959 resultados para three-level converter
Resumo:
Coastal low-level jets (CLLJ) are a low-tropospheric wind feature driven by the pressure gradient produced by a sharp contrast between high temperatures over land and lower temperatures over the sea. This contrast between the cold ocean and the warm land in the summer is intensified by the impact of the coastal parallel winds on the ocean generating upwelling currents, sharpening the temperature gradient close to the coast and giving rise to strong baroclinic structures at the coast. During summertime, the Iberian Peninsula is often under the effect of the Azores High and of a thermal low pressure system inland, leading to a seasonal wind, in the west coast, called the Nortada (northerly wind). This study presents a regional climatology of the CLLJ off the west coast of the Iberian Peninsula, based on a 9km resolution downscaling dataset, produced using the Weather Research and Forecasting (WRF) mesoscale model, forced by 19 years of ERA-Interim reanalysis (1989-2007). The simulation results show that the jet hourly frequency of occurrence in the summer is above 30% and decreases to about 10% during spring and autumn. The monthly frequencies of occurrence can reach higher values, around 40% in summer months, and reveal large inter-annual variability in all three seasons. In the summer, at a daily base, the CLLJ is present in almost 70% of the days. The CLLJ wind direction is mostly from north-northeasterly and occurs more persistently in three areas where the interaction of the jet flow with local capes and headlands is more pronounced. The coastal jets in this area occur at heights between 300 and 400 m, and its speed has a mean around 15 m/s, reaching maximum speeds of 25 m/s.
Resumo:
Locomotor tasks characterization plays an important role in trying to improve the quality of life of a growing elderly population. This paper focuses on this matter by trying to characterize the locomotion of two population groups with different functional fitness levels (high or low) while executing three different tasks-gait, stair ascent and stair descent. Features were extracted from gait data, and feature selection methods were used in order to get the set of features that allow differentiation between functional fitness level. Unsupervised learning was used to validate the sets obtained and, ultimately, indicated that it is possible to distinguish the two population groups. The sets of best discriminate features for each task are identified and thoroughly analysed. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
Resumo:
This paper presents a systemic modeling for a PV system integrated into an electric grid. The modeling includes models for a DC-DC boost converter and a DC-AC two-level inverter. Classical or fuzzy PI controllers with pulse width modulation by space vector modulation associated with sliding mode control is used for controlling the PV system and power factor control is introduced at the output of the system. Comprehensive performance simulation studies are carried out with the modeling of the DC-DC boost converter followed by a two-level power inverter in order to compare the performance with the experimental results obtained during in situ operation with three commercial inverters. Also, studies are carried out to assess the quality of the energy injected into the electric grid in terms of harmonic distortion. Finally, conclusions regarding the integration of the PV system into the electric grid are presented. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.
Resumo:
This paper presents the design and compares the performance of linear, decoupled and direct power controllers (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFC). A simplified steady-state model of the matrix converter-based UPFC fitted with a modified Venturini high-frequency pulse width modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) powers. In order to minimize the resulting cross coupling between P and Q power controllers, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. DPC are then developed using sliding-mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behaviour but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and faster responses with no overshoot and no steady-state error. All the designed controllers were implemented using the same digital signal processing hardware.
Resumo:
Objectives - To identify occupational stressors and coping resources in a group of physiotherapists, and to analyse interactions between subjective levels of stress, efficacy in stress resolution and coping resources used by these professionals. Design - A sample of 55 physiotherapists working in three general hospitals in Portugal completed the Coping Resources Inventory for Stress, the Occupational Stressors Inventory and two subjective scales for stress and stress resolution. Main results - Most physiotherapists perceived that they were moderately stressed (19/55, 35%) or stressed (20/55, 36%) due to work, and reported that their efficacy in stress resolution was moderate (25/54, 46%) or efficient (23/54, 42%). Issues related to lack of professional autonomy, lack of organisation in the hierarchical command chain, lack of professional and social recognition, disorganisation in task distribution and interpersonal conflicts with superiors were identified as the main sources of stress. The most frequently used coping resources were social support, stress monitoring, physical health and structuring. Perceived efficacy in stress resolution was inversely related to perceived level of occupational stress (r = −0.61, P < 0.01). Significant correlations were found between several coping resources and the perceived level of stress and efficacy in stress resolution. Associations between problem solving, cognitive restructuring and stress monitoring and both low levels of perceived stress and high levels of perceived efficacy were particularly strong. Implications for practice - The importance of identifying stressors and coping resources related to physiotherapists’ occupational stress, and the need for the development of specific training programmes to cope with stress are supported.
Resumo:
The present investigation was carried out on a sample of 840 children (5 to 16 years old) from ten small towns of the State of Bahia in northeastern Brazil. The objetive was to study, by using a cross sectional methodology, the evolution of schistosomiasis morbidity (hepatic and splenic enlargement) in children, and the role of the intensity of S. mansoni infection in this process. The children were analised in three age groups (5 to 8, to 12 and 13 to 16 years old) and classified as uninfected, mildly infected, moderately infected and heavily infected according to the number of eggs in the stool. In children aged 5 to 8 years, increasing egg counts were not associated with increasing frequencies of hepatic or splenic enlargement. In the 9 to 12 years old group and association was observed with the prevalence of hepatic enlargement, but not with the prevalence of spleen enlargement. In the oldest group, 13 to 16 years old, an association was observed with the prevalence of enlargement of both organs. It was evident that in this population schistosomiasis morbidity develops in the early period of life as a gradual process starting with liver enlargement and followed by spleen enlargement some years later. It was found that the intensity of infection has a fundamental role in this process, although there is a latent period of some years before clinical splenomegaly appears in moderate-heavily infected children. The Authors suggest that the prevalence of splenomegaly in the 13 to 16 years old group is a good measure of the community level of schistosomiasis morbidity and could be used to measure the impact of control programs.
Resumo:
Mycologia, Vol. 98, nº6
Resumo:
A schistosomiasis control program was implemented between 1974/87 in Peri-Peri,. MG (622 inhabitants). Molluscicide (niclosamide) was applied at three monthly intervals in water sources with Biomphalaria glabrata, and individuals eliminating Schistosoma mansoni eggs in the feces were treated annually with oxamniquine. From 1974 to 1983 the control measures were undertaken by staff of the "René Rachou" Research Center FIOCRUZ (CPqRR), and from 1984 to 1987 these measures were included in the Capim Branco basic health network activities. During both periods, the prevalence, incidence, intensity of infection and hepatosplenic form as well as the number of infected snails decreased significantly. The prevalence decreased from 43.5 to 4.4%, the incidence from 19.0 to 2.9%, the overall intensity of S. mansoni from 281 to 87 and of the hepatosplenic form from 5.9 to 0.0%. The results obtained suggest that the municipal management of control measures was as effective as the vertical program conducted by CPqRR staff.
Resumo:
This paper presents the design and implementation of direct power controllers for three-phase matrix converters (MC) operating as Unified Power Flow Controllers (UPFC). Theoretical principles of the decoupled linear power controllers of the MC-UPFC to minimize the cross-coupling between active and reactive power control are established. From the matrix converter based UPFC model with a modified Venturini high frequency PWM modulator, decoupled controllers for the transmission line active (P) and reactive (Q) power direct control are synthesized. Simulation results, obtained from Matlab/Simulink, are presented in order to confirm the proposed approach. Results obtained show decoupled power control, zero error tracking, and fast responses with no overshoot and no steady-state error.
Resumo:
Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Sciences
Resumo:
Enterprise and Work Innovation Studies,6,IET, pp.9-51
Resumo:
The congenital transmission of Chagas disease was evaluated in 57 pregnant women with Chagas disease and their 58 offspring. The patients were selected from three Health Institutions in São Paulo City. The maternal clinical forms of Chagas disease were: indeterminate (47.4%), cardiac (43.8%) and digestive (8.8%); 55 were born in endemic areas and two in São Paulo City. The transmission of Chagas disease at fetal level was confirmed in three (5.17%) of the 58 cases studied and one probably case of congenital Chagas disease. Two infected infants were born to chagasic women with HIV infection and were diagnosed by parasitolological assays (microhematocrit, quantitative buffy coat-QBC or artificial xenodiagnosis). In both cases the placenta revealed T. cruzi and HIV p24 antigens detected by immunohistochemistry. In one case, a 14-week old abortus, the diagnosis of congenital T. cruzi infection was confirmed by immunohistochemistry. The other probable infection, a 30-week old stillborn, the parasites were found in the placenta and umbilical cord. The Western blot method using trypomastigote excreted/secreted antigens of T. cruzi (TESA) was positive for IgG antibodies in 54/55 newborns and for IgM in 1/55 newborns. One of the two newborns with circulating parasites had no detectable IgG or IgM antibodies. The assessment of IgG antibodies in the sera of pregnant women and their newborns was performed by ELISA using two different T. cruzi antigens: an alkaline extract of epimastigotes (EAE) and trypomastigote excreted/secreted antigens (TESA). The analysis showed a linear correlation between maternal and newborn IgG antibody titers at birth.
Resumo:
Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentáveis