998 resultados para tecido ósseo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Due to complications caused by metallic implants in the replacement of bone tissue, the biological application of ceramics raised and became a viable alternative. The titania has the ability to promote bone tissue regeneration based on its structure, mechanical and biologically properties compatibility. The present work aims at obtaining and characterization of Titania (TiO2) porous ceramics produced by the polymeric sponge method (replica method). Polyurethane sponge with 10 ppi and 15 ppi (pores per linear inch) were used. The process differentiation is the air blower used to remove excess slurry. The ceramics sponges were dried in an oven, then pre-sintered at 1000 o C and sintered at 1450 o C. The effect of direct sintering at 1450 o C was also assessed. The percentage of solids used to prepare the slurry was 40 to 45% by weight. To increase the surface porosity of the sponge, 20% of starch was added. There was difficulty on controlling the thickness of the slurry layers on the sponge which resulted in the variation of samples mechanical resistance. Despite this, the results obtained are quite promising for the proposed use, indicating that it is possible to obtain titania sponges with an apparent porosity of around 60%, a bulk density ranging from 40 to 47% and a compressive strength resistance – that with better control of layers depositions – can vary from 1 to 4 MPa

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A presença de falhas, trincas, furos e fadigas causam perturbações nos modos vibracionais (normais) de uma estrutura, por exemplo, tubos, gasodutos e peças metálicas. Uma vez conhecido o espectro de freqüência de uma estrutura instalada em condições normais (sem falhas), é possível acompanhar através, de ensaios não destrutivos uma alteração no espectro de freqüência que pode estar associado a alguma falha mecânica na estrutura.O presente trabalho busca encontrar um padrão nos sinais de resposta dos materiais analisados pela técnica de Vibroacustografia, antes e depois das deformidades causadas. Tentando viabilizar a técnica para a utilização em Ensaios Não Destrutivos (END). E futuramente, para as amostras biológicas, espera-se estender os conhecimentos obtidos dos ensaios anteriores para detecção e prevenção de possíveis fraturas do tecido ósseo

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As mudanças demográficas decorrentes do envelhecimento populacional têm contribuído substancialmente para o aumento de doenças crônicas não transmissíveis relacionadas à idade, dentre elas está a osteoporose, considerada um dos principais problemas de saúde pública, por sua prevalência crescente e pela associação a fraturas em diversas áreas do corpo, com graves repercussões clínicas e sociais. Com isso vem se buscando cada vez mais alternativas de exercício físico válidas para o combate e prevenção a estas doenças ósseas. Como possível alternativa têm se estudado os efeitos e benefícios dos treinamentos realizados em Plataformas Vibratórias, equipamento que através de baixa amplitude e alta freqüência pode vir a influenciar positivamente nas capacidades físicas. Portanto, devido à escassez de informações acerca dos efeitos do exercício na plataforma vibratória sobre a microarquitetura dos ossos em indivíduos idosos e já acometidos pela osteoporose, o objetivo deste estudo foi, com um modelo animal, descrever através de imagens de Microscopia Eletrônica de Varredura (MEV), a reação do tecido ósseo de ratas idosas ovariectomizadas ao exercício em Plataforma Vibratória. Para execução deste estudo foram utilizadas 20 ratas Wistar (Rattus Norvegicus Albinus Wistar), separadas em 4 grupos: Sedentário Controle (S), Sedentário Ovariectomizado (SO), Treinado Controle (T) e Treinado Ovariectomizado (TO). Como protocolo de treinamento a plataforma vibratória foi regulada com freqüência de 35 Hz e amplitude baixa (1 a 2 mm) e consistiu de uma fase de adaptação ao exercício e à vibração e após este período uma fase de treinamento. Para análise a região do osso selecionada foi o terço proximal da diáfise do fêmur. Como resultado, obtivemos que para o grupo SO a indução à osteoporose foi positiva quando comparada ao grupo S, que ...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paediatric diagnostic radiology can be considered as a separate specialty and with distinct characteristics of the radiology applied in adult patients. This in reason of the variability in the anatomical structures size and bigger sensitivity of tissues. The literature present in its majority methodologies for segmentation and tissue classification in adult patients, and works on tissue quantification are rare. This work had for objective the development of a biological tissue classifier and quantifier algorithm, from histograms, and that converts the quantified average thickness of these tissues for its respective simulator materials. The results will be used in the optimization process of paediatrics images, in future works, since these patients are frequently over exposed to the radiation in the repeated attempts of if getting considered good quality radiographic images. The developed algorithm was capable to read and store the name of all the archives, in the operational system, to filter artifacs, to count and quantify each biological tissues from the histogram of the examination, to obtain the biological tissues average thicknesses and to convert this value into its respective simulator material. The results show that it is possible to distinguish bone, soft, fat and pulmonary tissues from histograms of tomographic examinations of thorax. The quantification of the constituent materials of anthropomorphic phantom made by the algorithm, compared with the data of literature shows that the biggest difference was of 21,6% for bone. However, the literature shows that variations of up to 30% in bone thickness do not influence of significant form in the radiographic image quality. The average thicknesses of biological tissues, quantified for paediatrics patients, show that one phantom can simulate patients with distinct DAP ranges, since variations... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium has proven its suitability as an implant material in surgery over many years. Excellent biocompatibility and corrosion resistance are outstanding features. Implant surfaces always causes concern and interest in scientific communities, due to its close relationship with the time required for osseointegration. Surface modification can be performed by several methods, being laser irradiation one of them. Titanium implants with two different surfaces were inserted in rabbits: Group I (G-I: machined surface, control group), and group II (G-II: laser irradiated, test group) being processed 30 and 60 days after surgery for histological analysis. Surface characterization was performed with SEM-EDS, contact angle measurement, and mean roughness (Ra) parameters. Surface analysis in the GII group showed a nanomorphology affected by melt and quick solidification zones following laser irradiation (SEM), as well as total wettability and Ra mean values significantly higher than in the G-I group. The laser treatment resulted in a homogenized, porous surface, with increased surface area and volume. Histological analysis of bone-implant contact linear extension (BIC) showed better results in G-II at 30 days (39.26 ± 18.23 and 68.41 ± 13.68 for G-I and G-II groups, respectively). Titanium implants modified by laser irradiation showed important features that may accelerate early osseointegration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of this study is to evaluate by histometric and immunohistochemistry analysis the effects of antimicrobial photodynamic therapy (aPDT) in alveolar prior to placement of mini-implants in animals with or without induced periodontal disease. Material and method: Thirty-two rats were used. Periodontal disease (PD) was induced by ligature in the lower left first molar. After 7 days of PD evolution, it was performed removal of the ligature and extraction of the left lower first molars in all animals. Thus, animals were divided into 2 groups (n=16) according to the treatments in the dental alveolus before immediate implant installation: MD (control) : mechanical debridement (MD), irrigation with 1 ml of saline solution followed by implant installation; aPDT- MD, irrigation with 1 ml of Toluidine Blue-O and low intensity laser (LLLT) and implant installation. Eight animals from each group were euthanized at 15 and 30 days after the installation of mini-implants. Specimens were processed for histologic, immunohistochemical and histometric analysis. The histometric data were processed for statistical analysis (Kruskall-Wallis and Dunn test; p <0.05). Result: In treatment analysis, results indicated that there was a greater BIC in implants installed in uncontaminated alveolus treated with a PDT ( p<0,05) and greater imuno-reactivity to OPG in bone issue treated with aPDT. Conclusion: The aPDT proved to be effective in bone loss control in no contaminated area and it has increased the bone loss and metabolic activity in alveolus irradiated prior to implant installation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)