years). No intraoperative complications occurred. Faecal incontinence, preoperatively present in 2 patients, worsened postoperatively in one patient (Vaizey 18-22). One patient developed new-onset faecal incontinence (Vaizey 18). The median obstructive defecation syndrome score decreased postoperatively significantly from 11 (median; range 8-13) to 5 (median; range 4-8) (p < 0.005). At a median follow-up of 40 months (range 14-58 months), the prolapse recurrence rate was 44 % (4/9 patients). CONCLUSIONS: The PSP resection is a fast and safe procedure associated with low morbidity. However, the poor long-term functional outcome and the recurrence rate of 44 % warrant a cautious patient selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess reproducibility and feasibility of amusculoskeletal ultrasound (US) score for rheumatoid arthritis amongrheumatologist with diverse expertise in US, working in private orhospital practice.Methods: The Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a semi-quantitative score for RA usingOMERACT criteria for synovitis and erosion. The score was taught torheumatologists trained in US through two workshops. Subsequently,they were encouraged to practice in their office. For the study, we used6 US machines of different quality, each with a different patient.19 readers randomly selected among rheumatologists who haveattended both workshops, were asked to score anonymously at leastone patient. To assess whether some factors influence the score, weasked each reader to answer questionnaire describing his experiencewith US.Results: 19 rheumatologists have performed 29 scans, each patienthaving been evaluated by 4 to 6 readers. Median time for examcompletion was 20 minutes (range 15 to 60 mn). 53% ofrheumatologists work in private practice. Graph 1 show the global greyscale score for each patient. Weighted kappa was calculated for eachpair of reader using stata11. Almost all kappa of poor agreement wereobtained with a low quality device or by an assessor who havepreviously performed less than 5 scores himself.Conclusions: This is the first study to show an US score for RAfeasible by rheumatologists with diverse expertise in US both in privateand hospital practice. Reproducibility seemed to be influenced by thequality of device and previous experience with the score.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi prospectiu de 208 pacients intervinguts de Cirurgia Colo-Rectal electiva amb anastomosi. L’objectiu és avaluar el valor de la monitorització de la Proteïna C-Reactiva (PCR) com a marcador biològic precoç de Dehiscència d’Anastomosi. La disminució de la PCR entre el segon i el cinquè dia del postoperatori de més del 39% té un valor predictiu negatiu del 97%, pel què pensem que hauria de ser una eina a tenir en compte en un protocol de fast-track. La PCR ha demostrat ser un paràmetre més fiable que els paràmetres de resposta inflamatòria sistèmica (recompte leucocitari, freqüència cardíaca, freqüència respiratòria i temperatura).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, management of abdominal pain in emergency care units (ECU) has undergone a radical change. Chronic work overload of ECU and increase in severity and complexity of cases required an optimal medical imaging method, such as ultrasound, to establish an accurate diagnosis as quickly as possible. A great variety of causes may cause acute abdominal pain and the role of sonography is to accurately distinguish between these aetiologies. For the application of sonography, perhaps more so than with other imaging methods, a perfect knowledge of sonographical characteristics and technical possibilities is essential to achieve an optimal answer. The purpose of this review is to present and discuss the sonographic characteristics of extra-digestive causes of acute abdominal pain such as splenic infarction, thoracic pathologies, urinary and gynaecologic diseases or retroperitoneal pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Directory of Colon and Rectal Cancer Specialist Teams has been produced under the auspices of the Northern Ireland Regional Advisory Committee on Cancer. It contains details of the full membership of the clinical teams providing care for colon and rectal cancer in each of Health and Social Services Board Area. Lead Clinicians For Colon and Rectal Cancer Services (PDF 74 KB) EHSSB (PDF 198 KB) NHSSB (PDF 107 KB) SHSSB (PDF 130 KB) WHSSB (PDF 131 KB)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio de los polimorfismos del gen de la timidilato sintasa y los genes reparadores del ADN ERCC1 y XRCC1 y su relación con la rdespuesta al tratamiento neoadyvante con qumiorradioterapia basada en capecitabin, en pacientes afecto de carcinoma colorrectal de localmente avanzado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. METHODS: 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. RESULTS: QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. CONCLUSIONS: QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A group of experts on schistosomiasis and ultrasonography discussed the experiences and results obtained with the Niamey-Belo Horizonte Protocol on Ultrasonography in Schistosomiasis. A series of recomendations about qualitative and quantitative data obtained by ultrasound in studies performed in Africa and Brazil are presented. Imunological, genetic and epidemiological studies must rely on ultrasound for the identification of patients with periportal thickening/fibrosis.